期刊文献+
共找到829,139篇文章
< 1 2 250 >
每页显示 20 50 100
Optimum Operation of Low-Voltage AC/DC Distribution Areas with Embedded DC Interconnections under Three-Phase Unbalanced Compensation Conditions
1
作者 Zhukui Tan Dacheng Zhou +4 位作者 Song Deng Jikai Li Zhuang Wu Qihui Feng Xuan Zhang 《Energy Engineering》 2026年第3期81-95,共15页
This paper presents an optimal operation method for embedded DC interconnections based on low-voltage AC/DC distribution areas(EDC-LVDA)under three-phase unbalanced compensation conditions.It can optimally determine t... This paper presents an optimal operation method for embedded DC interconnections based on low-voltage AC/DC distribution areas(EDC-LVDA)under three-phase unbalanced compensation conditions.It can optimally determine the transmission power of the DC and AC paths to simultaneously improve voltage quality and reduce losses.First,considering the embedded interconnected,unbalanced power structure of the distribution area,a power flow calculation method for EDC-LVDA that accounts for three-phase unbalanced compensation is introduced.This method accurately describes the power flow distribution characteristics under both AC and DC power allocation scenarios.Second,an optimization scheduling model for EDC-LVDA under three-phase unbalanced conditions is developed,incorporating network losses,voltage quality,DC link losses,and unbalance levels.The proposed model employs an improved particle swarm optimization(IPSO)two-layer algorithm to autonomously select different power allocation coefficients for the DC link and AC section under various operating conditions.This enables embedded economic optimization scheduling while maintaining compensation for unbalanced conditions.Finally,a case study based on the IEEE 13-node system for EDC-LVDA is conducted and tested.The results show that the proposed optimal operation method achieves a 100%voltage compliance rate and reduces network losses by 13.8%,while ensuring three-phase power balance compensation.This provides a practical solution for the modernization and upgrading of low-voltage power grids. 展开更多
关键词 Power loss optimization low-voltage AC/DC distribution areas embedded DC interconnections
在线阅读 下载PDF
Research on Energy Mutual Assistance Control Strategy between Low-Voltage Stations Using Micro-Pumped Storage System with Common Reservoir Mode
2
作者 Yunzhao Wu Guanglin Sha +4 位作者 Qing Duan Xinwei Cong Lu Liu Ning Zhou Yingjie Zhou 《Energy Engineering》 2025年第3期1093-1112,共20页
To enhance energy interaction among low-voltage stations(LVSs)and reduce the line loss of the distribution network,a novel operation mode of the micro-pumped storage system(mPSS)has been proposed based on the common r... To enhance energy interaction among low-voltage stations(LVSs)and reduce the line loss of the distribution network,a novel operation mode of the micro-pumped storage system(mPSS)has been proposed based on the common reservoir.First,some operation modes of mPSS are analyzed,which include the separated reservoir mode(SRM)and common reservoir mode(CRM).Then,based on the SRM,and CRM,an energy mutual assistance control model between LVSs has been built to optimize energy loss.Finally,in the simulation,compared to the model without pumped storage in the LVS,the SRMand CLRMcan decrease the total energy loss by 294.377 and 432.578 kWh,respectively.The configuration of mPSS can improve the utilization rate of the new energy source generation system,and relieve the pressure of transformer capacity in the LVS.Compared with the SRM,the proposed CRM has reduced the total energy loss by 138.201 kWh,increased the new energy consumption by 161.642 kWh,and decreased the line loss by 7.271 kWh.With the efficiency of the mPSS improving,the total energy loss reduction of CRM will be 3.5 times that of SRM.Further,the CRMcan significantly reduce the reservoir capacity construction of mPSS and ismore suitable for scenarios where the capacity configuration of mPSS is limited. 展开更多
关键词 Micro pumped storage system common reservoir mode low-voltage substation area energy interaction operating mode
在线阅读 下载PDF
Enhancement of holding voltage by a modified low-voltage trigger silicon-controlled rectifier structure for electrostatic discharge protection
3
作者 陈远康 周远良 +3 位作者 蒋杰 饶庭柯 廖武刚 刘俊杰 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期514-518,共5页
A novel structure of low-voltage trigger silicon-controlled rectifiers(LVTSCRs) with low trigger voltage and high holding voltage is proposed for electrostatic discharge(ESD) protection. The proposed ESD protection de... A novel structure of low-voltage trigger silicon-controlled rectifiers(LVTSCRs) with low trigger voltage and high holding voltage is proposed for electrostatic discharge(ESD) protection. The proposed ESD protection device possesses an ESD implant and a floating structure. This improvement enhances the current discharge capability of the gate-grounded NMOS and weakens the current gain of the silicon-controlled rectifier current path. According to the simulation results, the proposed device retains a low trigger voltage characteristic of LVTSCRs and simultaneously increases the holding voltage to 5.53 V, providing an effective way to meet the ESD protection requirement of the 5 V CMOS process. 展开更多
关键词 electrostatic discharge floating n-well low-voltage trigger silicon-controlled rectifier
原文传递
Centralized PV Coordination Control Strategy for Unbalanced LV Distribution Networks Based on Sensitivity Coefficient Weights
4
作者 Xuming Hu Nan Hu +3 位作者 Na Li Xinsong Zhang Xiaocen Xue Xiuyong Yu 《Energy Engineering》 2026年第3期391-410,共20页
The dense integration of residential distributed photovoltaic(PV)systems into three-phase,four-wire low-voltage(LV)distribution networks results in reverse power flow and three-phase imbalance,leading to voltage viola... The dense integration of residential distributed photovoltaic(PV)systems into three-phase,four-wire low-voltage(LV)distribution networks results in reverse power flow and three-phase imbalance,leading to voltage violations that hinder the growth of rural distributed PV systems.Traditional voltage droop-based control methods regulate PV power output solely based on local voltage measurements at the point of PV connection.Due to a lack of global coordination and optimization,their efficiency is often subpar.This paper presents a centralized coordinated active/reactive power control strategy for PV inverters in rural LV distribution feeders with high PV penetration.The strategy optimizes residential PV inverter reactive and active power control to enhance voltage quality.It uses sensitivity coefficients derived from the inverse Jacobian matrix to assign adjustment weights to individual PV units and iteratively optimize their power outputs.The control sequence prioritizes reactive power increases;if the coefficients are below average or the inverters reach capacity,active power is curtailed until voltage issues are resolved.A simulation based on a real 37-node rural distribution network shows that the proposed method significantly reduces PV curtailment.Typical daily results indicate a curtailment rate of 1.47%,which is significantly lower than the 15.4%observed with the voltage droop-based control method.The total daily PV power output(measured every 15 min)increases from 5.55 to 6.41 MW,improving PV hosting capacity. 展开更多
关键词 low-voltage distribution network PV inverter voltage violation centralized iterative optimization control curtailment rate
在线阅读 下载PDF
Hybrid Controller for Steady Speed of Agricultural Machinery on Slopes
5
作者 WU Caicong XU Haisong GAO Xingyu 《农业机械学报》 北大核心 2026年第2期416-426,共11页
Steady speed control of agricultural machinery can improve operating quality and efficiency.To address the impact of farmland slope variations on the speed stability of unmanned operation agricultural machinery,a hybr... Steady speed control of agricultural machinery can improve operating quality and efficiency.To address the impact of farmland slope variations on the speed stability of unmanned operation agricultural machinery,a hybrid control method was proposed.This method included a hybrid controller composed of a slope-based controller and a proportional-integral-derivative(PID)controller.The speed of agricultural machinery was influenced by longitudinal forces,which were divided into two parts:one part was slope-related forces and conventional resistance,and the other was hard-to-estimate forces,such as sliding friction.For the first part,a slope-based controller was designed;for the second part,a PID controller was implemented.By combining these two controllers,the system can dynamically adjust the throttle opening and the brake master cylinder pressure,ensuring steady speed travel on sloping farmland.Simulation tests at a target speed of 7 km/h demonstrated that the proposed controller maintained a stable speed,achieving a root mean square error of 0.13 km/h and a mean absolute percentage error of 1.6%.Field tests on a practical experimental platform validated the method’s effectiveness,with results showing consistent control performance across varying slope conditions.The proposed controller demonstrated superior control performance.Experimental data verified that this method can achieve precise control of the agricultural machinery’s movement speed,meeting the stability requirements for agricultural operations. 展开更多
关键词 farmland slope PID controller steady speed control agricultural machinery unmanned operation
在线阅读 下载PDF
Prescribed-Time Active Disturbance Rejection Control for Electromagnetic Formation Flight Under Model Uncertainties and Disturbances
6
作者 SHEN Xixi MENG Bin HU Jiangping 《空间控制技术与应用(中英文)》 北大核心 2026年第1期94-102,共9页
This study investigates prescribed-time position tracking control for electromagnetic satellite formations subject to model uncertainties and external disturbances.Using the Clohessy-Wiltshire equations as the relativ... This study investigates prescribed-time position tracking control for electromagnetic satellite formations subject to model uncertainties and external disturbances.Using the Clohessy-Wiltshire equations as the relative motion dynamics model,a prescribed time output feedback control strategy is proposed.A prescribed-time extended state observer is designed to estimate the relative velocity and external disturbances.The disturbance estimates are then used as the feedforward component of the controller.Building on this framework,a novel prescribed-time active disturbance rejection control strategy for position tracking is developed via a backstepping control design.The convergence of the extended state observer and the stability of the closed-loop system are rigorously analyzed using Lyapunov stability theory.Numerical simulations are performed to validate the effectiveness of the proposed controller. 展开更多
关键词 electromagnetic formation prescribed time active disturbance rejection control output feedback control
在线阅读 下载PDF
Robust current tracking control for three-phase grid-connected inverters with LCL filter
7
作者 LIU Wei WU Ben +2 位作者 SUN Wei-jie XUE Ying CAI Feng-huang 《控制理论与应用》 北大核心 2026年第1期41-51,共11页
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons... This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters. 展开更多
关键词 grid-connected inverter internal model principle current tracking disturbance suppression robust control
在线阅读 下载PDF
PID Steering Control Method of Agricultural Robot Based on Fusion of Particle Swarm Optimization and Genetic Algorithm
8
作者 ZHAO Longlian ZHANG Jiachuang +2 位作者 LI Mei DONG Zhicheng LI Junhui 《农业机械学报》 北大核心 2026年第1期358-367,共10页
Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion... Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots. 展开更多
关键词 agricultural robot steering PID control particle swarm optimization algorithm genetic algorithm
在线阅读 下载PDF
Multi-dynamic torque coordination control strategy for a power-split hybrid electric vehicle during mode shift
9
作者 Kun Huang Weida Wang +2 位作者 Jiankang Cheng Chao Yang Changle Xiang 《Chinese Journal of Mechanical Engineering》 2026年第1期486-495,共10页
Mode shift is a special mechanism for a power-split hybrid electric vehicle(HEV)to realise electrically variable transmission,but the sudden change of equivalent inertia caused by topological configuration recombinati... Mode shift is a special mechanism for a power-split hybrid electric vehicle(HEV)to realise electrically variable transmission,but the sudden change of equivalent inertia caused by topological configuration recombination during mode shift induces a significant torque shock.Therefore,a smooth transient process,among other concerns,typically associated with this category of vehicles,is of great importance.The present research aims to introduce a novel control strategy to manage the dynamic torque of multiple power sources and therefore im-prove ride comfort.To this end,a dynamic model of the objective power-split HEV is first built.To resolve the contention between vehicle jerk and clutch friction loss,a model predictive control(MPC)combined with control allocation(CA)is then designed for the clutch-engaged phase.To reduce the torque fluctuation caused by the inertia torques of multiple power sources,a dynamic compensation control strategy(DCcs)that coordinates motorgenerator torque to compensate for the transition torque is proposed for the brake-disengaged phase.Finally,the proposed control strategy is validated by simulation and bench test,and results show great potential in reducing shift duration,torque variation,vehicle jerk and friction loss(the simulation results show decreases of 22%,39%,83%and 53%,and the experimental results show decreases of 21%,74%,77%,and 59%,re-spectively),thereby improving shift quality. 展开更多
关键词 Power-split hybrid electric vehicle Mode shift Model predictive control control allocation Dynamic compensation control
在线阅读 下载PDF
A New Inversion-free Iterative Method for Solving the Nonlinear Matrix Equation and Its Application in Optimal Control
10
作者 GAO Xiangyu XIE Weiwei ZHANG Lina 《应用数学》 北大核心 2026年第1期143-150,共8页
In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to ... In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method. 展开更多
关键词 Nonlinear matrix equation Maximal positive definite solution Inversion-free iterative method Optimal control
在线阅读 下载PDF
Constructions of Control Sequence Set for Hierarchical Access in Data Link Network
11
作者 Niu Xianhua Ma Jiabei +3 位作者 Zhou Enzhi Wang Yaoxuan Zeng Bosen Li Zhiping 《China Communications》 2026年第1期67-80,共14页
As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and ... As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and diverse communication needs.It is crucial to design control sequences with robust randomness and conflict-freeness to properly address differentiated access control in data link.In this paper,we propose a hierarchical access control scheme based on control sequences to achieve high utilization of time slots and differentiated access control.A theoretical bound of the hierarchical control sequence set is derived to characterize the constraints on the parameters of the sequence set.Moreover,two classes of optimal hierarchical control sequence sets satisfying the theoretical bound are constructed,both of which enable the scheme to achieve maximum utilization of time slots.Compared with the fixed time slot allocation scheme,our scheme reduces the symbol error rate by up to 9%,which indicates a significant improvement in anti-interference and eavesdropping capabilities. 展开更多
关键词 control sequence data link hierarchical access control theoretical bound
在线阅读 下载PDF
An intra-string distributed and inter-string decentralized control method for hybrid series-parallel microgrids
12
作者 Xiaochao Hou Jiatong He +3 位作者 Changgeng Li Zexiong Wei Kai Sun Yunwei Li 《iEnergy》 2026年第1期30-42,共13页
The hybrid series-parallel microgrid attracts more attention by combining the advantages of both the series-stacked voltage and parallel-expanded capacity.Low-voltage distributed generations(DGs)are connected in serie... The hybrid series-parallel microgrid attracts more attention by combining the advantages of both the series-stacked voltage and parallel-expanded capacity.Low-voltage distributed generations(DGs)are connected in series to form the intra-string,and then multiple strings are interconnected in parallel.For the existing control strategies,both intra-string and inter-string depend on the centralized or distributed control with high communication reliance.It has limited scalability and redundancy under abnormal conditions.Alternatively,in this study,an intra-string distributed and inter-string decentralized control framework is proposed.Within the string,a few DGs close to the AC bus are the leaders to get the string power information and the rest DGs are the followers to acquire the synchronization information through the droop-based distributed consistency.Specifically,the output of the entire string has the active power−angular frequency(ω-P)droop characteristic,and the decentralized control among strings can be autonomously guaranteed.Moreover,the secondary control is designed to realize multi-mode objectives,including on/off-grid mode switching,grid-connected power interactive management,and off-grid voltage quality regulation.As a result,the proposed method has the ability of plug-and-play capabilities,single-point failure redundancy,and seamless mode-switching.Experimental results are provided to verify the effectiveness of the proposed practical solution. 展开更多
关键词 Hybrid series-parallel microgrid Distributed control Decentralized control Power inverter
在线阅读 下载PDF
Yaw stabilization and maneuvering control of tailless flying wing by co-directional fluidic thrust vectoring
13
作者 Liu ZHANG Meng HE 《Chinese Journal of Aeronautics》 2026年第1期66-77,共12页
Fluidic Thrust Vectoring(FTV)is used for the yaw attitude control of tailless flying wing,which can significantly improve stealth performance,maneuverability and lateral/heading maneuverability.The FTV control scheme ... Fluidic Thrust Vectoring(FTV)is used for the yaw attitude control of tailless flying wing,which can significantly improve stealth performance,maneuverability and lateral/heading maneuverability.The FTV control scheme of co-directional secondary flow was designed based on a 30 kgf thrust turbojet engine,an equivalent rudder deflection control variable of Mass Flow Combination(MFC)was proposed,and a control model was established to form a FTV control system scheme,which was integrated with the flight control system of a 100 kg tailless flying wing with medium aspect ratio to achieve closed-loop control of the yaw attitude based on FTV.The heading stability augmentation and maneuvering control characteristics and time response characteristics of tailless flying wing by FTV were quantitatively studied through virtual flight test in a wind tunnel at a wind speed of 35 m/s.The results show that the control strategy based on MFC achieves bidirectional continuous and stable control of thrust vector angle in a range of±11°,and the thrust vector angle varies monotonically with MFC;the co-directional FTV realizes bidirectional continuous and stable control of the yaw attitude of tailless flying wing,without longitudinal/lateral coupling moment.The increment of the maximum yawing moment coefficient is 0.0029,the maximum yaw rate is 7.55(°)/s,and the response time of the yaw rate of the vectoring nozzle actuated by the secondary flow is about 0.06 s,which satisfies the heading stability augmentation and maneuvering control response requirements of the aircraft with statically unstable heading,and provides new control means for the heading rudderless attitude control of tailless flying wing. 展开更多
关键词 Thrust vectoring Flow control Coanda effect Flying-wing aircraft Flight tests Yaw control
原文传递
Strategic and Regional Investigation of the Exact Controllability of the Vibrating Plate Equation on a Regular Domain
14
作者 Mouhamadou NGOM Cheikh SECK 《Journal of Mathematical Research with Applications》 2026年第1期134-142,共9页
In this paper,we define for the trace operator,the solution of certain models of vibrating plates standards with initial data in a strategic region spaces of weak regularities.Indeed,we know that the notion of regiona... In this paper,we define for the trace operator,the solution of certain models of vibrating plates standards with initial data in a strategic region spaces of weak regularities.Indeed,we know that the notion of regional controllability is more adapted to systems described by dynamic systems.Regional controllability results in a strategic area were established for vibrating plates by the Hilbertian Uniqueness Method. 展开更多
关键词 exact controllability vibrating plates strategic regional control Hilbert uniqueness method
原文传递
Conceptual design and preliminary feasibility study of fluid‑driven suspended control rods for molten salt reactors
15
作者 Jin‑Tong Cao Gui‑Feng Zhu +4 位作者 Chang‑Qing Yu Ya‑Fen Liu Yang Zou Rui Yan Hong‑Jie Xu 《Nuclear Science and Techniques》 2026年第1期225-243,共19页
Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for ... Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for online fuel reprocessing.However,the fuel-salt flow results in the decay of delayed neutron precursors(DNPs)outside the core,causing fluctuations in the effective delayed neutron fraction and consequently impacting the reactor reactivity.Particularly in accident scenarios—such as a combined pump shutdown and the inability to rapidly scram the reactor—the sole reliance on negative temperature feedback may cause a significant increase in core temperature,posing a threat to reactor safety.To address these problems,this paper introduces an innovative design for a passive fluid-driven suspended control rod(SCR)to dynamically compensate for reactivity fluctuations caused by DNPs flowing with the fuel.The control rod operates passively by leveraging the combined effects of gravity,buoyancy,and fluid dynamic forces,thereby eliminating the need for an external drive mechanism and enabling direct integration within the active region of the core.Using a 150 MWt thorium-based molten salt reactor as the reference design,we develop a mathematical model to systematically analyze the effects of key parameters—including the geometric dimensions and density of the SCR—on its performance.We examine its motion characteristics under different core flow conditions and assess its feasibility for the dynamic compensation of reactivity changes caused by fuel flow.The results of this study demonstrate that the SCR can effectively counteract reactivity fluctuations induced by fuel flow within molten salt reactors.A sensitivity analysis reveals that the SCR’s average density exerts a profound impact on its start-up flow threshold,channel flow rate,resistance to fuel density fluctuations,and response characteristics.This underscores the critical need to optimize this parameter.Moreover,by judiciously selecting the SCR’s length,number of deployed units,and the placement we can achieve the necessary reactivity control while maintaining a favorable balance between neutron economy and heat transfer performance.Ultimately,this paper provides an innovative solution for the passive reactivity control in molten salt reactors,offering significant potential for practical engineering applications. 展开更多
关键词 Molten salt reactor DNP flow-induced reactivity Passive control Suspended control rod
在线阅读 下载PDF
Impact of CeO_(2) and GO on the combustion performance of HANbased electrically controlled solid propellant
16
作者 Lian Li Lirong Bao +8 位作者 Zhiwen Wang Feng Li Lai Jiang Chuntian Li Zhidong Wang Yinghua Ye Ruiqi Shen Luigi De Luca Wei Zhang 《Defence Technology(防务技术)》 2026年第2期160-171,共12页
Electrically controlled solid propellant(ECSP)offers multiple ignition and adjustable burning rate,serving as fuel for next-generation intelligent propulsion systems.To further enhance the combustion performance of EC... Electrically controlled solid propellant(ECSP)offers multiple ignition and adjustable burning rate,serving as fuel for next-generation intelligent propulsion systems.To further enhance the combustion performance of ECSP,a method utilizing electrochemical and thermal decomposition catalysts has been proposed.In this work,we investigated the combustion characteristics of hydroxylamine nitrate(HAN)-based ECSP incorporating cerium oxide(CeO_(2))and graphene oxide(GO)by using an electrically controlled combustion test system.Electrochemical impedance spectroscopy(EIS)and linear sweep voltammetry(LSV)were used to measure the electrical conductibility and overpotential of ECSP with various additives,and Tafel curves were calculated.Thermogravimetric analysis coupled with differential scanning calorimetry(TG-DSC)was employed to investigate the thermal decomposition behavior of ECSP.While the addition of CeO_(2) and GO reduced the conductivity of ECSP,both catalysts exhibited strong electrocatalytic properties and facilitated the thermal decomposition of ECSP.Between two catalysts,GO demonstrated superior electrochemical catalytic performance but weaker thermal decomposition catalytic ability than CeO_(2).The addition of catalysts significantly enhanced the combustion performance of HAN-based ECSP.Specifically,the ignition delay time was shortened by 10%~20%.CeO_(2) raised the burning rate by approximately 20%but GO exhibited a remarkable boost of 40%in burning rate at high voltage.The combination of GO and PVA produced a flame-retardant substance that negatively impacted the ignition delay of ECSP and resulted in a smaller increase in the burning rate of ECSP at low ignition voltages. 展开更多
关键词 Electrically controlled solid propellant Hydroxylamine nitrate controllable combustion Electrothermal combustion mechanism
在线阅读 下载PDF
Probabilistic fault-tolerant fuzzy control for adaptive event-triggered lane-keeping system of autonomous electric vehicles
17
作者 Guoshun Cai Guodong Yin +3 位作者 Jiwei Feng Weihua Wang Zhenwu Fang Chaobin Zhou 《Chinese Journal of Mechanical Engineering》 2026年第1期453-468,共16页
Realistic faults and failures often occur probabilistically in the lane-keeping system of autonomous electric vehicles,reducing system reliability and posing significant challenges to driving safety.To enhance the sys... Realistic faults and failures often occur probabilistically in the lane-keeping system of autonomous electric vehicles,reducing system reliability and posing significant challenges to driving safety.To enhance the system resilience,this paper proposes a novel robust fuzzy fault-tolerant control strategy that incorporates the adaptive event-trigger(AET)mechanism to realize stable,reliable,and precise lane-keeping control in the presence of multiple system uncertainties and probabilistic faults.First,to capture the uncertain and time-varying nature of tire cornering stiffness,an effective Takagi-Sugeno(T-S)fuzzy tire model is developed.Then,by employing the distribution-based probabilistic approach,two sets of unrelated random variables,random sensor and actuator faults in the control system,are modeled.Next,to improve communication efficiency and address ineluctable network-induced delays,an AET control framework with a well-designed triggering condition is established.Subsequently,a robust fuzzy output feedback fault-tolerant lane-keeping controller that satisfies the H∞per-formance is designed by using the Lyapunov-Krasovski functional method.Furthermore,the mean-square ex-ponential stability of the closed-loop system is rigorously guaranteed.Finally,real-time simulations based on Carsim/Simulink co-simulation platform under dynamic driving conditions demonstrate the feasibility and ef-fectiveness of the proposed control strategy. 展开更多
关键词 Autonomous vehicles Lane-keeping control Event-triggered control Probabilistic sensor and actuator faults Network-induced delay
在线阅读 下载PDF
Intrusion Detection Systems in Industrial Control Systems:Landscape,Challenges and Opportunities
18
作者 Tong Wu Dawei Zhou +1 位作者 Qingyu Ou Fang Luo 《Computers, Materials & Continua》 2026年第3期162-200,共39页
The increasing interconnection of modern industrial control systems(ICSs)with the Internet has enhanced operational efficiency,but alsomade these systemsmore vulnerable to cyberattacks.This heightened exposure has dri... The increasing interconnection of modern industrial control systems(ICSs)with the Internet has enhanced operational efficiency,but alsomade these systemsmore vulnerable to cyberattacks.This heightened exposure has driven a growing need for robust ICS security measures.Among the key defences,intrusion detection technology is critical in identifying threats to ICS networks.This paper provides an overview of the distinctive characteristics of ICS network security,highlighting standard attack methods.It then examines various intrusion detection methods,including those based on misuse detection,anomaly detection,machine learning,and specialised requirements.This paper concludes by exploring future directions for developing intrusion detection systems to advance research and ensure the continued security and reliability of ICS operations. 展开更多
关键词 Industrial control system industrial control system network security intrusion detection cyberspace security ICS network network security
在线阅读 下载PDF
Adaptive Grid-Interface Control for Power Coordination in Multi-Microgrid Energy Networks
19
作者 Sk.A.Shezan 《Energy Engineering》 2026年第1期91-114,共24页
Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency devia... Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments. 展开更多
关键词 Active power flow control interconnection flow controller(IFC) frequency response micro grid stability reactive power management
在线阅读 下载PDF
Sensorless Speed Control of Synchronous Reluctance Motor Using an Advanced Fictitious Flux Estimation Including Cross Coupling Effect
20
作者 Abdin Abdin Nicola Bianchi +3 位作者 Andrea Voltan Walter Faedo Piero Cazzavillan Alessandro Biason 《Energy Engineering》 2026年第3期481-495,共15页
Synchronous reluctance motors(SynRM)are widely employed in industrial applications due to their high robustness,low cost,and absence of permanent magnets.In recent years,significant research efforts have focused on im... Synchronous reluctance motors(SynRM)are widely employed in industrial applications due to their high robustness,low cost,and absence of permanent magnets.In recent years,significant research efforts have focused on improving the controllability and efficiency of SynRM.Accurate rotor position information is essential for the controller to generate appropriate current and voltage references corresponding to the desired speed and load torque.Shaft-mounted position sensors are generally undesirable because of their high cost,sensitivity to harsh operating conditions,maintenance requirements,and reduced reliability in environments characterized by high vibration.Consequently,sensorless control techniques that estimate rotor position using measured stator currents and voltages have attracted increasing attention.However,magnetic saturation,parameter nonlinearities,and cross-coupling effects significantly degrade position estimation accuracy and may compromise the stability of sensorless SynRM drives.In this paper,a nonlinear SynRM model is developed using finite element analysis(FEA)to accurately capture magnetic saturation and cross-coupling effects,thereby providing a precise representation of the machine’s electromagnetic behavior under varying load and flux conditions.A series of magnetostatic FEA simulations is performed.To reduce computational complexity,only one motor pole is analyzed by applying anti-periodic boundary conditions along the domain sides and enforcing a zero magnetic vector potential on the external stator boundary.Nonlinear iron material properties are modeled using the appropriate B-H curve.The simulations are carried out by imposing d-and q-axis current components and computing the corresponding flux linkages and electromagnetic torque.Based on these results,both apparent and incremental inductances are extracted and incorporated into the control algorithm.An advanced fictitious flux linkage method combined with a phase-locked loop(PLL)is employed for accurate rotor position estimation.Simulation results confirm that the proposed sensorless control strategy ensures stable operation and high position estimation accuracy over the entire speed range. 展开更多
关键词 Sensorless controller 1 advanced active flux 2 fictitious flux 3 magnetic cross-coupling 4 phase locked loop controller 5
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部