The lower bounds for the blow-up time of blow-up solutions to the nonlinear nolocal porous equation ut=△u^m+u^p∫Ωu^qdxwith either null Dirichlet boundary condition or homogeneous Neumann boundary condi- tion is g...The lower bounds for the blow-up time of blow-up solutions to the nonlinear nolocal porous equation ut=△u^m+u^p∫Ωu^qdxwith either null Dirichlet boundary condition or homogeneous Neumann boundary condi- tion is given in this article by using a differential inequality technique.展开更多
In this paper,a class of slow reaction-diffusion equations with nonlocal source and inner absorption terms are studied.By using the technique of improved differential inequality,the lower bounds of blow up time for th...In this paper,a class of slow reaction-diffusion equations with nonlocal source and inner absorption terms are studied.By using the technique of improved differential inequality,the lower bounds of blow up time for the system under either homogeneous Dirichlet or nonhomogeneous Neumann boundary conditions are obtained.展开更多
A novel test access mechanism (TAM) architecture with multi test-channel (TC) based on IEEE Standard 1500 is proposed instead of the traditional sub-TAM structure. The cost model of an area-time associated test an...A novel test access mechanism (TAM) architecture with multi test-channel (TC) based on IEEE Standard 1500 is proposed instead of the traditional sub-TAM structure. The cost model of an area-time associated test and the corresponding lower bound of system-on-chip (SoC) test time are established based on this TAM architecture. The model provides a more reliable method to control the SoC scheduling and reduces the complexity in related algorithm research. The result based on the area time associated test cost model has been validated using the ITC02 test benchmark.展开更多
Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechani...Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechanisms on the lower molding temperature limit and molding time in dental thermoforming. Ethylene vinyl acetate resin mouthguard sheet and two thermoforming machines;vacuum blower molding machine and vacuum ejector/pressure molding machine were used. The molding pressures for suction molding were −0.018 MPa for vacuum blower molding and −0.090 MPa for vacuum ejector molding, and for pressure molding was set to 0.090 MPa or 0.450 MPa. Based on the manufacturer’s standard molding temperature of 95˚C, the molding temperature was lowered in 2.5˚C increments to determine the lower molding temperature limit at which no molding defects occurred. In order to investigate the difference in molding time depending on the molding mechanism, the duration of molding pressure was adjusted in each molding machine, and the molding time required to obtain a sample without molding defects was measured. The molding time of each molding machine were compared using one-way analysis of variance. The lower molding temperature limit was 90.0˚C for the vacuum blower machine, 77.5˚C for the vacuum ejector machine, 77.5˚C for the pressure molding machine at 0.090 MPa, and 67.5˚C for the pressure molding machine at 0.45 MPa. The lower molding temperature limit was higher for lower absolute values of molding pressure. The molding time was shorter for pressure molding than for suction molding. Significant differences were observed between all conditions except between the pressure molding machine at 0.090 MPa and 0.45 MPa (P < 0.01). A comparison of the differences in lower molding temperature limit and molding time due to molding mechanisms in dental thermoforming revealed that the lower molding temperature limit depends on the molding pressure and that the molding time is longer for suction molding than for pressure molding.展开更多
The traditional HB-weighted time-delay estimation (TDE) method degenerates under the impulsive noise environment. Two new time-delay estimation methods are proposed based on fractional lower order statistics (FLOS...The traditional HB-weighted time-delay estimation (TDE) method degenerates under the impulsive noise environment. Two new time-delay estimation methods are proposed based on fractional lower order statistics (FLOS) according to the impulsive characteristics of fractional lower order α-stable noises. Theoretic analysis and computer simulations indicate that the proposed covariation based HB weighted (COV-HB) algorithm can suppress impulsive noises in one received signal for 1 ≤α≤ 2, whereas the other proposed fractional lower order eovariancebased HB weighted (FLOC-HB) algorithm has robust performance under arbitrary impulsive noise conditions for the whole range of 0 〈α≤ 2.展开更多
The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the...The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the TOI of multiple scan cycles into the direction difference of arrival(DDOA) model,the observability analysis for the TMA problem is performed.Some necessary conditions for uniquely identifying the scanning emitter trajectory are obtained.This paper also proposes a weighted instrumental variable(WIV) estimator for the scanning emitter TMA,which does not require any initial solution guess and is closed-form and computationally attractive.More importantly,simulations show that the proposed algorithm can provide estimation mean square error close to the Cramer-Rao lower bound(CRLB) at moderate noise levels with significantly lower estimation bias than the conventional pseudo-linear least square(PLS) estimator.展开更多
Synchronization with lower SNR hadn't been considered by the conventional publications. Based on the Synchronized multi-carrier CDMA plus (SMCC+) system, which is one of the candidate schemes of digital terrestria...Synchronization with lower SNR hadn't been considered by the conventional publications. Based on the Synchronized multi-carrier CDMA plus (SMCC+) system, which is one of the candidate schemes of digital terrestrial TV broadcasting (DTTB) standard in China, a scheme under lower SNR with one short training sequence and one Barker code group, which were constructed in time domain. Computer simulation results show that the timing estimator here is designed to avoid the ambiguity which occured in Tufvesson's timing synchronization method. The 99.9% correct timing synchronization probability and lower false probability are got in AWGN and Rayleigh fading channels with SNR under -20 dB, and the optimum properties of frequency synchronization are obtained at the same time. It is shown that the proposed scheme is much better than the conventional synchronization methods.展开更多
基金supported by the Fundamental Research Funds for the Central Universities (CDJXS 11 10 00 19)Mu Chunlai is supported by NSF of China(11071266)
文摘The lower bounds for the blow-up time of blow-up solutions to the nonlinear nolocal porous equation ut=△u^m+u^p∫Ωu^qdxwith either null Dirichlet boundary condition or homogeneous Neumann boundary condi- tion is given in this article by using a differential inequality technique.
基金Supported by the Natural Science Foundation of Shaanxi Province(2019JM-534)the Youth Innovation Team of Shaanxi Universities+7 种基金the 14th Five Year Plan for Educational Science in Shaanxi Province(SGH21Y0308)Key Topic of China Higher Education Association(21DFD04)Higher Education Teaching Reform Project of Xi’an International University(2023B03)2022 Annual Planning Project of China Association of Private Education(School Development)(CANFZG22222)Project of Department of Education of Shaanxi Provincethe 2022 Annual Topic of the"14th Five-Year Plan"of Shaanxi Provincial Educational Science(SGH22Y1885)Project of Qi Fang Education Research Institute of Xi’an International University(23mjy10)Special Project of the Shaanxi Provincial Social Science Found in 2023(2023SJ12,2023LS04)。
文摘In this paper,a class of slow reaction-diffusion equations with nonlocal source and inner absorption terms are studied.By using the technique of improved differential inequality,the lower bounds of blow up time for the system under either homogeneous Dirichlet or nonhomogeneous Neumann boundary conditions are obtained.
基金Project supported by the SDC Project of Science and Technology Commission of Shanghai Municipality (Grant No.08706201000)the AM Foundation Project of Science and Technology Commission of Shanghai Municipality (Grant No.08700741000)+1 种基金the Leading Academic Discipline Project of Shanghai Education Commission (Grant No.J50104)the Innovation Foundation Project of Shanghai University
文摘A novel test access mechanism (TAM) architecture with multi test-channel (TC) based on IEEE Standard 1500 is proposed instead of the traditional sub-TAM structure. The cost model of an area-time associated test and the corresponding lower bound of system-on-chip (SoC) test time are established based on this TAM architecture. The model provides a more reliable method to control the SoC scheduling and reduces the complexity in related algorithm research. The result based on the area time associated test cost model has been validated using the ITC02 test benchmark.
文摘Effectiveness and safety of a sports mouthguard depend on its thickness and material, and the thermoforming process affects these. The purpose of this study was to clarify the effects of differences in molding mechanisms on the lower molding temperature limit and molding time in dental thermoforming. Ethylene vinyl acetate resin mouthguard sheet and two thermoforming machines;vacuum blower molding machine and vacuum ejector/pressure molding machine were used. The molding pressures for suction molding were −0.018 MPa for vacuum blower molding and −0.090 MPa for vacuum ejector molding, and for pressure molding was set to 0.090 MPa or 0.450 MPa. Based on the manufacturer’s standard molding temperature of 95˚C, the molding temperature was lowered in 2.5˚C increments to determine the lower molding temperature limit at which no molding defects occurred. In order to investigate the difference in molding time depending on the molding mechanism, the duration of molding pressure was adjusted in each molding machine, and the molding time required to obtain a sample without molding defects was measured. The molding time of each molding machine were compared using one-way analysis of variance. The lower molding temperature limit was 90.0˚C for the vacuum blower machine, 77.5˚C for the vacuum ejector machine, 77.5˚C for the pressure molding machine at 0.090 MPa, and 67.5˚C for the pressure molding machine at 0.45 MPa. The lower molding temperature limit was higher for lower absolute values of molding pressure. The molding time was shorter for pressure molding than for suction molding. Significant differences were observed between all conditions except between the pressure molding machine at 0.090 MPa and 0.45 MPa (P < 0.01). A comparison of the differences in lower molding temperature limit and molding time due to molding mechanisms in dental thermoforming revealed that the lower molding temperature limit depends on the molding pressure and that the molding time is longer for suction molding than for pressure molding.
基金supported by the National Natural Science Foundation of China (60372081)China Postdoctoral Science Foundation (20070410347)the Doctor Startup Fund of Liaoning Province (20071076)
文摘The traditional HB-weighted time-delay estimation (TDE) method degenerates under the impulsive noise environment. Two new time-delay estimation methods are proposed based on fractional lower order statistics (FLOS) according to the impulsive characteristics of fractional lower order α-stable noises. Theoretic analysis and computer simulations indicate that the proposed covariation based HB weighted (COV-HB) algorithm can suppress impulsive noises in one received signal for 1 ≤α≤ 2, whereas the other proposed fractional lower order eovariancebased HB weighted (FLOC-HB) algorithm has robust performance under arbitrary impulsive noise conditions for the whole range of 0 〈α≤ 2.
基金co-supported by the Shanghai Aerospace Science and Technology Innovation Fund of China(No.SAST2015028)the Equipment Prophecy Fund of China(No.9140A21040115KG01001)
文摘The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the TOI of multiple scan cycles into the direction difference of arrival(DDOA) model,the observability analysis for the TMA problem is performed.Some necessary conditions for uniquely identifying the scanning emitter trajectory are obtained.This paper also proposes a weighted instrumental variable(WIV) estimator for the scanning emitter TMA,which does not require any initial solution guess and is closed-form and computationally attractive.More importantly,simulations show that the proposed algorithm can provide estimation mean square error close to the Cramer-Rao lower bound(CRLB) at moderate noise levels with significantly lower estimation bias than the conventional pseudo-linear least square(PLS) estimator.
文摘Synchronization with lower SNR hadn't been considered by the conventional publications. Based on the Synchronized multi-carrier CDMA plus (SMCC+) system, which is one of the candidate schemes of digital terrestrial TV broadcasting (DTTB) standard in China, a scheme under lower SNR with one short training sequence and one Barker code group, which were constructed in time domain. Computer simulation results show that the timing estimator here is designed to avoid the ambiguity which occured in Tufvesson's timing synchronization method. The 99.9% correct timing synchronization probability and lower false probability are got in AWGN and Rayleigh fading channels with SNR under -20 dB, and the optimum properties of frequency synchronization are obtained at the same time. It is shown that the proposed scheme is much better than the conventional synchronization methods.