期刊文献+
共找到26篇文章
< 1 2 >
每页显示 20 50 100
Secure task offloading strategy optimization of UAV-aided outdoor mobile high-definition live streaming
1
作者 Ming YAN Yuxuan ZHANG +2 位作者 Chien Aun CHAN André F.GYGAX Chunguo LI 《Chinese Journal of Aeronautics》 2025年第10期201-215,共15页
Unmanned aerial vehicles(UAVs)bring more innovation and attraction to outdoor mobile high-definition(HD)live streaming with its unique perspective.Due to the heavy computational requirements of HD live broadcast tasks... Unmanned aerial vehicles(UAVs)bring more innovation and attraction to outdoor mobile high-definition(HD)live streaming with its unique perspective.Due to the heavy computational requirements of HD live broadcast tasks and the limited hardware performance of UAV equipment,how to reduce the system response delay and improve the energy efficiency of terminal equipment directly affects the secure broadcast of the system.Secure task offloading in this scenario is considered a promising solution and has received academic attention.In this paper,we simulate the UAV-aided outdoor mobile HD live streaming scenarios and optimize the relevant task offloading strategies.First,we design the total cost function of task offloading that jointly optimizes secure time latency and energy consumption.Additionally,we propose a collaborative computing model for multi-UAV task offloading.This model combines the idea of simulated annealing(SA)and introduces the compression factor to enhance the particle swarm optimization(PSO)to realize secure task offloading.The simulation results show that the proposed strategy has better performance in balancing network latency and energy consumption.Compared with the discrete teaching–learning-based optimization(DTLBO)and quantum PSO(QPSO)task offloading strategies,the fitness value of the proposed strategy is decreased by an average of 26.73%and 16.42%,respectively. 展开更多
关键词 Unmanned aerial vehicle(UAV) high-definition(HD)live streaming Secure task offloading Network energy consumption Particle swarm optimization(PSO)
原文传递
High-definition colonoscopy with i-Scan:Better diagnosis for small polyps and flat adenomas 被引量:12
2
作者 Pier Alberto Testoni Chiara Notaristefano +2 位作者 Cristian Vailati Milena Di Leo Edi Viale 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第37期5231-5239,共9页
AIM: To investigate if high-definition (HD) colonoscope with i-Scan gave a higher detection rate of mucosal le- sions vs standard white-light instruments. METHODS: Data were collected from the computer- ized datab... AIM: To investigate if high-definition (HD) colonoscope with i-Scan gave a higher detection rate of mucosal le- sions vs standard white-light instruments. METHODS: Data were collected from the computer- ized database of the endoscopy unit of our tertiary referral center. We retrospectively analyzed 1101 con- secutive colonoscopies that were performed over 1 year with standard white-light (n = 849) or HD+ with i-Scan (n = 252) instruments by four endoscopists, in an outpatient setting. Colonoscopy records included patients' main details and family history for colorectal cancer, indication for colonoscopy (screening, diagnos- tic or surveillance), type of instrument used (standard white-light or HD+ plus i-Scan), name of endoscopist and bowel preparation. Records for each procedure included whether the cecum was reached or not and the reason for failure, complications during or imme- diately after the procedure, and number, size, location and characteristics of the lesions. Polyps or protruding lesions were defined as sessile or pedunculated, and nonprotruding lesions were defined according to Paris classification. For each lesion, histological diagnosis was recorded. RESULTS: Eight hundred and forty-nine colonosco- pies were carried with the standard white-light video colonoscope and 252 with the HD+ plus i-Scan video colonoscope, The four endoscopists did 264, 300, 276 and 261 procedures, respectively; 21.6%, 24.0%, 21.7% and 24.1% of them with the HD+ plus i-Scan technique. There were no significant differences be- tween the four endoscopists in either the number of procedures done or the proportions of each imaging technique used. Both techniques detected one or more mucosal lesions in 522/1101 procedures (47.4%). The overall number of lesions recognized was 1266; 645 in the right colon and 621 in the left. A significantly higher number of colonoscopies recognized lesions in the HD+ plus i-Scan mode (171/252 = 67.9%) than with the standard white-light technique (408/849 = 48.1%) (P 〈 0.0001). HD+ with i-Scan colonoscopies identified more lesions than standard white-light imag- ing (459/252 and 807/849, P 〈 0.0001), in the right or left colon (mean :1: SD, 1.62±1.36 vs 1.33±0.73, P 〈 0.003 and 1.55±0.98 vs 1.17±0.93, P = 0.033), more lesions 〈 10 mm (P 〈 0.0001) or nonprotruding (P 〈 0.022), and flat polyps (P = 0.04). The cumulative mean number of lesions per procedure detected by the four endoscopists was significantly higher with HD+ with i-Scan than with standard white-light imaging (1.82 ± 2.89 vs 0.95± 1.35, P 〈 0.0001). CONCLUSION: HD imaging with i-Scan during the withdrawal phase of colonoscopy significantly increased the detection of colonic mucosal lesions, particularly small and nonprotruding polyps. 展开更多
关键词 COLONOSCOPY high-definition with i-Scancolonoscopy White-light colonoscopy Colonic polyps Nonprotruding lesions Adenoma detection rate With-drawal time Surface enhancement Contrast enhance-ment Tone enhancement
暂未订购
Wavelet Transform-Based High-Definition Map Construction From a Panoramic Camera 被引量:1
3
作者 ZHUANG Hanyang ZHOU Xuejun +1 位作者 WANG Chunxiang QIAN Yuhan 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第5期569-576,共8页
High-definition(HD)maps are key components that provide rich topologic and semantic information for decision-making in vehicle autonomous driving systems.A complete ground orthophoto is usually used as the base image ... High-definition(HD)maps are key components that provide rich topologic and semantic information for decision-making in vehicle autonomous driving systems.A complete ground orthophoto is usually used as the base image to construct the HD map.The ground orthophoto is obtained through inverse perspective transformation and image mosaicing.During the image mosaicing,multiple consecutive orthophotos are stitched together using pose information and image registration.In this study,wavelet transform is introduced to the image mosaicing process to alleviate the information loss caused by image overlapping.In the orthophoto wavelet transform,high-frequency and low-frequency components are fused using different strategies to form a complete base image with clearer local details.Experimental results show that the accuracy of the orthophotos generated using this method is improved. 展开更多
关键词 high-definition(HD)map wavelet transform image registration PANORAMA
原文传递
Standard-definition White-light,High-definition White-light versus Narrow-band Imaging Endoscopy for Detecting Colorectal Adenomas:A Multicenter Randomized Controlled Trial 被引量:1
4
作者 Chang-wei DUAN Hui-hong ZHAI +10 位作者 Hui XIE Xian-zong MA Dong-liang YU Lang YANG Xin WANG Yu-fen TANG Jie ZHANG Hui SU Jian-qiu SHENG Jun-feng XU Peng JIN 《Current Medical Science》 SCIE CAS 2024年第3期554-560,共7页
Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colore... Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies. 展开更多
关键词 standard-definition white-light endoscopy high-definition white-light endoscopy narrow-band imaging colonoscopy colorectal cancer screening adenoma detection rate
暂未订购
Optical diagnosis of colorectal polyps using high-definition i-scan: An educational experience
5
作者 Mariёlle WE Bouwens Rogier de Ridder +4 位作者 Ad AM Masclee Ann Driessen Robert G Riedl Bjorn Winkens Silvia Sanduleanu 《World Journal of Gastroenterology》 SCIE CAS 2013年第27期4334-4343,共10页
AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still ... AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still images, comprising twin pictures (surface enhancement and tone enhancement), collected at our university hospital. We defined endoscopic features of adenomatous and non-adenomatous polyps, according to the following parameters:color, surface pattern and vascular pattern. We familiarized the participating endoscopists on optical diagnosis of colorectal polyps using a 20-min didactic training session. All endoscopists were asked to evaluate an image set of 50 colorectal polyps with regard to polyp histology. We classified the diagnoses into high confidence (i.e., cases in which the endoscopist could assign a diagnosis with certainty) and low confidence diagnoses (i.e., cases in which the endoscopist preferred to send the polyp for formal histology). Mean sensitivity, specificity and accuracy per endoscopist/image were computed and differences between groups tested using independent-samples t tests. High vs low confidence diagnoses were compared using the pairedsamples t test. RESULTS:Eleven endoscopists without previous experience on optical diagnosis evaluated a total of 550 images (396 adenomatous, 154 non-adenomatous). Mean sensitivity, specificity and accuracy for diagnosing adenomas were 79.3%, 85.7% and 81.1%, respectively. No significant differences were found between gastroenterologists and trainees regarding performances of optical diagnosis (mean accuracy 78.0%vs 82.9%,P = 0.098). Diminutive lesions were predicted with a lower mean accuracy as compared to non-diminutive lesions (74.2% vs 93.1%, P = 0.008). A total of 446 (81.1%) diagnoses were made with high confidence. High confidence diagnoses corresponded to a significantly higher mean accuracy than low confidence diagnoses (84.0% vs 64.3%, P = 0.008). A total of 319 (58.0%) images were evaluated as having excellent quality. Considering excellent quality images in conjunction with high confidence diagnosis, overall accuracy increased to 92.8%. CONCLUSION:After a single training session, endoscopists with varying levels of experience can already provide optical diagnosis with an accuracy of 84.0%. 展开更多
关键词 COLONOSCOPY high-definition i-scan Optical diagnosis Colorectal POLYPS Training
暂未订购
A Reliable Adaptive High-Definition Transmission System for Distance Learning
6
作者 徐奇 李鹤廷 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第6期740-743,共4页
There is an increasing demand for supporting high-quality real-time audiovisual services for the next generation wired and wireless networks. However, due to variety of bandwidths of different networks, it is a great ... There is an increasing demand for supporting high-quality real-time audiovisual services for the next generation wired and wireless networks. However, due to variety of bandwidths of different networks, it is a great challenge for deployment. In this paper, a novel high-definition (HD) video transmission system was proposed which depends upon reliable compound multicast protocols and QoS control over the various kinds of networks. This system detects client's network condition and assigns it to a proper proxy. Each proxy is capable of detecting network parameters and adaptively tuning such transport parameters as bit rate, video resolution, frame rate and QoS mechanisms to this condition. It also provides FEC error recovery under consideration of characteristics of MPEG4 video codec. Our simulation demonstrates that different network clients such as ADSL, CERNET, and CERNET2 can receive more video reliability with less delay. 展开更多
关键词 ADAPTIVE high-definition(HD) transmission system distance learning RELIABLE compound MULTICAST protocol (RCMP)
在线阅读 下载PDF
Developing Projects with Low-code Combined with ChatGPT
7
作者 Wei Xiong Bing Li +1 位作者 Zhao Wu Bo Hang 《计算机教育》 2023年第12期204-213,共10页
This paper aims to explore a simpler and more user-friendly way of generating software based on model-driven development.Previous studies have attempted to generate code from domain models,hoping to reduce coding time... This paper aims to explore a simpler and more user-friendly way of generating software based on model-driven development.Previous studies have attempted to generate code from domain models,hoping to reduce coding time by increasing modeling time.However,as code tools become more advanced,it is challenging to improve efficiency because models are abstract while implementations are concrete.This paper proposes a novel approach that integrates ChatGPT as a plug-in into the whole R&D process and combines it with our code generation tool to enhance R&D efficiency.We have developed some demos to demonstrate the effectiveness of our approach.According to our evaluation,our approach can save more than 90%of the work in implementing the code generation tool,leaving only about 10%of the work for code review,code improvement,and unit testing. 展开更多
关键词 ChatGPT low-code Code generation Software engineering Project development
在线阅读 下载PDF
Software-aided efficient identification of the components of compound formulae and their metabolites in rats by UHPLC/IM-QTOF-MS and an in-house high-definition MS^(2) library: Sishen formula as a case
8
作者 Lili Hong Wei Wang +9 位作者 Shiyu Wang Wandi Hu Yuyang Sha Xiaoyan Xu Xiaoying Wang Kefeng Li Hongda Wang Xiumei Gao De-an Guo Wenzhi Yang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第10期1484-1495,共12页
Identifying the compound formulae-related xenobiotics in bio-samples is full of challenges.Conventional strategies always exhibit the insufficiencies in overall coverage,analytical efficiency,and degree of automation,... Identifying the compound formulae-related xenobiotics in bio-samples is full of challenges.Conventional strategies always exhibit the insufficiencies in overall coverage,analytical efficiency,and degree of automation,and the results highly rely on the personal knowledge and experience.The goal of this work was to establish a software-aided approach,by integrating ultra-high performance liquid chromatography/ion-mobility quadrupole time-of-flight mass spectrometry(UHPLC/IM-QTOF-MS)and in-house high-definition MS^(2) library,to enhance the identification of prototypes and metabolites of the compound formulae in vivo,taking Sishen formula(SSF)as a template.Seven different MS2 acquisition methods were compared,which demonstrated the potency of a hybrid scan approach(namely high-definition data-independent/data-dependent acquisition(HDDIDDA))in the identification precision,MS1 coverage,and MS^(2) spectra quality.The HDDIDDA data for 55 reference compounds,four component drugs,and SSF,together with the rat bio-samples(e.g.,plasma,urine,feces,liver,and kidney),were acquired.Based on the UNIFI™platform(Waters),the efficient data processing workflows were established by combining mass defect filtering(MDF)-induced classification,diagnostic product ions(DPIs),and neutral loss filtering(NLF)-dominated structural confirmation.The high-definition MS^(2) spectral libraries,dubbed in vitro-SSF and in vivo-SSF,were elaborated,enabling the efficient and automatic identification of SSF-associated xenobiotics in diverse rat bio-samples.Consequently,118 prototypes and 206 metabolites of SSF were identified,with the identification rate reaching 80.51%and 79.61%,respectively.The metabolic pathways mainly involved the oxidation,reduction,hydrolysis,sulfation,methylation,demethylation,acetylation,glucuronidation,and the combined reactions.Conclusively,the proposed strategy can drive the identification of compound formulae-related xenobiotics in vivo in an intelligent manner. 展开更多
关键词 Ultra-high performance liquid chromatography/ion-mobility quadrupole time-of-flight mass spectrometry(UHPLC/IM-QTOF-MS) Hybrid scan high-definition MS^(2)spectral library Sishen formula
暂未订购
Prospects of Using Low-Code in the Creation of Automated Systems
9
作者 Conrad Onesime Oboulhas Tsahat NGOULOU-A-NDZELI Patrick Aurélien Ampiri Kwai 《Open Journal of Applied Sciences》 2023年第10期1864-1869,共6页
Ever-changing market conditions and a rapidly changing IT landscape call for fast and cheap ways to meet software demands. In order to tackle these problems, low-code development platforms (LCDPs) have emerged. These ... Ever-changing market conditions and a rapidly changing IT landscape call for fast and cheap ways to meet software demands. In order to tackle these problems, low-code development platforms (LCDPs) have emerged. These platforms are designed with the idea to limit recurring traditional hand-coding and programming. This article provides a theoretical overview of low-code solutions. The advantages and disadvantages of using LCDP in the creation of automated systems are considered. In conclusion, a conclusion is formulated about the prospects of using low-code technology. 展开更多
关键词 low-code CODING Automated Systems low-code Development Platform
在线阅读 下载PDF
Application of Visual High-definition Rigid Bronchoscope in Removal of Complicated Respiratory Foreign Body
10
作者 HE Meng CHENG Yanbin BAO Yan 《外文科技期刊数据库(文摘版)医药卫生》 2021年第12期997-1000,共6页
Objective: to explore and analyze the effect of applying visual high-definition rigid bronchoscopy in the removal of complicated respiratory foreign body. Methods: from September 2017 to June 2020, 97 patients with co... Objective: to explore and analyze the effect of applying visual high-definition rigid bronchoscopy in the removal of complicated respiratory foreign body. Methods: from September 2017 to June 2020, 97 patients with complex foreign body in respiratory tract with valid data registered in the database of our hospital were selected as the research subjects. The basic data of the patients were statistically analyzed. All the patients in this study had complicated foreign body obstruction in respiratory tract. After admission, the medical staff gave the patients visual high-definition rigid bronchoscopy for auxiliary treatment, and the final treatment effect was evaluated and analyzed. Results: in this study, 97 patients with complex foreign body in respiratory tract were improved after treatment, with a total effective rate of 100%. In this study, there were 2 patients with respiratory tract injury during surgery, with an incidence rate of 2.06%. Conclusion: in the removal of complicated respiratory foreign body, the choice of visual high-definition rigid bronchoscope for treatment can help medical staff to identify respiratory foreign body and promote the outcome of the patient's condition, which has good promotion value and is worthy of further application. 展开更多
关键词 visual high-definition rigid bronchoscopy removal of complex respiratory foreign body treatment op
暂未订购
一种基于微组件架构的前端低代码平台 被引量:1
11
作者 张钢岭 陈聪 郭凌云 《信息技术与信息化》 2025年第3期162-165,共4页
针对传统软件开发面临开发周期长、技术门槛高、投入成本大等问题,提出一种基于微组件架构的前端低代码平台解决方案。通过将前端应用拆分为独立的、可复用的微组件,大幅降低开发难度和周期,并允许非专业开发者通过拖放和配置的方式快... 针对传统软件开发面临开发周期长、技术门槛高、投入成本大等问题,提出一种基于微组件架构的前端低代码平台解决方案。通过将前端应用拆分为独立的、可复用的微组件,大幅降低开发难度和周期,并允许非专业开发者通过拖放和配置的方式快速构建前端应用。提高了开发效率,同时保证了系统的灵活性和可扩展性。 展开更多
关键词 低代码 微组件 Single-Spa JSON Schema low-code
在线阅读 下载PDF
Advances in endoscopic dysplasia detection in inflammatory bowel disease
12
作者 Partha Pal Priyaranjan Kata +5 位作者 Zaheer Nabi Mohan Ramchandani Pramod Reddy Soma Rajesh Gupta Manu Tandan Nageshwar Reddy Duvvur 《World Journal of Gastrointestinal Endoscopy》 2025年第12期164-176,共13页
BACKGROUND Dysplasia surveillance in inflammatory bowel disease(IBD)has evolved significantly with the adoption of advanced endoscopic technologies.AIM To synthesize evidence on image-enhanced endoscopy techniques,bio... BACKGROUND Dysplasia surveillance in inflammatory bowel disease(IBD)has evolved significantly with the adoption of advanced endoscopic technologies.AIM To synthesize evidence on image-enhanced endoscopy techniques,biopsy protocols,and surveillance practices optimizing dysplasia detection in IBD.METHODS A scoping review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.A comprehensive search of PubMed and EMBASE from inception to June 2025 identified studies reporting on endoscopic dysplasia detection or characterization in IBD.Forty-five studies were included for qualitative synthesis,covering dye-based chromoendoscopy(DCE),virtual chromoendoscopy(VCE),confocal laser endomicroscopy,artificial intelligence-based tools,and panoramic endoscopy.RESULTS DCE consistently demonstrated high dysplasia detection rates,especially when indigo carmine was used,and enabled accurate pit-pattern-based lesion characterization.High definition(HD)DCE may offer procedural benefits over HD white light endoscopy(WLE),though superiority in dysplasia detection remains inconsistent across studies.In comparative studies,DCE outperformed or matched white-light approaches,with higher dysplasia yield in selected trials(e.g.,9.7%vs 1.9%,P=0.004),while HD WLE with segmental re-inspection was non-inferior to DCE in expert settings.Virtual chromoendoscopy modalities such as i-SCAN and narrow band imaging showed comparable performance to DCE in several trials,with artificial intelligence-assisted computer-aided detection systems demonstrating equivalent sensitivity but lower specificity.Studies comparing biopsy protocols revealed that targeted biopsies under imageenhanced endoscopy,particularly DCE,were generally superior or equivalent to random biopsies,with random sampling offering marginal benefit in select high-risk subgroups.Multimodal imaging and panoramic endoscopy further improved dysplasia yield in challenging cases.Cost-effectiveness analyses favored DCE over WLE,and long-term surveillance data confirmed declining colorectal cancer rates with high-quality endoscopic programs.However,real-world practice audits revealed substantial variation in surveillance quality and guideline adherence.CONCLUSION Image-enhanced targeted surveillance-particularly using DCE or validated virtual platforms-has improved dysplasia detection in IBD and may allow for a reduction in random biopsies.Despite technological advancements,major quality gaps and interobserver variability persist in clinical practice.Standardized training,quality benchmarks,and cost-effective implementation of advanced endoscopic techniques are needed to optimize colorectal cancer prevention in IBD. 展开更多
关键词 Colitis-associated neoplasia Dye-based chromoendoscopy Virtual chromoendoscopy Narrow band imaging White light endoscopy high-definition endoscopy DYSPLASIA BIOPSY
暂未订购
Assessment of the right and left ventricular function in patients with cor pulmonale using high-definition CT 被引量:7
13
作者 GAO Yan QIN Jian DU Xiang-ying YANG Jing LI Kun-cheng 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第19期3639-3644,共6页
Background Cor pulmonale is often associated with changes of structure and function of the right ventricle (RV) and thus further affects functional changes of the left heart.Our study aimed to assess the left ventri... Background Cor pulmonale is often associated with changes of structure and function of the right ventricle (RV) and thus further affects functional changes of the left heart.Our study aimed to assess the left ventricular (LV) and RV function in patients with cor pulmonale using high-definition CT (HDCT).Methods We prospectively studied 18 cor pulmonale patients determined by the pulmonary function test,clinical examination,chest radiograph,electrocardiogram,and echocardiogram.The subject group was compared to a control group consisting of 18 subjects.The RV and LV functions and RV myocardial mass (MM) were obtained by HDCT in the two groups.The results were compared between the two groups using the independent sample t test.Echocardiographic examination for cardiac function analysis was performed on the same day.Results The RV end-diastolic volume (EDV),RV end-systolic volume (ESV) and RV myocardial mass were significantly larger in the 18 cor pulmonale patients than in the control group (P〈0.05).The right ventricular ejection fraction (RVEF) was significantly lower in the 18 cor pulmonale patients than in controls (P〈0.01).The left ventricular EDV (LVEDV) and LVEF were significantly lower in cor pulmonale patients than in controls (P〈0.01).There were strong correlations between MDCT and echocardiography,rRVEF=0.839 and rLVEF=0.916,respectively.Conclusions HDCT can accurately quantify RV and LV function.The right ventricular function is impaired in patients with cor pulmonale,while at the same time the left ventricular function is also impaired. 展开更多
关键词 cor pulmonale ventricular function high-definition CT myocardial mass
原文传递
Progress on CASEarth Satellite Development 被引量:5
14
作者 GUO Huadong CHEN Hongyu +1 位作者 CHEN Liangfu FU Bihong 《空间科学学报》 CAS CSCD 北大核心 2020年第5期707-717,共11页
CASEarth satellite is the first space Earth science satellite produced by the Chinese Academy of Sciences.The satellite has three payloads:high-definition Thermal Infrared Spectrometer(TIS),highdefinition Glimmer Imag... CASEarth satellite is the first space Earth science satellite produced by the Chinese Academy of Sciences.The satellite has three payloads:high-definition Thermal Infrared Spectrometer(TIS),highdefinition Glimmer Imager for Urbanization(GIU),and high-definition Multispectral Imager for Inshore(MII).These payloads are used to explore the urbanization level and residential layout,the coastal ecosystem,and new methods and approaches of environmental detection during night-time and even under conditions of polar aurora and provide scientific evidence for the refined depiction of human traces.The CASEarth satellite can provide space observation data for A Project on Big Earth Data Science Engineering as well as scientific and application studies inside and outside China. 展开更多
关键词 CASEarth satellite Human traces Thermal infrared spectrometer high-definition glimmer imager for urbanization Multispectral imager for inshore
在线阅读 下载PDF
Automatic Lane-Level Intersection Map Generation using Low-Channel Roadside LiDAR 被引量:2
15
作者 Hui Liu Ciyun Lin +1 位作者 Bowen Gong Dayong Wu 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2023年第5期1209-1222,共14页
A lane-level intersection map is a cornerstone in high-definition(HD) traffic network maps for autonomous driving and high-precision intelligent transportation systems applications such as traffic management and contr... A lane-level intersection map is a cornerstone in high-definition(HD) traffic network maps for autonomous driving and high-precision intelligent transportation systems applications such as traffic management and control, and traffic accident evaluation and prevention. Mapping an HD intersection is time-consuming, labor-intensive, and expensive with conventional methods. In this paper, we used a low-channel roadside light detection and range sensor(LiDAR) to automatically and dynamically generate a lane-level intersection, including the signal phases, geometry, layout, and lane directions. First, a mathematical model was proposed to describe the topology and detail of a lane-level intersection. Second, continuous and discontinuous traffic object trajectories were extracted to identify the signal phases and times. Third, the layout, geometry, and lane direction were identified using the convex hull detection algorithm for trajectories. Fourth, a sliding window algorithm was presented to detect the lane marking and extract the lane, and the virtual lane connecting the inbound and outbound of the intersection were generated using the vehicle trajectories within the intersection and considering the traffic rules. In the field experiment, the mean absolute estimation error is 2 s for signal phase and time identification. The lane marking identification Precision and Recall are96% and 94.12%, respectively. Compared with the satellite-based,MMS-based, and crowdsourcing-based lane mapping methods,the average lane location deviation is 0.2 m and the update period is less than one hour by the proposed method with low-channel roadside LiDAR. 展开更多
关键词 high-definition map lane-level intersection map roadside LiDAR sliding window traffic object trajectory
在线阅读 下载PDF
QoE Assessment and Prediction Method for HighDefinition Video Stream Using Image Damage Accumulation 被引量:2
16
作者 Yang Geng Luoming Meng +2 位作者 Yao Wang Yu Yang Zhiguo Qu 《China Communications》 SCIE CSCD 2016年第7期48-59,共12页
The accuracy of the traditional assessment method of the quality of experience(Qo E) has been facing challenges with the growth of high-definition(HD) video streaming services.Image display-quality damage is the main ... The accuracy of the traditional assessment method of the quality of experience(Qo E) has been facing challenges with the growth of high-definition(HD) video streaming services.Image display-quality damage is the main factor that affects the Qo E in HD video services through UDP network transmission.In this paper,we introduce a novel objective factor known as image damage accumulation(IDA) to assess user's Qo E in HD video services.First,this paper quantitatively analyzed the effect on user quality of experience by IDA and established a mapping relationship between mean opinion scores and IDA.Furthermore,the probability of image damage caused by compression and transmission were analyzed.Based on this analysis,an objective Qo E assessment and prediction method for HD video stream service that evaluated the user experience according to IDA are proposed.The proposed method can achieve assessment and prediction accuracy on three distinct subjective tests. 展开更多
关键词 high-definition video stream quality of experience(QoE) image damage accumulation
在线阅读 下载PDF
Assessments of tear meniscus height, tear film thickness, and corneal epithelial thickness after deep anterior lamellar keratoplasty 被引量:2
17
作者 Wen-jia XIE Ye-sheng XU +1 位作者 Xia ZHANG Yu-feng YAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2018年第3期218-226,共9页
Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was... Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was a retrospective cross-sectional study of 20 patients who had DALK in one eye over a three-month period. LTMH, CTFT, and CCET of the operated eyes and the unoperated fellow eyes were measured using high-definition optical coherence tomography(HD-OCT). Correlations between three OCT assessments and age, time following surgery, graft size, bed size, and the number of residual sutures were analyzed. Results: Compared to patients with keratoconus, patients with other corneal conditions had significantly higher CCET in the fellow eye(P=0.024). For all patients, CCET in the operated eye was significantly negatively correlated with the number of residual sutures(R=-0.579, P=0.008), and was significantly positively correlated with time following surgery(R=0.636, P=0.003). In the fellow eye, a significant positive correlation was found between age and CCET(R=0.551, P=0.012), and a significant negative correlation between age and CTFT(R=-0.491, P=0.028). LTMH was found to be significantly correlated between operated and fellow eyes(R=0.554, P=0.011). There was no significant correlation between LTMH and age, bed/graft size, time following surgery, or residual sutures(all possible correlations, P0.05). Conclusions: Patients with keratoconus tend to have a thinner central corneal epithelium. Corneal epithelium keeps regenerating over time after DALK. DALK did not induce a significant change in tear volume compared with the fellow eye. Postoperative tear function might depend on an individual's general condition, rather than on age, gender, bed/graft size, time following surgery, or residual sutures. 展开更多
关键词 Tear meniscus height Corneal epithelial thickness Tear film Deep anterior lamellar keratoplasty (DALK) high-definition optical coherence tomography (HD-OCT) KERATOCONUS
原文传递
Dimension-Enhanced Ultra-High Performance Liquid Chromatography/Ion Mobility-Quadrupole Time-of-Flight Mass Spectrometry Combined with Intelligent Peak Annotation for the Rapid Characterization of the Multiple Components from Seeds of Descurainia sophia 被引量:1
18
作者 Simiao Wang Xue Li +7 位作者 Boxue Chen Shitong Li Jiali Wang Jing Wang Mingshuo Yang Xiaoyan Xu Hongda Wang Wenzhi Yang 《Phyton-International Journal of Experimental Botany》 SCIE 2022年第3期541-567,共27页
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co... The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS. 展开更多
关键词 Descurainia sophia multicomponent characterization ultra-high performance liquid chromatography ion mobility/quadrupole time-of-flight mass spectrometry high-definition MS^(E) flavonoid
在线阅读 下载PDF
Light and sound- emerging imaging techniques for inflammatory bowel disease 被引量:1
19
作者 Ferdinand Knieling Maximilian J Waldner 《World Journal of Gastroenterology》 SCIE CAS 2016年第25期5642-5654,共13页
Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing fr... Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography. 展开更多
关键词 Ulcerative colitis Crohn’ s disease ENDOSCOPY CHROMOENDOSCOPY Autofluorescence endoscopy Full-view full-spectrum endoscopy Confocal endomicroscopy Multiphoton endoscopy high-definition endoscopy Ultrasound molecular imaging B-mode ultrasound Doppler ultrasound
暂未订购
Precision in detecting colon lesions:A key to effective screening policy but will it improve overall outcomes? 被引量:1
20
作者 Luis Ramon Rabago Maria Delgado Galan 《World Journal of Gastrointestinal Endoscopy》 2024年第3期102-107,共6页
Colonoscopy is the gold standard for the screening and diagnosis of colorectal cancer,resulting in a decrease in the incidence and mortality of colon cancer.However,it has a 21%rate of missed polyps.Several strategies... Colonoscopy is the gold standard for the screening and diagnosis of colorectal cancer,resulting in a decrease in the incidence and mortality of colon cancer.However,it has a 21%rate of missed polyps.Several strategies have been devised to increase polyp detection rates and improve their characterization and delimi-tation.These include chromoendoscopy(CE),the use of other devices such as Endo cuffs,and major advances in endoscopic equipment[high definition,magnification,narrow band imaging,i-scan,flexible spectral imaging color enhancement,texture and color enhancement imaging(TXI),etc.].In the retrospective study by Hiramatsu et al,they compared white-light imaging with CE,TXI,and CE+TXI to determine which of these strategies allows for better definition and delimitation of polyps.They concluded that employing CE associated with TXI stands out as the most effective method to utilize.It remains to be demonstrated whether these results are extrapolatable to other types of virtual CE.Additionally,further investigation is needed in order to ascertain whether this strategy could lead to a reduction in the recurrence of excised lesions and potentially lower the occurrence of interval cancer. 展开更多
关键词 Colonoscopy screening Interval colorectal cancer Post colonoscopy colorectal cancer CHROMOENDOSCOPY Virtual chromoendoscopy high-definition whitelight endoscopy Texture and color enhancement imaging Indigo carmine ADENOMA Sessile serrated lesion
暂未订购
上一页 1 2 下一页 到第
使用帮助 返回顶部