期刊文献+
共找到200,876篇文章
< 1 2 250 >
每页显示 20 50 100
Clinical Efficacy of Different Internal Fixation Implants for Post-Traumatic Nonunion of Limb Fractures:A Comparative Study
1
作者 Li He Cheng Weiqiang Zhu Dingguo 《Science International Innovative Medicine》 2025年第2期25-30,共6页
To compare the clinical efficacy of locking plate(LP)fixation and intramedullary nail(IMN)fixation for the treatment of post-traumatic nonunion of diaphyseal fractures of the femur and tibia.Methods:This single-center... To compare the clinical efficacy of locking plate(LP)fixation and intramedullary nail(IMN)fixation for the treatment of post-traumatic nonunion of diaphyseal fractures of the femur and tibia.Methods:This single-center retrospective comparative study included 50 adult patients with aseptic nonunion of femoral or tibial diaphyseal fractures treated at our institution between January 2015 and January 2025.Patients underwent either locking-plate(LP)fixation(n=25)or intramedullary nailing(IMN)(n=25).The primary outcome was radiographic union at 12 months postoperatively.Secondary outcomes included time to union,operative time,intraoperative blood loss,length of hospital stay,incidence of complications(superficial/deep infection,implant failure,malunion),and 12-month functional status assessed by the Lower Extremity Functional Scale(LEFS).Statistical comparisons used Welch t tests for continuous variables and χ^(2) or Fisher exact tests for categorical variables.The protocol received institutional review board approval with waiver of informed consent.Results:Among 50 patients(LP=25;IMN=25),the 12-month union rate was 88.00%(22/25)in the LP group and 96.00%(24/25)in the IMN group(p=0.609).Time to union was shorter with IMN(6.20±1.83 vs 7.51±2.12 months;p=0.023).Operative time(110.52±25.23 vs 145.81±30.21 min;p<0.01)and intraoperative blood loss(250.41±80.64 vs 350.22±95.30 ml;p<0.01)favored IMN.Length of hospital stay was similar(6.24±1.83 vs 6.82±2.11 days;p=0.284).The incidence of superficial wound infection did not differ significantly(12.00%vs 4.00%;p=0.609).Twelve-month LEFS scores were comparable(65.44±10.21 vs 67.10±9.83;p=0.451).Conclusion:Both locking plate and intramedullary nail fixation are effective in the treatment of femoral and tibial nonunion,with high rates of union and good functional outcomes.Intramedullary nailing may be associated with a shorter time to union,reduced operative time and blood loss,and a lower risk of superficial wound infection compared to locking plate fixation.The choice of implant should be individualized based on fracture characteristics,patient factors,and surgeon preference. 展开更多
关键词 NONUNION Limb Fractures internal fixation Locking Plate Intramedullary Nail Clinical Efficacy
暂未订购
Analysis of Therapeutic Effects of Dental Arch Splint Intermaxillary Traction Combined with Rigid Internal Fixation in Patients with Facial Comminuted Fractures
2
作者 Xiaohua Zhang 《Journal of Clinical and Nursing Research》 2025年第1期81-87,共7页
Objective: To analyze the therapeutic effect of combining dental arch splint intermaxillary traction with rigid internal fixation for the treatment of facial comminuted fractures. Methods: Sixty patients with facial c... Objective: To analyze the therapeutic effect of combining dental arch splint intermaxillary traction with rigid internal fixation for the treatment of facial comminuted fractures. Methods: Sixty patients with facial comminuted fractures admitted for treatment between July 2023 and December 2024 were selected. Using a random number table method, 30 patients were assigned to the observation group, where moderate traction using a dental arch splint combined with rigid internal fixation was applied. Another 30 patients were assigned to the control group and only received dental arch splint traction treatment. The total effective rate, postoperative recovery indicators, periodontal status, complication rate, and quality of life scores were compared between the two groups. Results: The total effective rate in the observation group was higher than that in the control group. The postoperative recovery indicators and periodontal status in the observation group were superior to those in the control group. The complication rate and quality of life score were lower in the observation group compared to the control group, with P < 0.05. Conclusion: Combining dental arch splint intermaxillary traction with rigid internal fixation can improve the periodontal status and quality of life of patients with facial comminuted fractures, shorten postoperative recovery time, reduce various complications, and enhance surgical efficacy. 展开更多
关键词 Dental arch splint intermaxillary traction Rigid internal fixation Facial comminuted fracture Therapeutic effect
暂未订购
Biological nitrogen and carbon fixation:Bridging the gap between synthetic symbioses and synthetic biology 被引量:1
3
作者 Qi Cheng Chukang Ma Xuelu Wang 《The Crop Journal》 2026年第1期74-86,共13页
Biological nitrogen fixation(BNF)and photosynthetic carbon fixation underpin food production and climate mitigation,yet natural systems are constrained by oxygen sensitivity,high energy demand,and inefficient catalyst... Biological nitrogen fixation(BNF)and photosynthetic carbon fixation underpin food production and climate mitigation,yet natural systems are constrained by oxygen sensitivity,high energy demand,and inefficient catalysts.This review synthesizes advances that recast these processes as engineering targets and proposes a conceptual roadmap that bridges synthetic symbioses with the synthetic biology of enzymes and pathways.For BNF,progress spans cross-kingdom strategies—from refactoring nif gene sets and targeting nitrogenase assembly to eukaryotic organelles,to engineering plant-associated diazotrophs,rhizosphere control circuits,and emerging nodule-like microenvironments.For carbon assimilation,new-to-nature CO_(2)-fixation modules and photorespiratory bypasses illustrate how pathway redesign and alternative carboxylases can circumvent key Calvin–Benson–Bassham limitations,and expanding photosynthetic light capture offers additional leverage.Across these domains,we extract common design principles:(i)nitrogenase output is increasingly governed by carbon/energy supply and electron delivery as much as by oxygen protection;(ii)robust function requires compartment-aware enzyme–chassis coordination,substrate channeling,and dynamic regulation using sensors and control circuits;and(iii)scalable implementation may benefit from distributing metabolic labor across engineered consortia rather than forcing all functions into a single host.We discuss enabling technologies—including AI-guided protein design and directed evolution,cell-free prototyping,chassis toolkits,and materials/bioelectrochemical interfaces—that can accelerate design–build–test–learn cycles and reduce barriers to deployment.Together,these insights define a path toward integrated nitrogen and carbon fixation systems for low-emission agriculture and biomanufacturing. 展开更多
关键词 Biological nitrogen fixation Photosynthetic carbon fixation Nitrogenase engineering Non-natural enzymes AI-guided protein design
在线阅读 下载PDF
Facile method for creating frustrated Lewis pairs in g-C_(3)N_(4) to enhance photocatalytic nitrogen fixation performance
4
作者 Lanxin Wang Kaiwei Liang +2 位作者 Xuelian Yu Guocheng Lv Libing Liao 《Chinese Chemical Letters》 2026年第1期622-625,共4页
The rate-limited activation of N≡N triple bonds with high bond energies has been a bottleneck in photoctalytic nitrogen fixation.Here,polymeric carbon nitride with frustrated Lewis pairs(FLPs) was constructed by inse... The rate-limited activation of N≡N triple bonds with high bond energies has been a bottleneck in photoctalytic nitrogen fixation.Here,polymeric carbon nitride with frustrated Lewis pairs(FLPs) was constructed by inserting electron-deficient magnesium into g-C_(3)N_(4)(CN).The synergistic interactions between Mg and amino groups in CN led to a 7.2 fold increase in the photoreactivity of nitrogen(N_(2)) fixation by carbon nitride. 展开更多
关键词 N_(2)fixation PHOTOCATALYTIC FLPs AMMONIA g-C_(3)N_(4)
原文传递
Combined Fault Tree Analysis and Bayesian Network for Reliability Assessment of Marine Internal Combustion Engine
5
作者 Ivana Jovanović Çağlar Karatuğ +1 位作者 Maja Perčić Nikola Vladimir 《哈尔滨工程大学学报(英文版)》 2026年第1期239-258,共20页
This paper investigates the reliability of internal marine combustion engines using an integrated approach that combines Fault Tree Analysis(FTA)and Bayesian Networks(BN).FTA provides a structured,top-down method for ... This paper investigates the reliability of internal marine combustion engines using an integrated approach that combines Fault Tree Analysis(FTA)and Bayesian Networks(BN).FTA provides a structured,top-down method for identifying critical failure modes and their root causes,while BN introduces flexibility in probabilistic reasoning,enabling dynamic updates based on new evidence.This dual methodology overcomes the limitations of static FTA models,offering a comprehensive framework for system reliability analysis.Critical failures,including External Leakage(ELU),Failure to Start(FTS),and Overheating(OHE),were identified as key risks.By incorporating redundancy into high-risk components such as pumps and batteries,the likelihood of these failures was significantly reduced.For instance,redundant pumps reduced the probability of ELU by 31.88%,while additional batteries decreased the occurrence of FTS by 36.45%.The results underscore the practical benefits of combining FTA and BN for enhancing system reliability,particularly in maritime applications where operational safety and efficiency are critical.This research provides valuable insights for maintenance planning and highlights the importance of redundancy in critical systems,especially as the industry transitions toward more autonomous vessels. 展开更多
关键词 Fault tree analysis Bayesian network RELIABILITY REDUNDANCY internal combustion engine
在线阅读 下载PDF
Minimally invasive four-point scleral refixation for dislocated 4-haptic IOL by horizontal mattress sutures and Hoffman pockets
6
作者 Zhao-Liang Zhang Jia-Hui Shen +3 位作者 Jun-Yi Chen Qin-Tuo Pan Xu-Ting Hu Zong-Duan Zhang 《International Journal of Ophthalmology(English edition)》 2026年第3期483-489,共7页
AIM:To evaluate the clinical outcomes of a new minimally invasive technique using horizontal mattress sutures and Hoffman pockets for four-point refixation of dislocated fourhaptic intraocular lenses(IOLs).METHODS:Thi... AIM:To evaluate the clinical outcomes of a new minimally invasive technique using horizontal mattress sutures and Hoffman pockets for four-point refixation of dislocated fourhaptic intraocular lenses(IOLs).METHODS:This retrospective consecutive case series included eyes with dislocated Akreos AO60 IOLs underwent scleral refixation using a horizontal mattress doubleneedle suture technique with intralamellar knot burial via Hoffman pockets.Clinical outcomes assessed included pre-and postoperative best-corrected visual acuity(BCVA),intraocular pressure(IOP),spherical equivalent(SE),suture duration,IOL centration,and perioperative complications.RESULTS:A total of 10 eyes from 10 patients(6 males)were included.The mean age at the time of IOL refixation was 53.10±13.07y(range:28-68y).The mean interval between initial IOL implantation and dislocation was 8.44±3.54y.The mean postoperative follow-up duration was 11.45±10.30mo.Surgical time averaged 15.3±1.77min,with no intraoperative complications.The mean axial length was 27.16±4.35 mm,with high myopia(HM)as the leading comorbidity(4/10 eyes).Postoperative BCVA significantly improved compared to preoperative values(P=0.025).Postoperative SE was significantly improved compared with preoperative(P=0.01).All IOLs remained centered throughout follow-up.CONCLUSION:This minimally invasive four-point scleral fixation technique offers a safe and effective refixation strategy for dislocated four-haptic IOLs.The horizontal mattress suture configuration combined with Hoffman pockets facilitates durable centration,avoids conjunctival dissection,and could be adopted into routine surgical practice. 展开更多
关键词 intraocular lens dislocation four-haptic intraocular lens intraocular lens refixation scleral fixation horizontal mattress suture Hoffman pocket minimally invasive ophthalmic surgery
原文传递
Mindfulness and internalizing/externalizing problems among adolescents:Ethnicity moderation and psychological capital mediation
7
作者 Jia Wu Wei Luo +4 位作者 Qianguo Xiao Qinhong Xie Xiaodong Li Taiyong Bi Hui Kou 《Journal of Psychology in Africa》 2026年第1期97-106,共10页
This study examines the mediating role of positive psychological capital and the moderating role of ethnicity in the relationship between mindfulness and internalizing/externalizing problems among adolescents.The stud... This study examines the mediating role of positive psychological capital and the moderating role of ethnicity in the relationship between mindfulness and internalizing/externalizing problems among adolescents.The study sample comprized Chinese adolescents(N=637 ethnic minority;females=40.97%,meam age=12.68,SD=0.49 years;N=636 Han;females=49.06%,mean age=12.71,SD=0.47 years).The participants completed the Child and Adolescent Mindfulness Measure,the Positive Psycap Questionnaire,and the Youth Self-Report.Results from the moderated mediation analysis showed mindfulness was negatively associated with both internalizing and externalizing problems.Ethnicity moderated the relationship between mindfulness and internalizing problems to be stronger for Han adolescents compared to ethnic minority adolescents.Psychological capital mediated the relationship between mindfulness and internalizing problems in both groups,with a negative direction.Findings support the Conservation of Resources theory and highlight mindfulness as a personal resource fostering adolescent well-being in multicultural contexts. 展开更多
关键词 Ethnic minority adolescent MINDFULNESS positive psychological capital internalizing problems externalizing problems
在线阅读 下载PDF
Cu doping induced lattice distortion and oxygen vacancy formation in PbBiO_(2)Br:Band structure modulation enhances photocatalytic nitrogen fixation and pollutant degradation performance
8
作者 Shude Yuan Yekang Zheng +6 位作者 Yuxin Chu Chuanqi Xia Ruoyu Dong Jiating Xu Botao Teng Ying Wu Yiming He 《Green Energy & Environment》 2026年第1期211-223,共13页
Photocatalytic nitrogen fixation has emerged as a sustainable alternative for ammonia synthesis,playing a crucial role in alleviating energy shortages and environmental pollution.In this study,PbBiO_(2)Br was applied ... Photocatalytic nitrogen fixation has emerged as a sustainable alternative for ammonia synthesis,playing a crucial role in alleviating energy shortages and environmental pollution.In this study,PbBiO_(2)Br was applied to photocatalytic nitrogen fixation for the first time,and its photocatalytic performance was effectively enhanced through Cu doping.The catalyst was synthesized via a simple reduction method,and its morphology,structure,and physicochemical properties were systematically investigated using various characterization techniques and density functional theory calculations.The results revealed that the incorporation of Cu2+partially replaced Pb2+,inducing lattice distortion in PbBiO_(2)Br,promoting the formation of oxygen vacancies,and modifying its electronic band structure.Specifically,Cu doping led to a slight bandgap narrowing,a reduction in work function,and a significant upward shift in the conduction band position.These changes enhanced light absorption,facilitated charge carrier migration and separation,and improved the reduction ability of photogenerated electrons.Moreover,Cu doping promoted N_(2)adsorption and activation.Consequently,the photocatalytic nitrogen fixation performance of Cu-doped PbBiO_(2)Br was significantly enhanced,achieving an optimal nitrogen fixation rate of 293μmol L^(−1)g^(−1)h^(−1),which is 3.6 times higher than that of pristine PbBiO_(2)Br.Additionally,Cu–PbBiO_(2)Br also showed good activity in the photocatalytic degradation of RhB,with a degradation rate 4.6 times higher than that of PbBiO_(2)Br.This work offers new insights into the application of PbBiO_(2)Br in photocatalytic nitrogen fixation and offers valuable guidance for the development of highly efficient nitrogen fixation materials in the future. 展开更多
关键词 PbBiO_(2)Br Cu doping Oxygen vacancy Charge separation Photocatalytic N_(2)fixation
在线阅读 下载PDF
CO_(2)utilization and fixation in biomass-derived furanics conversion:Thermochemical and electrochemical pathways
9
作者 Saeideh Gharouni Fattah Sabah Karimi +5 位作者 Shaoyu Yuan Zheng Li Mohammad Jalal Zohuriaan-Mehr Lu Lin Xianhai Zeng Buxing Han 《Green Energy & Environment》 2026年第1期1-22,共22页
Carbon dioxide(CO_(2))is the main greenhouse gas(GHG)released by human activities.The substitution of fossil resources by biomass as a bio-renewable resource,has significant potential to reduce GHG emissions.The appro... Carbon dioxide(CO_(2))is the main greenhouse gas(GHG)released by human activities.The substitution of fossil resources by biomass as a bio-renewable resource,has significant potential to reduce GHG emissions.The approach to biomass,as the only true full-scale alternative to fossil resources,is progressing rapidly.Converting biomass into furanic compounds,as versatile platform chemicals for synthesizing a wide range of bio-based products is the cornerstone of sustainable technologies.The extensive body of this review combines the biomass valorization to furanic compounds by CO_(2)utilization and furanic compounds conversion by CO_(2)fixation.These processes can be strategically applied through both‘thermochemical’and‘electrochemical’pathways,by utilizing CO_(2)from the atmosphere or industrial emission point and returning it to the natural carbon cycle.In the thermochemical pathway CO_(2)acts as a carbon source(carboxylation and polymerization)or active reaction assistant in the biomass conversion(CO_(2)-assisted conversion),without altering its oxidation state,facilitating the synthesis of valuable products and polymers.Conversely,in the electrochemical pathway,CO_(2)can be used as a carbon source(electrocarboxylation)to give the corresponding carboxylic acid,or it can undergo reduction,yielding methanol,carbon monoxide(CO),formic acid,and analogous compounds,while on the other side,furanic compounds undergo oxidation yielding high-value-added chemicals.Finally,potential future research directions are suggested to promote CO_(2)utilization and fixation in the valorization of biomass-derived furanic compounds,and challenges facing further research are highlighted. 展开更多
关键词 CO_(2)utilization and fixation Biomass valorization Furanic compounds Thermochemical and electrochemical pathways Renewable and sustainable resources
在线阅读 下载PDF
Bi-Bi_(2)Ti_(2)O_(7) ohmic junction:Dual electron channels driving efficient photocatalytic nitrogen fixation
10
作者 Pengkun Li Runjie Wu +5 位作者 Shuai Gao Zeping Qin Mingming Sun Changzheng Wang Wenming Sun Qiang Wang 《Chinese Chemical Letters》 2026年第1期563-569,共7页
Photocatalysis uses solar energy to convert nitrogen and water directly into ammonia,helping reduce dependence on fossil fuels and offering a way to integrate the nitrogen cycle into a clean energy network.Ohmic junct... Photocatalysis uses solar energy to convert nitrogen and water directly into ammonia,helping reduce dependence on fossil fuels and offering a way to integrate the nitrogen cycle into a clean energy network.Ohmic junctions between metals and semiconductors have demonstrated significant advantages in enhancing stability and reducing carrier recombination,but their application in photocatalytic nitrogen fixation is limited due to the difficulty of work function matching and the complexity of fabrication processes.In this study,density functional theory(DFT) calculations were used to confirm the work function matching between Bi and Bi_(2)Ti_(2)O_(7)(BTO),ensuring the formation of an Ohmic junction.A Bi-Bi_(2)Ti_(2)O_(7)(B-BTO) composite was successfully synthesized via a one-step hydrothermal method,using bismuth nitrate and titanium sulfate as precursors.Compared to pure BTO,the B-BTO heterojunction,driven by dual electron injection from both metal Bi and BTO,significantly increased the ammonia synthesis rate to 686.95 μmol g^(-1)h^(-1),making it the most active nitrogen fixation material among similar pyrochlorebased catalysts to date.The differential charge density calculations,photocurrent(i-t) measurements,and photoluminescence(PL) tests further validate the role of Ohmic contacts in enhancing charge transfer and prolonging carrier lifetimes.This research provides valuable insight into the application of Ohmic junctions in photocatalytic nitrogen fixation and contributes to advancements in this field. 展开更多
关键词 PHOTOCATALYTIC N_(2)fixation Ohmic junction Dual electron channels Bi_(2)Ti_(2)O_(7)
原文传递
Effect of dominant fractures on triaxial behavior of 3D-printed rock analogs with internal fracture networks
11
作者 Lishuai Jiang Pimao Li +3 位作者 Xin He Yang Zhao Quansen Wu Ye Zhao 《Journal of Rock Mechanics and Geotechnical Engineering》 2026年第2期1390-1412,共23页
Internal structural defects in engineering rock masses vary in size,exhibit complex shapes,and are unevenly distributed.Dominant fractures within a rock mass often play a critical to its mechanical behavior,directly a... Internal structural defects in engineering rock masses vary in size,exhibit complex shapes,and are unevenly distributed.Dominant fractures within a rock mass often play a critical to its mechanical behavior,directly affecting the macromechanical properties and failure modes.These fractures affect the instability and failure of the surrounding rock,significantlyimpacting the overall stability of engineering structures.Herein,sand-powder three-dimensional(3D)printing technology was used to prepare rock-like specimens with internal fracture networks.Triaxial compression testing,post-failure fracture mapping,and fractal dimension analysis of the fracture surfaces were conducted to investigate the effects of dominant fracture angles on the strength and deformation of rocks with internal fracture networks under triaxial stress.The results indicate that the dominant fracture angle has a pronounced effect on the mechanical behavior of rock.With increasing angle,both compressive strength and elastic modulus exhibit an initial decline followed by an increase.Moreover,higher confiningpressure significantlyimproves the compressive strength of fractured rock.This enhancement weakens as the confiningpressure further increases.Moreover,with increasing confiningpressure,the differences between the maximum and minimum values of elastic moduli and lateral strain ratios in fractured rock gradually decrease.Thus,the impact of the dominant fracture angle on rock mass deformation decreases with increasing confiningpressure.This research elucidates the effects of dominant fracture angles on the mechanical and failure properties of complex fractured rock masses and the influenceof the confiningpressure on these relationships.It provides valuable theoretical insights and practical guidance for stability analyses in engineering rock masses. 展开更多
关键词 Sand powder three-dimensional(3D) printing internal fracture networks Triaxial compression Rock mechanics Fractal dimension
在线阅读 下载PDF
SWOT observation revealed internal solitary wave characteristic variations in the Lombok Strait
12
作者 Xiaochen WANG Jing WANG +1 位作者 Xudong ZHANG Jiaxin LIU 《Journal of Oceanology and Limnology》 2026年第1期71-84,共14页
Internal solitary waves(ISWs)are an essential dynamic process in the ocean due to their large amplitude and long propagation distance.Traditional satellite observations provide only twodimensional observations of ocea... Internal solitary waves(ISWs)are an essential dynamic process in the ocean due to their large amplitude and long propagation distance.Traditional satellite observations provide only twodimensional observations of ocean signatures induced by ISWs.The Surface Water and Ocean Topography(SWOT)satellite has drawn significant attention due to its high resolution and threedimensional observation capabilities.SWOT can generate high-precision three-dimensional sea surface topography,capture sea surface undulations,and reveal ISW-related surface oscillations,thus offering a new perspective for studying ISWs.We collected 43 SWOT observations with clear ISW signatures in the Lombok Strait from August 2023 to June 2024.Based on collected data,the ISW imaging characteristics and distributions were analyzed,and the ISW-related sea level anomaly(SLA)data were measured by the SWOT to calculate the ISW amplitude and reveal the amplitude variations during the propagation along the wave crest.The ISW amplitudes generally range between 10 and 100 m,with most ISW amplitudes between 20 and 40 m.By analyzing two consecutive generated ISW packets,we identified the spreading effect along ISW wave crests,which manifests as ISW amplitude decrease with increase in propagation distance,and the amplitude distribution is non-uniform along the wave crest.Further analysis of the propagation paths of the maximum amplitude of ISW moving northward through the Lombok Strait revealed that these maxima are predominantly oriented in northeast direction.Finally,the relationship between the amplitude of ISW and the resulting SLA was analyzed.The Pearson correlation coefficient between these two variables is as high as 0.90,which suggests a strong positive correlation between amplitude and SLA.Furthermore,this relationship is closely related to the water depth,indicating that the three-dimensional sea surface observations provided by SWOT offer crucial observational data for the inversion of amplitudes of ISW. 展开更多
关键词 internal solitary wave(ISW) Surface Water and Ocean Topography(SWOT) AMPLITUDE Lombok Strait
在线阅读 下载PDF
关于Rigid Internal Fixation一词译法和应用的说明
13
作者 顾晓明 《中国口腔颌面外科杂志》 CAS 2004年第1期21-21,共1页
关键词 igid internal fixation RIF 内固定 口腔颌面部 力学设计
暂未订购
Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10
14
作者 Zhe Chen Jia-Sen Wei +3 位作者 Zhao-Yang Hou Jiong Hu Yan-Guang Cao Qi-Xin Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页
Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of... Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. 展开更多
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP internal fixation ANKLE function
暂未订购
Open reduction and internal fixation for radial head fractures: A prospective observational study 被引量:4
15
作者 Imran Khan Mangi Arslan Ahmed Abro +4 位作者 Muhammad Naveed Memon Shahjahan Siyal Naveed Khan Nouman Memon Muhammad Kazim Rahim Najjad 《Journal of Acute Disease》 2020年第4期166-169,共4页
Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to J... Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to July 2017 at Liaquat National Hospital and Medical College, Karachi. Altogether, 28 patients with radial head and neck fractures were enrolled in our study. These patients were admitted to the hospital and their fractures were fixed with open reduction and internal fixation. Baseline information of the patients was collected, and patient-rated elbow evaluation scores were calculated. Results: Out of the 28 patients, 21 were male and 7 were female. Besides, 16 fractures were on the right side and 12 were on the left side and 17 involving the dominant hands. In addition, 8 patients had Mason type Ⅱ fracture and 20 had Mason type Ⅲ fracture. The mean age of patients was (31.0 ± 8.0) years, and the mean follow-up is (1.2 ± 0.5) years. The mean average patient-rated elbow evaluation scores were (27.64 ± 1.60) at 1-year follow-up. Conclusions:The majority of the patients who had radial head fractures and treated by open reduction and internal fixation have attained an excellent range of motion postoperatively. 展开更多
关键词 Radial head fractures Open reduction and internal fixation Functional outcome
暂未订购
The Use of Calcaneal Anatomic Plate in Arthroscopically-assisted Open Reduction and Internal Fixation of Intra-articular Calcaneal Fractures 被引量:1
16
作者 王洪 张青松 +1 位作者 段德宇 严力军 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第3期319-321,共3页
To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus i... To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus in 78 patients were reduced by open reduction, and rigid fixation was made with calcaneal anatomic plate under assistant of arthroscope. The average follow-up duration was 18 months (range 12-30 months). The effect of treatment was evaluated according to AOFAS and X-ray before and after operation. The results showed that 86 patients have obtained satisfactory reduction according to X-ray, and there was significant difference before and after operation (P〈0. 01), the total excellent and fine rate was 91.86%. Treating intra-articular fractures of the calcaneus with calcaneal anatomic plate under arthroscope may provide more chance to achieve anatomical reconstruction, which can lead to satisfied recovery of function and few complication. 展开更多
关键词 Fracture of Calcaneus Calcaneal Anatomic Plate ARTHROSCOPE internal fixation
暂未订购
Comparative study of various internal fixation methods for treating patellar fractures by three-dimensional photoelasticity 被引量:2
17
作者 许硕贵 苏佳灿 +4 位作者 张春才 曾伟明 顾绍德 张林春 方如华 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第6期384-387,共4页
Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin thre... Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin three dimensional photoelasticity patellar models were made by precise moulding, and were fixated by nitinol patellar concentrator (NT-PC), tension band and wire circle respectively. The patellar models with frozen stress stripes were put into the polarized light field and the stress distributions were compared. As for the model fixated by NT-PC, by dividing layer, photographing and tracing, we used the iterative method to calculate the stress value of every internal node of the epoxy resin patellar model, and the character of stress was analyzed. Results: An overall stress field was yielded when the patellar model was fixated by NT-PC, and the stripes were more than that of tension band model and wire circle model, which have only few stress stripes in the fixated layers. Further analysis indicated that there were continuous fixated stresses in the facies articularis and distal pole of patella, and the character of stresses produced by NT-PC were mainly in longitudinal direction, then in transverse direction. The shearing stresses were small. Conclusion: The initiative and continuous memorial stress of NT-PC and its overall stress distribution character are the essence of NT-PC distinguished with tension band and wire circle in treating patellar fractures. The stress character produced by NT-PC is good for the stability of fracture site and prompts fracture healing. 展开更多
关键词 internal fixation patellar fracture PHOTOELASTICITY STRESS nitinol patellar concentrator
暂未订购
Three-dimensional finite element analysis with different internal fixation methods through the anterior approach 被引量:3
18
作者 Xian-Jin Xie Sheng-Lu Cao +2 位作者 Kai Tong Zi-Yi Zhong Gang Wang 《World Journal of Clinical Cases》 SCIE 2021年第8期1814-1826,共13页
BACKGROUND With the modernization of society and transportation in the last decades in China,the incidence of high-energy trauma increased sharply in China,including that of acetabular fractures.AIM To establish diffe... BACKGROUND With the modernization of society and transportation in the last decades in China,the incidence of high-energy trauma increased sharply in China,including that of acetabular fractures.AIM To establish different finite element models for acetabular posterior column fractures involving the quadrilateral area of the acetabulum.METHODS The three-dimensional models of the normal and fractured pelvis and the five internal fixations were established using the computed tomography data of the pelvis of a living volunteer.After the vertebral body model was inserted in the way of origin matching and all cancellous bones were copied using the duplicated cancellous bone model as the subtractive entity,the Boolean operation was performed on the pelvis model to obtain the model of the complete pelvis cortical and cancellous bones.RESULTS In the standing position,the maximum stress was 46.21 MPa.In the sitting position,the sacrum bore the simulated gravity load at the upper end.When comparing the five fixations,there were no significant differences in the stress mean values among groups(sitting:P=0.9794;standing:P=0.9741).In terms of displacement,the average displacement of the internal iliac plate group was smaller than that of the spring plate group(P=0.002),and no differences were observed between the other pairs of groups(all P>0.05).In the standing position,there were no significant differences in the mean value of displacement among the groups(P=0.2985).It can be seen from the stress nephogram of the internal fixations in different positions that the stress of the internal fixation was mainly concentrated in the fracture segment.CONCLUSION There were no significant differences among the fixations for acetabular posterior column fractures involving the quadrilateral area of the acetabulum. 展开更多
关键词 ACETABULUM Hip fractures ANALYSIS Finite element Fracture fixation Orthopedic fixation devices
暂未订购
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
19
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex Acetabular Fracture internal fixation Open Reduction OUTCOME
暂未订购
Triple Arthrodesis with Internal and External Fixation: Technique Paper 被引量:1
20
作者 Luis E. Marin Randy Semma Nisha Bala Krishnan 《Surgical Science》 2014年第4期183-192,共10页
Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate functio... Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate function. Methods: The procedure consists of fusion of the subtalar joint, talonavicular joint and calcaneocuboid joint [1]. The procedure is traditionally done with internal fixation, however, Marinet al. has shown it to be performed with external fixation [2]. Dr. Marin and the associates have developed an alternative technique to perform a triple arthrodesis using internal and external fixation. This paper describes a step-by-step technique to perform a triple arthrodesis with both internal and external fixation. It will demonstrate the use of the prefabricated arches on the footplate for more precise and accurate placement of transosseous wires using arch-wire technique [3]. Results/Conclusion: We believe this technique will not only help increase the ability to achieve fusion with a less chance of non-union, but may also decrease healing time, which may allow patients to be mobile from the first week post-operatively and may diminish the risks associated with being non-weightbearing. 展开更多
关键词 Triple ARTHRODESIS Podiatric Medicine Surgery External fixation internal fixation WALKING TECHNIQUE PODIATRY
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部