期刊文献+
共找到175篇文章
< 1 2 9 >
每页显示 20 50 100
Determination of Dynamic Load Condition of Aircraft Carrier based on Multivariable Distribution of Flight Parameters
1
作者 JIN Xin LIU Yu ZHANG Jian′gang 《International Journal of Plant Engineering and Management》 2020年第4期223-237,共15页
In order to solve the design problem of dynamic load of a carrier-based aircraft,according to the relevant criteria of national military standards,eight key flight parameters of the dynamic load conditions for the air... In order to solve the design problem of dynamic load of a carrier-based aircraft,according to the relevant criteria of national military standards,eight key flight parameters of the dynamic load conditions for the aircraft carrier were selected.Based on the multivariable distribution data of landing flight parameters obtained from flight test,the distribution form and range limitation of each flight parameter were determined by using the probability distribution of each flight parameter and the spatial relationship among variables.Furthermore,100000 sets of data were constructed to simulate the landing condition of aircraft in the form of random number.After the envelope is screened by multivariable joint probability distribution,the boundary conditions were compared and merged,and finally the dynamic load conditions were obtained.In this paper,a set of dynamic load condition design method based on the aircraft requirements is constructed,which systematically covers all kinds of situations that occur in the process of aircraft landing,and improves the conventional design process of aircraft dynamic load. 展开更多
关键词 load condition flight parameter variables PROBABILITY joint probability
在线阅读 下载PDF
Experimental Measurements of the Sensitivity of Fiber-optic Bragg Grating Sensors with a Soft Polymeric Coating under Mechanical Loading,Thermal and Magnetic under Cryogenic Conditions 被引量:2
2
作者 关明智 王省哲 +2 位作者 辛灿杰 周又和 马力祯 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第1期140-144,共5页
The strain and temperature sensing performance of fiber-optic Bragg gratings (FBGs) with soft polymeric coating, which can be used to sense internal strain in superconducting coils, are evaluated under variable cryo... The strain and temperature sensing performance of fiber-optic Bragg gratings (FBGs) with soft polymeric coating, which can be used to sense internal strain in superconducting coils, are evaluated under variable cryogenic field and magnetic field. The response to a temperature and strain change of coated-soft polymeric FBGs is tested by comparing with those of coated-metal FBGs. The results indicate that the coated-soft polymeric FBGs can freely detect temperature and thermal strain, their At variable magnetic field, the tested results indicate accuracy and repeatability are also discussed in detail. that the cross-coupling effects of FBGs with different matrixes are not negligible to measure electromagnetic strain during fast excitation. The present results are expected to be able to provide basis measurements on the strain of pulsed superconducting magnet/cable (cable- around-conduit conductors, cable-in-conduit conductors), independently or utilized together with other strain measurement methods. 展开更多
关键词 FBG net Experimental Measurements of the Sensitivity of Fiber-optic Bragg Grating Sensors with a Soft Polymeric Coating under Mechanical loading Thermal and Magnetic under Cryogenic conditions
原文传递
Empirical Thermal Investigation of Oil-Immersed Distribution Transformer under Various Loading Conditions
3
作者 Syed Ali Raza Ahsan Ullah +2 位作者 Shuang He Yifeng Wang Jiangtao Li 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第11期829-847,共19页
The distribution transformer is the mainstay of the power system.Its internal temperature study is desirable for its safe operation in the power system.The purpose of the present study is to determine direct comprehen... The distribution transformer is the mainstay of the power system.Its internal temperature study is desirable for its safe operation in the power system.The purpose of the present study is to determine direct comprehensive thermal distribution in the distribution transformers for different loading conditions.To achieve this goal,the temperature distribution in the oil,core,and windings are studied at each loading.An experimental study is performed with a 10/0.38 kV,10 kVA oil–immersed transformer equipped with forty–two PT100 sensors(PTs)for temperature measurement installed inside during its manufacturing process.All possible locations for the hottest spot temperature(HST)are considered that made by finite element analysis(FEA)simulation and losses calculations.A resistive load is made to achieve 80%to 120%loading of the test transformer for this experiment.Working temperature is measured in each part of the transformer at all provided loading conditions.It is observed that temperature varies with loading throughout the transformer,and a detailed map of temperature is obtained in the whole test transformer.From these results,the HST stays in the critical section of the primary winding at all loading conditions.This work is helpful to understand the complete internal temperature layout and the location of the HST in distribution transformers. 展开更多
关键词 Distribution transformer direct temperature measurement sensor location loading conditions hottest spot temperature thermal distribution
在线阅读 下载PDF
Research of Interaction Force Coefficients Based on Model Test in Loading Condition
4
作者 刘小健 黄国樑 邓德衡 《Journal of Shanghai Jiaotong university(Science)》 EI 2010年第2期168-171,共4页
It is very difficult,for the component-type ship mathematical model,to estimate the interaction force coefficients among the hull,propeller and rudder. Some coefficients such as wake fraction and flow straightening co... It is very difficult,for the component-type ship mathematical model,to estimate the interaction force coefficients among the hull,propeller and rudder. Some coefficients such as wake fraction and flow straightening coefficient were studied from the model tests in diffierent loading conditions and the normal force of rudder was tested in captive model tests to obtain the coefficients. From these results of the tests,the flow straightening coefficients increase with the increase of trims or drafts. Similarly,wake fraction coefficients are larger for the large drafts,however,become small as the trims increase. The resistance is obviously different in fully loaded condition with the trims by stern,however ,the difference is not evident when the draft decreases and the bulbous bow is above the water surface. 展开更多
关键词 interaction force coefficient rudder normal force loading condition model test
原文传递
Computational Fracture Analysis of an AFM-Specimen under Mixed Mode Loading Conditions
5
作者 朱莉 李庆芬 F.G.Buchholz 《Journal of Marine Science and Application》 2011年第1期105-112,共8页
Fracture processes in ship-building structures are in many cases of a 3-D character. A finite element (FE) model of an all fracture mode (AFM) specimen was built for the study of 3-D mixed mode crack fracture beha... Fracture processes in ship-building structures are in many cases of a 3-D character. A finite element (FE) model of an all fracture mode (AFM) specimen was built for the study of 3-D mixed mode crack fracture behavior including modes Ⅰ,Ⅱ, and Ⅲ. The stress intensity factors (SIFs) were calculated by the modified virtual crack closure integral (MVCCI) method, and the crack initiation angle assessment was based on a recently developed 3-D fracture criterion--the Richard criterion. It was shown that the FE model of the AFM-specimen is applicable for investigations under general mixed mode loading conditions, and the computational results of crack initiation angles are in agreement with some available experimental findings. Thus, the applicability of the FE model of the AFM-specimen for mixed mode loading conditions and the validity of the Richard criterion can be demonstrated. 展开更多
关键词 3-D crack fracture behavior stress intensity factors (SIFs) all fracture mode (AFM) specimen crack initiation angle mixed mode loading conditions
在线阅读 下载PDF
Molecular Dynamics Simulation for Grain Boundary Deformation under Tensile Loading Condition
6
《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2001年第1期145-146,共2页
关键词 SIMULATION Molecular Dynamics Simulation for Grain Boundary Deformation under Tensile loading condition
在线阅读 下载PDF
Degradation of joint surface morphology, shear behavior and closure characteristics during cyclic loading 被引量:6
7
作者 FAN Wen-chen CAO Ping LONG Long 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第3期653-661,共9页
In order to investigate the failure mechanism of rock joint,a series of laboratory tests including cyclic direct shear tests under constant normal load(CNL)conditions were conducted.Morphology parameters of the rock j... In order to investigate the failure mechanism of rock joint,a series of laboratory tests including cyclic direct shear tests under constant normal load(CNL)conditions were conducted.Morphology parameters of the rock joint surface were precisely calculated by means of a three-dimensional laser scanning machine.All test results were analyzed to investigate the shear behavior and normal displacement behavior of rock joints under CNL conditions.Degradation of rock joint surface during cyclic shear tests was also analyzed.The comparison results of the height parameters and the hybrid parameters of the joint surface during cyclic tests show that the degradation of the surface mostly happens in the first shear and the constant normal loads imposed on the joints have significant promotion effects on the morphology degradation.During cyclic shear tests,joints surfaces evolve from rough state to smooth state but keep an overall undulation.Dilatancy of rock joints degrades with the degradation of joint surface and the increase of normal loads.The closure deformation of joint is larger than that of the intact rock,and the normal stiffness increases with the increase of shearing times. 展开更多
关键词 rock joint constant normal load condition surface morphology degradation shear behavior joint closure characteristic
在线阅读 下载PDF
Effect of bolt inclination angle on shear behavior ofbolted joints under CNL and CNS conditions 被引量:19
8
作者 CUI Guo-jian ZHANG Chuan-qing +3 位作者 CHEN Jian-lin YANG Fan-jie ZHOU Hui LU Jing-jing 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第3期937-950,共14页
Rock bolts are widely used in rock engineering projects to improve the shear capacity of the jointed rock mass.The bolt inclination angle with respect to the shear plane has a remarkable influence on the bolting perfo... Rock bolts are widely used in rock engineering projects to improve the shear capacity of the jointed rock mass.The bolt inclination angle with respect to the shear plane has a remarkable influence on the bolting performance.In this study,a new artificial molding method based on 3D scanning and printing technology was first proposed to prepare bolted joints with an inclined bolt.Then,the effects of the bolt inclination angle and boundary conditions on the shear behavior and failure characteristic of bolted joints were addressed by conducting direct shear tests under both CNL and CNS conditions.Results indicated that rock bolt could significantly improve the shear behavior of rock joints,especially in the post-yield deformation region.With the increase of bolt inclination angle,both the maximum shear stress and the maximum friction coefficient increased first and then decreased,while the maximum normal displacement decreased monotonously.Compared with CNL conditions,the maximum shear stress was larger,whereas the maximum normal displacement and friction coefficient were smaller under the CNS conditions.Furthermore,more asperity damage was observed under the CNS conditions due to the increased normal stress on the shear plane. 展开更多
关键词 bolted joints bolt inclination angle constant normal load(CNL)boundary conditions constant normal stiffness(CNS)boundary conditions direct shear test asperity damage
在线阅读 下载PDF
Optimal Scheduling of Air Conditioners for Energy Efficiency
9
作者 K.Venkatesan Uppu Ramachandraiah 《Journal of Electronic Science and Technology》 CAS CSCD 2018年第2期110-122,共13页
Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy... Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively. 展开更多
关键词 Building fabric cooling load energy balanced air conditioning energy efficiency scheduling of air conditioners
在线阅读 下载PDF
基于动态负荷的房间空调器能效测试方法验证
10
作者 夏玉娟 杨双 +2 位作者 王现林 李亚飞 亓新 《暖通空调》 2025年第10期26-32,共7页
基于实验室特定负荷稳态工况的房间空调器能效测试方法不能真实反映产品实际使用状况及控制技术水平,而国内外提出的动态测量方法在运行控制参数的设置与结果的重复性方面仍缺乏广泛验证。本文利用2台规格1.5HP的变频空调器在焓差试验... 基于实验室特定负荷稳态工况的房间空调器能效测试方法不能真实反映产品实际使用状况及控制技术水平,而国内外提出的动态测量方法在运行控制参数的设置与结果的重复性方面仍缺乏广泛验证。本文利用2台规格1.5HP的变频空调器在焓差试验室内对2种基于不同虚拟建筑负荷模型、测试工况和收敛性判定条件的能效动态测试方法进行了试验验证。结果表明:采用基于负荷投入的动态测量方法能够更好地反映空调器实际运行能效水平,其中1#样机采用方案1测得的全年能效偏差约为1.5%,制冷和制热季节动态能效偏差分别为5.0%和2.0%,2#样机采用方案2进行制冷运行的单工况能效重复性为3.8%~11.8%;相同样机采用不同方法在室外温度35℃下进行动态制冷运行,其制冷量、功率、虚拟负荷、制冷性能系数等关键参数的结果偏差较为明显。为确保动态测试方法的有效性和可操作性,需进一步完善试验方法和测试装置配套,结合实际使用情况优化测试条件,从而有效提升测试方法的科学性和测量结果的重复性。 展开更多
关键词 房间空调器 动态负荷 虚拟负荷模型 测试工况 能效
在线阅读 下载PDF
房间空调器动态运行能效测试方法研究 被引量:2
11
作者 李亚飞 连彩云 +4 位作者 王现林 成建宏 陈志伟 梁博 夏光辉 《制冷与空调》 2025年第3期87-94,共8页
为了测试房间空调器实际动态运行时的能效,文章提出了一种基于虚拟负荷房间空调器动态运行能效测试方法,并通过改造空气焓差试验室实现了空调器的动态运行能效测量。动态能效测试结果表明:1)实现了室内干湿球温度按照空调近实际运行状... 为了测试房间空调器实际动态运行时的能效,文章提出了一种基于虚拟负荷房间空调器动态运行能效测试方法,并通过改造空气焓差试验室实现了空调器的动态运行能效测量。动态能效测试结果表明:1)实现了室内干湿球温度按照空调近实际运行状态进行动态变化;2)制冷、制热工况的室内干湿球温度跟随性良好,设定值与实际值的平均误差在0.5℃范围之内;3)在动态测试过程中,空调能力与建筑热负荷动态协调,使得空调按照自有控制逻辑动态运行,提出的方法能够获得制冷、制热工况的空调动态运行能效。 展开更多
关键词 空调器 动态能效 负荷模拟 动态测试
在线阅读 下载PDF
面向源荷储协调优化的非侵入式空调负荷精准感知系统
12
作者 顾玮 薛泓林 +5 位作者 段敬 王迪 张建亮 霍美如 高英豪 李想 《现代电力》 北大核心 2025年第6期1153-1161,共9页
推进源荷储互动并参与电力市场有利于各类资源的协调开发和配置。但需求侧可调资源的定量分析方式未考虑弹性负荷的随机性,由于空调负荷数量多且可控性强,研究面向源荷储协调优化的非侵入式空调负荷精准感知系统。首先针对全面感知需求... 推进源荷储互动并参与电力市场有利于各类资源的协调开发和配置。但需求侧可调资源的定量分析方式未考虑弹性负荷的随机性,由于空调负荷数量多且可控性强,研究面向源荷储协调优化的非侵入式空调负荷精准感知系统。首先针对全面感知需求侧负荷导致资源浪费的问题,基于小波变换分析空调负荷的暂态特性,实现类空调负荷的事件检测;然后基于特征工程对空调负荷稳态特性的一致性以及与其他负荷的差异性进行结构化表征,与随机森林进行结合构建空调负荷专用辨识模型。最后通过空调负荷调节潜力评估模型实时分析区域内空调的可调容量。利用公开数据集以及实际采集数据进行仿真分析,感知结果验证了系统的准确性和有效性。 展开更多
关键词 非侵入式负荷监测 空调 小波变换 随机森林 容量评估
原文传递
基于新型双闭环控制的统一电能质量调节器
13
作者 习超 余梦天 +3 位作者 聂健 冯琦 赵军波 马辉 《电力电容器与无功补偿》 2025年第3期91-98,共8页
针对统一电能质量调节器中传统PI控制器存在跟踪能力较差和控制精度较低的问题,本文提出一种并联侧有源电力滤波器(APF)为双闭环非线性复合控制方法的统一电能质量调节器(UPQC)。新型UPQC并联侧APF采用了一种新型双闭环非线性复合控制方... 针对统一电能质量调节器中传统PI控制器存在跟踪能力较差和控制精度较低的问题,本文提出一种并联侧有源电力滤波器(APF)为双闭环非线性复合控制方法的统一电能质量调节器(UPQC)。新型UPQC并联侧APF采用了一种新型双闭环非线性复合控制方法,电压外环利用滑模PI复合非线性控制算法,电流内环则使用重复PI非线性控制算法。通过实验装置对UPQC在静态干扰(如电网电压谐波/不平衡和负载电流谐波)及动态干扰(如电压骤降/骤升和负载变化)下的性能测试,结果表明所提UPQC能够在负载突变和参考电压跳变时提高直流侧电压的响应速度和稳态精度,验证了理论的正确性。 展开更多
关键词 统一电能质量调节器 负载突变 参考电压跳变 双闭环非线性 滑模控制
在线阅读 下载PDF
Quantitative method and influencing factors analysis of demand response performance of air conditioning load with rebound effect
14
作者 Ran Wang Xiaoyue Xin +3 位作者 Jiatao Liu Shilei Lu Yongjun Sun Wenduan Zhao 《Building Simulation》 2025年第2期295-320,共26页
Under the emerging trend of the new power systems,enhancing the energy flexibility of air conditioning loads to promote electricity demand response is crucial for regulating the real-time balance.As a typical temperat... Under the emerging trend of the new power systems,enhancing the energy flexibility of air conditioning loads to promote electricity demand response is crucial for regulating the real-time balance.As a typical temperature-controlled loads,air conditioning loads can generate rebound effect when participating in demand response,resulting in sudden load increases and posing risks to grid security.However,the existing research mainly focuses on the energy flexibility,which leads to an imperfect demand response mechanism and thus affects the optimal scheduling strategy.Therefore,the study proposes a comprehensive quantification method in view of rebound effect for the demand response performance of air conditioning loads,by using probability distribution,Latin hypercube sampling,Monte Carlo simulation,and scenario analysis methods.The demand response event was divided into response phase and recovery phase,and by considering energy flexibility during the response phase and rebound effect during the recovery phase,three dimensionless evaluation indexes for comprehensive demand response performance were constructed.Using this quantification method,the impact patterns of three types of random variables were compared,including meteorological,design variables,and control variables.Additionally,considering the differences in building types(office and hotel buildings)and building capacities(small,medium,and large),the effectiveness of air conditioning load participation in demand response measures in different building application scenarios was explored.The results show that the influence of the design variables on the response performance is less than that of the control variables,but significant,reaching 45%compared to the control variables.Moreover,the influence varies with building type,capacity and climate zone,and building demand response design has more potential in the following scenarios:the cold climate,the hot summer and cold winter climate,the medium building and the hotel building. 展开更多
关键词 demand response air conditioning load energy flexibility rebound effect parameter analysis scenario analysis
原文传递
多联机空调柔性负荷控制器的功率模型标定和控制算法响应特性研究
15
作者 付哲 刘人玮 +2 位作者 蒋帅 刘瑞 张雅欣 《暖通空调》 2025年第10期74-89,共16页
针对目前缺乏具体的多联机空调柔性负荷响应控制算法及控制器硬件设备的问题,本文通过设备测点与功能组网设计、实验测试、BP神经网络功率模型构建、等效热参数(ETP)模型仿真实验、柔性负荷响应控制算法设计,实现了完整的功能构建;针对... 针对目前缺乏具体的多联机空调柔性负荷响应控制算法及控制器硬件设备的问题,本文通过设备测点与功能组网设计、实验测试、BP神经网络功率模型构建、等效热参数(ETP)模型仿真实验、柔性负荷响应控制算法设计,实现了完整的功能构建;针对空调柔性负荷响应过程中显著的功率反弹现象,设计了连续小幅度调节设定温度和部分关闭室内机的控制策略,并完成了实验验证。结果表明:对于17.5 kW的空调,制冷模式下设定温度每提高1℃,实际功率可下降约2.4~3.4 kW,舒适度范围内柔性可调负荷约占额定功率的40%~60%;连续小幅度调节设定温度约1 h内可以构建新的平衡,而部分关闭室内机可实现35%~55%的负荷响应。 展开更多
关键词 多联机空调 柔性负荷 响应特性 设定温度调节 功率反弹 控制策略
在线阅读 下载PDF
国外空调器能效标准中气候分区及能源消耗效率计算方法分析 被引量:1
16
作者 李寅 吴晓丽 《制冷与空调》 2025年第5期41-47,共7页
对ISO、欧盟、美国、澳大利亚、日本等空调器能效标准中气候分区及能源消耗效率计算方法进行比较分析,主要涉及室外温度分布及发生时间、实测点、负荷线等方面。本研究可为我国相关标准的制修订提供参考。
关键词 空调器 能源消耗效率 气候分区 制冷季节 制热季节 负荷线
在线阅读 下载PDF
基于PSO-ELM的可植入UPQC的“源-网-荷-储”系统最优控制策略
17
作者 高波 刘川 +2 位作者 韩建 李泽文 韦宝泉 《电力系统保护与控制》 北大核心 2025年第2期62-72,共11页
针对传统“源-网-荷-储”(source network load storage,SNLS)系统的可再生能源渗透率低及电能质量差等问题,提出了一种可植入统一电能质量调节器(unified power quality conditioner,UPQC)的SNLS系统最优控制方案。该方案通过基于粒子... 针对传统“源-网-荷-储”(source network load storage,SNLS)系统的可再生能源渗透率低及电能质量差等问题,提出了一种可植入统一电能质量调节器(unified power quality conditioner,UPQC)的SNLS系统最优控制方案。该方案通过基于粒子群优化(particle swarm optimization,PSO)的极限学习机(extreme learning machine,ELM)方法实现。在多目标优化运行方案中:第一个优化目标为最大化光伏阵列发电量;第二、三个优化目标分别为最小化负荷电压偏差和最大化网侧功率因数;第四个优化目标则为最大化变换器的利用率。由于多目标优化问题不易实时求解,提出了一种基于优化目标优先权顺序的分层优化思想,将多目标优化问题简化为若干个单目标优化问题。然后,通过将求解的所有最优解集训练为PSO-ELM代理模型,以实现所提策略的快速精确执行。最后,通过仿真验证了所提方法的有效性。算例表明所提策略可提升可再生能源的消纳率与系统变换器的利用率,并优化电能质量。 展开更多
关键词 统一电能质量调节器 “源-网-荷-储”系统 光伏 PSO-ELM
在线阅读 下载PDF
计及用户不确定性的温控负荷集群可调节潜力概率评估与互动
18
作者 赵龙 孙毅 +2 位作者 王宪 刘晓明 孙东磊 《现代电力》 北大核心 2025年第5期978-986,I0006-I0008,共12页
准确评估空调温控负荷集群的可调潜力并加以利用,可实现光伏等新能源波动平抑,维持电网安全稳定运行。针对目前研究存在的模型驱动方法的模型参数泛化、数据驱动方法的物理概念弱化和鲁棒性较差等问题,提出一种计及不确定性的温控负荷... 准确评估空调温控负荷集群的可调潜力并加以利用,可实现光伏等新能源波动平抑,维持电网安全稳定运行。针对目前研究存在的模型驱动方法的模型参数泛化、数据驱动方法的物理概念弱化和鲁棒性较差等问题,提出一种计及不确定性的温控负荷集群可调节潜力概率评估方法。首先,开展基于模型与数据混合驱动的温控负荷集群建模,实现日内温控集群实际负荷曲线的跟踪。然后,在考虑实际空调所处建筑物参数不可测和用户用电行为不确定两方面,基于KL散度验证所提方法的鲁棒性。最后,基于混合驱动模型建立空调负荷集群响应能力的概率评估与互动机制,以山东某地区10 kV馈线为实际算例,结果表明所提方法能够有效抑制潮流返送现象,实现分布式光伏的完全就地消纳。 展开更多
关键词 潜力评估 温控负荷集群 混合驱动 概率评估 变频空调
原文传递
空调负荷运行特性研究及建模 被引量:33
19
作者 郑竞宏 朱守真 +1 位作者 王光 王小宇 《中国电机工程学报》 EI CSCD 北大核心 2009年第10期67-73,共7页
空调负荷是近年来增长较快的一类负荷,其特性对电网的电压稳定性影响很大。该文在电力系统动态模拟实验室进行的空调特性试验的基础上,对空调负荷的静态特性、电压动态特性、启动过程和堵转过程进行了详细分析,建立了空调负荷的这4种重... 空调负荷是近年来增长较快的一类负荷,其特性对电网的电压稳定性影响很大。该文在电力系统动态模拟实验室进行的空调特性试验的基础上,对空调负荷的静态特性、电压动态特性、启动过程和堵转过程进行了详细分析,建立了空调负荷的这4种重要运行状态的负荷模型,可作为空调负荷建模研究的重要参考。 展开更多
关键词 空调负荷 空调负荷运行特性 空调负荷建模 空调启动特性 空调堵转特性
原文传递
单台空调负荷动态特性分析与建模 被引量:18
20
作者 徐群 刘刚 +5 位作者 李育燕 黄丽 方朝雄 陈峰 赵红嘎 鞠平 《高电压技术》 EI CAS CSCD 北大核心 2006年第11期127-130,共4页
空调负荷的比例和影响日益增大,为分析其停机特性、启动特性以及电压扰动特性,选用一台辅助电热型分体落地式房间空调器进行实测。结果表明:0.6倍额定电压为空调的停机电压;空调启动时电流冲击倍数可达5~10倍,在0.3~0.5S之内... 空调负荷的比例和影响日益增大,为分析其停机特性、启动特性以及电压扰动特性,选用一台辅助电热型分体落地式房间空调器进行实测。结果表明:0.6倍额定电压为空调的停机电压;空调启动时电流冲击倍数可达5~10倍,在0.3~0.5S之内平息;电压扰动过程中,当电压大于停机电压时有功功率变化小而无功功率变化大,当电压降到停机电压后空调停机且功率为0,当电压恢复到187V后再经过3~5s空调可重新启动,因此空调的电压扰动特性是分时段的。在此基础上对单台空调进行建模:电压高于停机电压时采用Karlsson-Hill模型,低于停机电压时空调停机,电压恢复时采用启动模型,可用一指数函数近似拟合功率振荡下降的包络线,结果表明该负荷模型可以很好地拟合空调的特性。 展开更多
关键词 空调负荷 单台空调 负荷建模 负荷特性 停机
在线阅读 下载PDF
上一页 1 2 9 下一页 到第