This work presents a systematic analysis of proton-induced total ionizing dose(TID)effects in 1.2 k V silicon carbide(SiC)power devices with various edge termination structures.Three edge terminations including ring-a...This work presents a systematic analysis of proton-induced total ionizing dose(TID)effects in 1.2 k V silicon carbide(SiC)power devices with various edge termination structures.Three edge terminations including ring-assisted junction termination extension(RA-JTE),multiple floating zone JTE(MFZ-JTE),and field limiting rings(FLR)were fabricated and irradiated with45 Me V protons at fluences ranging from 1×10^(12) to 1×10^(14) cm^(-2).Experimental results,supported by TCAD simulations,show that the RA-JTE structure maintained stable breakdown performance with less than 1%variation due to its effective electric field redistribution by multiple P+rings.In contrast,MFZ-JTE and FLR exhibit breakdown voltage shifts of 6.1%and 15.2%,respectively,under the highest fluence.These results demonstrate the superior radiation tolerance of the RA-JTE structure under TID conditions and provide practical design guidance for radiation-hardened Si C power devices in space and other highradiation environments.展开更多
In this study,the dosimetric characteristics(thickness applicability,preheating time,temperature and humidity dependence,in-batch uniformity,readout reproducibility,dose linearity,self-decay,and electron energy respon...In this study,the dosimetric characteristics(thickness applicability,preheating time,temperature and humidity dependence,in-batch uniformity,readout reproducibility,dose linearity,self-decay,and electron energy response)of engineered polycarbonate films irradiated with an electron beam(0–600 kGy)were investigated using photoluminescence spectroscopy.The results show a linear relationship between photoluminescence intensity and radiation dose when the thickness of the polycarbonate film is 0.3 mm.A higher fluorescence intensity can be obtained by preheating at 60℃ for 180 min before photoluminescence spectrum analysis.As the temperature during spectral testing and the ambient humidity(during and after irradiation)increased,the photoluminescence intensity of the polycarbonate films decreased.The photoluminescence intensity deviation of the polycarbonate films produced within the same batch at 100 kGy is 2.73%.After ten times of repeated excitations and readouts,the coefficients of variation in photoluminescence intensity are less than 8.6%,and the linear correlation coefficient between photoluminescence intensity and irradiation dose is 0.965 in the dose capture range of 20–600 kGy.Within 60 days of irradiation,the photoluminescence intensity of the polycarbonate film decreased to 60%of the initial value.The response of the 0.3 mm polycarbonate films to electron beams with energies exceeding 3.5 MeV does not differ significantly.This comprehensive analysis indicates the potential of polycarbonate films as a high-radiation dose detection material.展开更多
This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was ...This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was carried out within the framework of the Facility Quality Assurance Program with the purpose of to determine the calibration curve and accuracy of the Harwell Amber Perspex 3042 W dosimeters. The irradiations of the dosimeters were made in operational conditions of a Gamma lrradiator at CDTN, an R & D (research and development) institute connected to the CNEN (National Nuclear Energy Commission) (Brazil). The values for estimate of the expanded uncertainties achieved are typical of a routine dosimetry system.展开更多
平均光强分布是自由空间激光通信(Free Space Optical Communication,FSOC)性能分析中的一个重要参数,非零均值不等方差的跟踪误差场景下平均光强分布理论的封闭表达式尚未得出。采用统计平均的方法对非零均值不等方差跟踪误差下的平均...平均光强分布是自由空间激光通信(Free Space Optical Communication,FSOC)性能分析中的一个重要参数,非零均值不等方差的跟踪误差场景下平均光强分布理论的封闭表达式尚未得出。采用统计平均的方法对非零均值不等方差跟踪误差下的平均光强分布进行建模并推导出其理论的封闭表达式,通过蒙特卡洛模拟对所推导的结果进行验证。在非零均值不等方差跟踪误差的影响下,高斯光束的平均光强分布廓线的形状和中心位置均发生变化。此外,采用相同面积的方形接收孔径代替圆形接收孔径,推导出非零均值不等方差跟踪误差下的平均接收功率。该工作能为非零均值不等方差跟踪误差下的自由空间激光通信系统性能分析和链路设计提供理论指导。展开更多
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra...Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.展开更多
基金supported by the IITP(Institute for Information&Communications Technology Planning&Evaluation)under the ITRC(Information Technology Research Center)support program(IITP-2025-RS-2024-00438288)grant funded by the Korea government(MSIT)+1 种基金National Research Council of Science&Technology(NST)grant by the MSIT(Aerospace Semiconductor Strategy Research Project No.GTL25051-000)supported by the IC Design Education Center(IDEC),Korea。
文摘This work presents a systematic analysis of proton-induced total ionizing dose(TID)effects in 1.2 k V silicon carbide(SiC)power devices with various edge termination structures.Three edge terminations including ring-assisted junction termination extension(RA-JTE),multiple floating zone JTE(MFZ-JTE),and field limiting rings(FLR)were fabricated and irradiated with45 Me V protons at fluences ranging from 1×10^(12) to 1×10^(14) cm^(-2).Experimental results,supported by TCAD simulations,show that the RA-JTE structure maintained stable breakdown performance with less than 1%variation due to its effective electric field redistribution by multiple P+rings.In contrast,MFZ-JTE and FLR exhibit breakdown voltage shifts of 6.1%and 15.2%,respectively,under the highest fluence.These results demonstrate the superior radiation tolerance of the RA-JTE structure under TID conditions and provide practical design guidance for radiation-hardened Si C power devices in space and other highradiation environments.
基金supported by the National Natural Science Foundation of China(No.12305385)Key Projects of Scientific Research of the Hunan Provincial Department of Education(22A0310)the Research Startup Project of University of South China(220XQD025).
文摘In this study,the dosimetric characteristics(thickness applicability,preheating time,temperature and humidity dependence,in-batch uniformity,readout reproducibility,dose linearity,self-decay,and electron energy response)of engineered polycarbonate films irradiated with an electron beam(0–600 kGy)were investigated using photoluminescence spectroscopy.The results show a linear relationship between photoluminescence intensity and radiation dose when the thickness of the polycarbonate film is 0.3 mm.A higher fluorescence intensity can be obtained by preheating at 60℃ for 180 min before photoluminescence spectrum analysis.As the temperature during spectral testing and the ambient humidity(during and after irradiation)increased,the photoluminescence intensity of the polycarbonate films decreased.The photoluminescence intensity deviation of the polycarbonate films produced within the same batch at 100 kGy is 2.73%.After ten times of repeated excitations and readouts,the coefficients of variation in photoluminescence intensity are less than 8.6%,and the linear correlation coefficient between photoluminescence intensity and irradiation dose is 0.965 in the dose capture range of 20–600 kGy.Within 60 days of irradiation,the photoluminescence intensity of the polycarbonate film decreased to 60%of the initial value.The response of the 0.3 mm polycarbonate films to electron beams with energies exceeding 3.5 MeV does not differ significantly.This comprehensive analysis indicates the potential of polycarbonate films as a high-radiation dose detection material.
文摘This paper presents results of PMMA (polymethylmethacrylate) dosimeters calibrations that are used as routine dosimeters in CDTN (Nuclear Technology Development Center) Gamma Irradiation Laboratory. The study was carried out within the framework of the Facility Quality Assurance Program with the purpose of to determine the calibration curve and accuracy of the Harwell Amber Perspex 3042 W dosimeters. The irradiations of the dosimeters were made in operational conditions of a Gamma lrradiator at CDTN, an R & D (research and development) institute connected to the CNEN (National Nuclear Energy Commission) (Brazil). The values for estimate of the expanded uncertainties achieved are typical of a routine dosimetry system.
文摘平均光强分布是自由空间激光通信(Free Space Optical Communication,FSOC)性能分析中的一个重要参数,非零均值不等方差的跟踪误差场景下平均光强分布理论的封闭表达式尚未得出。采用统计平均的方法对非零均值不等方差跟踪误差下的平均光强分布进行建模并推导出其理论的封闭表达式,通过蒙特卡洛模拟对所推导的结果进行验证。在非零均值不等方差跟踪误差的影响下,高斯光束的平均光强分布廓线的形状和中心位置均发生变化。此外,采用相同面积的方形接收孔径代替圆形接收孔径,推导出非零均值不等方差跟踪误差下的平均接收功率。该工作能为非零均值不等方差跟踪误差下的自由空间激光通信系统性能分析和链路设计提供理论指导。
文摘Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.