In the microwave 199Hg+ trapped-ion clock, the frequency instability degradation caused by the Dick effect is un- avoidable because of the periodical interrogating field. In this paper, the general expression of the ...In the microwave 199Hg+ trapped-ion clock, the frequency instability degradation caused by the Dick effect is un- avoidable because of the periodical interrogating field. In this paper, the general expression of the sensitivity function g(t) to the frequency fluctuation of the interrogating field with Nπ-pulse (N is odd) is derived. According to the measured phase noise of the 40.5-GHz microwave synthesizer, the Dick-effect limited Allan deviation of our 199Hg+ trapped-ion clock is worked out. The results indicate that the limited Allan deviations are about 1.75 ×10-13/√τ and 3.03 ×10-13/√τ respectively in the linear ion trap and in the two-segment extended linear ion trap under our present experimental parameters.展开更多
The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic...The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock.展开更多
Based on the multiconfiguration Dirac-Hartree-Fock(MCDHF)method,similar models are employed to simultaneously calculate the first-order and second-order Zeeman coefficients as well as the hyperfine interaction constan...Based on the multiconfiguration Dirac-Hartree-Fock(MCDHF)method,similar models are employed to simultaneously calculate the first-order and second-order Zeeman coefficients as well as the hyperfine interaction constants of the related energy levels of ^(27)Al^(+)and its logical ions ^(9)Be^(+)and^(25)Mg^(+)in the^(27)Al^(+)optical clock.With less than 0.34%deviations from experimental values in Zeeman coefficients of^(27)Al^(+),these calculated parameters will be of great help for better evaluation of the systematic uncertainty.We also calculate the isotope shift parameters of the related energy levels,which could extend our knowledge and understanding of nuclear properties of these ions.展开更多
Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scal...Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10^-19 level.By precisely measuring the differential static scalar polarizability∆α0,the uncertainty due to the blackbody radiation(BBR)shift(coefficient)is reduced to the 10^-19 level.With the help of a second-order integrating servo algorithm,the uncertainty due to the servo error is reduced to the 10^-18 level.The total fractional uncertainty of the ^40Ca^+ion optical clock is then improved to 2.2×10^-17,whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations.The state preparation is introduced together with improvements in the pulse sequence,and furthermore,a better signal to noise ratio(SNR)and less dead time are achieved.The clock stability of a single clock is improved to 4.8×10^-15√τ(in seconds).展开更多
In the ^(199)Hg^(+) ion microwave clock,the Zeeman decoherence effect caused by the overlapping of Zeeman sidebands and the radial secular motion sidebands will decrease the contrast of the Ramsey fringe,thus reducing...In the ^(199)Hg^(+) ion microwave clock,the Zeeman decoherence effect caused by the overlapping of Zeeman sidebands and the radial secular motion sidebands will decrease the contrast of the Ramsey fringe,thus reducing the signal-to-noise ratio of the spectra.In this paper,the Zeeman decoherence effect is analyzed theoretically and investigated experimentally.A simplified model is built to describe the Ramsey spectral probability,in which the transverse relaxation time T2 is introduced to characterize the influence of the Zeeman decoherence effect phenomenologically.The experiments were carried out on a linear quadrupole trap ^(199)Hg^(+) ion clock.The results show that the probability model matches well with the experimental data,and the magnetic field value should be more than 150 mGs(1 Gs=10^(-4) T)to avoid the Zeeman decoherence effect.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11074248 and 11474320)
文摘In the microwave 199Hg+ trapped-ion clock, the frequency instability degradation caused by the Dick effect is un- avoidable because of the periodical interrogating field. In this paper, the general expression of the sensitivity function g(t) to the frequency fluctuation of the interrogating field with Nπ-pulse (N is odd) is derived. According to the measured phase noise of the 40.5-GHz microwave synthesizer, the Dick-effect limited Allan deviation of our 199Hg+ trapped-ion clock is worked out. The results indicate that the limited Allan deviations are about 1.75 ×10-13/√τ and 3.03 ×10-13/√τ respectively in the linear ion trap and in the two-segment extended linear ion trap under our present experimental parameters.
基金Supported by the National Basic Research Program of China under Grant No 2012CB821300the National Natural Science Foundation of China under Grant Nos 91336213,11304109,91536116 and 11174095the Program for New Century Excellent Talents by the Ministry of Education under Grant No NCET-11-0176
文摘The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11604385 and 91536106)the Natural Science Foundation of Hunan Province,China(Grant No.2019JJ50743)the Research Project of the National University of Defense Technology(Grant No.ZK17-03-11)。
文摘Based on the multiconfiguration Dirac-Hartree-Fock(MCDHF)method,similar models are employed to simultaneously calculate the first-order and second-order Zeeman coefficients as well as the hyperfine interaction constants of the related energy levels of ^(27)Al^(+)and its logical ions ^(9)Be^(+)and^(25)Mg^(+)in the^(27)Al^(+)optical clock.With less than 0.34%deviations from experimental values in Zeeman coefficients of^(27)Al^(+),these calculated parameters will be of great help for better evaluation of the systematic uncertainty.We also calculate the isotope shift parameters of the related energy levels,which could extend our knowledge and understanding of nuclear properties of these ions.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2017YFA0304401,2018YFA0307500,2017YFA0304404,and 2017YFF0212003)the National Natural Science Foundation of China(Grant Nos.11622434,11774388,11634013,11934014,and 91736310)+2 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB21030100)the CAS Youth Innovation Promotion Association(Grant Nos.Y201963 and 2018364)the Science Fund for Distinguished Young Scholars of Hubei Province,China(Grant No.2017CFA040).
文摘Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10^-19 level.By precisely measuring the differential static scalar polarizability∆α0,the uncertainty due to the blackbody radiation(BBR)shift(coefficient)is reduced to the 10^-19 level.With the help of a second-order integrating servo algorithm,the uncertainty due to the servo error is reduced to the 10^-18 level.The total fractional uncertainty of the ^40Ca^+ion optical clock is then improved to 2.2×10^-17,whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations.The state preparation is introduced together with improvements in the pulse sequence,and furthermore,a better signal to noise ratio(SNR)and less dead time are achieved.The clock stability of a single clock is improved to 4.8×10^-15√τ(in seconds).
基金Project supported by the National Key Research and Development Program of China(Grant No.2022YFB3904002).
文摘In the ^(199)Hg^(+) ion microwave clock,the Zeeman decoherence effect caused by the overlapping of Zeeman sidebands and the radial secular motion sidebands will decrease the contrast of the Ramsey fringe,thus reducing the signal-to-noise ratio of the spectra.In this paper,the Zeeman decoherence effect is analyzed theoretically and investigated experimentally.A simplified model is built to describe the Ramsey spectral probability,in which the transverse relaxation time T2 is introduced to characterize the influence of the Zeeman decoherence effect phenomenologically.The experiments were carried out on a linear quadrupole trap ^(199)Hg^(+) ion clock.The results show that the probability model matches well with the experimental data,and the magnetic field value should be more than 150 mGs(1 Gs=10^(-4) T)to avoid the Zeeman decoherence effect.