<strong>Objective: </strong>The objective is to evaluate the visual acuity, high-order aberrations and satisfaction in the cataract patients with the implantation of different types of AcrySof blue light f...<strong>Objective: </strong>The objective is to evaluate the visual acuity, high-order aberrations and satisfaction in the cataract patients with the implantation of different types of AcrySof blue light filtering intraocular lens, which would provide the clinical guidance for the selection of individualized intraocular lens. <strong>Methods:</strong> From January 2019 to December 2020, the patients with age-related cataract in Guangzhou Red Cross Hospital were equally randomized to be divided into four groups. 20 patients (20 eyes) were implanted with AcrySof (SN60WF), which was the blue light filtering single focus group;20 patients (20 eyes) were implanted with blue light filtering aspheric multifocal intraocular lens (AcrySof ReSTOR IOL +3.0D, SN6AD1), which was the multifocal intraocular lens group;20 patients (20 eyes) were implanted with aspheric astigmatism correction intraocular lens (Toric SN6AT), which was the astigmatism group;20 patients (20 eyes) were implanted with blue filtering aspheric multifocal astigmatism correction intraocular lens (AcrySof ReSTOR IOL +2.5D IQ, SV25T0), which was the ART group. Three months after the operation, the patients were followed up with slit lamp to check the visual acuity, including uncorrected distance visual acuity (UCDVA), uncorrected near visual acuity (UCNVA), best corrected distance visual acuity, (BCDVA);the questionnaire surveys on the satisfaction of different intraocular lens implantation (far and near vision, glare, halo and abnormal visual symptoms);the iTrace visual function analyzer was used to check the total high-order aberrations (spherical aberration, wisdom aberration and Clover aberration) in the 3 mm pupil diameter. <strong>Results:</strong> Three months after cataract surgery, American Simplified version of questionnaire survey showed that the scores of near removing glasses in the multifocal group and the ART group were significantly better than those in the single focus group and the astigmatism group (<em>P</em> < 0.05);there was no significant difference in the satisfaction of far removing glasses, glare and halo in each group (<em>P</em> > 0.05). Three months after cataract surgery, there were statistically significant differences about UCDVA, BCDVA and UCNVA among the four groups (<em>F</em> = 18.189, <em>P </em>< 0.001), the UCNVA in the multifocal group and ART group was significantly better than that in the single focus group and the astigmatism group (<em>P</em> < 0.01). The difference of higher-order aberrations (total higher-order aberrations, wisdom aberrations, spherical aberrations, clover aberrations) was no statistically significant among the four groups (<em>P</em> > 0.05). <strong>Conclusion: </strong>Different types of AcrySof blue light filtering intraocular lens implantation could improve the far vision and satisfaction of cataract patients, without different higher-order aberrations. Multifocal intraocular lens and ART intraocular lens could significantly improve the far vision of patients and reduce the dependence on near glasses.展开更多
The visual noise of each light intensity area is different when the image is drawn by Monte Carlo method.However,the existing denoising algorithms have limited denoising performance under complex lighting conditions a...The visual noise of each light intensity area is different when the image is drawn by Monte Carlo method.However,the existing denoising algorithms have limited denoising performance under complex lighting conditions and are easy to lose detailed information.So we propose a rendered image denoising method with filtering guided by lighting information.First,we design an image segmentation algorithm based on lighting information to segment the image into different illumination areas.Then,we establish the parameter prediction model guided by lighting information for filtering(PGLF)to predict the filtering parameters of different illumination areas.For different illumination areas,we use these filtering parameters to construct area filters,and the filters are guided by the lighting information to perform sub-area filtering.Finally,the filtering results are fused with auxiliary features to output denoised images for improving the overall denoising effect of the image.Under the physically based rendering tool(PBRT)scene and Tungsten dataset,the experimental results show that compared with other guided filtering denoising methods,our method improves the peak signal-to-noise ratio(PSNR)metrics by 4.2164 dB on average and the structural similarity index(SSIM)metrics by 7.8%on average.This shows that our method can better reduce the noise in complex lighting scenesand improvethe imagequality.展开更多
A new complex,Co(0.5)Ni(0.5)(C2H6N2O)6SO4(Ⅰ), was synthesized and its single crystal was obtained from aqueous solution by evaporating solvent slowly. Single-crystal X-ray analysis revealed that the complex b...A new complex,Co(0.5)Ni(0.5)(C2H6N2O)6SO4(Ⅰ), was synthesized and its single crystal was obtained from aqueous solution by evaporating solvent slowly. Single-crystal X-ray analysis revealed that the complex belongs to trigonal system, space group R-3c, with a = b = 10.999(2) A, c = 40.439(13) A, V = 4237(2)A3, Z = 6, Dc = 1.410 g/cm3, Mr = 599.41, μ = 0.785 mm-1, F(000) = 1893, the final R = 0.0330 and wR = 0.0926(I 〉 2σ(I)). IR spectrum and compositional analyses(elemental analyzer and ICP) were used to characterize the composition of the product. TGA(Thermal Gravimetric Analysis) showed that complex Ⅰ remained stable until it is heated up to 200 ℃, indicating its good thermostability. The main transmission peak of complex Ⅰ in UV-Vis spectrum appeared at 290 nm, making it an eligible material for ultraviolet light filters(ULF).展开更多
A new coordination compound, Ni(C6H12N4)2SO4.4H20(NSH-HMTA) (HMTA, hexamethylenetetramine, C6H12N4), has been synthesized and its single crystals were obtained. NSH-HMTA belongs to the triclinic system, space gr...A new coordination compound, Ni(C6H12N4)2SO4.4H20(NSH-HMTA) (HMTA, hexamethylenetetramine, C6H12N4), has been synthesized and its single crystals were obtained. NSH-HMTA belongs to the triclinic system, space group Pi with a = 9.2534(6), b = 13.3131(2), c = 16.0373(2) A, α = 65.981(6), β = 89.792(3), γ = 89.677(4)°, Mr= 880.2, Z = 2, V= 1804.6(3) A3, μ = 1.254 mm-1, F(000) = 932, R = 0.0555 (1 〉 2σ(I)) and wR = 0.1908 for 19343 observed reflections. HMTA substitutes for water molecules are located at the para-positions, forming a stretching octahedral nickel ion unit. Thermo-gravimetric analysis shows that the dehydration temperature of NSH-HMTA is about 92℃. The characteristic UV peaks are approximately 10 nm red-shifted by the absorption of octahedral HMTA complex ion units.展开更多
Benzophenone ultraviolet light filters(BPs)are high-production-volume chemicals extensively used in personal care products,leading to widespread human exposure.Given their estrogenic properties,the potential health ri...Benzophenone ultraviolet light filters(BPs)are high-production-volume chemicals extensively used in personal care products,leading to widespread human exposure.Given their estrogenic properties,the potential health risks associated with exposure to BPs have become a public health concern.This review aims to summarize sources and pathways of exposure to BPs and associated health risks.Dermal exposure,primarily through the use of sunscreens,constitutes a major pathway for BP exposure.At a recommended application rate,dermal exposure of BP-3 via the application of sunscreens may reach or exceed the suggested reference dose.Other exposure pathways to BPs,such as drinking water,seafood,and packaged foods,contribute minimal to the overall dose.Inhalation is a minor pathway of exposure;however,its contribution cannot be ignored.Human exposure to BPs is an order of magnitude higher in North America than in Asia and Europe.Studies conducted on laboratory animals and cells have consistently demonstrated the toxic effects of BP exposure.BPs are estrogenic and elicit reproductive and developmental toxicities.Furthermore,neurotoxicity,hepatotoxicity,nephrotoxicity,and carcinogenicity have been reported from chronic BP exposure.In addition to animal and cell studies,epidemiological investigations have identified associations between BPs and couples'fecundity and other reproductive disorders,as well as adverse birth outcomes.Further studies are urgently needed to understand the risks posed by BPs on human health.展开更多
Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and se...Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and select the lowest points in the grids to reconstruct TIN in the process of iteration. Compared with the classic filter of progressive TIN densification(PTD), the improved method can filter out attached objects, avoid the interference of low objects and obtain relatively smooth bare-earth. In addition, this proposed filter can reduce memory requirements and be more efficient in processing huge data volume. The experimental results show that the filtering accuracy and efficiency of this method is higher than that of the PTD method.展开更多
文摘<strong>Objective: </strong>The objective is to evaluate the visual acuity, high-order aberrations and satisfaction in the cataract patients with the implantation of different types of AcrySof blue light filtering intraocular lens, which would provide the clinical guidance for the selection of individualized intraocular lens. <strong>Methods:</strong> From January 2019 to December 2020, the patients with age-related cataract in Guangzhou Red Cross Hospital were equally randomized to be divided into four groups. 20 patients (20 eyes) were implanted with AcrySof (SN60WF), which was the blue light filtering single focus group;20 patients (20 eyes) were implanted with blue light filtering aspheric multifocal intraocular lens (AcrySof ReSTOR IOL +3.0D, SN6AD1), which was the multifocal intraocular lens group;20 patients (20 eyes) were implanted with aspheric astigmatism correction intraocular lens (Toric SN6AT), which was the astigmatism group;20 patients (20 eyes) were implanted with blue filtering aspheric multifocal astigmatism correction intraocular lens (AcrySof ReSTOR IOL +2.5D IQ, SV25T0), which was the ART group. Three months after the operation, the patients were followed up with slit lamp to check the visual acuity, including uncorrected distance visual acuity (UCDVA), uncorrected near visual acuity (UCNVA), best corrected distance visual acuity, (BCDVA);the questionnaire surveys on the satisfaction of different intraocular lens implantation (far and near vision, glare, halo and abnormal visual symptoms);the iTrace visual function analyzer was used to check the total high-order aberrations (spherical aberration, wisdom aberration and Clover aberration) in the 3 mm pupil diameter. <strong>Results:</strong> Three months after cataract surgery, American Simplified version of questionnaire survey showed that the scores of near removing glasses in the multifocal group and the ART group were significantly better than those in the single focus group and the astigmatism group (<em>P</em> < 0.05);there was no significant difference in the satisfaction of far removing glasses, glare and halo in each group (<em>P</em> > 0.05). Three months after cataract surgery, there were statistically significant differences about UCDVA, BCDVA and UCNVA among the four groups (<em>F</em> = 18.189, <em>P </em>< 0.001), the UCNVA in the multifocal group and ART group was significantly better than that in the single focus group and the astigmatism group (<em>P</em> < 0.01). The difference of higher-order aberrations (total higher-order aberrations, wisdom aberrations, spherical aberrations, clover aberrations) was no statistically significant among the four groups (<em>P</em> > 0.05). <strong>Conclusion: </strong>Different types of AcrySof blue light filtering intraocular lens implantation could improve the far vision and satisfaction of cataract patients, without different higher-order aberrations. Multifocal intraocular lens and ART intraocular lens could significantly improve the far vision of patients and reduce the dependence on near glasses.
基金supported by the National Natural Science(No.U19A2063)the Jilin Provincial Development Program of Science and Technology (No.20230201080GX)the Jilin Province Education Department Scientific Research Project (No.JJKH20230851KJ)。
文摘The visual noise of each light intensity area is different when the image is drawn by Monte Carlo method.However,the existing denoising algorithms have limited denoising performance under complex lighting conditions and are easy to lose detailed information.So we propose a rendered image denoising method with filtering guided by lighting information.First,we design an image segmentation algorithm based on lighting information to segment the image into different illumination areas.Then,we establish the parameter prediction model guided by lighting information for filtering(PGLF)to predict the filtering parameters of different illumination areas.For different illumination areas,we use these filtering parameters to construct area filters,and the filters are guided by the lighting information to perform sub-area filtering.Finally,the filtering results are fused with auxiliary features to output denoised images for improving the overall denoising effect of the image.Under the physically based rendering tool(PBRT)scene and Tungsten dataset,the experimental results show that compared with other guided filtering denoising methods,our method improves the peak signal-to-noise ratio(PSNR)metrics by 4.2164 dB on average and the structural similarity index(SSIM)metrics by 7.8%on average.This shows that our method can better reduce the noise in complex lighting scenesand improvethe imagequality.
基金Supported by Key Laboratory of Optoelectronic Materials Chemistry and Physics,Chinese Academy of Sciences
文摘A new complex,Co(0.5)Ni(0.5)(C2H6N2O)6SO4(Ⅰ), was synthesized and its single crystal was obtained from aqueous solution by evaporating solvent slowly. Single-crystal X-ray analysis revealed that the complex belongs to trigonal system, space group R-3c, with a = b = 10.999(2) A, c = 40.439(13) A, V = 4237(2)A3, Z = 6, Dc = 1.410 g/cm3, Mr = 599.41, μ = 0.785 mm-1, F(000) = 1893, the final R = 0.0330 and wR = 0.0926(I 〉 2σ(I)). IR spectrum and compositional analyses(elemental analyzer and ICP) were used to characterize the composition of the product. TGA(Thermal Gravimetric Analysis) showed that complex Ⅰ remained stable until it is heated up to 200 ℃, indicating its good thermostability. The main transmission peak of complex Ⅰ in UV-Vis spectrum appeared at 290 nm, making it an eligible material for ultraviolet light filters(ULF).
基金Supported by Key Laboratory of Optoelectronic Materials Chemistry and Physics,Chinese Academy of Sciences
文摘A new coordination compound, Ni(C6H12N4)2SO4.4H20(NSH-HMTA) (HMTA, hexamethylenetetramine, C6H12N4), has been synthesized and its single crystals were obtained. NSH-HMTA belongs to the triclinic system, space group Pi with a = 9.2534(6), b = 13.3131(2), c = 16.0373(2) A, α = 65.981(6), β = 89.792(3), γ = 89.677(4)°, Mr= 880.2, Z = 2, V= 1804.6(3) A3, μ = 1.254 mm-1, F(000) = 932, R = 0.0555 (1 〉 2σ(I)) and wR = 0.1908 for 19343 observed reflections. HMTA substitutes for water molecules are located at the para-positions, forming a stretching octahedral nickel ion unit. Thermo-gravimetric analysis shows that the dehydration temperature of NSH-HMTA is about 92℃. The characteristic UV peaks are approximately 10 nm red-shifted by the absorption of octahedral HMTA complex ion units.
基金supported by the Natural Science Foundation of China(No.22022612,and No.21677184)Natural Science Foundation of Guangdong Province,China(No.2020A0104006 and No.2021A1515010243)+1 种基金the Fundamental Research Funds for the Central Universitiessupported,in part,by the National Institute of Environmental Health Sciences(NIEHS)under award number U2CES026542(KK).
文摘Benzophenone ultraviolet light filters(BPs)are high-production-volume chemicals extensively used in personal care products,leading to widespread human exposure.Given their estrogenic properties,the potential health risks associated with exposure to BPs have become a public health concern.This review aims to summarize sources and pathways of exposure to BPs and associated health risks.Dermal exposure,primarily through the use of sunscreens,constitutes a major pathway for BP exposure.At a recommended application rate,dermal exposure of BP-3 via the application of sunscreens may reach or exceed the suggested reference dose.Other exposure pathways to BPs,such as drinking water,seafood,and packaged foods,contribute minimal to the overall dose.Inhalation is a minor pathway of exposure;however,its contribution cannot be ignored.Human exposure to BPs is an order of magnitude higher in North America than in Asia and Europe.Studies conducted on laboratory animals and cells have consistently demonstrated the toxic effects of BP exposure.BPs are estrogenic and elicit reproductive and developmental toxicities.Furthermore,neurotoxicity,hepatotoxicity,nephrotoxicity,and carcinogenicity have been reported from chronic BP exposure.In addition to animal and cell studies,epidemiological investigations have identified associations between BPs and couples'fecundity and other reproductive disorders,as well as adverse birth outcomes.Further studies are urgently needed to understand the risks posed by BPs on human health.
基金Supported by the National Natural Science Foundation of China(41301519)
文摘Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and select the lowest points in the grids to reconstruct TIN in the process of iteration. Compared with the classic filter of progressive TIN densification(PTD), the improved method can filter out attached objects, avoid the interference of low objects and obtain relatively smooth bare-earth. In addition, this proposed filter can reduce memory requirements and be more efficient in processing huge data volume. The experimental results show that the filtering accuracy and efficiency of this method is higher than that of the PTD method.