Among various architectures of polymers,end-group-free rings have attracted growing interests due to their distinct physicochemical performances over the linear counterparts which are exemplified by reduced hydrodynam...Among various architectures of polymers,end-group-free rings have attracted growing interests due to their distinct physicochemical performances over the linear counterparts which are exemplified by reduced hydrodynamic size and slower degradation.It is key to develop facile methods to large-scale synthesis of polymer rings with tunable compositions and microstructures.Recent progresses in large-scale synthesis of polymer rings against single-chain dynamic nanoparticles,and the example applications in synchronous enhancing toughness and strength of polymer nanocomposites are summarized.Once there is the breakthrough in rational design and effective large-scale synthesis of polymer rings and their functional derivatives,a family of cyclic functional hybrids would be available,thus providing a new paradigm in developing polymer science and engineering.展开更多
LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as ...LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as odometry estimation and 3D reconstruction.Fusing the information from these two sensors can significantly increase the robustness and accuracy of these perception tasks.The extrinsic calibration between cameras and LiDAR is a fundamental prerequisite for multimodal systems.Recently,extensive studies have been conducted on the calibration of extrinsic parameters.Although several calibration methods facilitate sensor fusion,a comprehensive summary for researchers and,especially,non-expert users is lacking.Thus,we present an overview of extrinsic calibration and discuss diverse calibration methods from the perspective of calibration system design.Based on the calibration information sources,this study classifies these methods as target-based or targetless.For each type of calibration method,further classification was performed according to the diverse types of features or constraints used in the calibration process,and their detailed implementations and key characteristics were introduced.Thereafter,calibration-accuracy evaluation methods are presented.Finally,we comprehensively compare the advantages and disadvantages of each calibration method and suggest directions for practical applications and future research.展开更多
The two-dimensional grating serves as a critical component in plane grating interferometers for achieving high-precision multidimensional displacement measurements.The calibration of grating groove density and orthogo...The two-dimensional grating serves as a critical component in plane grating interferometers for achieving high-precision multidimensional displacement measurements.The calibration of grating groove density and orthogonality error of grating grooves not only improves the positioning accuracy of grating interferometers but also provides essential feedback for optimizing two-dimensional grating fabrication.This study proposes a method for simultaneous calibration of these parameters using orthogonal heterodyne laser interferometry.A two-dimensional grating interferometer is built with the grating to be measured,and a biaxial laser interferometer provides a displacement reference for it.The phase mapping relationship between grating interference and laser interference is established.The interference phase information obtained by any two displacements can simultaneously solve the above three parameters and obtain the grating installation error.The feasibility of the proposed method is verified by using a 1200 gr/mm two-dimensional grating.The standard deviation of the grating groove density in the X and Y directions is 0.012 gr/mm and 0.014 gr/mm,respectively.The standard deviation of the orthogonality error of grating grooves is 0.004°,and the standard deviation of the installation error is 0.002°.Compared with the atomic force microscope method,the consistency of the grating groove density in the X and Y directions is better than 0.03 gr/mm and 0.06 gr/mm,and the orthogonality error of grating grooves is better than 0.008°.The experimental results show that the proposed method can be simply and efficiently applied to the calibration of the grating line parameters of the two-dimensional grating.展开更多
This study investigates the reduction in polarization measurement accuracy caused by varying in-cident angles in a liquid crystal variable retarder(LCVR).The phase delay characteristics of the LCVR were examined,with ...This study investigates the reduction in polarization measurement accuracy caused by varying in-cident angles in a liquid crystal variable retarder(LCVR).The phase delay characteristics of the LCVR were examined,with particular emphasis on the influence of different two-dimensional incident angles on phase delay behavior.Building upon the calibration of phase delay under normal incidence,a phase delay calibra-tion model was developed to account for variations in incident angle and driving voltage.A mathematical re-lationship was established between phase delay and the azimuth angle(α)and pitch angle(β).Experimental validation was conducted under three conditions:α=20°,β=0°;α=0°,β=20°;and an arbitrary angle whereα=5°,β=15°.The results demonstrated that the maximum average deviation between theoretical pre-dictions and experimental measurements did not exceed 0.059 rad.The proposed calibration method proved to be both accurate and practical.This approach offers robust support for LCVR parameter calibration and performance optimization in optical systems,particularly in polarization imaging applications.展开更多
The segmented solar telescope described in this study employs a simultaneous dual-wavelength measurement technique to achieve co-phase alignment.To meet the measurement requirements of a 20μm range,5 nm root mean squ...The segmented solar telescope described in this study employs a simultaneous dual-wavelength measurement technique to achieve co-phase alignment.To meet the measurement requirements of a 20μm range,5 nm root mean square precision,and edge jump rates of<10^(−6),this study focused on calibrating the dual-wavelength measurement system for the segmented-mirror solar telescope.Analysis of the relative error in the measurement system revealed that assembly-induced errors such as defocus,translation,scaling,and rotation markedly degrade measurement accuracy.To address these issues,we propose a defocus error compensation algorithm,based on the light intensity distribution of the point spread function(PSF)and an affine transformation model,to calibrate spatial pose deviations across the two measurement channels.A dual-wavelength measurement system was implemented on a segmented-mirror experimental platform for calibration.Experimental results demonstrated that the mean relative error decreased from−0.6423 to−0.0345 nm after calibration,reflecting improved reliability and stability of the co-phase measurements.展开更多
Large-scale complex systems are integral to the functioning of various organizations within the national economy.Despite their significance,the lengthy construction cycles and the involvement of multiple entities ofte...Large-scale complex systems are integral to the functioning of various organizations within the national economy.Despite their significance,the lengthy construction cycles and the involvement of multiple entities often result in the deprioritization of standardized management practices,as they do not yield immediate benefits.The implementation of such systems typically encompasses the integrated phases of "development,construction,utiliz ation,and operation and maintenance".To enhance the overall delivery quality of these systems,it is imperative to dismantle the management barriers among these phases and adopt a holistic approach to standardized management.This paper takes a specific system project as a research object to identify common challenges,and proposes improvement strategies in the implementation of standar dized management.Empirical results indicate a substantial reduction in the system s full-lifecycle costs.展开更多
In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorit...In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorithm under communication constraints to achieve accurate system states of the interested system.An output-based event-triggered scheme is first employed to alleviate transmission burden.Accounting for the limited-communication-induced measurement bias,a novel bias calibration algorithm following the Kalman filtering line is developed to restrain the effect of the measurement bias on system estimation,thereby achieving accurate system state estimates.Subsequently,the Field Programmable Gate Array(FPGA)implementation of the proposed algorithm is also realized with the hope of providing fast bias calibration in practical scenarios.A simulation about a numerical example and a practical example(for gyroscope’s angular velocity bias calibration)on MATLAB is provided to demonstrate the feasibility and effectiveness of the proposed algorithm.展开更多
Summer rainfall in the Yangtze River basin(YRB)is favored by two key factors in the lower troposphere:the tropical anticyclonic anomaly over the western North Pacific and the extratropical northeasterly anomalies to t...Summer rainfall in the Yangtze River basin(YRB)is favored by two key factors in the lower troposphere:the tropical anticyclonic anomaly over the western North Pacific and the extratropical northeasterly anomalies to the north of the YRB.This study,however,found that approximately 46%of heavy rainfall events in the YRB occur when only one factor appears and the other is opposite signed.Accordingly,these heavy rainfall events can be categorized into two types:the extratropical northeasterly anomalies but tropical cyclonic anomaly(first unconventional type),and the tropical anticyclonic anomaly but extratropical southwesterly anomalies(second unconventional type).Anomalous water vapor convergence and upward motion exists for both types,but through different mechanisms.For the first type,the moisture convergence and upward motion are induced by a cyclonic anomaly over the YRB,which appears in the mid and lower troposphere and originates from the upstream region.For the second type,a mid-tropospheric cyclonic anomaly over Lake Baikal extends southward and results in southwesterly anomalies over the YRB,in conjunction with the tropical anticyclonic anomaly.The southwesterly anomalies transport water vapor to the YRB and lead to upward motion through warm advection.This study emphasizes the role of mid-tropospheric circulations in inducing heavy rainfall in the YRB.展开更多
With the widespread adoption of digital equipment in intelligent substations,testing digital signals in power systems has become an important role for relay protection test equipment.Testing and calibrating digital si...With the widespread adoption of digital equipment in intelligent substations,testing digital signals in power systems has become an important role for relay protection test equipment.Testing and calibrating digital signals require high accuracy.However,existing methods have low precision,cannot be calibrated at full range for all indexes,and have complex configuration,making them unsuitable for routine calibration work.To solve the above problems,a novel calibration method is designed and implemented using field programmable gate array(FPGA)to achieve accurate input and output time control.Accurate calibration relies on multiple forms of traceability including theoretical value traceability based on waveform comparison,time scale value traceability based on accurate time stamps,and algorithm traceability based on typical algorithms.Compared with other existing methods,the proposed approach reduces the mean absolute error of action time and time measurement by 92.88%,effectively addressing a key industry challenge and offering a valuable reference for further research,application,and standardization.展开更多
We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-...We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.展开更多
This study develops an event-triggered control strategy utilizing the fully actuated system approach for nonlinear interconnected large-scale systems containing actuator failures.First,to reduce the complexity of the ...This study develops an event-triggered control strategy utilizing the fully actuated system approach for nonlinear interconnected large-scale systems containing actuator failures.First,to reduce the complexity of the design process,we transform the studied system into the form of a fully actuated system through a state transformation.Then,to address the unknown nonlinear functions and actuator fault parameters,we employ neural networks and adaptive estimation techniques,respectively.Moreover,to reduce the control cost and improve the control efficiency,we introduce event-triggered inputs into the control strategy.It is proved by the Lyapunov stability analysis that all signals of the closed-loop system are bounded and the output of system eventually converge to a bounded region.The efficacy of the control approach is ultimately demonstrated via the simulation of an actual machine feeding system.展开更多
Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properti...Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properties of materials under extreme high-pressure and hightemperature conditions.A prerequisite for achieving reproducible property measurements is the determination and control of pressure within experimental setups.However,the lack of precise pressure calibration in LVPs hinders the broader application of such devices in ultrahigh-pressure studies.This study employs a suite of standard phase transition-based pressure markers—comprising metallic conductors,semiconductors,and minerals—through both in situ and ex situ identification approaches,to establish pressure calibration curves ranging from 0.4 to>30 GPa for various types of LVP installed at the Center for High Pressure Science and Technology Advanced Research(HPSTAR),Beijing,including piston–cylinder,cubic,and multi-anvil presses.The results provide a unified and traceable pressure reference for highpressure experiments conducted at HPSTAR,while also offering technical guidance and calibration standards for other researchers utilizing similar LVP systems,thereby enabling more consistent comparison between different laboratories.This work facilitates the advancement of LVP research toward broader applications in higher-pressure regimes.展开更多
1.Introduction Climate change mitigation pathways aimed at limiting global anthropogenic carbon dioxide(CO_(2))emissions while striving to constrain the global temperature increase to below 2℃—as outlined by the Int...1.Introduction Climate change mitigation pathways aimed at limiting global anthropogenic carbon dioxide(CO_(2))emissions while striving to constrain the global temperature increase to below 2℃—as outlined by the Intergovernmental Panel on Climate Change(IPCC)—consistently predict the widespread implementation of CO_(2)geological storage on a global scale.展开更多
The recent upsurge in metro construction emphasizes the necessity of understanding the mechanical performance of metro shield tunnel subjected to the influence of ground fissures.In this study,a largescale experiment,...The recent upsurge in metro construction emphasizes the necessity of understanding the mechanical performance of metro shield tunnel subjected to the influence of ground fissures.In this study,a largescale experiment,in combination with numerical simulation,was conducted to investigate the influence of ground fissures on a metro shield tunnel.The results indicate that the lining contact pressure at the vault increases in the hanging wall while decreases in the footwall,resulting in a two-dimensional stress state of vertical shear and axial tension-compression,and simultaneous vertical dislocation and axial tilt for the segments around the ground fissure.In addition,the damage to curved bolts includes tensile yield,flexural yield,and shear twist,leading to obvious concrete lining damage,particularly at the vault,arch bottom,and hance,indicating that the joints in these positions are weak areas.The shield tunnel orthogonal to the ground fissure ultimately experiences shear failure,suggesting that the maximum actual dislocation of ground fissure that the structure can withstand is approximately 20 cm,and five segment rings in the hanging wall and six segment rings in the footwall also need to be reinforced.This study could provide a reference for metro design in ground fissure sites.展开更多
Defining an ERBB2(HER2/neu)gene amplification status is critical to guiding human epidermal growth factor receptor 2(HER2)-targeted therapy in breast cancer.Up to 40%of breast cancer patients are reported as having an...Defining an ERBB2(HER2/neu)gene amplification status is critical to guiding human epidermal growth factor receptor 2(HER2)-targeted therapy in breast cancer.Up to 40%of breast cancer patients are reported as having an immunohistochemistry(IHC)of HER22+and requiring additional testing using fluorescence in situ hybridization to confirm the results.This paper aims to establish an automatically weighted calibration deep learning(AWCDL)algorithm to predict ERBB2 amplification based on IHC images.In this study,we applied IHC HER22+images from 1,073 breast cancer patients at three cancer centers in China and extracted 376,099 tiles.Among these,269,664 tiles were used for internal and external validation.The designed AWCDL consists of two steps.In Step 1,the internal validation achieved an accuracy of 89%,with a specificity of 0.89 and a sensitivity of 0.89.The external validation in the two other centers showed an average accuracy of 85%,with a specificity of 0.86 and a sensitivity of 0.82.In Step 2,the model achieved higher accuracy for the slides predicted as negative in Step 1 by automatically calibrating the weight.Collectively,these results suggest that this AWCDL model has successfully proved useful as an alternative method to fluorescence in situ hybridization for assessing the ERBB2 amplification status in breast cancer.展开更多
Based on the analysis of typical lacustrine shale oil zones in China and their geological characteristics,this study elucidates the fundamental differences between the enrichment patterns of shale oil sweet spots and ...Based on the analysis of typical lacustrine shale oil zones in China and their geological characteristics,this study elucidates the fundamental differences between the enrichment patterns of shale oil sweet spots and conventional oil and gas.The key parameters and evaluation methods for assessing the large-scale production potential of lacustrine shale oil are proposed.The results show that shale oil is a petroleum resource that exists in organic-rich shale formations,in other words,it is preserved in its source bed,following a different process of generation-accumulation-enrichment from conventional oil and gas.Thus,the concept of“reservoir”seems to be inapplicable to shale oil.In China,lacustrine shale oil is distributed widely,but the geological characteristics and sweet spots enrichment patterns of shale oil vary significantly in lacustrine basins where the water environment and the tectonic evolution and diagenetic transformation frameworks are distinct.The core of the evaluation of lacustrine shale oil is“sweet spot volume”.The key factors for evaluating the large-scale production of continental shale oil are the oil storage capacity,oil-bearing capacity and oil producing capacity.The key parameters for evaluating these capacities are total porosity,oil content,and free oil content,respectively.It is recommended to determine the total porosity of shale by combining helium porosity measurement with nuclear magnetic resonance(NMR)method,the oil content of key layers by using organic solvent extraction,NMR method and high pressure mercury intrusion methods,and the free oil content by using NMR fluid distribution secondary spectral stripping decomposition and logging.The research results contribute supplemental insights on continental shale oil deliverability in China,and provide a scientific basis for the rapid exploration and large-scale production of lacustrine shale oil.展开更多
High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science ...High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.展开更多
The titanium alloy strut serves as a key load-bearing component of aircraft landing gear,typically manufactured via forging.The friction condition has important influence on material flow and cavity filling during the...The titanium alloy strut serves as a key load-bearing component of aircraft landing gear,typically manufactured via forging.The friction condition has important influence on material flow and cavity filling during the forging process.Using the previously optimized shape and initial position of preform,the influence of the friction condition(friction factor m=0.1–0.3)on material flow and cavity filling was studied by numerical method with a shear friction model.A novel filling index was defined to reflect material flow into left and right flashes and zoom in on friction-induced results.The results indicate that the workpiece moves rigidly to the right direction,with the displacement decreasing as m increases.When m<0.18,the underfilling defect will occur in the left side of strut forging,while overflow occurs in the right forging die cavity.By combining the filling index and analyses of material flow and filling status,a reasonable friction factor interval of m=0.21–0.24 can be determined.Within this interval,the cavity filling behavior demonstrates robustness,with friction fluctuations exerting minimal influence.展开更多
Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships betw...Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships between CPT results and the characteristics of such deep,dense sand layers.This study addresses this gap by proposing an empirical relationship to predict the relative density of dense silica sand based on stress level and cone tip resistance.The relationship was developed through CPTs performed in a calibration chamber using dense sand specimens(with relative densities of 74%-91%)subjected to high stresses(under overburden stresses of 0.5-2.0 MPa)and numerical simulations employing the large deformation finite element method.The Arbitrary Lagrangian Eulerian method was used to regularly regenerate the mesh to prevent soil element distortion around the cone tip.Additionally,the modified Mohr-Coulomb model was integrated to capture the stress-strain behavior of dense silica sand under high stresses.A reasonable agreement was achieved between the numerical and experimental penetration profiles,which verifies the reliability of the numerical model.A sufficient number of parametric analyses were carried out,and then an empirical equation was proposed to establish the relationship between the relative density of dense sand,stress level and cone resistance.The empirical equation provides predictions with acceptable accuracy,as the discrepancies between the predicted and measured relative density values fall within±30%.展开更多
Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of th...Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.展开更多
基金Supported by the National Natural Science Foundation of China(Nos.52293472,22473096 and 22471164)。
文摘Among various architectures of polymers,end-group-free rings have attracted growing interests due to their distinct physicochemical performances over the linear counterparts which are exemplified by reduced hydrodynamic size and slower degradation.It is key to develop facile methods to large-scale synthesis of polymer rings with tunable compositions and microstructures.Recent progresses in large-scale synthesis of polymer rings against single-chain dynamic nanoparticles,and the example applications in synchronous enhancing toughness and strength of polymer nanocomposites are summarized.Once there is the breakthrough in rational design and effective large-scale synthesis of polymer rings and their functional derivatives,a family of cyclic functional hybrids would be available,thus providing a new paradigm in developing polymer science and engineering.
基金Supported by Beijing Natural Science Foundation(Grant No.L241012)the National Natural Science Foundation of China(Grant No.62572468).
文摘LiDAR and camera are two of the most common sensors used in the fields of robot perception,autonomous driving,augmented reality,and virtual reality,where these sensors are widely used to perform various tasks such as odometry estimation and 3D reconstruction.Fusing the information from these two sensors can significantly increase the robustness and accuracy of these perception tasks.The extrinsic calibration between cameras and LiDAR is a fundamental prerequisite for multimodal systems.Recently,extensive studies have been conducted on the calibration of extrinsic parameters.Although several calibration methods facilitate sensor fusion,a comprehensive summary for researchers and,especially,non-expert users is lacking.Thus,we present an overview of extrinsic calibration and discuss diverse calibration methods from the perspective of calibration system design.Based on the calibration information sources,this study classifies these methods as target-based or targetless.For each type of calibration method,further classification was performed according to the diverse types of features or constraints used in the calibration process,and their detailed implementations and key characteristics were introduced.Thereafter,calibration-accuracy evaluation methods are presented.Finally,we comprehensively compare the advantages and disadvantages of each calibration method and suggest directions for practical applications and future research.
文摘The two-dimensional grating serves as a critical component in plane grating interferometers for achieving high-precision multidimensional displacement measurements.The calibration of grating groove density and orthogonality error of grating grooves not only improves the positioning accuracy of grating interferometers but also provides essential feedback for optimizing two-dimensional grating fabrication.This study proposes a method for simultaneous calibration of these parameters using orthogonal heterodyne laser interferometry.A two-dimensional grating interferometer is built with the grating to be measured,and a biaxial laser interferometer provides a displacement reference for it.The phase mapping relationship between grating interference and laser interference is established.The interference phase information obtained by any two displacements can simultaneously solve the above three parameters and obtain the grating installation error.The feasibility of the proposed method is verified by using a 1200 gr/mm two-dimensional grating.The standard deviation of the grating groove density in the X and Y directions is 0.012 gr/mm and 0.014 gr/mm,respectively.The standard deviation of the orthogonality error of grating grooves is 0.004°,and the standard deviation of the installation error is 0.002°.Compared with the atomic force microscope method,the consistency of the grating groove density in the X and Y directions is better than 0.03 gr/mm and 0.06 gr/mm,and the orthogonality error of grating grooves is better than 0.008°.The experimental results show that the proposed method can be simply and efficiently applied to the calibration of the grating line parameters of the two-dimensional grating.
文摘This study investigates the reduction in polarization measurement accuracy caused by varying in-cident angles in a liquid crystal variable retarder(LCVR).The phase delay characteristics of the LCVR were examined,with particular emphasis on the influence of different two-dimensional incident angles on phase delay behavior.Building upon the calibration of phase delay under normal incidence,a phase delay calibra-tion model was developed to account for variations in incident angle and driving voltage.A mathematical re-lationship was established between phase delay and the azimuth angle(α)and pitch angle(β).Experimental validation was conducted under three conditions:α=20°,β=0°;α=0°,β=20°;and an arbitrary angle whereα=5°,β=15°.The results demonstrated that the maximum average deviation between theoretical pre-dictions and experimental measurements did not exceed 0.059 rad.The proposed calibration method proved to be both accurate and practical.This approach offers robust support for LCVR parameter calibration and performance optimization in optical systems,particularly in polarization imaging applications.
基金supported by the Yunnan Revitalization Talent Support Program(202305AS350029 and 202305AT350005)Yunnan Revitalization Talent Support Program-Science&Technology Champion Project(202105AB160001)+1 种基金Yunnan Key Laboratory of Solar Physics and Space Science(202205AG070009)Yunnan Provincial Science and Technology Department(202401AU070062).
文摘The segmented solar telescope described in this study employs a simultaneous dual-wavelength measurement technique to achieve co-phase alignment.To meet the measurement requirements of a 20μm range,5 nm root mean square precision,and edge jump rates of<10^(−6),this study focused on calibrating the dual-wavelength measurement system for the segmented-mirror solar telescope.Analysis of the relative error in the measurement system revealed that assembly-induced errors such as defocus,translation,scaling,and rotation markedly degrade measurement accuracy.To address these issues,we propose a defocus error compensation algorithm,based on the light intensity distribution of the point spread function(PSF)and an affine transformation model,to calibrate spatial pose deviations across the two measurement channels.A dual-wavelength measurement system was implemented on a segmented-mirror experimental platform for calibration.Experimental results demonstrated that the mean relative error decreased from−0.6423 to−0.0345 nm after calibration,reflecting improved reliability and stability of the co-phase measurements.
文摘Large-scale complex systems are integral to the functioning of various organizations within the national economy.Despite their significance,the lengthy construction cycles and the involvement of multiple entities often result in the deprioritization of standardized management practices,as they do not yield immediate benefits.The implementation of such systems typically encompasses the integrated phases of "development,construction,utiliz ation,and operation and maintenance".To enhance the overall delivery quality of these systems,it is imperative to dismantle the management barriers among these phases and adopt a holistic approach to standardized management.This paper takes a specific system project as a research object to identify common challenges,and proposes improvement strategies in the implementation of standar dized management.Empirical results indicate a substantial reduction in the system s full-lifecycle costs.
基金support from the National Natural Science Foundation of China(Grant Nos.U2330206,U2230206,62173068)Sichuan Science and Technology Program(Grants Nos.2024NSFSC1483,2024ZYD0156,2023NSFC1962,DQ202412).
文摘In data communication,limited communication resources often lead to measurement bias,which adversely affects subsequent system estimation if not effectively handled.This paper proposes a novel bias calibration algorithm under communication constraints to achieve accurate system states of the interested system.An output-based event-triggered scheme is first employed to alleviate transmission burden.Accounting for the limited-communication-induced measurement bias,a novel bias calibration algorithm following the Kalman filtering line is developed to restrain the effect of the measurement bias on system estimation,thereby achieving accurate system state estimates.Subsequently,the Field Programmable Gate Array(FPGA)implementation of the proposed algorithm is also realized with the hope of providing fast bias calibration in practical scenarios.A simulation about a numerical example and a practical example(for gyroscope’s angular velocity bias calibration)on MATLAB is provided to demonstrate the feasibility and effectiveness of the proposed algorithm.
基金supported by the National Natural Science Foundation of China(Grant No.42275041)the Hainan Province Science and Technology Special Fund(Grant No.SOLZSKY2025006).
文摘Summer rainfall in the Yangtze River basin(YRB)is favored by two key factors in the lower troposphere:the tropical anticyclonic anomaly over the western North Pacific and the extratropical northeasterly anomalies to the north of the YRB.This study,however,found that approximately 46%of heavy rainfall events in the YRB occur when only one factor appears and the other is opposite signed.Accordingly,these heavy rainfall events can be categorized into two types:the extratropical northeasterly anomalies but tropical cyclonic anomaly(first unconventional type),and the tropical anticyclonic anomaly but extratropical southwesterly anomalies(second unconventional type).Anomalous water vapor convergence and upward motion exists for both types,but through different mechanisms.For the first type,the moisture convergence and upward motion are induced by a cyclonic anomaly over the YRB,which appears in the mid and lower troposphere and originates from the upstream region.For the second type,a mid-tropospheric cyclonic anomaly over Lake Baikal extends southward and results in southwesterly anomalies over the YRB,in conjunction with the tropical anticyclonic anomaly.The southwesterly anomalies transport water vapor to the YRB and lead to upward motion through warm advection.This study emphasizes the role of mid-tropospheric circulations in inducing heavy rainfall in the YRB.
基金supported by the Key Technologies R&D Program of Henan Province(No.242102211065)Postgraduate Education Reform and Quality Im-provement Project of Henan Province(No.YJS2025GZZ36).
文摘With the widespread adoption of digital equipment in intelligent substations,testing digital signals in power systems has become an important role for relay protection test equipment.Testing and calibrating digital signals require high accuracy.However,existing methods have low precision,cannot be calibrated at full range for all indexes,and have complex configuration,making them unsuitable for routine calibration work.To solve the above problems,a novel calibration method is designed and implemented using field programmable gate array(FPGA)to achieve accurate input and output time control.Accurate calibration relies on multiple forms of traceability including theoretical value traceability based on waveform comparison,time scale value traceability based on accurate time stamps,and algorithm traceability based on typical algorithms.Compared with other existing methods,the proposed approach reduces the mean absolute error of action time and time measurement by 92.88%,effectively addressing a key industry challenge and offering a valuable reference for further research,application,and standardization.
基金supported by National Key R&D grant from the Ministry of Science and Technology of China(Nos.2021YFA1601600,2023YFA1606200)National Science Foundation of China(Nos.12090062,12105008)the Major State Basic Research Development Program of China.
文摘We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.
基金supported by the Science Center Program of National Natural Science Foundation of China under Grant 62188101the National Natural Science Foundation of China under Grant 62573265.
文摘This study develops an event-triggered control strategy utilizing the fully actuated system approach for nonlinear interconnected large-scale systems containing actuator failures.First,to reduce the complexity of the design process,we transform the studied system into the form of a fully actuated system through a state transformation.Then,to address the unknown nonlinear functions and actuator fault parameters,we employ neural networks and adaptive estimation techniques,respectively.Moreover,to reduce the control cost and improve the control efficiency,we introduce event-triggered inputs into the control strategy.It is proved by the Lyapunov stability analysis that all signals of the closed-loop system are bounded and the output of system eventually converge to a bounded region.The efficacy of the control approach is ultimately demonstrated via the simulation of an actual machine feeding system.
基金supported by the National Science Foundation of China(Grant Nos.U1530402 and U1930401).
文摘Large-volume presses(LVPs)are widely utilized in diverse research fields—including high-pressure physics,chemistry,materials science,and Earth and planetary sciences—to investigate the physical and chemical properties of materials under extreme high-pressure and hightemperature conditions.A prerequisite for achieving reproducible property measurements is the determination and control of pressure within experimental setups.However,the lack of precise pressure calibration in LVPs hinders the broader application of such devices in ultrahigh-pressure studies.This study employs a suite of standard phase transition-based pressure markers—comprising metallic conductors,semiconductors,and minerals—through both in situ and ex situ identification approaches,to establish pressure calibration curves ranging from 0.4 to>30 GPa for various types of LVP installed at the Center for High Pressure Science and Technology Advanced Research(HPSTAR),Beijing,including piston–cylinder,cubic,and multi-anvil presses.The results provide a unified and traceable pressure reference for highpressure experiments conducted at HPSTAR,while also offering technical guidance and calibration standards for other researchers utilizing similar LVP systems,thereby enabling more consistent comparison between different laboratories.This work facilitates the advancement of LVP research toward broader applications in higher-pressure regimes.
基金supported by the National Key Research and Development Program of China(2022YFE0206700)。
文摘1.Introduction Climate change mitigation pathways aimed at limiting global anthropogenic carbon dioxide(CO_(2))emissions while striving to constrain the global temperature increase to below 2℃—as outlined by the Intergovernmental Panel on Climate Change(IPCC)—consistently predict the widespread implementation of CO_(2)geological storage on a global scale.
基金supported by the National Key Research&Development Program of China(Grant No.2023YFC3008404)the Key Laboratory of Earth Fissures Geological Disaster,Ministry of Natural Resources,China(Grant Nos.EFGD20240609 and EFGD20240610).
文摘The recent upsurge in metro construction emphasizes the necessity of understanding the mechanical performance of metro shield tunnel subjected to the influence of ground fissures.In this study,a largescale experiment,in combination with numerical simulation,was conducted to investigate the influence of ground fissures on a metro shield tunnel.The results indicate that the lining contact pressure at the vault increases in the hanging wall while decreases in the footwall,resulting in a two-dimensional stress state of vertical shear and axial tension-compression,and simultaneous vertical dislocation and axial tilt for the segments around the ground fissure.In addition,the damage to curved bolts includes tensile yield,flexural yield,and shear twist,leading to obvious concrete lining damage,particularly at the vault,arch bottom,and hance,indicating that the joints in these positions are weak areas.The shield tunnel orthogonal to the ground fissure ultimately experiences shear failure,suggesting that the maximum actual dislocation of ground fissure that the structure can withstand is approximately 20 cm,and five segment rings in the hanging wall and six segment rings in the footwall also need to be reinforced.This study could provide a reference for metro design in ground fissure sites.
基金supported by the National Natural Science Foundation of China(Grant No.:81672743 and 81974464).
文摘Defining an ERBB2(HER2/neu)gene amplification status is critical to guiding human epidermal growth factor receptor 2(HER2)-targeted therapy in breast cancer.Up to 40%of breast cancer patients are reported as having an immunohistochemistry(IHC)of HER22+and requiring additional testing using fluorescence in situ hybridization to confirm the results.This paper aims to establish an automatically weighted calibration deep learning(AWCDL)algorithm to predict ERBB2 amplification based on IHC images.In this study,we applied IHC HER22+images from 1,073 breast cancer patients at three cancer centers in China and extracted 376,099 tiles.Among these,269,664 tiles were used for internal and external validation.The designed AWCDL consists of two steps.In Step 1,the internal validation achieved an accuracy of 89%,with a specificity of 0.89 and a sensitivity of 0.89.The external validation in the two other centers showed an average accuracy of 85%,with a specificity of 0.86 and a sensitivity of 0.82.In Step 2,the model achieved higher accuracy for the slides predicted as negative in Step 1 by automatically calibrating the weight.Collectively,these results suggest that this AWCDL model has successfully proved useful as an alternative method to fluorescence in situ hybridization for assessing the ERBB2 amplification status in breast cancer.
基金Supported by the National Key R&D Program of China(2024YFE0114000)Science and Technology Project of China National Petroleum Corporation(2024DJ8702).
文摘Based on the analysis of typical lacustrine shale oil zones in China and their geological characteristics,this study elucidates the fundamental differences between the enrichment patterns of shale oil sweet spots and conventional oil and gas.The key parameters and evaluation methods for assessing the large-scale production potential of lacustrine shale oil are proposed.The results show that shale oil is a petroleum resource that exists in organic-rich shale formations,in other words,it is preserved in its source bed,following a different process of generation-accumulation-enrichment from conventional oil and gas.Thus,the concept of“reservoir”seems to be inapplicable to shale oil.In China,lacustrine shale oil is distributed widely,but the geological characteristics and sweet spots enrichment patterns of shale oil vary significantly in lacustrine basins where the water environment and the tectonic evolution and diagenetic transformation frameworks are distinct.The core of the evaluation of lacustrine shale oil is“sweet spot volume”.The key factors for evaluating the large-scale production of continental shale oil are the oil storage capacity,oil-bearing capacity and oil producing capacity.The key parameters for evaluating these capacities are total porosity,oil content,and free oil content,respectively.It is recommended to determine the total porosity of shale by combining helium porosity measurement with nuclear magnetic resonance(NMR)method,the oil content of key layers by using organic solvent extraction,NMR method and high pressure mercury intrusion methods,and the free oil content by using NMR fluid distribution secondary spectral stripping decomposition and logging.The research results contribute supplemental insights on continental shale oil deliverability in China,and provide a scientific basis for the rapid exploration and large-scale production of lacustrine shale oil.
文摘High-precision magnetic field measurements are crucial for understanding Earth’s internal structure,space environment,and dynamic geomagnetic variations.Data from the Fluxgate Magnetometer (FGM) on the Macao Science Satellite-1A (MSS-1A),added to data from other space-based magnetometers,should increase significantly the ability of scientists to observe changes in Earth’s magnetic field over time and space.Additionally,the MSS-1A’s FGM is intended to help identify magnetic disturbances affecting the spacecraft itself.This report focuses on the in-flight calibration of the MSS-1 FGM.A scalar calibration,independent of geomagnetic field models,was performed to correct offsets,sensitivities,and misalignment angles of the FGM.Using seven months of data,we find that the in-flight calibration parameters show good stability.We determined Euler angles describing the rotational relationship between the FGM and the Advanced Stellar Compass (ASC) coordinate system using two approaches:calibration with the CHAOS-7 geomagnetic field model,and simultaneous estimation of Euler angles and Gaussian spherical harmonic coefficients through self-consistent modeling.The accuracy of Euler angles describing the rotation was better than 18 arcsec.The calibrated FGM data exhibit good agreement with the calibrated data of the Vector Field Magnetometer (VFM),which is the primary vector magnetometer of the satellite.These calibration efforts have significantly improved the accuracy of the FGM measurements,which are now providing reliable data for geomagnetic field studies that promise to advance our understanding of the Earth’s magnetic environment.
基金National Natural Science Foundation of China(52375378)National Key Laboratory of Metal Forming Technology and Heavy Equipment(S2308100.W12)Huxiang High-Level Talent Gathering Project of Hunan Province(2021RC5001)。
文摘The titanium alloy strut serves as a key load-bearing component of aircraft landing gear,typically manufactured via forging.The friction condition has important influence on material flow and cavity filling during the forging process.Using the previously optimized shape and initial position of preform,the influence of the friction condition(friction factor m=0.1–0.3)on material flow and cavity filling was studied by numerical method with a shear friction model.A novel filling index was defined to reflect material flow into left and right flashes and zoom in on friction-induced results.The results indicate that the workpiece moves rigidly to the right direction,with the displacement decreasing as m increases.When m<0.18,the underfilling defect will occur in the left side of strut forging,while overflow occurs in the right forging die cavity.By combining the filling index and analyses of material flow and filling status,a reasonable friction factor interval of m=0.21–0.24 can be determined.Within this interval,the cavity filling behavior demonstrates robustness,with friction fluctuations exerting minimal influence.
基金National Natural Science Foundation of China(Nos.42025702,52394251)。
文摘Currently,there is a lack of in-situ or model test results for cone penetration tests(CPTs)conducted in deep,dense sand layers under high overburden stresses,restricting the development of empirical relationships between CPT results and the characteristics of such deep,dense sand layers.This study addresses this gap by proposing an empirical relationship to predict the relative density of dense silica sand based on stress level and cone tip resistance.The relationship was developed through CPTs performed in a calibration chamber using dense sand specimens(with relative densities of 74%-91%)subjected to high stresses(under overburden stresses of 0.5-2.0 MPa)and numerical simulations employing the large deformation finite element method.The Arbitrary Lagrangian Eulerian method was used to regularly regenerate the mesh to prevent soil element distortion around the cone tip.Additionally,the modified Mohr-Coulomb model was integrated to capture the stress-strain behavior of dense silica sand under high stresses.A reasonable agreement was achieved between the numerical and experimental penetration profiles,which verifies the reliability of the numerical model.A sufficient number of parametric analyses were carried out,and then an empirical equation was proposed to establish the relationship between the relative density of dense sand,stress level and cone resistance.The empirical equation provides predictions with acceptable accuracy,as the discrepancies between the predicted and measured relative density values fall within±30%.
基金Support by Sichuan Science and Technology Program[2023YFSY0026,2023YFH0004].
文摘Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.