Background CEPC is a 100-kilometer-long electron-position collider,aiming to produce Higgs,W and Z-pole.Double ring(DR)is the baseline design of its main ring,and advanced partial double ring(APDR)is the alternative o...Background CEPC is a 100-kilometer-long electron-position collider,aiming to produce Higgs,W and Z-pole.Double ring(DR)is the baseline design of its main ring,and advanced partial double ring(APDR)is the alternative one.Purpose The purpose of this paper is to study the beam loading effects and the corresponding longitudinal beam dynamics of CEPC DR and APDR.Methods The phase shift of the bunches modulated by the bunch gap is calculated with the approximation formulas and simulated with the program.All these methods are compared,and the application conditions of them are also elaborated.In addition,the longitudinal coupled-bunch instability in CEPC main ring is calculated by analytical formulas.Results In CEPC DR high-lumi Z,the phase shift can be reduced to 0.51 deg(°).Besides,the total number of unstable longitudinal modes is 15 in CEPC DR high-lumi Z when no feedback system is added.Conclusion The phase shift of the bunches in CEPC can be reduced to an acceptable value if the optimal filling pattern is chosen.For CEPC APDR,the RF parameters are calculated and the beam loading effects are tolerable.展开更多
基金This study was supported by National Key Programme for S&T Research and Development(Grant No.:2016YFA0400400)National Natural Science Foundation of China(No.11575218)Key research Program of Frontier Science,CAS(Grant No.:QYZDJ-SSW-SLH004).
文摘Background CEPC is a 100-kilometer-long electron-position collider,aiming to produce Higgs,W and Z-pole.Double ring(DR)is the baseline design of its main ring,and advanced partial double ring(APDR)is the alternative one.Purpose The purpose of this paper is to study the beam loading effects and the corresponding longitudinal beam dynamics of CEPC DR and APDR.Methods The phase shift of the bunches modulated by the bunch gap is calculated with the approximation formulas and simulated with the program.All these methods are compared,and the application conditions of them are also elaborated.In addition,the longitudinal coupled-bunch instability in CEPC main ring is calculated by analytical formulas.Results In CEPC DR high-lumi Z,the phase shift can be reduced to 0.51 deg(°).Besides,the total number of unstable longitudinal modes is 15 in CEPC DR high-lumi Z when no feedback system is added.Conclusion The phase shift of the bunches in CEPC can be reduced to an acceptable value if the optimal filling pattern is chosen.For CEPC APDR,the RF parameters are calculated and the beam loading effects are tolerable.