期刊文献+
共找到321篇文章
< 1 2 17 >
每页显示 20 50 100
Altered amplitudes of low-frequency fluctuations in primary open angle glaucoma patients:a resting-state fMRI study
1
作者 Yi Huang Hong-Dou Luo +7 位作者 Yong-Qiang Shu Feng Ouyang Yu-Ning Song Yuan-Yuan Wang Xue-Qing Yu Chan Xiong Lu Yang Xu Zhang 《International Journal of Ophthalmology(English edition)》 2026年第2期291-301,共11页
AIM:To study the relationships between amplitude of low-frequency fluctuations(ALFF)changes and clinical ophthalmic parameters in patients with primary open angle glaucoma(POAG)and analyze the diagnostic value of ALFF... AIM:To study the relationships between amplitude of low-frequency fluctuations(ALFF)changes and clinical ophthalmic parameters in patients with primary open angle glaucoma(POAG)and analyze the diagnostic value of ALFF.METHODS:Twenty-four POAG patients and 24 healthy controls(HCs)underwent resting-state functional magnetic resonance imaging(rs-fMRI).Nonparametric rank-sum tests were used to compare the ALFF values in the slow-4 and slow-5 bands,and Spearman or Pearson correlation analysis was used to assess the correlation between ALFF changes and clinical ophthalmic parameters in POAG patients.Receiver operating characteristic(ROC)curves were used to evaluate the diagnostic performance of the ALFF.RESULTS:There were 16 males in POAG patients(median age 48y)and 12 males in HCs(median age 39y).Compared with HCs,POAG patients presented increased or decreased ALFF values in different brain regions,and similar changes were observed in mild POAG patients.The ALFF values were correlated with retinal nerve fiber layer(RNFL)thickness,inner limiting membrane-retinal pigment epithelium thickness changes and the degree of visual field defects.Analysis of the diagnostic value of the ALFF via ROC curves revealed that the right medial frontal gyrus[area under the curve(AUC)=0.9063]and superior frontal gyrus(AUC=0.9097)had better diagnostic value than did the optic disc area(AUC=0.8019),visual field index(VFI%,AUC=0.8988)and macular parameters.CONCLUSION:POAG patients present altered cortical function that is significantly correlated with the optic nerve and retinal thickness and had good diagnostic value,which may reflect the underlying neuropathological mechanism of POAG. 展开更多
关键词 primary open angle glaucoma restingstate functional magnetic resonance imaging low-frequency amplitude neurodegenerative disease
原文传递
Low-frequency vibration suppression of meta-beam with softening nonlinearity
2
作者 Weixing ZHANG Dongshuo YANG Xiangying GUO 《Applied Mathematics and Mechanics(English Edition)》 2025年第6期1011-1028,共18页
In order to obtain a lower frequency band gap,this paper proposes a novel locally resonant meta-beam incorporating a softening nonlinear factor.An improved camroller structure is designed in this meta-beam to achieve ... In order to obtain a lower frequency band gap,this paper proposes a novel locally resonant meta-beam incorporating a softening nonlinear factor.An improved camroller structure is designed in this meta-beam to achieve the softening nonlinear stiffness of the local oscillators.Firstly,based on Hamilton's principle and the Galerkin method,the control equations for the coupled system are established.The theoretical band gap boundary is then derived with the modal analysis method.The theoretical results reveal that the band gap of the meta-beam shifts towards lower frequencies due to the presence of a softening nonlinear factor,distinguishing it from both linear metamaterials and those with hardening nonlinear characteristics.Then,the vibration attenuation characteristics of a finite size meta-beam are investigated through numerical calculation,and are verified by the theoretical results.Furthermore,parameter studies indicate that the reasonable design of the local oscillator parameters based on lightweight principles helps to achieve further broadband and efficient vibration reduction in the low-frequency region.Finally,a prototype of the meta-beam is fabricated and assembled,and the formations of the low-frequency band gap and the amplitude-induced band gap phenomenon are verified through experiments. 展开更多
关键词 softening nonlinearity nonlinear band gap meta-beam low-frequency vibration attenuation
在线阅读 下载PDF
4D Printing of Reconfigurable Acoustic Metamaterials with Multiband Low-Frequency Absorption
3
作者 Jiajie Luo Junxiang Fan +7 位作者 Bo Song Yintang Wen Xiaobo Wang Lei Zhang Yonggang Yao Xiao Xiang Xuefeng Zhu Yusheng Shi 《Additive Manufacturing Frontiers》 2025年第1期18-28,共11页
Controlling low-frequency noise presents a significant challenge for traditional sound absorption materials,such as foams and fibrous substances.Recently developed acoustic absorption metamaterials,which rely on local... Controlling low-frequency noise presents a significant challenge for traditional sound absorption materials,such as foams and fibrous substances.Recently developed acoustic absorption metamaterials,which rely on local resonance can effectively balance the volume occupation and low-frequency absorption performance.However,these materials often exhibit a very narrow and fixed absorption band.Inspired by Helmholtz resonators and bistable structures,we propose bistable reconfigurable acoustic metamaterials(BRAMs)that offer multiband low-frequency absorption.These BRAMs are fabricated using shape-memory polylactic acid(SM-PLA)via four-dimension(4D)printing technology.Consequently,the geometry and absorption performance of the BRAMs can be adjusted by applying thermal stimuli(at 55℃)to switch between two stable states.The BRAMs demonstrate excellent low-frequency absorption with multiband characteristics,achieving an absorption coefficient of 0.981 at 136 Hz and 0.998 at 230 Hz for stable state I,and coefficients of 0.984 at 156 Hz and 0.961 at 542 Hz for stable state II.It was found that the BRAMs with different inclined plate angles had linear recovery stages,and the recovery speeds range from 0.75 mm/s to 1.1 mm/s.By combining a rational structural design and 4D printing,the reported reconfigurable acoustic metamaterials will inspire further studies on the design of dynamic and broadband absorption devices. 展开更多
关键词 4D printing low-frequency absorption Bistable structure Acoustic metamaterials
在线阅读 下载PDF
Lightweight multifunctional metamaterial with low-frequency vibroacoustic reduction and load-bearing performances
4
作者 Qi JIA Dianlong YU +1 位作者 Donghai HAN Jihong WEN 《Applied Mathematics and Mechanics(English Edition)》 2025年第3期403-422,共20页
Metamaterials can control and manipulate acoustic/elastic waves on a subwavelength scale using cavities or additional components.However,the large cavity and weak stiffness components of traditional metamaterials may ... Metamaterials can control and manipulate acoustic/elastic waves on a subwavelength scale using cavities or additional components.However,the large cavity and weak stiffness components of traditional metamaterials may cause a conflict between vibroacoustic reduction and load-bearing capacity,and thus limit their application.Here,we propose a lightweight multifunctional metamaterial that can simultaneously achieve low-frequency sound insulation,broadband vibration reduction,and excellent load-bearing performance,named as vibroacoustic isolation and bearing metamaterial(VIBM).The advent of additive manufacturing technology provides a convenient and reliable method for the fabrication of VIBM samples.The results show that the compressive strength of the VIBM is as high as 9.71 MPa,which is nearly 87.81%higher than that of the conventional grid structure(CGS)under the same volume fraction.Moreover,the vibration and sound transmission are significantly reduced over a low and wide frequency range,which agrees well with the experimental data,and the reduction degree is obviously larger than that obtained by the CGS.The design strategy can effectively realize the key components of metamaterials and improve their application scenarios. 展开更多
关键词 multifunctional metamaterial low-frequency sound insulation broadband vibration reduction load bearing
在线阅读 下载PDF
Low-frequency chatter suppression in robotic milling using Magnetorheological Joint Damper(MRJD)
5
作者 Shihao XIN Xiaowei TANG +3 位作者 Jiawei WU Fangyu PENG Rong YAN Kai SUN 《Chinese Journal of Aeronautics》 2025年第3期521-543,共23页
Low-frequency structural vibrations caused by poor rigidity are one of the main obstacles limiting the machining efficiency of robotic milling.Existing vibration suppression strategies primarily focus on passive vibra... Low-frequency structural vibrations caused by poor rigidity are one of the main obstacles limiting the machining efficiency of robotic milling.Existing vibration suppression strategies primarily focus on passive vibration absorption at the robotic end and feedback control at the joint motor.Although these strategies have a certain vibration suppression effect,the limitations of robotic flexibility and the extremely limited applicable speed range remain to be overcome.In this study,a Magnetorheological Joint Damper(MRJD)is developed.The joint-mounted feature ensures machining flexibility of the robot,and the millisecond response time of the Magnetorheological Fluid(MRF)ensures a large effective spindle speed range.More importantly,the evolution law of the damping performance of MRJD was revealed based on a low-frequency chatter mechanism,which guarantees the application of MRJD in robotic milling machining.To analyze the influence of the robotic joint angle on the suppression effect of the MRJD,the joint braking coefficient and end braking coefficient were proposed.Parallel coordinate plots were used to visualize the joint range with the optimal vibration suppression effect.Finally,a combination of different postures and cutting parameters was used to verify the vibration suppression effect and feasibility of the joint angle optimization.The experimental results show that the MRJD,which directly improves the joint vibration resistance,can effectively suppress the low-frequency vibration of robotic milling under a variety of cutting conditions. 展开更多
关键词 Magnetorheological fluids Joint damper Vibration suppressioni low-frequency chatter Robotic milling
原文传递
Detection and Tracking of a UAV Based on Low-Frequency Communication Network
6
作者 Hongmei Shi Yifan Zhou +1 位作者 Mengxin Yang Dan Zeng 《Journal of Beijing Institute of Technology》 2025年第3期231-242,共12页
When tracking a unmanned aerial vehicle(UAV)in complex backgrounds,environmen-tal noise and clutter often obscure it.Traditional radar target tracking algorithms face multiple lim-itations when tracking a UAV,includin... When tracking a unmanned aerial vehicle(UAV)in complex backgrounds,environmen-tal noise and clutter often obscure it.Traditional radar target tracking algorithms face multiple lim-itations when tracking a UAV,including high vulnerability to target occlusion and shape variations,as well as pronounced false alarms and missed detections in low signal-to-noise ratio(SNR)envi-ronments.To address these issues,this paper proposes a UAV detection and tracking algorithm based on a low-frequency communication network.The accuracy and effectiveness of the algorithm are validated through simulation experiments using field-measured point cloud data.Additionally,the key parameters of the algorithm are optimized through a process of selection and comparison,thereby improving the algorithm's precision.The experimental results show that the improved algo-rithm can significantly enhance the detection and tracking performance of the UAV under high clutter density conditions,effectively reduce the false alarm rate and markedly improve overall tracking performance metrics. 展开更多
关键词 unmanned aerial vehicl(UAV)detection and tracking low-frequency communication network field-measurement data
在线阅读 下载PDF
Analyzing the Efficacy of Combining Meridian Flow Low-Frequency Therapy Instrument with Chinese Herbal Enema for the Treatment of Acute and Chronic Pelvic Inflammatory Disease
7
作者 Jianfen Bu Miao Hui Yanqun Huang 《Journal of Clinical and Nursing Research》 2025年第12期286-292,共7页
Objective:To study the clinical efficacy of applying the Meridian Flow Low-Frequency Therapy Device combined with Chinese herbal enema for patients with acute and chronic pelvic inflammatory disease(PID).Methods:Sixty... Objective:To study the clinical efficacy of applying the Meridian Flow Low-Frequency Therapy Device combined with Chinese herbal enema for patients with acute and chronic pelvic inflammatory disease(PID).Methods:Sixty-two patients with acute and chronic PID admitted from January 2024 to October 2025 were selected and randomly divided into a standard group(n=31)and an experimental group(n=31).The standard group received conventional medication+Chinese herbal enema treatment.The experimental group received the Meridian Flow Low-Frequency Therapy Device in addition to the standard group’s treatment.The clinical efficacy,changes in inflammatory markers,and pelvic improvement were compared between the two groups.Results:The excellent-good rate of treatment in the experimental group was higher than that in the standard group(p<0.05).The levels of various inflammatory factors in the experimental group were lower than those in the standard group(all p<0.05).The improvement in pelvic mass diameter and pelvic effusion depth in the experimental group was superior to that in the standard group(both p<0.05).Conclusion:The Meridian Flow Low-Frequency Therapy Device combined with Chinese herbal enema has a definite curative effect in treating pelvic inflammatory disease.It can effectively alleviate clinical symptoms,reduce inflammatory response,and promote the improvement of the pelvic environment. 展开更多
关键词 Acute and chronic pelvic inflammatory disease Meridian flow low-frequency therapy device Chinese herbal enema
暂未订购
Low-Frequency Sweep Design—A Case Study in Middle East Desert Environments
8
作者 Qi Yong-fei Wei Zhou-hong +7 位作者 Nie Ming-tao Li Guo-fa Wang Tao Ling Hai Cong Sheng-kui Chen Xin-yang Duan Chang-ping Liu Yang 《Applied Geophysics》 2025年第1期71-83,233,共14页
Low-frequency vibroseis acquisition has become a routine operation in land seismic surveys,given the advantages of low-frequency signals in characterizing geological structures and enhancing the imaging of deep explor... Low-frequency vibroseis acquisition has become a routine operation in land seismic surveys,given the advantages of low-frequency signals in characterizing geological structures and enhancing the imaging of deep exploration targets.The two key points of low-frequency sweep design techniques include controlling the distortion and improving the output energy during the low-frequency stage.However,the vibrators are limited by the maximum fl ow provided by the hydraulic systems at the low-frequency stage,causing difficulty in satisfying exploration energy requirements.Initially,a theoretical analysis of the low-frequency acquisition performance of vibrators is conducted.A theoretical maximum output force below 10 Hz is obtained by guiding through theoretical formulas and combining actual vibrator parameters.Then,the signal is optimized according to the surface characteristics of the operation area.Finally,detailed application quality control and operational procedures are established.The new low-frequency sweep design method has overcome the maximum flow limitations of the hydraulic system,increased the low-frequency energy,and achieved broadband acquisition.The designed signal has been tested and applied on various types of ground surfaces in the Middle East desert region,yielding good performance.The proposed low-frequency sweep design method holds considerable value for the application of conventional vibroseis in low-frequency acquisition. 展开更多
关键词 VIBROSEIS low-frequency sweep design
在线阅读 下载PDF
Low-frequency data analysis and expansion 被引量:13
9
作者 张军华 张彬彬 +2 位作者 张在金 梁鸿贤 葛大明 《Applied Geophysics》 SCIE CSCD 2015年第2期212-220,275,共10页
The use of low-frequency seismic data improves the seismic resolution, and the imaging and inversion quality. Furthermore, low-frequency data are applied in hydrocarbon exploration; thus, we need to better use low-fre... The use of low-frequency seismic data improves the seismic resolution, and the imaging and inversion quality. Furthermore, low-frequency data are applied in hydrocarbon exploration; thus, we need to better use low-frequency data. In seismic wavelets, the loss of low-frequency data decreases the main lobe amplitude and increases the first side lobe amplitude and results in the periodic shocking attenuation of the secondary side lobe. The loss of low frequencies likely produces pseudo-events and the false appearance of higher resolution. We use models to examine the removal of low-frequency data in seismic data processing. The results suggest that the removal of low frequencies create distortions, especially for steep structures and thin layers. We also perform low-frequency expansion using compressed sensing and sparse constraints and develop the corresponding module. Finally, we apply the proposed method to real common image point gathers with good results. 展开更多
关键词 seismic wavelet forward modeling low-frequency expansion compressed sensing sparse constraint
在线阅读 下载PDF
Numerical simulation of seismic low-frequency shadows and its application 被引量:27
10
作者 贺振华 熊晓军 边立恩 《Applied Geophysics》 SCIE CSCD 2008年第4期301-306,共6页
Strong low-frequency energy beneath a hydrocarbon reservoir is called a seismic low-frequency shadow and can be used as a hydrocarbon indicator (Tarter et al., 1979) bu the physical mechanism of the observed low-fre... Strong low-frequency energy beneath a hydrocarbon reservoir is called a seismic low-frequency shadow and can be used as a hydrocarbon indicator (Tarter et al., 1979) bu the physical mechanism of the observed low-frequency shadow is still unclear. To stud) the mechanism, we performed seismic numerical simulation of geological models with a hydrocarbon-bearing zone using the 2-D diffusive-viscous wave equation which car effectively model the characteristics of velocity dispersion and transform the seismic dat~ centered in a target layer slice within a time window to the time-frequency domain by usinl time-frequency signal analysis and sort the frequency gathers to common frequency cubes. Then, we observe the characteristics of the seismic low-frequency shadow in the common frequency cubes. The numerical simulations reveal that the main mechanism of seismic lowfrequency shadows is attributed to high attenuation of the medium to high seismic frequency components caused by absorption in the hydrocarbon-filled reservoir. Results from a practical example of seismic low-frequency shadows show that it is possible to identify the reservoir by the low-frequency shadow with high S/N seismic data. 展开更多
关键词 seismic low-frequency shadow numerical simulation diffusive-viscous waveequation velocity dispersion reservoir identification
在线阅读 下载PDF
Seismic low-frequency-based calculation of reservoir fluid mobility and its applications 被引量:11
11
作者 陈学华 贺振华 +2 位作者 朱四新 刘伟 钟文丽 《Applied Geophysics》 SCIE CSCD 2012年第3期326-332,362,共8页
Low frequency content of seismic signals contains information related to the reservoir fluid mobility. Based on the asymptotic analysis theory of frequency-dependent reflectivity from a fluid-saturated poroelastic med... Low frequency content of seismic signals contains information related to the reservoir fluid mobility. Based on the asymptotic analysis theory of frequency-dependent reflectivity from a fluid-saturated poroelastic medium, we derive the computational implementation of reservoir fluid mobility and present the determination of optimal frequency in the implementation. We then calculate the reservoir fluid mobility using the optimal frequency instantaneous spectra at the low-frequency end of the seismic spectrum. The methodology is applied to synthetic seismic data from a permeable gas-bearing reservoir model and real land and marine seismic data. The results demonstrate that the fluid mobility shows excellent quality in imaging the gas reservoirs. It is feasible to detect the location and spatial distribution of gas reservoirs and reduce the non-uniqueness and uncertainty in fluid identification. 展开更多
关键词 fluid mobility seismic low-frequency reservoir characterization fluid identification instantaneous spectral decomposition
在线阅读 下载PDF
Heat transfer behavior of AZ80-1%Y alloy during low-frequency electromagnetic casting 被引量:6
12
作者 宝磊 张志强 +2 位作者 乐启炽 茹利利 崔建忠 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第11期3618-3624,共7页
Heat transfer behaviors of AZ80?1%Y alloy during low frequency electromagnetic casting (LFEC) and direct chilling casting were studied by in-situ temperature measurement. The results demonstrated that the low frequenc... Heat transfer behaviors of AZ80?1%Y alloy during low frequency electromagnetic casting (LFEC) and direct chilling casting were studied by in-situ temperature measurement. The results demonstrated that the low frequency electromagnetic field (EM) caused forced convection in the melt during LFEC. The forced convection led to uniform solidification velocity and temperature field. EM frequency, excitation current intensity and casting temperature could control the heat transfer behavior. The forced convection could improve the microstructure and degrade the difference in microstructure between the edge and center of billet. Appropriate parameters of low frequency EM for casting Mg alloy are 20 Hz of frequency and 60 A of electric current intensity. 展开更多
关键词 magnesium alloy low-frequency electromagnetic casting heat transfer behavior SOLIDIFICATION in-situ temperature measurement
在线阅读 下载PDF
Passive-source multitaper-spectral method based low-frequency data reconstruction for active seismic sources 被引量:3
13
作者 张盼 韩立国 +2 位作者 周岩 许卓 葛奇鑫 《Applied Geophysics》 SCIE CSCD 2015年第4期585-597,629,630,共15页
Passive seismic data contain large amounts of low-frequency information. To effectively extract and compensate active seismic data that lack low frequencies, we propose a multitaper spectral reconstruction method base... Passive seismic data contain large amounts of low-frequency information. To effectively extract and compensate active seismic data that lack low frequencies, we propose a multitaper spectral reconstruction method based on multiple sinusoidal tapers and derive equations for multisource and multitrace conditions. Compared to conventional cross correlation and deconvolution reconstruction methods, the proposed method can more accurately reconstruct the relative amplitude of recordings. Multidomain iterative denoising improves the SNR of retrieved data. By analyzing the spectral characteristics of passive data before and after reconstruction, we found that the data are expressed more clearly after reconstruction and denoising. To compensate for the low-frequency information in active data using passive seismic data, we match the power spectrum, supplement it, and then smooth it in the frequency domain. Finally, we use numerical simulation to verify the proposed method and conduct prestack depth migration using data after low-frequency compensation. The proposed power-matching method adds the losing low frequency information in the active seismic data using the low-frequency information of passive- source seismic data. The imaging of compensated data gives a more detailed information of deep structures. 展开更多
关键词 Passive source multitaper spectral reconstruction low-frequency compensation power matching
在线阅读 下载PDF
Low-frequency sparse double-constrained broadband seismic impedance inversion
14
作者 Wen Xiaotao Yang Jixin +2 位作者 Li Leihao He Jian Li Bo 《Natural Gas Industry B》 2019年第6期556-563,共8页
The reflection coefficient solved by using the traditional impedance inversion method cannot reflect low-frequency information sufficiently and its continuity and resolution are limited,so the quality and resolution o... The reflection coefficient solved by using the traditional impedance inversion method cannot reflect low-frequency information sufficiently and its continuity and resolution are limited,so the quality and resolution of impedance inversion are impacted seriously.In this paper,the advantages of rich low-frequency signals were discussed with the theoretical synthetic seismogram and wavelet simulation as the fulcrum.Then,the low-frequency sparse double-constrained reflection coefficient method was introduced to modify the sparse optimization item,and thus a new method was formed.Finally,based on the broadband data and non-broadband data of the actual work area,the reflection coefficient and impedance inversion solved by the traditional basis-pursuit reflection coefficient inversion were compared and then the calculation results of low-frequency sparse double-constrained reflection coefficient inversion were compared to verify the effect of the modified method.And the following research results were obtained.First,the broadband data with rich low-frequency information is less affected by the side lobe,and its seismic data resolution is higher,which is more favorable for the improvement of inversion accuracy and resolution.Second,in the new method,the L2 norm low-frequency model is added on the basis of the BPDN basis-pursuit denoising problem to constrain the residual,so as to realize the direct solution of the reflection coefficient with low-frequency information.Third,the reflection coefficient and wave impedance solved by using the new method have better continuity and resolution than those solved by using the traditional method and they are in good agreement with the well data.In conclusion,the new method achieves higher resolution on the impedance inversion of broadband data and non-broadband data and the accuracy of impedance inversion is increased,so it has higher application values in predicting the distribution of thin reservoirs. 展开更多
关键词 Compressed sensing low-frequency information Impedance inversion BROADBAND low-frequency constraint Reflection coefficient High resolution South China Sea area
在线阅读 下载PDF
Advances in low-frequency ultrasound combined with microbubbles in targeted tumor therapy 被引量:15
15
作者 Li-ying WANG Shu-sen ZHENG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2019年第4期291-299,共9页
The development of low-frequency ultrasound imaging technology and the improvement of ultrasound contrast agent production technology mean that they play an increasingly important role in tumor therapy. The interactio... The development of low-frequency ultrasound imaging technology and the improvement of ultrasound contrast agent production technology mean that they play an increasingly important role in tumor therapy. The interaction between ultrasound and microbubbles and their biological effects can transfer and release microbubbles carrying genes and drugs to target tissues, mediate the apoptosis of tumor cells, and block the embolization of tumor microvasculature. With the optimization of ultrasound parameters, the development of targeted microbubbles, and the emergence of various composite probes with both diagnostic and therapeutic functions, low-frequency ultrasound combined with microbubble contrast agents will bring new hope for clinical tumor treatment. 展开更多
关键词 low-frequency ultrasound MICROBUBBLE Gene DRUG Cell death
原文传递
Strength weakening effect of high static pre-stressed granite subjected to low-frequency dynamic disturbance under uniaxial compression 被引量:15
16
作者 Wu-xing WU Feng-qiang GONG Quan JIANG 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2022年第7期2353-2369,共17页
This study aimed to elucidate the strength weakening effect of high static pre-stressed rocks subjected to low-frequency disturbances under uniaxial compression.Based on the uniaxial compressive strength(UCS)of granit... This study aimed to elucidate the strength weakening effect of high static pre-stressed rocks subjected to low-frequency disturbances under uniaxial compression.Based on the uniaxial compressive strength(UCS)of granite under static loading,70%,80%,and 90%of UCS were selected as the initial high static pre-stress(σ_(p)),and then the pre-stressed rock specimens were disturbed by sinusoidal stress with amplitudes of 30%,20%,and 10%of UCS under low-frequency frequencies(f)of 1,2,5,and 10 Hz,respectively.The results show that the rockburst failure of pre-stressed granite is caused by low-frequency disturbance,and the failure strength is much lower than UCS.When theσp or f is constant,the specimen strength gradually decreases as the f or σ_(p) increases.The experimental study illustrates the influence mechanism of the strength weakening effect of high static pre-stress rocks under low-frequency dynamic disturbance,that is,high static pre-stress is the premise and leading factor of rock strength weakening,while low-frequency dynamic disturbance induces rock failure and affects the strength weakening degree. 展开更多
关键词 deep rock high static pre-stress low-frequency dynamic disturbance strength weakening effect uniaxial compression ROCKBURST
在线阅读 下载PDF
Effect of Acupuncture Cooperated with Low-frequency Repetitive Transcranial Magnetic Stimulation on Chronic Insomnia: A Randomized Clinical Trial 被引量:30
17
作者 Yang-pu ZHANG Wei-jing LIAO Wen-guang XIA 《Current Medical Science》 SCIE CAS 2018年第3期491-498,共8页
The effect of acupuncture cooperated with low-frequency repetitive transcranial magnetic stimulation (rTMS) on chronic insomnia was explored. Seventy-eight patients with chronic insomnia were randomly allocated into... The effect of acupuncture cooperated with low-frequency repetitive transcranial magnetic stimulation (rTMS) on chronic insomnia was explored. Seventy-eight patients with chronic insomnia were randomly allocated into two groups: treatment group and control group. In the treatment group, the patients received acupuncture combined with rTMS treatment, and those in the control group were given acupuncture cooperated with sham rTMS treatment, 3 days per week for 4 weeks. Before and after treatment, the primary outcomes including the scores on Insomnia Severity Index (ISI) and Pittsburgh Sleep Quality Index (PSQI) and the secondary outcomes including total sleep time (TST), sleep onset latency (SOL), wake after sleep onset (WASO), sleep efficiency (SE%) recorded by sleeping diary and actigraphy were observed in both groups. Seventy-five participants finished the study (38 in treatment group and 37 in control group respectively). After treatment, the scores in the two groups were improved significantly, more significantly in the treatment group than in the control group. It can be inferred that acupuncture cooperated with rTMS can effectively improve sleep quality, enhance the quality of life of patients and has less side effects. 展开更多
关键词 ACUPUNCTURE low-frequency repetitive transcranial magnetic stimulation INSOMNIA
暂未订购
Analysis of the Characteristics of 30-60 Day Low-Frequency Oscillation over Asia during 1998 SCSMEX 被引量:19
18
作者 陈隆勋 祝从文 +1 位作者 王文 张培群 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2001年第4期623-638,共16页
The wavelet analysis is performed of the mid- and low-latitude circulation index at 850 hPa over East Asia, the East Asian monsoon index and the precipitation over the middle and lower reaches of the Yangtze River dur... The wavelet analysis is performed of the mid- and low-latitude circulation index at 850 hPa over East Asia, the East Asian monsoon index and the precipitation over the middle and lower reaches of the Yangtze River during 1998 South China Sea Monsoon Experiment (SCSMEX) from May to August. Analysis shows that distinct 30-60 day low-frequency oscillation (LFO) exists in all of the above elements during the experiment period. Analysis of low-frequency wind field at 850 hPa from May to August with 5 days interval is performed in this Paper. Analysis results reveal that: (l ) A low-frequency monsoon circulation system over East Asia, characterized by distinct 30-60 day low-frequency oscillation, exists over 100°-150°E of East Asian area from the middle and eastern parts of China continent and the South China Sea to the western Pacific in both the Northern and Southern Hemisphere. The activity of East Asian monsoon is mainly affected by the low-frequency systems in it; (2) All of the tropical monsoon onset over the South China Sea in the fifth pentad of May, the beginning of the Meiyu period and heavy rainfall over the middle and lower reaches of the Yangtze River in mid-June and the heavy rainfall after mid-July are related to the activity of low-frequency cyclone belt over the region, whereas the torrential rainfall over the upper reaches of the Yangtze River in August is associated with the westward propagation of low-frequency anticyclone into the mainland; (3) There are two sources of low-frequency oscillation system over East Asia during SCSMEX. i.e. the equatorial South China Sea (SCS) and mid-high latitudes of the middle Pacific in the Northern Hemisphere. The low-frequency system over SCS propagates northward while that in mid-high latitudes mainly propagates from northeast to southwest. Both of the heavy rainfall over the middle and lower reaches of the Yangtze River in June and July are associated with the northward propagation of the above-mentioned SCS low-frequency systems from the tropical region and the southwestward propagation from mid-high latitudes respectively and their convergence in the middle and lower reaches of the Yangtze River; (4) There are two activities of low-frequency cyclone and anticyclone belt each in the East Asian monsoon system during May to August. However the activity of these low-frequency circulation systems is not clearly relevant to the low-frequency circulation system in the indian monsoon system. This means that the low-frequency circulation systems in indian monsoon and East Asian monsoon are independent of each other. The concept previously put forward by Chinese scholars that the East Asian monsoon circulation system (EAMCS) is relatively independent monsoon circulation system is testified once more in the summer 1998. 展开更多
关键词 SCS monsoon onset Flood in the summer 1998 low-frequency monsoon circulation
在线阅读 下载PDF
Low-frequency pulsed electromagnetic field pretreated bone marrow-derived mesenchymal stem cells promote the regeneration of crush-injured rat mental nerve 被引量:12
19
作者 NaRi Seo Sung-Ho Lee +5 位作者 Kyung Won Ju JaeMan Woo Bong Ju Kim Soung Min Kim Jeong Won Jahng Jong-Ho Lee 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第1期145-153,共9页
Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal diffe... Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal differentiation of BMSCs. Low-frequency PEMF can induce the neuronal differentiation of BMSCs in the absence of nerve growth factors. This study was designed to investigate the effects of low-frequency PEMF pretreatment on the proliferation and function of BMSCs and the effects of low-frequency PEMF pre-treated BMSCs on the regeneration of injured peripheral nerve using in vitro and in vivo experiments.In in vitro experiments, quantitative DNA analysis was performed to determine the proliferation of BMSCs, and reverse transcription-polymerase chain reaction was performed to detect S100 (Schwann cell marker), glial fibrillary acidic protein (astrocyte marker), and brain-derived neurotrophic factor and nerve growth factor (neurotrophic factors) mRNA expression. In the in vivo experiments, rat models of crush-injured mental nerve established using clamp method were randomly injected with low-frequency PEMF pretreated BMSCs, unpretreated BMSCs or PBS at the injury site (1 × 106 cells). DiI-labeled BMSCs injected at the injury site were counted under the fluorescence microscope to determine cell survival. One or two weeks after cell injection, functional recovery of the injured nerve was assessed using the sensory test with von Frey filaments. Two weeks after cell injection, axonal regeneration was evaluated using histomorphometric analysis and retrograde labeling of trigeminal ganglion neurons. In vitro experiment results revealed that low-frequency PEMF pretreated BMSCs proliferated faster and had greater mRNA expression of growth factors than unpretreated BMSCs. In vivo experiment results revealed that compared with injection of unpretreated BMSCs, injection of low-frequency PEMF pretreated BMSCs led to higher myelinated axon count and axon density and more DiI-labeled neurons in the trigeminal ganglia, contributing to rapider functional recovery of injured mental nerve. These findings suggest that low-frequency PEMF pretreatment is a promising approach to enhance the efficacy of cell therapy for peripheral nerve injury repair. 展开更多
关键词 nerve regeneration mesenchymal stem cells low-frequency pulsed electromagnetic field peripheral nerve injury crush-injured mental nerve
暂未订购
Effect of low-frequency electromagnetic field on the as-cast microstructure of a new super high strength aluminum alloy by horizontal continuous casting 被引量:7
20
作者 Yubo ZUO Jianzhong CUI +3 位作者 Yang WANG Xiaotao LIU Zhihao ZHAO Haitao Zhang 《China Foundry》 SCIE CAS 2005年第1期48-51,共4页
The super high strength aluminum alloy ingots with 100 mm in diameter were cast by the process of low-frequency electromagnetic horizontal continuous casting (LFEHC) and the effect of electromagnetic field on the as-c... The super high strength aluminum alloy ingots with 100 mm in diameter were cast by the process of low-frequency electromagnetic horizontal continuous casting (LFEHC) and the effect of electromagnetic field on the as-cast microstructure was studied. Results show that microstructure of the sample prepared by the LFEHC process was greatly refined. Microstructures at the border and the center of the ingots were fine, uniform and rosette-shaped. Electromagnetic frequency plays a key role in microstructure refining. Fine and uniform microstructures can be obtained with optimal electromagnetic frequency. In this experiment, under a frequency of 30 Hz the microstructure was the finest and the most uniform. 展开更多
关键词 low-frequency ELECTROMAGNETIC field HORIZONTAL continuous CASTING microstructure AL-ZN-MG-CU alloy
在线阅读 下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部