[ Objectives] This study was conducted to establish a method for microbial limit test of Tongmai Tangyanming Capsule. [ Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules, the microb...[ Objectives] This study was conducted to establish a method for microbial limit test of Tongmai Tangyanming Capsule. [ Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules, the microbiological limits of non-sterile products were verified. [ Results] Tongmai Tangyanming Capsule has a strong inhibitory effect on Bacillus subtilis and Candida albicans. The antimicrobial activity was significantly eliminated after increasing the diluent ( 1 : 20) ; and the recoveries were in the range of 0.5 -2 when the total quantities of aerobic microbes were determined by dilution method (1:20). When the total quantities of mould and yeast were determined by dilution method (1:20), the recoveries were from 0.5 to 2, and Escherichia coli, cholate-tolerant Gram-negative bacteria and Salmonella can be detected by the test solution dilution method. [ Condusions] With the plate method, the total quantities of aerobic bacteria and the quantities of mould and yeast were examined by increasing diluent, and conventional method was used for examination of control bacteria including E. coli, cholatetolerant Gram-negative bacteria and Salmonella. This method has been proved effective for microbial limit test of Tongmai Tangyanming Capsule, and can effectively control the quality of the preparation. The method is accurate and reliable.展开更多
[Objectives] This study was conducted to establish a method for microbial limit test of Compound Gangbangui Capsule. [Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules,the microbiol...[Objectives] This study was conducted to establish a method for microbial limit test of Compound Gangbangui Capsule. [Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules,the microbiological limits of non-sterile products were verified. [Results]Compound Gangbangui Capsule has a strong inhibitory effect on S. aureus,and the antimicrobial activity was significantly eliminated after increasing the diluent( 1∶ 20); and the recoveries were in the range of 0. 5-2. 0 when the total quantities of aerobic microbes were determined by dilution method( 1∶ 20). When the total quantities of mould and yeast were determined by conventional method( 1∶ 20),the recoveries were from 0. 5 to 2. 0,and Escherichia coli can be detected in experimental groups by the test solution dilution method. [Conclusions]With the plate method,the total quantities of aerobic bacteria and the quantities of mould and yeast were examined by increasing diluent and conventional method,respectively,and control bacteria,E. coli was examined by conventional method. This method has been proved effective for microbial limit test of Compound Gangbangui Capsule,and can effectively control the quality of the preparation. The method is accurate and reliable.展开更多
[Objectives] This study was conducted to establish a method for microbial limit test of Compound Yu E Nose Drops.[Methods] According to the Chinese Pharmacopoei (General Rules in the fourth part of the 2015 edition),t...[Objectives] This study was conducted to establish a method for microbial limit test of Compound Yu E Nose Drops.[Methods] According to the Chinese Pharmacopoei (General Rules in the fourth part of the 2015 edition),the microbial limit test method for Compound Yu E Nose Drops was verified.[Results] Compound Yu E Nose Drops has a strong inhibitory effect on Staphylococcus aureus and Bacillus subtilis,and the inhibitory activity was significantly eliminated after increasing the diluent (1∶ 20).The recoveries were all in the range of 0.5-2.0 when the total quantities of aerobic microbes were determined by the dilution method (1∶ 20).When the total quantities of mould and yeast were determined by the conventional method,the recoveries were both in the range of 0.5-2.0.When examining control bacteria,Escherichia coli,S.aureus and Pseudomonas aeruginosa can all be detected in the test groups by the test liquid dilution method.[Conclusions] For Compound Yu E Nose Drops,the total quantities of aerobic microbe can be counted by the dilution method;the quantities of mould and yeast can be examined by the conventional plate method;and the conventional method can be used for control microbe examination.展开更多
In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the fre...In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the free oscillation signal and employ the correlation method to estimate the amplitude of the modulation signal. The data analysis of an experiment shows that the uncertainties of amplitude components of the modulation signal obtained by the correlation method are in agreement with those due to white noise. The power spectral density of the modulation signal obtained by the correlation method is about one order higher than the thermal noise limit. It indicates that the correlation method is an effective way to estimate the amplitude of the modulation signal and it is instructive to conduct a high-accuracy WEP test.展开更多
基金Supported by Special Fund for Research and Development of Traditional Chinese Medicine Modern Science and Technology Industry of Guizhou Province(qkhzyz[2011]5012)
文摘[ Objectives] This study was conducted to establish a method for microbial limit test of Tongmai Tangyanming Capsule. [ Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules, the microbiological limits of non-sterile products were verified. [ Results] Tongmai Tangyanming Capsule has a strong inhibitory effect on Bacillus subtilis and Candida albicans. The antimicrobial activity was significantly eliminated after increasing the diluent ( 1 : 20) ; and the recoveries were in the range of 0.5 -2 when the total quantities of aerobic microbes were determined by dilution method (1:20). When the total quantities of mould and yeast were determined by dilution method (1:20), the recoveries were from 0.5 to 2, and Escherichia coli, cholate-tolerant Gram-negative bacteria and Salmonella can be detected by the test solution dilution method. [ Condusions] With the plate method, the total quantities of aerobic bacteria and the quantities of mould and yeast were examined by increasing diluent, and conventional method was used for examination of control bacteria including E. coli, cholatetolerant Gram-negative bacteria and Salmonella. This method has been proved effective for microbial limit test of Tongmai Tangyanming Capsule, and can effectively control the quality of the preparation. The method is accurate and reliable.
基金Supported by Traditional Chinese Medicine and Ethnic Minority Medicine Technique Research Subject of Guizhou Administrative Bureau of TCM(QZYY2011-40)
文摘[Objectives] This study was conducted to establish a method for microbial limit test of Compound Gangbangui Capsule. [Methods] According to the Chinese Pharmacopoei 2015 edition of the four general rules,the microbiological limits of non-sterile products were verified. [Results]Compound Gangbangui Capsule has a strong inhibitory effect on S. aureus,and the antimicrobial activity was significantly eliminated after increasing the diluent( 1∶ 20); and the recoveries were in the range of 0. 5-2. 0 when the total quantities of aerobic microbes were determined by dilution method( 1∶ 20). When the total quantities of mould and yeast were determined by conventional method( 1∶ 20),the recoveries were from 0. 5 to 2. 0,and Escherichia coli can be detected in experimental groups by the test solution dilution method. [Conclusions]With the plate method,the total quantities of aerobic bacteria and the quantities of mould and yeast were examined by increasing diluent and conventional method,respectively,and control bacteria,E. coli was examined by conventional method. This method has been proved effective for microbial limit test of Compound Gangbangui Capsule,and can effectively control the quality of the preparation. The method is accurate and reliable.
基金Supported by Traditional Chinese Medicine Modern Technology Industry Research and Development Special Project of Guizhou Province(QKHZYZ[2013]5018)First-class Construction Discipline Project of Guizhou Province(GNYL[2017]008)+1 种基金Traditional Chinese Medicine Characteristic Technology Inheriting Talent Project of State Administration of Traditional Chinese Medicine(GZYYRJH[2019]43)Traditional Chinese Medicine and Ethnic Minority Medicine Technique Research Subject of Guizhou Administrative Bureau of TCM(QZYY2013-75)
文摘[Objectives] This study was conducted to establish a method for microbial limit test of Compound Yu E Nose Drops.[Methods] According to the Chinese Pharmacopoei (General Rules in the fourth part of the 2015 edition),the microbial limit test method for Compound Yu E Nose Drops was verified.[Results] Compound Yu E Nose Drops has a strong inhibitory effect on Staphylococcus aureus and Bacillus subtilis,and the inhibitory activity was significantly eliminated after increasing the diluent (1∶ 20).The recoveries were all in the range of 0.5-2.0 when the total quantities of aerobic microbes were determined by the dilution method (1∶ 20).When the total quantities of mould and yeast were determined by the conventional method,the recoveries were both in the range of 0.5-2.0.When examining control bacteria,Escherichia coli,S.aureus and Pseudomonas aeruginosa can all be detected in the test groups by the test liquid dilution method.[Conclusions] For Compound Yu E Nose Drops,the total quantities of aerobic microbe can be counted by the dilution method;the quantities of mould and yeast can be examined by the conventional plate method;and the conventional method can be used for control microbe examination.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11575160,91636221,and 11605065)
文摘In a test of the weak equivalence principle (WEP) with a rotating torsion pendulum, it is important to estimate the amplitude of the modulation signal with high precision. We use a torsional filter to remove the free oscillation signal and employ the correlation method to estimate the amplitude of the modulation signal. The data analysis of an experiment shows that the uncertainties of amplitude components of the modulation signal obtained by the correlation method are in agreement with those due to white noise. The power spectral density of the modulation signal obtained by the correlation method is about one order higher than the thermal noise limit. It indicates that the correlation method is an effective way to estimate the amplitude of the modulation signal and it is instructive to conduct a high-accuracy WEP test.