Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switche...Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switched on when voltage through zero and switched off when current through zero.But in the experiment we found that overvoltage will occur in the process of changing tap changer.The paper illustrates the mechanism of overvoltage in theory by analyzing the equivalent circuit and using analytic method of transition process.展开更多
In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the ...In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the threephase four-wire unified power quality conditioner(UPQC),and it also leads to unbalanced three-phase output voltage,even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm(MCA) for the fundamental active component of load currents, and by employing this MCA,balanced three-phase grid currents can be realized under 100% unbalanced loads. The steady-state fluctuation and the transient drop of the DC bus voltage can also be restrained. This paper establishes the mathematical model of the UPQC, analyzes the mechanism of the DC bus voltage fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations;two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified by experiment results.展开更多
基金Harbin science an technology officecontract num ber is 0 0 112 110 98
文摘Analyzes the mechanism of overvoltage when contactless tap changer switch which is applied in distributing transformer converted directly.When the device convert the tap off,it employs the way that the SSR is switched on when voltage through zero and switched off when current through zero.But in the experiment we found that overvoltage will occur in the process of changing tap changer.The paper illustrates the mechanism of overvoltage in theory by analyzing the equivalent circuit and using analytic method of transition process.
基金supported by National Natural Science Foundation of China(No.51477148)
文摘In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the threephase four-wire unified power quality conditioner(UPQC),and it also leads to unbalanced three-phase output voltage,even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm(MCA) for the fundamental active component of load currents, and by employing this MCA,balanced three-phase grid currents can be realized under 100% unbalanced loads. The steady-state fluctuation and the transient drop of the DC bus voltage can also be restrained. This paper establishes the mathematical model of the UPQC, analyzes the mechanism of the DC bus voltage fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations;two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified by experiment results.
文摘通过线控转向(Steer-by-Wire,SBW)系统控制汽车方向盘转角提高某汽车在极限行驶中抗侧翻能力.建立SBW整车模型,基于紧急避让、紧急掉头和蛇行运动等3种危险操纵稳定性工况分析,得出该车易侧翻的结论.提出基于横向载荷转移率(Lateral Load Transfer Ratio,LTR)的车辆动态防侧翻控制算法,通过SIMULINK与Car Sim的联合仿真平台,建立转向优化控制模型.仿真结果表明在典型工况下该车防侧翻性能得到明显改善.