期刊文献+
共找到2,187篇文章
< 1 2 110 >
每页显示 20 50 100
Implementation of Phase Generated Carrier Technique for FBG Laser Sensor Multiplexed System Based on Compact RIO 被引量:1
1
作者 Lei Feng Jun He Jing-Yuan Duan Fang Li Yu-Liang Liu 《Journal of Electronic Science and Technology of China》 2008年第4期385-388,共4页
This paper presents the fundamental technique of phase generated carrier (PGC) and its realization on compact reconfigurable input and output (RIO) which adopts real-time and field programmable grate array (FPGA... This paper presents the fundamental technique of phase generated carrier (PGC) and its realization on compact reconfigurable input and output (RIO) which adopts real-time and field programmable grate array (FPGA) techniques. Improvement of the PGC technique is also introduced by using peak-to-peak value detection method to reduce the influence of variation of the light intensity. A four-element fibre Bragg gratings (FBG) laser sensor system is conducted in the experiment and the demodulated results demonstrate correlation coefficient as high as 0.995 with the reference signal and the dynamic range to be 120dB@63Hz. 展开更多
关键词 Compact reconfigurable input andoutput (RIO) demodulation fibre Bragg gratings(FBG) laser sensor multiplexed system phase generatedcarrier (PGC).
在线阅读 下载PDF
Design and application of thickness measurement calibration system based on laser displacement sensor 被引量:2
2
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
在线阅读 下载PDF
Fiber Laser Sensor Based on a Phase-Shifted Chirped Grating for Acoustic Sensing of Partial Discharges 被引量:5
3
作者 Sanderson E. U. LIMA Rubem G FARIAS +4 位作者 Francisco M. ARAUJO Luis A. FERREIRA José L. SANTOS Vladimiro MIRANDA1 Orlando FRAZAO 《Photonic Sensors》 SCIE EI CAS 2013年第1期44-51,共8页
Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power tr... Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions. 展开更多
关键词 Transformer insulation partial discharges acoustic detection fiber laser sensors
原文传递
High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor 被引量:2
4
作者 Christoph Vannahme Martin Dufva Anders Kristensen 《Light(Science & Applications)》 SCIE EI CAS CSCD 2015年第1期410-414,共5页
High frame rate and highly sensitive imaging of refractive index changes on a surface is very promising for studying the dynamics of dissolution,mixing and biological processes without the need for labeling.Here,a hig... High frame rate and highly sensitive imaging of refractive index changes on a surface is very promising for studying the dynamics of dissolution,mixing and biological processes without the need for labeling.Here,a highly sensitive distributed feedback(DFB)dye laser sensor for high frame rate imaging refractometry without moving parts is presented.DFB dye lasers are low-cost and highly sensitive refractive index sensors.The unique multi-wavelength DFB laser structure presented here comprises several areas with different grating periods.Imagingin two dimensions of space is enabled by analyzinglaser light from all areasin parallelwith an imaging spectrometer.With this multi-resonance imaging refractometry method,the spatial position in one direction is identified from the horizontal,i.e.,spectral position of the multiple laser lines which is obtained from the spectrometer charged coupled device(CCD)array.The orthogonal spatial position is obtained from the vertical spatial position on the spectrometer CCD array as in established spatially resolved spectroscopy.Here,the imaging technique is demonstrated by monitoring the motion of small sucrose molecules upon dissolution of solid sucrose in water.The omission of moving parts improves the robustness of the imaging system and allows a very high frame rate of up to 12 Hz. 展开更多
关键词 distributed feedback laser label-free imaging laser sensor refractive index sensor
原文传递
A Rapid Calibration Technique for Scanning Line-Structured Laser Sensor
5
作者 Li Tao, Changku Sun, ZhiqinXu, Wei Wei State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期839-840,共2页
A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters ... A novel procedure to calibrate the scanning line-structured laser sensor is presented. A drone composed of two orthogonal planes is designed, with the result that camera parameters and light-plane equation parameters is achieved simultaneously. 展开更多
关键词 for in of on BE AS LINE A Rapid Calibration Technique for Scanning Line-Structured laser sensor
原文传递
DFB fiber laser sensor for simultaneous measurement of acoustic and magnetic fields
6
作者 Rui Ma Wentao Zhang +1 位作者 Wenzhu Huang Fang Li 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第6期24-28,共5页
A novel distributed feedback(DFB) fiber laser sensor, which can measure acoustic and magnetic fields simultaneously, is proposed. The magnetic field can be measured by detecting the change of resonant frequency of t... A novel distributed feedback(DFB) fiber laser sensor, which can measure acoustic and magnetic fields simultaneously, is proposed. The magnetic field can be measured by detecting the change of resonant frequency of the fiber laser, and the acoustic pressure can be measured by detecting the phase shift of the fiber laser. Both of the signals can be simultaneously demodulated in the frequency domain without affecting each other. Experimental studies show that the acoustic pressure sensitivity of this sensor is about-130 d B(0 dB re 1 pm∕μPa) and the sensor has a good linearity with a magnetic field sensitivity of 0.57 Hz∕mT. 展开更多
关键词 LENGTH DFB fiber laser sensor for simultaneous measurement of acoustic and magnetic fields
原文传递
Deformation analysis of the flexspline of harmonic drive gears considering the driving speed effect using laser sensors 被引量:10
7
作者 MA DongHui WU JiaNing +1 位作者 LIU Tao YAN ShaoZe 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2017年第8期1175-1187,共13页
Accurate description of the elastic deformation of the flexspline is the foundation for optimization design of the structure and conjugate profiles of the harmonic drive gear. This paper proposed an experimental metho... Accurate description of the elastic deformation of the flexspline is the foundation for optimization design of the structure and conjugate profiles of the harmonic drive gear. This paper proposed an experimental method to investigate the effect of the driving speed on the deformation characteristics of the flexspline. First, an experimental apparatus that integrates a special-fabricated micro-displacement platform and a pair of laser displacement sensors is developed, and the radial displacement of the flexspline is measured in vertical and horizontal directions. Next, the deformation analyses of the flexspline at different driving speeds are performed with our method and the conventional method, and the comparison results reveal that the radial displacement of the flexspline is actually composed of both harmonic and random components, and the amplitude decreases and tends to zero with the increase of the driving speed, especially near the closed end of the flexspline. Last, the mechanisms of the inherent multi-frequency and amplitude attenuation characteristics of the radial displacement of the flexspline are discussed. It is indicated that the impact and friction existing in the flexible bearing of the wave generator is likely responsible for the existence of the random component, and the assumption of linear distribution of the ftexspline deformation along the rotating axis is invalid under high speed condition. Our research promotes the further study on the contact-impact problem of the flexible bearing of the wave generator and the transfer characteristic of the elastic deformation of the flexspline. 展开更多
关键词 harmonic drive gear FLEXSPLINE radial displacement driving speed laser displacement sensor flexible bearing
原文传递
Extrinsic calibration of a laser displacement sensor in a non-contact coordinate measuring machine 被引量:12
8
作者 Chao BI Jianguo FANG +1 位作者 Kun LI Zhijun GUO 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2017年第4期1528-1537,共10页
In order to implement 3D scanning of those complicated parts such as blades in the aviation field,a non-contact optical measuring system is established in the paper,which integrates a laser displacement sensor,a probe... In order to implement 3D scanning of those complicated parts such as blades in the aviation field,a non-contact optical measuring system is established in the paper,which integrates a laser displacement sensor,a probe head,the frame of a coordinate measuring machine(CMM),etc.As the output of the laser sensor directly obtained possesses the 1D length of the laser beam,it needs to determine the unit direction vector of the laser beam denoted as(l,m,n)by calibration so as to convert the 1D values into 3D coordinates of target points.Therefore,an extrinsic calibration method based on a standard sphere is proposed to accomplish this task in the paper.During the calibration procedure,the laser sensor moves along with the motion of the CMM and gathers the required data on the spherical surface.Then,both the output of the laser sensor and the grating readings of the CMM are substituted into the constraint equation of the spherical surface,in which an over-determined nonlinear equation group containing unknown parameters is established.For the purpose of solving the equation group,a method based on non-linear least squares optimization is put forward.Finally,the system after calibration is utilized to measure the diameter of a metallic sphere 10 times from different orientations to verify the calibration accuracy.In the experiment,the errors between the measured results and the true values are all smaller than 0.03 mm,which manifests the validity and practicality of the extrinsic calibration method presented in the paper. 展开更多
关键词 CMM 3D scanning Extrinsic calibration laser displacement sensor Non-linear least squares
原文传递
IABC: An iteratively automatic machine learning boosted hand-eye calibration method for laser displacement sensor 被引量:2
9
作者 Helin LI Bin LIN +6 位作者 Tianyi SUI Liang XU Chen ZHANG Shuai YAN Yang WANG Xinquan HAO Deyu LOU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第8期422-453,共32页
An on-machine measuring(OMM)system with a laser displacement sensor(LDS)is designed for measuring free-form surfaces of hypersonic aircraft’s radomes.To improve the measurement accuracy of the OMM system,a novel Iter... An on-machine measuring(OMM)system with a laser displacement sensor(LDS)is designed for measuring free-form surfaces of hypersonic aircraft’s radomes.To improve the measurement accuracy of the OMM system,a novel Iteratively Automatic machine learning Boosted hand-eye Calibration(IABC)method is proposed.Both the hand-eye relationship and LDS measurement errors can be calibrated in one calibration process without any hardware changes via IABC.Firstly,a new objective function is derived,containing analytical parameters of the handeye relationship and LDS errors.Then,a hybrid calibration model composed of two kernels is proposed to solve the objective function.One kernel is the analytical kernel designed for solving analytical parameters.Another kernel is the automatic machine learning(AutoML)kernel designed to model LDS errors.The two kernels are connected with stepwise iterations to find the best calibration results.Compared with traditional methods,hand-eye experiments show that IABC reduces the calibration RMSE by about 50%.Verification experiments show that IABC reduces the measurement deviations by about 25%-50%and RMSEs within 40%.Even when the training data are obviously less than the test data,IABC performs well.Experiments demonstrate that IABC is more accurate than traditional hand-eye methods. 展开更多
关键词 Hand-Eye Calibration laser Displacement sensor Machine learning Measurement errors On-Machine Measurement
原文传递
Laser-Assisted Reduction of Highly Conductive Circuits Based on Copper Nitrate for Flexible Printed Sensors 被引量:12
10
作者 Shi Bai Shigang Zhang +4 位作者 Weiping Zhou Delong Ma Ying Ma Pooran Joshi Anming Hu 《Nano-Micro Letters》 SCIE EI CAS 2017年第4期49-61,共13页
Stretchable electronic sensing devices are defining the path toward wearable electronics. High-performance flexible strain sensors attached on clothing or human skin are required for potential applications in the ente... Stretchable electronic sensing devices are defining the path toward wearable electronics. High-performance flexible strain sensors attached on clothing or human skin are required for potential applications in the entertainment,health monitoring, and medical care sectors. In this work,conducting copper electrodes were fabricated onpolydimethylsiloxane as sensitive stretchable microsensors by integrating laser direct writing and transfer printing approaches. The copper electrode was reduced from copper salt using laser writing rather than the general approach of printing with pre-synthesized copper or copper oxide nanoparticles. An electrical resistivity of 96 l X cm was achieved on 40-lm-thick Cu electrodes on flexible substrates. The motion sensing functionality successfully demonstrated a high sensitivity and mechanical robustness.This in situ fabrication method leads to a path toward electronic devices on flexible substrates. 展开更多
关键词 laser direct writing Copper circuit Stretchable sensor laser reduction
在线阅读 下载PDF
Flexible Scanning Method by Integrating Laser Line Sensors with Articulated Arm Coordinate Measuring Machines 被引量:2
11
作者 Zexiao Xie Ping Yu +2 位作者 Hanlei Gong Shukai Chi Xiang Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第5期131-140,共10页
Measuring and reconstructing the shape of workpieces have been considered as a fundamental step in both reverse engineering and product quality control.Owing to increasing structural complexity of recent products,meas... Measuring and reconstructing the shape of workpieces have been considered as a fundamental step in both reverse engineering and product quality control.Owing to increasing structural complexity of recent products,measurements from multiple directions are typically required in current scanning techniques.Specifically,the plane structured light can be applied to measure one area of a part at a time,with an additional algorithm required to merge the collected data of each area.Alternatively,the line structured light sensor integrated on CNC machines or CMMs could also realize multi-view measurement.However,the system needs to be repeatedly calibrated at each new direction.This paper presents a flexible scanning method by integrating laser line sensors with articulated arm coordinate measuring machines(AACMM).Since the output of the laser line sensor is 2D raw data in the laser plane,our system model introduces an explicit transformation from the 2D sensor coordinate frame to the 3D base coordinate frame of the AACMM(i.e.,the translation and rotation the of the 2D sensor coordinate in the sixth coordinate system of AACMM).To solve the model,the“conjugate pairs”are proposed and identified by measuring a fixed point(e.g.,a sphere center).Moreover,a search algorithm is adopted to find the optimal solution,which noticeably boosts the model accuracy.The experimental results show that the error of the system is about 0.2 mm,which is caused by the error of the AACMM,the sensor error and the calibration error.By measuring a complicated part,the proposed system is proved to be flexible and facilitate,with the ability to measure a part expediently from any necessary direction.Furthermore,the proposed calibration method can also be used for robot hand-eye relationship calibration. 展开更多
关键词 Reverse engineering laser line sensors Articulated arm coordinate measuring machines Conjugate pairs
在线阅读 下载PDF
Design and Research of Active Heave Compensation System Based on Laser Ranging Sensor 被引量:3
12
作者 Chongyang Han 《World Journal of Engineering and Technology》 2020年第1期13-18,共6页
Marine resource exploitation and marine cargo transportation were increasingly frequent. Due to the impact of the marine environment, ships or platforms were affected. In this paper, a servo electric cylinder was used... Marine resource exploitation and marine cargo transportation were increasingly frequent. Due to the impact of the marine environment, ships or platforms were affected. In this paper, a servo electric cylinder was used as a wave compensation actuator to design a wave compensation system. The laser sensor was used to measure the displacement in the direction of the heave platform, and the obtained displacement was applied to the wave compensation in the heave direction to verify the feasibility of the compensation system. 展开更多
关键词 WAVE COMPENSATION laser RANGING sensor HEAVE Stability PLATFORM
在线阅读 下载PDF
Influences of semiconductor laser on fibre-optic distributed disturbance sensor based on Mach-Zehnder interferometer 被引量:2
13
作者 梁生 张春熹 +4 位作者 蔺博 林文台 李勤 钟翔 李立京 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第12期339-346,共8页
This paper investigates the influences of a semiconductor laser with narrow linewidth on a fibre-optic distributed disturbance sensor based on Mach-Zehnder interferometer. It establishes an effective numerical model t... This paper investigates the influences of a semiconductor laser with narrow linewidth on a fibre-optic distributed disturbance sensor based on Mach-Zehnder interferometer. It establishes an effective numerical model to describe the noises and linewidth of a semiconductor laser, taking into account their correlations. Simulation shows that frequency noise has great influences on location errors and their relationship is numerically investigated. Accordingly, there is need to determine the linewidth of the laser less than a threshold and obtain the least location errors. Furthermore, experiments are performed by a sensor prototype using three semiconductor lasers with different linewidths, respectively, with polarization maintaining optical fibres and couplers to eliminate the polarization induced noises and fading. The agreement of simulation with experimental results means that the proposed numerical model can make a comprehensive description of the noise behaviour of a semiconductor laser. The conclusion is useful for choosing a laser source for fibre-optic distributed disturbance sensor to achieve optimized location accuracy. What is more, the proposed numerical model can be widely used for analysing influences of semiconductor lasers on other sensing, communication and optical signal processing systems. 展开更多
关键词 fibre-optic distributed sensor semiconductor laser narrow linewidth laser fibre-optic interferometric sensor
原文传递
Compact fiber-optic diode-laser sensor system for wide-dynamic-range relative humidity measurement
14
作者 SUN Ke, XIE Liang JU Yu WU XuMing HOU Jie HAN Wei WANG Xin MAN JiangWei LIU Yu YUAN HaiQing LUO ZhenAo XIONG Shang ZHU NingHua 《Chinese Science Bulletin》 SCIE EI CAS 2011年第32期3486-3492,共7页
A compact fiber-optic diode-laser sensor system for measuring relative humidity is studied. In such a system, a distributed feedback laser lasing near 1877 nm is used as light source while a high-precision Pt resistan... A compact fiber-optic diode-laser sensor system for measuring relative humidity is studied. In such a system, a distributed feedback laser lasing near 1877 nm is used as light source while a high-precision Pt resistance as temperature sensor, an accuracy of 0.1% relative-humidity can be achieved. The laser sensor system is able to lock to the absorption peak and calculate the density of water vapor without any additional reference measurements. Using programs built in to the microcontroller unit, the laser system can switch functions between direct measurement at high density and second-harmonic detection at low density. The system can switch between the two modes automatically and work in a wide dynamic range. 展开更多
关键词 湿度测量系统 激光二极管 宽动态范围 光纤传感器 紧凑型 铂电阻温度传感器 传感器系统 相对湿度
在线阅读 下载PDF
Laser self-mixing interference fibre sensor
15
作者 朱钧 赵燕 金国藩 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第8期2979-2983,共5页
Fibre sensors exhibit a number of advantages over other sensors such as high sensitivity, electric insulation, corrosion resistance, interference rejection and so on. And laser self-mixing interference can accurately ... Fibre sensors exhibit a number of advantages over other sensors such as high sensitivity, electric insulation, corrosion resistance, interference rejection and so on. And laser self-mixing interference can accurately detect the phase difference of feedback light. In this paper, a novel laser self-mixing interference fibre sensor that combines the advantages of fibre sensors with those of laser self-mixing interference is presented. Experimental configurations are set up to study the relationship between laser power output and phase of laser feedback light when the fibre trembles or when the fibre is stretched or pressed. The theoretical analysis of pressure sensors based on laser self-mixing interference is indicated to accord with the experimental results. 展开更多
关键词 laser self-mixing interference fibre sensor
原文传递
盐穴储气库井场天然气泄漏监测及点位布设优化方法研究 被引量:2
16
作者 陈锋 胡浩 +3 位作者 陈加松 张宏 廖友强 邹先坚 《安全与环境学报》 北大核心 2025年第3期1112-1124,共13页
现有可燃性气体检测传感器具有精度低、点位多、影响因素多且稳定性差等问题。针对盐穴储气库井场结构特征,提出了一种井场天然气微泄漏高精度监测及点位布设优化方法。首先,通过调研不同可燃性气体检测技术性能,采用了点射式激光甲烷... 现有可燃性气体检测传感器具有精度低、点位多、影响因素多且稳定性差等问题。针对盐穴储气库井场结构特征,提出了一种井场天然气微泄漏高精度监测及点位布设优化方法。首先,通过调研不同可燃性气体检测技术性能,采用了点射式激光甲烷探测仪对井场区域进行高精度实时监测。然后,建立不同监测点位泄漏气体成功监测的概率预测模型。基于泄漏仿真模型,研究了不同内外界如风向、风速、泄漏点、泄漏速率等条件下泄漏气体在盐穴储气库井场中的扩散规律。最后,以经济性、监测概率为约束条件,形成了井场微泄漏高精度监测及点位布设优选方法。通过建立软件监测平台,对井场微泄漏进行实时监测与精确预警。结果表明,井口和阀组中心连线的布设方案最优,气体微泄漏的成功监测概率达到75%。该方法实现了盐穴储气库井场微泄漏的实时监测和有效预警,有效降低了储气库密封性失效后产生泄漏事件的风险,保障了盐穴储气库的长期安全监测与高效运营。 展开更多
关键词 安全工程 盐穴储气库 激光传感器 泄漏监测 点位布设优化
原文传递
Laser Deposition of Tetrasulfonated Phthalocyanine Layers for Gas Sensors
17
作者 Premysl Fitl Martin Vrnata +4 位作者 Dusan Kopecky Jan Vlcek Jitka Skodova Jaroslav Hofmann Vladimir Myslik 《Advances in Materials Physics and Chemistry》 2012年第4期84-88,共5页
Thin layers of nickel and copper tetrasulfonated phthalocyanines (NiPcTS and CuPcTS) were prepared by Matrix Assisted Pulsed Laser Evaporation method. The depositions were carried out with KrF excimer laser (energy de... Thin layers of nickel and copper tetrasulfonated phthalocyanines (NiPcTS and CuPcTS) were prepared by Matrix Assisted Pulsed Laser Evaporation method. The depositions were carried out with KrF excimer laser (energy density of laser radiation EL = 0.1 to 0.5 J.cm-2) from dimethylsulfoxide matrix. For both materials the ablation threshold EL-th was determined. The following properties of deposited layers were characterized: a) chemical composition (FTIR spectra);b) morphology (SEM and AFM portraits);c) impedance of gas sensors based on NiPcTS and CuPcTS layers in the presence of two analytes - hydrogen and ozone. The prepared sensors exhibit response to 1000 ppm of hydrogen and 100 ppb of ozone even at laboratory temperature. 展开更多
关键词 Matrix Assisted PULSED laser EVAPORATION SUBSTITUTED Phthalocyanines Gas sensors IMPEDANCE Measurement
在线阅读 下载PDF
面向串并联镜像加工装备的线激光安装位姿高精度标定方法
18
作者 刘海波 李文杰 +5 位作者 丁悦 王鹏飞 梁润 薄其乐 谢福贵 肖世宏 《航空制造技术》 北大核心 2025年第11期14-20,共7页
针对现有串并联机床线激光传感器测量位姿准确标定难题,提出一种适用于串并联机床的线激光安装位姿标定方法。基于标准球特性,求取球心坐标后利用标准球球心不变性建立等式,提出求取旋转矩阵的目标函数;通过扫描标准球表面,获取其点云... 针对现有串并联机床线激光传感器测量位姿准确标定难题,提出一种适用于串并联机床的线激光安装位姿标定方法。基于标准球特性,求取球心坐标后利用标准球球心不变性建立等式,提出求取旋转矩阵的目标函数;通过扫描标准球表面,获取其点云数据并拟合出球心,与球心坐标真值比较并建立平移矩阵的求取模型。与传统手眼标定方法相比,所提方法沿X、Y、Z 3个方向的标定误差分别降低了88.9%、83.6%、82.1%。所提方法无须改变串并联机构的姿态,有效避免了串并联机床定位误差对测量位姿标定的影响,提高了标定精度。 展开更多
关键词 串并联机床 标准球 线激光传感器 位姿标定 测量加工一体化
在线阅读 下载PDF
多线激光传感器尺寸测量的角度安装误差研究
19
作者 郑艳萍 张榕花 张瑞 《机械设计与制造》 北大核心 2025年第4期46-50,59,共6页
多个线激光传感器组合测量被广泛应用于工业现场的产品几何尺寸检测过程中,以梯形钢丝为研究对象,提出了一种基于多个线激光传感器尺寸测量系统的角度误差补偿方法。利用坐标系投影原理和空间几何关系,分析了由线激光传感器的安装误差... 多个线激光传感器组合测量被广泛应用于工业现场的产品几何尺寸检测过程中,以梯形钢丝为研究对象,提出了一种基于多个线激光传感器尺寸测量系统的角度误差补偿方法。利用坐标系投影原理和空间几何关系,分析了由线激光传感器的安装误差导致的坐标轴夹角α、β与工件尺寸测量坐标值x、y之间的数学关系,建立了基于α、β的坐标值误差补偿模型。利用标准件尺寸值对传感器安装角度误差进行计算,同时完成传感器的标定。通过仿真实验验证了该方法的实用性,并对测量精度、标定精度对α、β计算的影响进行分析,为梯形钢丝最佳的测量系统方案设计打下了基础。 展开更多
关键词 角度安装误差 线激光传感器 梯形钢丝尺寸测量 误差补偿
在线阅读 下载PDF
32×32元硅盖革APD探测器的凝视型激光3维成像 被引量:1
20
作者 王江 王鸥 +5 位作者 陈蔚 袁利 柯尊贵 郝昕 孔繁林 姜鹏 《激光技术》 北大核心 2025年第3期463-468,共6页
为了实现对特定目标区域的高精度探测,采用了凝视型激光3维成像技术,基于自研32×32元硅盖革模式激光焦平面探测器,搭建了一套1064 nm激光3维成像实验系统。探测器组件采用带有温度采样与控制模块的斯特林制冷型封装技术,实现了在... 为了实现对特定目标区域的高精度探测,采用了凝视型激光3维成像技术,基于自研32×32元硅盖革模式激光焦平面探测器,搭建了一套1064 nm激光3维成像实验系统。探测器组件采用带有温度采样与控制模块的斯特林制冷型封装技术,实现了在深低温环境下的高控温精度、高稳定性运行;成像系统通过发射脉冲激光点阵照射目标区域,并利用上述探测器捕获激光回波信号;经距离门噪声过滤和3维点云数据预处理后,取得了200 m处目标的3维距离图像以及670 m处目标的2维强度图像。结果表明,该激光3维成像系统具有30 cm的距离分辨率,可精确展现目标的几何细节。该研究为硅盖革模式激光焦平面探测器凝视3维成像技术的实际工程应用提供了参考。 展开更多
关键词 传感器技术 凝视型激光3维成像 雪崩光电二极管 盖革模式
在线阅读 下载PDF
上一页 1 2 110 下一页 到第