期刊文献+
共找到507篇文章
< 1 2 26 >
每页显示 20 50 100
Structured Light 3D Vision Based on Laser Scanning Space-encoding and Its Synchro Control 被引量:1
1
作者 于晓洋 强锡富 +1 位作者 张健 吴丽莹 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1997年第2期20-24,共5页
This paper presents the principle and mathematic model for the 3D depth map method based on space encoding images performed by modulating scanning structuredlight according to time sequences,and the synchro control ... This paper presents the principle and mathematic model for the 3D depth map method based on space encoding images performed by modulating scanning structuredlight according to time sequences,and the synchro control among the camera,laser diode modulation and scanning polyhedron. 展开更多
关键词 D VISION STRUCTURED light space encoding LASER scanning SYNCHRO control
在线阅读 下载PDF
Image charge effect on the light emission of rutile TiO2(110) induced by a scanning tunneling microscope
2
作者 Chaoyu Guo Xiangzhi Meng +1 位作者 Qin Wang Ying Jiang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期158-162,共5页
The plasmon-enhanced light emission of rutile TiO2(110) surface has been investigated by a low-temperature scanning tunneling microscope (STM). We found that the photon emission arises from the inelastic electron ... The plasmon-enhanced light emission of rutile TiO2(110) surface has been investigated by a low-temperature scanning tunneling microscope (STM). We found that the photon emission arises from the inelastic electron tunneling between the STM tip and the conduction band or defect states of TiO2(110). In contrast to the Au(111) surface, the maximum photon energy as a function of the bias voltage clearly deviates from the linear scaling behavior, suggesting the non-negligible effect of the STM tip on the band structure of TiO2. By performing differential conductance (dl/dV) measurements, it was revealed that such a deviation is not related to the tip-induced band bending, but is attributed to the image charge effect of the metal tip, which significantly shifts the band edges of the TiO2(110) towards the Femi level (EF) during the tunneling process. This work not only sheds new lights onto the understanding of plasmon-enhanced light emission of semiconductor surfaces, but also opens up a new avenue for engineering the plasmon-mediated interfacial charge transfer in molecular and semiconducting materials. 展开更多
关键词 scanning tunneling microscopy light emission TIO2 PLASMON
原文传递
Mapping tree canopies in urban environments using airborne laser scanning (ALS):a Vancouver case study 被引量:4
3
作者 Giona Matasci Nicholas C.Coops +1 位作者 David A.R.Williams Nick Page 《Forest Ecosystems》 SCIE CSCD 2018年第4期429-437,共9页
Background: The distribution of forest vegetation within urban environments is critically important as it influences urban environmental conditions and the energy exchange through the absorption of solar radiation and... Background: The distribution of forest vegetation within urban environments is critically important as it influences urban environmental conditions and the energy exchange through the absorption of solar radiation and modulation of evapotranspiration. It also plays an important role filtering urban water systems and reducing storm water runoff.Methods: We investigate the capacity of ALS data to individually detect, map and characterize large(taller than15 m) trees within the City of Vancouver. Large trees are critical for the function and character of Vancouver’s urban forest. We used an object-based approach for individual tree detection and segmentation to determine tree locations(position of the stem), to delineate the shape of the crowns and to categorize the latter either as coniferous or deciduous.Results: Results indicate a detection rate of 76.6% for trees > 15 m with a positioning error of 2.11 m(stem location). Extracted tree heights possessed a RMSE of 2.60 m and a bias of-1.87 m, whereas crown diameter was derived with a RMSE of 3.85 m and a bias of-2.06 m. Missed trees are principally a result of undetected treetops occurring in dense, overlapping canopies with more accurate detection and delineation of trees in open areas.Conclusion: By identifying key structural trees across Vancouver’s urban forests, we can better understand their role in providing ecosystem goods and services for city residents. 展开更多
关键词 Urban forest Large trees light detection and ranging Airborne laser scanning
在线阅读 下载PDF
电子鼻咽喉镜中I-scan各模式与白光模式的应用比较 被引量:1
4
作者 倪凌达 唐旭兰 +2 位作者 孟丽丽 周慧群 苏开明 《山东大学耳鼻喉眼学报》 2025年第3期19-25,共7页
目的探讨日本宾得(Pentax)所产电子鼻咽喉镜的I-scan功能中各项模式与白光模式在鼻咽喉科疾病图像显示中的适用性。方法回顾性分析96例鼻咽喉科疾病患者的图像资料,对其在6种I-scan模式与白光(WL)模式下拍摄的图片进行互相比较。结果I-s... 目的探讨日本宾得(Pentax)所产电子鼻咽喉镜的I-scan功能中各项模式与白光模式在鼻咽喉科疾病图像显示中的适用性。方法回顾性分析96例鼻咽喉科疾病患者的图像资料,对其在6种I-scan模式与白光(WL)模式下拍摄的图片进行互相比较。结果I-scan功能中各模式与白光模式的摄片效果有显著差异,p、b、e、g、c模式下的图像在细节显示、血管突出方面优于白光模式,以g、c模式优点更为显著,v模式则表现差于白光模式。结论在鼻咽喉科疾病的图片资料采摄中,I-scan各模式有效补充白光模式的短板,各模式互补利用,临床诊断效率提高,值得推广应用。 展开更多
关键词 电子鼻咽喉镜 I-scan功能 窄带成像技术 黏膜微腺管 白光图像
原文传递
New LED light source system with uniform illumination for line-scan CCD imaging systems
5
作者 张莲莲 黄庆梅 +3 位作者 李心怡 胡维贵 刘南渤 陆爱民 《Journal of Beijing Institute of Technology》 EI CAS 2016年第4期571-574,共4页
A system with uniform light reflection in the inner surface within a horizontal 2/3 cylindrical structure for line-scan CCD of the print testing was designed. The design was based on diffuse reflection uniformity of t... A system with uniform light reflection in the inner surface within a horizontal 2/3 cylindrical structure for line-scan CCD of the print testing was designed. The design was based on diffuse reflection uniformity of the integrating sphere and requirement of the strip uniform illumination region. This system was called dome light. White light LED array light sources were used for uniform illumi- nation. The LEDs were filtrated to composite array light source based on coefficient of variation of a single LED. The standard white board and SG color checkers were used in the line-scan CCD imaging experiments under the dome light and ordinary illumination light source. The average color difference (AE) of SG color checkers in CIELAB space was 2. 091 under the dome light and 2. 286 under ordinary illumination light source respectively. Experimental results indicate that the dome light can satisfy illumination uniformity and color rendering consistency for line-scan CCD and provide a standard light source for uniform calibration of different cameras. 展开更多
关键词 line-scan CCD uniform illumination white light LED coefficient of variation arraylight source color difference
在线阅读 下载PDF
The Calibration Method of Line Structured Light Sensor for Integrated Position and Pose Detection of Highway Guardrail Inspection Robots
6
作者 WANG Rui BAI Jiadi +4 位作者 XUE Yingqi PENG Lu FENG Xiaofan DING Ailing WEI Baojiang 《Wuhan University Journal of Natural Sciences》 2025年第4期367-378,共12页
The accuracy of center height detection for corrugated beam guardrails is significantly affected by robot posture in the mobile highway guardrail detection systems based on structured light vision.To address the probl... The accuracy of center height detection for corrugated beam guardrails is significantly affected by robot posture in the mobile highway guardrail detection systems based on structured light vision.To address the problem,this paper proposes an integrated calibration method for structured light vision sensors.In the proposed system,the sensor is mounted on a crawler-type mobile robot,which scans and measures the center height of guardrails while in motion.However,due to external disturbances such as uneven road surfaces and vehicle vibrations,the posture of the robot may deviate,causing displacement of the sensor platform and resulting in spatial 3D measurement errors.To overcome this issue,the system integrates inertial measurement unit(IMU)data into the sensor calibration process,enabling realtime correction of posture deviations through sensor fusion.This approach achieves a unified calibration of the structured light vision system,effectively compensates for posture-induced errors,and enhances detection accuracy.A prototype was developed and tested in both laboratory and real highway environments.Experimental results demonstrate that the proposed method enables accurate center height detection of guardrails under complex road conditions,significantly reduces posture-related measurement errors,and greatly improves the efficiency and reliability of traditional detection methods. 展开更多
关键词 highway corrugated guardrail structured light visual scanning structured light sensor calibration guardrail detection robot robot motion posture parameters
原文传递
利用激光扫描共聚焦显微镜冷冻观测技术表征页岩亚微米孔隙中的含油性——以松辽盆地古龙凹陷青山口组页岩油为例
7
作者 邵红梅 李照阳 +3 位作者 王继平 张刘平 高波 黄晓天 《大庆石油地质与开发》 北大核心 2026年第1期9-18,共10页
轻质油是页岩油勘探开发的重要目标,但由于其易挥发,导致难以观测。为解决这一问题,研制了激光扫描共聚焦显微镜的专用冷台,并确定了观测温度。在此基础上,通过反射光和长、短波荧光多重扫描,实现了冷冻页岩样品中亚微米孔隙含油性的有... 轻质油是页岩油勘探开发的重要目标,但由于其易挥发,导致难以观测。为解决这一问题,研制了激光扫描共聚焦显微镜的专用冷台,并确定了观测温度。在此基础上,通过反射光和长、短波荧光多重扫描,实现了冷冻页岩样品中亚微米孔隙含油性的有效观测。结果表明:松辽盆地古龙凹陷A井青山口组页岩油多呈不规则形状、斑块状和星点状;亚微米孔隙中轻质油的面积含量明显高于重质组分(包括重质油、胶质沥青质和生烃母质),轻/重比(面积比)高达2.5;在观测井段,轻质油主要富集于泥质粉砂岩和纹层状页岩,纵向上呈现上轻下重的分布特征;根据轻质油和轻/重比的分布情况,认为Q_(4-5)和Q_(7)油层组值得关注;轻质油的富集不仅受生烃母质和成熟度的控制,页岩层系内的储集空间和短距离运移也是重要因素。系统观测与研究富含轻质油页岩的分布规律,可为优化勘探开发目标,优选水平井压裂井段和进一步提高页岩油产量提供重要依据。 展开更多
关键词 页岩油 轻质油 激光扫描共聚焦显微镜 冷台 含油性 岩性 松辽盆地
在线阅读 下载PDF
GE Light Speed多层螺旋CT扫描断续故障分析及检修
8
作者 甘泉 赵天 +3 位作者 刘文 殷瑞根 王冬青 彭卫斌 《临床放射学杂志》 CSCD 北大核心 2009年第1期100-100,共1页
关键词 多层螺旋CT扫描 故障分析 light GE 检修 BUFFER scan 故障现象
原文传递
岩石的多技术联合分析在案件侦破中的应用
9
作者 王萍 罗善霞 +6 位作者 梅宏成 郭洪玲 杨瑞琴 朱军 胡灿 邓显贺 权养科 《中国司法鉴定》 2026年第1期48-54,共7页
目的 岩石等地质样本在案件侦破中的应用逐年增加,多技术联合分析对确定样品关联性具有重要意义。方法 采用X射线衍射仪结合Rietveld全谱拟合定量、偏振光显微镜、X射线荧光光谱仪和扫描电子显微镜-X射线能谱仪等技术,对一起刑事案件中... 目的 岩石等地质样本在案件侦破中的应用逐年增加,多技术联合分析对确定样品关联性具有重要意义。方法 采用X射线衍射仪结合Rietveld全谱拟合定量、偏振光显微镜、X射线荧光光谱仪和扫描电子显微镜-X射线能谱仪等技术,对一起刑事案件中现场和涉案人员家中提取的岩石样品进行矿物组成与含量、元素组成与含量的分析。结果 两地样品中主要矿物组成均为方解石(多受白云石化作用)以及少量石英、伊利石;主要元素均检出Mg、Al、Si、P、S、K、Ca、Fe和Sr;以两份样品的矿物、氧化物和元素半定量数据作为指标数值,采用夹角余弦法和斯皮尔曼等级相关系数法计算样品间相关性系数分别为0.999和0.965。结论 综上,不排除现场样品与涉案人员家中样品属于相同来源的可能。该方法为岩石、矿石、固体废物等检验和鉴别以及公安侦查提供技术支持。 展开更多
关键词 矿物组成 元素组成 X射线衍射仪 偏振光显微镜 X荧光光谱仪 扫描电子显微镜-X射线能谱仪
在线阅读 下载PDF
A Rapid Calibration Technique for Scanning Line-Structured Laser Sensor
10
作者 Li Tao, Changku Sun, ZhiqinXu, Wei Wei State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期839-840,共2页
A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters ... A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters is achieved simultaneously. 展开更多
关键词 for in of on BE AS LINE A Rapid Calibration Technique for scanning line-structured Laser Sensor
原文传递
Effects of light curing modes and ethanol-wet bonding on dentin bonding properties
11
作者 Mu-zi LI Jin-rui WANG +5 位作者 Hong LIU Xia WANG Kang GAN Xiu-ju LIU De-li NIU Xiao-qing SONG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2016年第9期703-711,共9页
Objective: This study explored the effects of different light curing modes and ethanol-wet bonding on dentin bonding strength and durability. Methods: A total of 54 molars were randomly divided into three groups: S... Objective: This study explored the effects of different light curing modes and ethanol-wet bonding on dentin bonding strength and durability. Methods: A total of 54 molars were randomly divided into three groups: Single Bond 2, Gluma Comfort Bond, and N-Bond. Based on the three light-curing modes and presence or absence of eth- anol pretreatment, the samples were assigned to six subgroups: high-light mode, ethanol pretreatment+high-light mode, soft-start mode, ethanol pretreatment+soft-start mode, standard mode, and ethanol pretreatment+standard mode. All samples were bonded with resin based on the experimental groups. After 24 h and 6 months of water storage, a universal testing machine was used to measure microtensile bond strength. Scanning electron microscopy (SEM) was applied to observe mixed layer morphology. Results: The 24-h and 6-month microtensile bond strengths of the ethanol pretreatment groups were significantly higher than those of the non-ethanol pretreatment groups at the same light modes (P〈0.05). With or without ethanol pretreatment, the microtensile bond strengths of the high-light modes were significantly lower than those of the soft-start modes and standard modes (P〈0.05). The microtensile bond strengths of samples from the 6-month water storage group significantly decreased compared with those of samples from the 24-h water storage group (P〈0.05). The soft-start groups and standard groups formed better mixed layers than the high-light mode groups, whereas the ethanol pretreatment groups formed more uniform mixed layers than those without ethanol pretreatment. Conclusions: Ethanol-wet bonding technique, soft-start, and standard modes could improve dentin bonding properties. 展开更多
关键词 light curing mode Soft-start Ethanol-wet bonding scanning electron microscopy (SEM) Bondingstrength
原文传递
The Successful Treatment of Dysarthria Using Strannik Light Therapy (Biofeedback): A Case Study
12
作者 Graham Wilfred Ewing 《Case Reports in Clinical Medicine》 2015年第7期266-269,共4页
This article reports a case of dysarthria which was successfully treated by Strannik Light Therapy (SLT). It briefly discusses the known etiology for the condition and illustrates that dysarthria must be a problem of ... This article reports a case of dysarthria which was successfully treated by Strannik Light Therapy (SLT). It briefly discusses the known etiology for the condition and illustrates that dysarthria must be a problem of autonomic dysfunction in which pathological changes can influence the structure and/or subsequent function of the dynamic interplay between the brain and the organs involving the autonomic nervous system and physiological systems. The author reports a particular case in which a patient undertaking SLT fully recovered the ability to speak within 6 days. 展开更多
关键词 DYSARTHRIA DYSAUTONOMIA AUTONOMIC DYSFUNCTION Physiological Systems Strannik Virtual scanning (SVS) Strannik light Therapy (SLT)
暂未订购
基于红外-可见光双波段的扫描型宽视场成像方法
13
作者 代少升 郑昭 +1 位作者 陈昌川 蒋大川 《半导体光电》 北大核心 2025年第5期884-891,共8页
针对目前红外成像设备中可见光与红外波段成像分辨率低、视场小以及图像位置映射关系不一致等问题,提出一种基于红外-可见光双波段的扫描型宽视场成像方法。该方法首先使用阵列传感器采集物体的可见光波段图像,使用单元红外探测器感应... 针对目前红外成像设备中可见光与红外波段成像分辨率低、视场小以及图像位置映射关系不一致等问题,提出一种基于红外-可见光双波段的扫描型宽视场成像方法。该方法首先使用阵列传感器采集物体的可见光波段图像,使用单元红外探测器感应目标的红外热辐射,并通过电机驱动,以线扫描方式实现红外波段成像;然后根据可见光像素均匀分布与红外像素等角度分布的特点,在像素世界坐标系上实现正圆切割映射;最后利用扫描角度温度模型对红外图像进行温度补偿。结果表明,所提方法可以有效同步的采集可见光与红外波段图像,使可见光与红外图像在长、宽视场角度上具有1∶1的映射比,对红外与可见光双波段成像推广应用具有参考意义。 展开更多
关键词 双波段 红外可见光 宽视场 温度补偿 扫描
原文传递
基于三维结构光扫描的泡沫混凝土冻融损伤演化特性 被引量:2
14
作者 周程涛 陈波 《复合材料学报》 北大核心 2025年第5期2764-2774,共11页
为了定量评价冻融环境下泡沫混凝土的表面损伤程度并探究其损伤演化特性,本文对冻融环境下密度为600 kg/cm^(3)和800 kg/cm^(3)的泡沫混凝土开展了三维结构光扫描试验、单轴压缩及相对动弹模量试验,借助Geomagic Studio及Cloud Compare... 为了定量评价冻融环境下泡沫混凝土的表面损伤程度并探究其损伤演化特性,本文对冻融环境下密度为600 kg/cm^(3)和800 kg/cm^(3)的泡沫混凝土开展了三维结构光扫描试验、单轴压缩及相对动弹模量试验,借助Geomagic Studio及Cloud Compare等软件对三维点云数据进行处理,基于坡度均方根Z_(2)、结构系数SF和粗糙轮廓系数R_(p)和三维粗糙度系数R_(3p)等参数定量分析了冻融环境下泡沫混凝土的表面形态和损伤特性。结果表明:泡沫混凝土表面损伤呈阶段性递次发展,破坏过程呈现出逐层剥落、由中部向两侧逐渐发育的特点;泡沫混凝土表面形貌参数与冻融循环次数正相关,低密度泡沫混凝土损伤速率更快,经历20次冻融循环后600 kg/m^(3)试件Z_(2)值增速较800 kg/m^(3)试件大35.44%;800 kg/cm^(3)泡沫混凝土形貌参数与抗压强度间的灰关联度更高,均在0.62以上;Z_(2)值与抗压强度保有率之间呈线性关系,相关系数达0.91以上。 展开更多
关键词 泡沫混凝土 冻融循环 三维结构光扫描 表面粗糙度 灰关联
原文传递
手持式结构光扫描系统设计与玉米叶面积提取 被引量:1
15
作者 彭星硕 杨悦 +2 位作者 张永亮 郭荣赓 耿楠 《农业机械学报》 北大核心 2025年第3期111-118,128,共9页
基于三维点云的叶面积提取方法具有非接触、高效率和高精度优势,能够更好地满足现代农业对叶面积快速获取和精准评估的需求。以大田全生育期夏玉米为研究对象,通过自主设计的手持式结构光作物三维扫描仪,采集夏玉米全生育期点云数据,并... 基于三维点云的叶面积提取方法具有非接触、高效率和高精度优势,能够更好地满足现代农业对叶面积快速获取和精准评估的需求。以大田全生育期夏玉米为研究对象,通过自主设计的手持式结构光作物三维扫描仪,采集夏玉米全生育期点云数据,并提出了点云配准、去噪和下采样等预处理流程。随后,应用点云分割网络对玉米作物器官点云进行了精确分割,成功提取了玉米叶片点云数据,并提取了叶面积。结果表明,分割网络在点云分割精度方面表现优异,叶片点云精确率、召回率、F1分数和交并比指标均超过95%,其他器官分割指标也均高于75%。不同生育期叶面积提取结果存在显著差异。在苗期、拔节期、全生育期模型表现较好,R^(2)分别为0.9062、0.9838、0.9949,均方根误差分别为221.34、172.77、206.64 cm^(2);但在成熟期,模型表现显著下降,R^(2)降至0.5178,RMSE上升至209.32 cm^(2)。不同施肥量下,叶面积提取结果整体良好,R^(2)均高于0.98。随着施肥量变化,均方根误差呈先下降后上升趋势,分别为176.38、106.36、110.18、270.34 cm^(2)。基于本文设计的设备和方法,能够准确有效地提取大田单株玉米叶面积,为智慧农业和表型机器人提供技术支持。 展开更多
关键词 夏玉米 生育期 叶面积 三维点云 点云分割 手持式结构光扫描系统
在线阅读 下载PDF
应用皮肤CT观察孙氏白癜风汤联合308 nm准分子光治疗白癜风的临床研究 被引量:1
16
作者 吴徐玲 吴红婷 +5 位作者 王子溪 周莹莹 方桢 朱红柳 高以红 毛秋霞 《中医药学报》 2025年第9期65-69,共5页
目的:应用皮肤CT观察孙氏白癜风汤联合308 nm准分子光治疗白癜风的皮损变化,评估其临床疗效及安全性。方法:选取2021年6月-2023年6月在江阴市中医院皮肤科门诊明确诊断为白癜风的患者80例,随机分成联合组和对照组,每组40例。联合组给予... 目的:应用皮肤CT观察孙氏白癜风汤联合308 nm准分子光治疗白癜风的皮损变化,评估其临床疗效及安全性。方法:选取2021年6月-2023年6月在江阴市中医院皮肤科门诊明确诊断为白癜风的患者80例,随机分成联合组和对照组,每组40例。联合组给予孙氏白癜风汤200 mL口服,分早晚口服,同时采用308 nm准分子光每周照射1次;对照组仅用308 nm准分子光,每周照射1次,连续治疗3个月,在治疗前及治疗后的每4周随防1次,共4次。治疗前后对血尿常规及肝肾功能进行监测,利用皮肤CT检测皮损处炎性细胞的浸润及黑素颗粒情况,并及时记录监测结果,对两组治疗前后各项指标进行比较,从而探索孙氏白癜风汤联合308 nm准分子光治疗白癜风的有效性及安全性。结果:治疗3个月后,两组的总有效率分别为87.5%(35/40)、65.0%(26/40),两组患者有效率差异有统计学意义(P<0.01)。联合组散发型、局限型、肢端型三型有效率分别为81.8%(9/11)、92.6%(25/27)、50.0%(1/2),组内比较无显著差异(P>0.05);对照组散发型、局限型、肢端型有效率分别为57.1%(8/14)、73.9%(17/23)、33.3%(1/3),有效率比较差异无统计学意义(P>0.05)。联合组及对照组治疗后色素恢复等级组间、组内前后比较,差异均有统计学意义(P<0.01)。治疗3个月后,联合组可显著减少炎症细胞的浸润,优于对照组(P<0.05)。结论:孙氏白癜风汤联合308 nm准分子光治疗白癜风疗效确切,可通过促进黑素细胞恢复,减少炎症细胞浸润,有效地改善白癜风患者的皮损状态。 展开更多
关键词 白癜风 孙氏白癜风汤 反射式共聚焦激光扫描显微镜 308 nm准分子光
暂未订购
数字自适应光学(特邀)
17
作者 吴嘉敏 翟焱望 +4 位作者 郭钰铎 唐若凡 赵灿兵 富振奇 戴琼海 《光学学报》 北大核心 2025年第19期69-81,共13页
光学像差是制约成像分辨率与信噪比的核心难题。传统自适应光学依赖波前传感器与可变形镜等器件进行模拟调制,虽然能够实现像差校正,但存在成本高、系统复杂和校正视场有限等问题。数字自适应光学通过超精细光场采集、解耦与计算融合,... 光学像差是制约成像分辨率与信噪比的核心难题。传统自适应光学依赖波前传感器与可变形镜等器件进行模拟调制,虽然能够实现像差校正,但存在成本高、系统复杂和校正视场有限等问题。数字自适应光学通过超精细光场采集、解耦与计算融合,能够实现基于数字调制的高速、多区域、非一致像差估计与校正。首先,介绍数字自适应光学的基本原理,梳理其与传统去模糊方法在采集机制和图像重建方面的区别。其次,开展仿真实验来比较两种方法在不同像差类型、不同像差强度下的像差校正性能及像差校正范围,并分析其根本原因。最后,探究数字自适应光学完成图像重建需要的最低信噪比边界,为未来光学成像系统工程应用提供理论模型和方法指导。 展开更多
关键词 光学像差 数字自适应光学 扫描光场成像 去模糊
原文传递
针尖增强纳米光谱术
18
作者 谢仲林 张恒 +4 位作者 雷博阳 魏雪桐 卢凡凡 梅霆 张文定 《光电工程》 北大核心 2025年第9期39-62,共24页
针尖增强纳米光谱术(Tip-enhanced nanospectroscopy,TENS)是一种结合扫描探针显微镜与针尖纳米聚焦光源的高空间分辨率光谱表征技术。该方法能够在纳米乃至亚纳米尺度上同步获取样品表面形貌与化学结构信息,为物理、化学、材料科学、... 针尖增强纳米光谱术(Tip-enhanced nanospectroscopy,TENS)是一种结合扫描探针显微镜与针尖纳米聚焦光源的高空间分辨率光谱表征技术。该方法能够在纳米乃至亚纳米尺度上同步获取样品表面形貌与化学结构信息,为物理、化学、材料科学、生物及纳米技术等多个前沿领域提供强有力的研究工具。首先概述了三种常用扫描探针显微镜的反馈原理;随后系统介绍了等离激元探针的类型、激发方式及其纳米聚焦特性;进一步详细讨论了多种典型TENS系统的构型与特点;最后综述了TENS在单分子成像、非线性光谱、相干反斯托克斯拉曼散射、荧光增强及暗态拉曼可视化等重要领域中的应用与前沿进展。 展开更多
关键词 针尖增强纳米光谱术 扫描探针显微镜 针尖纳米聚焦光源
在线阅读 下载PDF
Tip-enhanced Raman scattering of glucose molecules 被引量:3
19
作者 Zhonglin Xie Chao Meng +3 位作者 Donghua Yue Lei Xu Ting Mei Wending Zhang 《Opto-Electronic Science》 2025年第5期2-9,共8页
Glucose molecules are of great significance being one of the most important molecules in metabolic chain.However,due to the small Raman scattering cross-section and weak/non-adsorption on bare metals,accurately obtain... Glucose molecules are of great significance being one of the most important molecules in metabolic chain.However,due to the small Raman scattering cross-section and weak/non-adsorption on bare metals,accurately obtaining their"fingerprint information"remains a huge obstacle.Herein,we developed a tip-enhanced Raman scattering(TERS)technique to address this challenge.Adopting an optical fiber radial vector mode internally illuminates the plasmonic fiber tip to effectively suppress the background noise while generating a strong electric-field enhanced tip hotspot.Furthermore,the tip hotspot approaching the glucose molecules was manipulated via the shear-force feedback to provide more freedom for selecting substrates.Consequently,our TERS technique achieves the visualization of all Raman modes of glucose molecules within spectral window of 400-3200 cm^(-1),which is not achievable through the far-field/surface-enhanced Raman,or the existing TERS techniques.Our TERS technique offers a powerful tool for accurately identifying Raman scattering of molecules,paving the way for biomolecular analysis. 展开更多
关键词 tip-enhanced Raman scattering scanning near-field optical microscope fiber vector light field tip nanofocusing light source
在线阅读 下载PDF
上一页 1 2 26 下一页 到第
使用帮助 返回顶部