The performance enhancement of MXene/semiconductor heterostructure-based light detectors is greatly restricted by the relatively small junction barrier due to the limited work function of MXenes.The work function of M...The performance enhancement of MXene/semiconductor heterostructure-based light detectors is greatly restricted by the relatively small junction barrier due to the limited work function of MXenes.The work function of MXenes can be largely adjusted to approach 600 meV through simple incorporation of V_(2)O_(5) via a charge transfer doping mechanism.Exploiting this strategy,the performance of MXene/GaN heterostructure-based deep ultraviolet(DUV)photodetectors has been greatly improved.Specifically,the photocurrent is enhanced by nearly 3 times,and the dark current is suppressed at the lowest order of magnitude,resulting in improved responsivity and specific detectivity of 121.6 mA/W and 2.23×10^(13) Jones,respectively,at 265 nm.The device also displays an ultralow dark current of 10^(-14) A,a fast response speed of 0.4 ms/15.1 ms,a large linear dynamic range exceeding 150 dB,and a high DUV/near ultraviolet rejection ratio of 2.41×10^(5).Owing to its good device performance,the detector is capable of sensing weak photon signals produced by a fire flame and functions as an optical receiver to transmit a text signal in a DUV light communication system.The proposed MXene doping method is expected to help develop MXene-based electronic/optoelectronic devices,and the present DUV photodetectors will find potential applications in DUV optoelectronic systems.展开更多
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids we...Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30 ℃ and low temperature evaporative light scattering detector(40 ℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).展开更多
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ...[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.展开更多
A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulatio...A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulations(injections,capsules and tablets)without any pretreatment or derivatization step.Azithromycin,degradation products and formulation ingredients were separated efficiently by using the mobile phase consisted of ammonium acetate(0.05 M,pH 8.0)and acetonitrile(60:40,v/v)in an isocratic mode at 0.8 ml/min flow rate.Parameters of ELSD were 60C for evaporation temperature and 50 psi for pressure of carrier gas(air).A logarithmic calibration curve was obtained from 50.93 to 509.30 mg/ml(r¼0.9996)for azithromycin,with the limit of detection(LOD)of 6.75 mg/ml(S/n¼3)and the limit of quantification of 22.50 mg/ml(S/n¼10).The developed method was validated and applied with satisfactory accuracy and precision for the determination of azithromycin in raw materials and pharmaceutical formulations(recovery 99e102%,RSD<1.2%,n¼3).No significant difference(t-test)was found between the results of the developed HPLCeELSD method and the HPLCeUV or microbiological method.展开更多
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,...A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.展开更多
Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the ...Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the necessity to further improve the optical transparency of high-quality LAB. In order to study high optical transparencies, we continuously improve our measurement setup and use monochromatic light to measure the attenuation lengths of LAB samples. Moreover, the effects of organic impurities on LAB samples are studied to understand their interaction mechanisms and further improve the optical transparency of LAB.展开更多
Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling...Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.展开更多
基金financially supported by the National Natural Science Foundation of China(NSFC,62275002,51902078)the Anhui Provincial Natural Science Foundation(2008085MF205)the Fundamental Research Funds for the Central Universities(JZ2020HGTB0051)。
文摘The performance enhancement of MXene/semiconductor heterostructure-based light detectors is greatly restricted by the relatively small junction barrier due to the limited work function of MXenes.The work function of MXenes can be largely adjusted to approach 600 meV through simple incorporation of V_(2)O_(5) via a charge transfer doping mechanism.Exploiting this strategy,the performance of MXene/GaN heterostructure-based deep ultraviolet(DUV)photodetectors has been greatly improved.Specifically,the photocurrent is enhanced by nearly 3 times,and the dark current is suppressed at the lowest order of magnitude,resulting in improved responsivity and specific detectivity of 121.6 mA/W and 2.23×10^(13) Jones,respectively,at 265 nm.The device also displays an ultralow dark current of 10^(-14) A,a fast response speed of 0.4 ms/15.1 ms,a large linear dynamic range exceeding 150 dB,and a high DUV/near ultraviolet rejection ratio of 2.41×10^(5).Owing to its good device performance,the detector is capable of sensing weak photon signals produced by a fire flame and functions as an optical receiver to transmit a text signal in a DUV light communication system.The proposed MXene doping method is expected to help develop MXene-based electronic/optoelectronic devices,and the present DUV photodetectors will find potential applications in DUV optoelectronic systems.
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
文摘Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30 ℃ and low temperature evaporative light scattering detector(40 ℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).
文摘[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.
基金National Natural Science Foundations of China(No.81173024)to professor Qiang Fu is gratefully acknowledged.The authors also thank Xi’an Insti-tute of Food and Drug Control for providing the facilities and necessary equipments.
文摘A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulations(injections,capsules and tablets)without any pretreatment or derivatization step.Azithromycin,degradation products and formulation ingredients were separated efficiently by using the mobile phase consisted of ammonium acetate(0.05 M,pH 8.0)and acetonitrile(60:40,v/v)in an isocratic mode at 0.8 ml/min flow rate.Parameters of ELSD were 60C for evaporation temperature and 50 psi for pressure of carrier gas(air).A logarithmic calibration curve was obtained from 50.93 to 509.30 mg/ml(r¼0.9996)for azithromycin,with the limit of detection(LOD)of 6.75 mg/ml(S/n¼3)and the limit of quantification of 22.50 mg/ml(S/n¼10).The developed method was validated and applied with satisfactory accuracy and precision for the determination of azithromycin in raw materials and pharmaceutical formulations(recovery 99e102%,RSD<1.2%,n¼3).No significant difference(t-test)was found between the results of the developed HPLCeELSD method and the HPLCeUV or microbiological method.
基金supported by the Major program of Natural Science Foundation of Shandong Province(No.ZR2020ZD30)the National Natural Science Foundation of China(Nos.11775133,U2167202,U1432119).
文摘A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.
基金supported by the National 973 Project Foundation of the Ministry of Science and Technology of China(No.2013CB834300)Strategic Pilot Science and Technology Project of the CAS(No.XDA10010000)the National Natural Science Foundation of China(No.116201 004)
文摘Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the necessity to further improve the optical transparency of high-quality LAB. In order to study high optical transparencies, we continuously improve our measurement setup and use monochromatic light to measure the attenuation lengths of LAB samples. Moreover, the effects of organic impurities on LAB samples are studied to understand their interaction mechanisms and further improve the optical transparency of LAB.
基金supported by the Fundamental Research Funds for the Central Universities,China(Grant No.AUGA5710056414)the Program for Innovation Research of Science in Harbin Institute of Technology(Grant Nos.PIRS OF HIT A201412 and PIRS OF HIT Q201505)+3 种基金the National Natural Science Foundation of China(Grant No.11675046)the Doctoral Fund of the Ministry of Education of China(Grant No.20122302120003)the Natural Science Foundation of Heilongjiang Province of China(Grant No.A201303)the Postdoctoral Scientific Research Developmental Fund of Heilongjiang Province,China(Grant No.LBH-Q15060)
文摘Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.