期刊文献+
共找到8,010篇文章
< 1 2 250 >
每页显示 20 50 100
Coordinated control between a grid forming inverter and grid following inverters suppling power in a standalone microgrid 被引量:1
1
作者 Junichi Arai Yasuhiro Taguchi 《Global Energy Interconnection》 EI CAS CSCD 2022年第3期259-265,共7页
Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However... Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However,sub-networks,such as a microgrids containing inverter power sources,may be disconnected from the utility network and operated in a standalone mode during extended blackouts.This study focuses on a standalone microgrid supplied by inverter power sources without a synchronous generator and proposes a new microgrid inverter control.In this inverter control,a single grid forming inverter is operated as a master power source to determine frequency and voltage,and other inverters,called grid following inverters,are operated as subordinate power sources with active and reactive power control.The necessary functions in the energy management system are examined,and the coordinated operation of all inverters in the microgrid is demonstrated via simulation. 展开更多
关键词 inverter control MICROGRID Standalone operation Energy management system Grid forming inverter Grid following inverter
在线阅读 下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:3
2
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
在线阅读 下载PDF
A New Predictive Direct Power Control Solution for Three-phase Grid-Connected Inverters 被引量:2
3
作者 Ding Weizhong Pan Zaiping 《电工技术学报》 EI CSCD 北大核心 2015年第14期67-74,共8页
This paper proposes a new Predictive Direct Power Control(P-DPC) solution for three-phase grid-connected inverters, which combines direct power control strategy with the predictive control strategy and space vector pu... This paper proposes a new Predictive Direct Power Control(P-DPC) solution for three-phase grid-connected inverters, which combines direct power control strategy with the predictive control strategy and space vector pulse width modulation(SVPWM), obtaining both high transient performance and a constant switching frequency. This control solution can achieve decoupling control for active and reactive power and an adjustable power factor. Meanwhile, the grid-connected current can approximately be sinusoidal. The feasibility and advantages of the control strategy are verified by the simulation and experiment compared with another existing P-DPC. 展开更多
关键词 电工技术 电工安全 电工实验 电工制图
在线阅读 下载PDF
Electric Vehicle IM Controller Based on Voltage-Fed Inverter 被引量:2
4
作者 宋建国 张承宁 +1 位作者 袁学 谭建 《Journal of Beijing Institute of Technology》 EI CAS 2004年第4期441-444,共4页
A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands ... A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands the capacity of controller. The relationship between stator's voltage and that of current under rotor's flux-oriented-coordinates is first introduced, and then the structure of vector control is analyzed, in which voltage compensation is inducted as the core feedback procedure. Experiments prove that, together with a facility for realization, a smooth transition, a prompt torque response and small concussion are gained. Extensive research conducted by varying parameters that result in practical ripple is proposed in conclusion. 展开更多
关键词 voltage-fed inverter decouple vector control inteligent power module(IPM)
在线阅读 下载PDF
Digital control of pulsed gas metal arc welding inverter using TMS320LF2407A 被引量:1
5
作者 吴开源 黄石生 +1 位作者 李星林 吴水锋 《China Welding》 EI CAS 2008年第1期75-80,共6页
A digital control of pulsed gas metal arc welding inverter was proposed. A control system consisting of analogue parts was replaced with a new digital control implemented in a TMS320LF2407A DSP chip. The design and co... A digital control of pulsed gas metal arc welding inverter was proposed. A control system consisting of analogue parts was replaced with a new digital control implemented in a TMS320LF2407A DSP chip. The design and constructional features of the whole digital control were presented. The resources of the DSP chip were efficiently utilized and the circuits are very concise, which can enhance the stability and reliability of welding inverter. Experimental results demonstrate that the developed digital control has the ability to accomplish the excellent pulsed gas metal arc welding process and the merits of the developed digital control are stable welding process, little spatter and perfect weld appearance. 展开更多
关键词 pulsed gas metal arc welding inverter digital control digital signal processor TMS320LF2407A
在线阅读 下载PDF
A Control Strategy for Grid-connected Inverters With LCL Filters 被引量:37
6
作者 HU Xuefeng WEI Zheng +2 位作者 CHEN Yihan GONG Chunying ZHANG Jiayan 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0018-I0018,194,共1页
把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用... 把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用直接入网电流控制时,LCL滤波器接口的并网逆变器系统存在稳定性问题。该文采用电网侧电感电流和逆变侧电感电流双闭环控制策略对并网电流进行直接控制,电网侧电感电流作为外环更容易抑制并网电流的谐波因素,且可以直接控制入网电流的单位功率因数,采用逆变器侧电感电流作为内环可以增加系统阻尼,从而可抑制系统振荡,增加系统稳定性。对该方案进行系统建模,并深入分析了滤波器参数、控制器参数及系统稳定性之间的精确量化关系。仿真和实验结果表明,该控制策略既可有效抑制入网电流谐振和实现进网电流的高功率因数运行,同时又具有良好的稳态和动态性能。 展开更多
关键词 并网逆变器 控制策略 滤波器 供电网络 电流反馈 开关频率 三阶系统 谐波失真
原文传递
Randomized Integral Gain of Pi Current Controller for A Single Pv Inverter System 被引量:1
7
作者 Suriana Salimin Matthew Armstrong Bashar Zahawi 《Engineering(科研)》 2013年第1期221-225,共5页
This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adv... This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adversely affect the power quality of the distribution network. Instead of using a conventional PI current controller with a fixed proportional and integral gain, development of new control method is considered to overcome the total harmonic emissions in PV inverters. It considers a modification to the controller where a random integral gain is used in the system. Experimental hardware is developed and result shows a reduced total harmonic distortion (THD) of the output current when tested with a resistive load. 展开更多
关键词 Total HARMONIC DISTORTION SINGLE inverter current controller
暂未订购
A Novel Fuzzy Direct Torque Control System for Three-level Inverter-fed Induction Machine 被引量:2
8
作者 Shu-Xi Liu Ming-Yu Wang +1 位作者 Yu-Guang Chert Shan Li 《International Journal of Automation and computing》 EI 2010年第1期78-85,共8页
Diode clamped multi-level inverter (DCMLI) has a wide application prospect in high-voltage and adjustable speed drive systems due to its low stress on switching devices, low harmonic output, and simple structure. Ho... Diode clamped multi-level inverter (DCMLI) has a wide application prospect in high-voltage and adjustable speed drive systems due to its low stress on switching devices, low harmonic output, and simple structure. However, the problem of complexity of selecting vectors and capacitor voltage unbalance needs to be solved when the algorithm of direct torque control (DTC) is implemented on DCMLI. In this paper, a fuzzy DTC system of an induction machine fed by a three-level neutral-point-clamped (NPC) inverter is proposed. After introducing fuzzy logic, optimal selecting switching state is realized by applying various strategies which can distinguish the grade of the errors of stator flux linkage, torque, the neutral-point potential, and the position of stator flux linkage. Consequently, the neutral-point potential unbalance, the dr/dr of output voltage and the switching loss are restrained effectively, and desirable dynamic and steady-state performances of induction machines can be obtained for the DTC scheme. A design method of the fuzzy controller is introduced in detail, and the relevant simulation and experimental results have verified the feasibility of the proposed control algorithm. 展开更多
关键词 Multi-level inverter direct torque control (DTC) fuzzy controller space voltage vector induction machine
在线阅读 下载PDF
Performance Study of PID Controller and LQR Technique for Inverted Pendulum 被引量:1
9
作者 Akhil Jose Clint Augustine +1 位作者 Shinu Mohanan Malola Keerthi Chacko 《World Journal of Engineering and Technology》 2015年第2期76-81,共6页
The inverted pendulum is a classic problem in dynamics and control theory and is widely used as a benchmark for testing control algorithms. It is unstable without control. The process is non linear and unstable with o... The inverted pendulum is a classic problem in dynamics and control theory and is widely used as a benchmark for testing control algorithms. It is unstable without control. The process is non linear and unstable with one input signal and several output signals. It is hence obvious that feedback of the state of the pendulum is needed to stabilize the pendulum. The aim of the study is to stabilize the pendulum such that the position of the carriage on the track is controlled quickly and accurately. The problem involves an arm, able to move horizontally in angular motion, and a pendulum, hinged to the arm at the bottom of its length such that the pendulum can move in the same plane as the arm. The conventional PID controller can be used for virtually any process condition. This makes elimination the offset of the proportional mode possible and still provides fast response. In this paper, we have modelled the system and studied conventional controller and LQR controller. It is observed that the LQR method works better compared to conventional controller. 展开更多
关键词 control System LQR TECHNIQUE CONVENTIONAL controller invertED PENDULUM
暂未订购
Repetitive PD control strategy with inverse transfer function compensation for CVCF inverter 被引量:2
10
作者 ShanxuDUAN 《控制理论与应用(英文版)》 EI 2004年第2期121-125,共5页
A novel repetitive control strategy for the output waveform of single-phase CVCF inverters is presented. In this scheme, the inverse transfer function of inverter is used as a compensator to obtain stable and satisfy ... A novel repetitive control strategy for the output waveform of single-phase CVCF inverters is presented. In this scheme, the inverse transfer function of inverter is used as a compensator to obtain stable and satisfy harmonic rejection. Besides, PD controller is adopted to improve transient performance. Simulation and experimental results, which are gotten from a DSP-based 400Hz, 5.5KW inverter, indicate that the proposed control scheme can achieve not only low THD during steady-state operation but also fast transient response during load step change. 展开更多
关键词 invertER Inverse transfer function Repetitive control PD control
在线阅读 下载PDF
Novel active fault-tolerant control scheme and its application to a double inverted pendulum system 被引量:3
11
作者 Cui Ping Weng Zhengxin Patton Ron 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第1期134-140,共7页
On the basis of the gain-scheduled H∞ design strategy, a novel active fault-tolerant control scheme is proposed. Under the assumption that the effects of faults on the state-space matrices of systems can be of affine... On the basis of the gain-scheduled H∞ design strategy, a novel active fault-tolerant control scheme is proposed. Under the assumption that the effects of faults on the state-space matrices of systems can be of affine parameter dependence, a reconfigurable robust H∞ linear parameter varying controller is developed. The designed controller is a function of the fault effect factors that can be derived online by using a well-trained neural network. To demonstrate the effectiveness of the proposed method, a double inverted pendulum system, with a fault in the motor tachometer loop, is considered. 展开更多
关键词 active fault-tolerant control neural network estimator gain-scheduled controller double inverted pendulum.
在线阅读 下载PDF
A Robust Deadbeat Control Method for UPS Inverters
12
作者 汪孟 李方正 +1 位作者 黄立培 SAKANE Makoto 《电工电能新技术》 CSCD 北大核心 2007年第4期31-35,64,共6页
The traditional deadbeat control for UPS inverters has a robustness problem. The parametric imprecision can greatly harm the stability of the system, which restricts the application. A novel robust deadbeat control me... The traditional deadbeat control for UPS inverters has a robustness problem. The parametric imprecision can greatly harm the stability of the system, which restricts the application. A novel robust deadbeat control method is proposed in this paper to deal with the problem. In the proposed control method, a proportional element is added to the traditional deadbeat control in order to improve the robustness to parametric imprecision. To eliminate the error between output voltage and voltage reference caused by environmental noise and parametric deviation, a model reference adaptive regulator is also added to the control method. A 1kVA prototype is built based on DSP. Theoretical analysis and experimental results show that the robustness for parametric variation of the proposed method is much better than the traditional deadbeat control. The system can remain stable even when the systemic parameters have a large deviation from calculating parameters. The system has small static error and fast dynamic response with the new control method. This method is easy to realize in DSP and is suitable for full digital realization of UPS. 展开更多
关键词 不间断电源逆变器 懒散控制 模型参考自适应控制 鲁棒性
在线阅读 下载PDF
A digital controlled alternating electromagnetic stirring generator based on dual inverter structure
13
作者 张芩 谢芳祥 +2 位作者 朱磊 叶惠 王振民 《China Welding》 EI CAS 2015年第4期74-80,共7页
A digital controlled alternating electromagnetic stirring generator is proposed in this paper. The main circuit of the generator makes use of dual inverter structure among which the former inverter uses full bridge ze... A digital controlled alternating electromagnetic stirring generator is proposed in this paper. The main circuit of the generator makes use of dual inverter structure among which the former inverter uses full bridge zero voltage switching topology and the latter inverter uses full bridge inverter circuit. To improve the dynamic response performance, the inverting frequency of the former inverter is as high us 100 kHz. The Cortex-M3 kernel based ARM microcontroller LM3S818 is adopted as the cybernetics core of the digital control system to achieve accurate, stable and flexible control of the generator. All the PWM signals for the former and latter inverters are generated by the LM3S818 directly. The constant current characteristic of the former inverter is obtained through current close-loop feedback control, and can ensure the operation safety when the output current waveform is at zero crossing point. Both simulation and experiment results show that the proposed generator is with such advantages as wide soft-switching range, perfect control accuracy and flexible waveform modulation, and can fulfill the requirements of electromagnetic stirring process. 展开更多
关键词 electromagnetic stirring generator dual inverter digital control SOFT-SWITCHING ARM
在线阅读 下载PDF
Data Logging and Control of a Remote Inverter Using LoRa and Power Line Communication
14
作者 K. A. Terashmila Lasagani Tariq Iqbal George K. Mann 《Energy and Power Engineering》 2018年第8期351-365,共15页
For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the r... For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the remote assets. The primary objective of this paper is to develop a communication link for monitoring and controlling a grid-connected inverter in a remote location. Furthermore, the paper presents developments that have been incorporated to improve the communication link. The literature survey indicates that LoRa is superior compared to other technologies, but has some security and reliability issues. This paper also presents an encryption algorithm to improve the security of the LoRa link. Local data storage added to the system before transmitting data increases the system reliability. A display at the transmission end is added to improve the user-friendliness of the communication link. A Powerline Communication link is parallelly added to the LoRa link to improve the reliability. Finally, tests are conducted with an actual inverter and the results are presented. The tests show that the developed communication link has improved security and reliability, while its open nature makes it highly scalable and adaptable for employment in other smart grid applications. 展开更多
关键词 LoRa Application Supervisory control and Data ACQUISITION System invertER REMOTE control Power LINE COMMUNICATION
暂未订购
Real-Time Implementation of Solar Inverter with Novel MPPT Control Algorithm for Residential Applications
15
作者 Ayaz Ahmad Rajaji Loganathan 《Energy and Power Engineering》 2013年第6期427-435,共9页
Solar energy is a fast growing energy resource among the renewable energy resources in the market and potential for solar power is huge to contribute towards the power demand almost in all the countries. To capture th... Solar energy is a fast growing energy resource among the renewable energy resources in the market and potential for solar power is huge to contribute towards the power demand almost in all the countries. To capture the maximum power from the sun light in order to generate maximum power from the inverter, control system must be an equally efficient with the well designed power electronic circuits. Maximum power point tracking (MPPT) control system in general is taking care of extraction of maximum power from the sun light whereas current controller is mainly designed to optimize the inverter power to feed to power grid. In this paper, a novel MPPT algorithm using neuro fuzzy system is presented to ensure the maximum MPPT efficiency in order to ensure the maximum power across the inverter terminals. Simulation and experimental results for residential solar system with power electronic converters and analysis have been presented in this paper in order to prove the proposed algorithm. 展开更多
关键词 PV Cells SOLAR invertER MPPT control DCDC CONVERTER and Current controlLER
暂未订购
Sizing of a Filter (<i>L-C</i>) for a 180°Control Inverter Connected to a Medium Voltage Network
16
作者 Kouakou Fernand Koffi Gondo Yake +2 位作者 Raymond Gbegbe Georges Loum Olivier Asseu 《Open Journal of Applied Sciences》 2021年第5期565-576,共12页
This paper studies the design and sizing of a filter (<em>L-C</em>) for an inverter with 180<span style="white-space:nowrap;"><span style="white-space:nowrap;">&#176;<... This paper studies the design and sizing of a filter (<em>L-C</em>) for an inverter with 180<span style="white-space:nowrap;"><span style="white-space:nowrap;">&#176;</span></span> control in Medium voltage (MV), based on formulas of the capacitance of the capacitor <em>C</em> and the inductance <em>L</em> of the filter (<em>L-C</em>) of an SPWM inverter. These formulas were obtained by minimizing two parameters: the reactive power of the capacitor (capped at 5% of the apparent power of the load) and the ripple of the current flowing through inductance <em>L</em> (capped at 10% of the current supplying the load). The application of these formulas for the calculation of the filter (<em>L-C</em>) of the 180<span style="white-space:nowrap;">&#176;</span> control inverter in MV is not conclusive. Studies have been carried out to make them applicable. The results show that limiting the current ripple in the inductor to 10% of the load current is a valid assumption and that limiting the reactive power of the capacitor to 5% of the apparent power of the load presents shortcomings. The results also show that setting the inductance <em>L</em> of the filter to <em>L<sub>maxi </sub></em>and the capacitor <em>C </em>from 35 × <em>C<sub>maxi</sub></em> to 400 × <em>C</em><em><sub>maxi </sub></em>gives voltage and current THDs that meet the 519 IEEE-2014 standards. 展开更多
关键词 filter (L-C) THD inverter with 180° control and with SPWM control mathematical iterations MV. MATLAB-SIMULINK
在线阅读 下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
17
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE GRID-CONNECTED inverter DECOUPLING control
在线阅读 下载PDF
Unified Control Strategy of PV Inverter Mixed Power Quality Control
18
作者 Jie Zhang Kai Yao +1 位作者 Liang Li Wei Zhao 《Energy and Power Engineering》 2013年第4期226-229,共4页
Due to the restriction of light illumination condition, the effective utilization of PV grid-connected systems is very low. In view of this question, this paper presents a unified control strategy based on PV grid-con... Due to the restriction of light illumination condition, the effective utilization of PV grid-connected systems is very low. In view of this question, this paper presents a unified control strategy based on PV grid-connected and active power filter. The distributed small-capacity grid-connected inverter is chose to be the research object. It is preferential to eliminate the deviation between power qualities of the national standards according to the control of decision tables, and adjust the proportion of the compensation currents dynamically. Finally, the simulation results demonstrate the effectiveness of this unified control strategy. 展开更多
关键词 PV invertER APF UNIFIED control DECISION TABLE
在线阅读 下载PDF
Stability Analysis of a Neurocontroller with Kalman Estimator for the Inverted Pendulum Case
19
作者 Julián Antonio Pucheta Cristian Rodríguez Rivero +2 位作者 Carlos Alberto Salas Martín Herrera Sergio Oscar Laboret 《Applied Mathematics》 2017年第11期1602-1618,共17页
In this paper, a practical analysis of stability by simulation for the effect of incorporating a Kalman estimator in the control loop of the inverted pendulum with a neurocontroller is presented. The neurocontroller i... In this paper, a practical analysis of stability by simulation for the effect of incorporating a Kalman estimator in the control loop of the inverted pendulum with a neurocontroller is presented. The neurocontroller is calculated by approximate optimal control, without considering the Kalman estimator in the loop following the Theorem of the separation. The results are compared with a time-varying linear controller, which in noiseless conditions in the state or in the measurement has an acceptable performance, but when it is under noise conditions its operation closes into a state space range more limited than the one proposed here. 展开更多
关键词 OPTIMAL control Neurocontroller invertED PENDULUM STATE Estimation Stability
在线阅读 下载PDF
INTELLIGENT CONTROL SYSTEM OF PULSED MAG WELDING INVERTER BASED ON DIGITAL SIGNAL PROCESSOR
20
作者 WU Kaiyuan HUANG Shisheng WU Shuifeng LI Xinglin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第6期86-90,共5页
A fuzzy logic intelligent control system of pulsed MAG welding inverter based on digital signal processor (DSP) is proposed to obtain the consistency of arc length in pulsed MAG welding. The proposed control system ... A fuzzy logic intelligent control system of pulsed MAG welding inverter based on digital signal processor (DSP) is proposed to obtain the consistency of arc length in pulsed MAG welding. The proposed control system combines the merits of intelligent control with DSP digital control. The fuzzy logic intelligent control system designed is a typical two-input-single-output structure, and regards the error and the change in error of peak arc voltage as two inputs and the background time as single output. The fuzzy logic intelligent control system is realized in a look-up table (LUT) method by using MATLAB based fuzzy logic toolbox, and the implement of LUT method based on DSP is also discussed. The pulsed MAG welding experimental results demonstrate that the developed fuzzy logic intelligent control system based on DSP has strong arc length controlling ability to accomplish the stable pulsed MAG welding process and controls pulsed MAG welding inverter digitally and intelligently. 展开更多
关键词 Pulsed MAG welding inverter Arc length control Fuzzy logic intelligent control Digital signal processor (DSP)
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部