The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl...The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.展开更多
In this paper, we show that the invertible operator T, which is a bounded linear functional on a separable Hilbert space H, could factor as T = US, where U is unitary and S belongs to width-two CSL algebra algφ (φ ...In this paper, we show that the invertible operator T, which is a bounded linear functional on a separable Hilbert space H, could factor as T = US, where U is unitary and S belongs to width-two CSL algebra algφ (φ = M∨N) when nest M or N is a countable nest, or S belongs to algφ^-1 when nests M and N are countable nests. For the factorization of nest,we obtain that T factors as T = US where S ∈ DN^-1 and U is unitary as N be a countable nest.展开更多
In this paper, firstly we shall show some equivalent conditions of A 〉 B 〉 0; secondly by using the results of ours we shall show some characterizations of the chaotic order(i.e., logA≥log B) by norm inequalities.
In this paper,we characterize reverse Carleson measures for a class of generalized Fock spaces F^(p)_(φ),with 0<p<∞and withφsatisfying dd^(c)_(φ)■ω0.As an application of these results,we obtain several equ...In this paper,we characterize reverse Carleson measures for a class of generalized Fock spaces F^(p)_(φ),with 0<p<∞and withφsatisfying dd^(c)_(φ)■ω0.As an application of these results,we obtain several equivalent characterizations for invertible Toeplitz operators Tψ,induced by positive bounded symbols φ on F^(2)_(φ).展开更多
In this paper,we give out a further extension of the relations between two famous inequalities(B r 2 A p B r 2) r p+r≥B r and Ap≥(A p 2 B r A p 2) p p+r,which can yield the result of Yamazaki and Yanagida's.
Parallel operation of inverter modules is the solution to increase the reliability,efficiency,and redundancy of inverters in microgrids.Load sharing among inverters in distributed generators(DGs)is a key issue.This st...Parallel operation of inverter modules is the solution to increase the reliability,efficiency,and redundancy of inverters in microgrids.Load sharing among inverters in distributed generators(DGs)is a key issue.This study investigates the feasibility of power-sharing among parallel DGs using a dual control strategy in islanded mode of a microgrid.PQ control and droop control techniques are established to control the microgrid operation.P-f and Q-E droop control is used to attain real and reactive power sharing.The frequency variation caused by load change is an issue in droop control strategy whereas the tracking error of inverter power in PQ control is also a challenge.To address these issues,two DGs are interfaced with two parallel inverters in an islanded AC microgrid.PQ control is investigated for controlling the output real and reactive power of the DGs by assigning their references.The inverter under enhanced droop control implements power reallocation to restore the frequency among the distributed generators with predefined droop characteristics.A dual control strategy is proposed for the AC microgrid under islanded operation without communication link.Simulation studies are carried out using MATLAB/SIMULINK and the results show the validity and effective power-sharing performance of the system while maintaining a stable operation when the microgrid is in islanding mode.展开更多
In this note an alternative proof of the equivalence of Drazin invertibility of operators AB and BA is given. As an application, we will prove that σD(AB) = σD(BA) and σD(A) = σD(A), where σD(M) and ■ denote the...In this note an alternative proof of the equivalence of Drazin invertibility of operators AB and BA is given. As an application, we will prove that σD(AB) = σD(BA) and σD(A) = σD(A), where σD(M) and ■ denote the Drazin spectrum and the Aluthge transform of an operator M ∈ B(H), respectively.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.51977046)Wuxi University Research Start-up Fund for Introduced Talent(2022r021).
文摘The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.
基金Supported by the National Science Foundation of China(90205019)
文摘In this paper, we show that the invertible operator T, which is a bounded linear functional on a separable Hilbert space H, could factor as T = US, where U is unitary and S belongs to width-two CSL algebra algφ (φ = M∨N) when nest M or N is a countable nest, or S belongs to algφ^-1 when nests M and N are countable nests. For the factorization of nest,we obtain that T factors as T = US where S ∈ DN^-1 and U is unitary as N be a countable nest.
基金the Education Foundation of Henan Province(2003110006)
文摘In this paper, firstly we shall show some equivalent conditions of A 〉 B 〉 0; secondly by using the results of ours we shall show some characterizations of the chaotic order(i.e., logA≥log B) by norm inequalities.
基金supported by the NNSF of China(12071155)supported by the NNSF of China(11871170)+1 种基金the open project of Key Laboratory,school of Mathematical Sciences,Chongqing Normal University(CSSXKFKTM202002)supported by the Innovation Research for the Postgraduates of Guangzhou University(2020GDJC-D08)。
文摘In this paper,we characterize reverse Carleson measures for a class of generalized Fock spaces F^(p)_(φ),with 0<p<∞and withφsatisfying dd^(c)_(φ)■ω0.As an application of these results,we obtain several equivalent characterizations for invertible Toeplitz operators Tψ,induced by positive bounded symbols φ on F^(2)_(φ).
基金Supported by the Natural Science Foundation of the Department of Education of Henan Province(2011A110009)
文摘In this paper,we give out a further extension of the relations between two famous inequalities(B r 2 A p B r 2) r p+r≥B r and Ap≥(A p 2 B r A p 2) p p+r,which can yield the result of Yamazaki and Yanagida's.
基金This work was supported in part by the National Natural Science Foundation of China under Grant 51477098National Key R&D Program of China(2016YFB0900504).
文摘Parallel operation of inverter modules is the solution to increase the reliability,efficiency,and redundancy of inverters in microgrids.Load sharing among inverters in distributed generators(DGs)is a key issue.This study investigates the feasibility of power-sharing among parallel DGs using a dual control strategy in islanded mode of a microgrid.PQ control and droop control techniques are established to control the microgrid operation.P-f and Q-E droop control is used to attain real and reactive power sharing.The frequency variation caused by load change is an issue in droop control strategy whereas the tracking error of inverter power in PQ control is also a challenge.To address these issues,two DGs are interfaced with two parallel inverters in an islanded AC microgrid.PQ control is investigated for controlling the output real and reactive power of the DGs by assigning their references.The inverter under enhanced droop control implements power reallocation to restore the frequency among the distributed generators with predefined droop characteristics.A dual control strategy is proposed for the AC microgrid under islanded operation without communication link.Simulation studies are carried out using MATLAB/SIMULINK and the results show the validity and effective power-sharing performance of the system while maintaining a stable operation when the microgrid is in islanding mode.
基金the National Natural Science Foundation of China (No.10571113)
文摘In this note an alternative proof of the equivalence of Drazin invertibility of operators AB and BA is given. As an application, we will prove that σD(AB) = σD(BA) and σD(A) = σD(A), where σD(M) and ■ denote the Drazin spectrum and the Aluthge transform of an operator M ∈ B(H), respectively.