Laser ablation coupled with inductively coupled plasma-mass spectrometry (LA-ICP-MS) calibration was conducted with multiple spot analyses on eleven intact rock samples using both an internal standard (IS) method and ...Laser ablation coupled with inductively coupled plasma-mass spectrometry (LA-ICP-MS) calibration was conducted with multiple spot analyses on eleven intact rock samples using both an internal standard (IS) method and a modified constant-sum (MCS) method. Methods were then compared for reported bulk elemental composition of the rocks. The MCS method was based on the sum of eight major elements, which is spatially more stable than one single major ele-ment as used in the IS method, and is quite constant among different rock samples. Calibrations were performed with standard reference materials NIST SRM 610, 612, 614, and 616. Little difference was found between using a single standard and a set of standards, because of the good linearity shown by the reference materials. Comparison of the two calibration methods shows that the MCS method produced better and more stable results than the IS method for heterogeneous samples. With the MCS method, approximately 94% to 95% of the total measurements are within the range of ±100% relative deviation, compared with 82% to 86% with the IS method. The IS method resulted insubstantial overestimations for some rock samples (e.g., 648% for Basalt BCR-2 using NIST SRM 610 as the calibration standard), while the largest deviation with the MCS method was 216% for U in Eagle Ford shale #80 sample. For Quartz latite QLO-1, a relative homogeneous sample, the IS method generated slightly better results than the MCS method. Regardless of method, spatially heterogeneous distribution of elements in the intact rock at the scale of the laser spot is considered to be the main reason for the large relative deviations seen in our work compared to published results.展开更多
The internal standard (IS) method is the best method for the analysis of samples, as it is independent of errors in injection volume, changes in sample volumes, and changes in sensitivity of the detector, etc. Use of ...The internal standard (IS) method is the best method for the analysis of samples, as it is independent of errors in injection volume, changes in sample volumes, and changes in sensitivity of the detector, etc. Use of an internal standard allows for the correction of losses due to sample clean-up of complex samples. An ideal IS is a compound that has properties very similar to, and that behaves as the compounds to be analysed. Ideally, only in the last step of analysis (HPLC), the IS should be well separated from the compounds of the mixture to be analysed. After testing several existing compounds with negative results, we decided to synthesise the 19-O-β-D-galactopyranosyl-13-O-β-D-glucopyranosyl-steviol as IS. This is the 19-galactosyl ester of steviolmonoside (13-O-β-D-glucopyranosyl-steviol). The IS was made according to published methods. Steviolmonoside (SM) was made from purified commercial rubusoside (Rub) by refluxing it in 10% KOH for 2 h. SM was precipitated and crystallized from MeOH. The hydroxyls of the glucose unit of SM were protected by acetylation. The acetylated SM was crystallized from acetone and dissolved in 1,2-dichloroethane. Then Ag2CO3 on Celite and tetra-acetylated galactopyranosyl bromide were added and the mixture was refluxed for 2 h. After cooling, BaO in MeOH was added to remove the acetyl groups. The 1,2-dichloroethane fraction was then extracted three times with equal volumes of water and the water fraction containing the IS was further purified on a C18 flash chromatography column. Traces of unreacted SM were removed by preparative HPLC on an Alltima C18 column (250 mm × 22 mm, particle size 10 μm) with AcCN:water (35:65, 20 ml/min). Detection was at 210 nm (KNAUER, “Smartline” UV detector 2500). The collected IS fraction from the HPLC was completely dried. Mixtures of steviol glycosides (SVglys) containing IS could be purified over SPE cartridges without change of the SVgly over IS ratio. The calibration curves for rebaudioside A (RebA) and stevioside (ST) were linear between 0.012 and 0.95 and between 0.013 and 1.13 mM for RebA and ST, respectively. The accuracy was checked by the standard addition method. It was concluded that the IS method gives an excellent precision and accuracy.展开更多
[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solven...[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.展开更多
Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence ...Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence of bioavailable mercury is an urgent need.The Mer gene is a mercury-responsive resistant gene, and a mercury-sensing recombinant luminescent bacterium using the Mer gene was constructed in this study. The mer operon from marine Pseudomonas putida strain SP1 was amplified and fused with prompterless lux CDABE in the p UCD615 plasmid within Escherichia coli cells, resulting in p THE30–E. coli.The recombinant strain showed high sensitivity and specificity. The detection limit of Hg^2+was 5 nmol/L, and distinct luminescence could be detected in 30 min. Cd^2+, Cu^2+, Zn^2+, Ca^2+,Pb^2+, Mg^2+, Mn^2+, and Al^3+did not interfere with the detection over a range of 10-5–1 m M.Application of recombinant luminescent bacteria testing in environmental samples has been a controversial issue: especially for metal-sensing recombinant strains, false negatives caused by high cytotoxicity are one of the most important issues when applying recombinant luminescent bacteria in biomonitoring of heavy metals. In this study, by establishing an internal standard approach, the false negative problem was overcome;furthermore, the method can also help to estimate the suspected mercury concentration,which ensures high detection sensitivity of bioavailable Hg2+.展开更多
Objective To study the innovative drug pricing methods and medical insurance payment standards in foreign countries and to provide reference for China’s government.Methods The official websites were searched for info...Objective To study the innovative drug pricing methods and medical insurance payment standards in foreign countries and to provide reference for China’s government.Methods The official websites were searched for information and related literature,and literature review was used.Results and Conclusion In foreign countries,the clinical value of innovative drugs and their impact on medical insurance funds were comprehensively evaluated based on factors such as quality-adjusted life years,clinical benefit,and improvement of clinical benefit.Then,the evaluation results were taken as an important basis for whether innovative drugs were admitted to the medical insurance catalog and establishing medical insurance payment standards.By using international experience for reference,innovative drug pricing methods and medical insurance payment standards for China’s national conditions can be improved by establishing a basic database of clinical value and drug economic evaluation of innovative drugs,as well as innovative drug payment models based on decision thresholds.展开更多
Plastic equipment used in cell culture processes contains styrene residues and 2-chloroethanol, a byproduct of ethylene oxide sterilization. Both compounds can have long-term effects on the quality and safety of the c...Plastic equipment used in cell culture processes contains styrene residues and 2-chloroethanol, a byproduct of ethylene oxide sterilization. Both compounds can have long-term effects on the quality and safety of the cells in plastic equipment. GB/T 43778-2024, which establishes a gas chromatography-mass spectrometry(GC-MS) method for the simultaneous detection of st yrene and 2-chloroethanol in cell culture media, includes several technical requirements that need to be thoroughly interpreted. This paper provides a detailed explanation of the internal standard calibration method used for detecting styrene and 2-chloroethanol, covering the overall framework and innovation aspects of the standard. Additionally, it elucidates the principles and rationale of each step, including sample processing, detection parameters, preparation of standard solutions, and the determination of detection and quantification limits, to assist testing technical staff in applying the method effectively.展开更多
为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶...为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。展开更多
文摘Laser ablation coupled with inductively coupled plasma-mass spectrometry (LA-ICP-MS) calibration was conducted with multiple spot analyses on eleven intact rock samples using both an internal standard (IS) method and a modified constant-sum (MCS) method. Methods were then compared for reported bulk elemental composition of the rocks. The MCS method was based on the sum of eight major elements, which is spatially more stable than one single major ele-ment as used in the IS method, and is quite constant among different rock samples. Calibrations were performed with standard reference materials NIST SRM 610, 612, 614, and 616. Little difference was found between using a single standard and a set of standards, because of the good linearity shown by the reference materials. Comparison of the two calibration methods shows that the MCS method produced better and more stable results than the IS method for heterogeneous samples. With the MCS method, approximately 94% to 95% of the total measurements are within the range of ±100% relative deviation, compared with 82% to 86% with the IS method. The IS method resulted insubstantial overestimations for some rock samples (e.g., 648% for Basalt BCR-2 using NIST SRM 610 as the calibration standard), while the largest deviation with the MCS method was 216% for U in Eagle Ford shale #80 sample. For Quartz latite QLO-1, a relative homogeneous sample, the IS method generated slightly better results than the MCS method. Regardless of method, spatially heterogeneous distribution of elements in the intact rock at the scale of the laser spot is considered to be the main reason for the large relative deviations seen in our work compared to published results.
文摘The internal standard (IS) method is the best method for the analysis of samples, as it is independent of errors in injection volume, changes in sample volumes, and changes in sensitivity of the detector, etc. Use of an internal standard allows for the correction of losses due to sample clean-up of complex samples. An ideal IS is a compound that has properties very similar to, and that behaves as the compounds to be analysed. Ideally, only in the last step of analysis (HPLC), the IS should be well separated from the compounds of the mixture to be analysed. After testing several existing compounds with negative results, we decided to synthesise the 19-O-β-D-galactopyranosyl-13-O-β-D-glucopyranosyl-steviol as IS. This is the 19-galactosyl ester of steviolmonoside (13-O-β-D-glucopyranosyl-steviol). The IS was made according to published methods. Steviolmonoside (SM) was made from purified commercial rubusoside (Rub) by refluxing it in 10% KOH for 2 h. SM was precipitated and crystallized from MeOH. The hydroxyls of the glucose unit of SM were protected by acetylation. The acetylated SM was crystallized from acetone and dissolved in 1,2-dichloroethane. Then Ag2CO3 on Celite and tetra-acetylated galactopyranosyl bromide were added and the mixture was refluxed for 2 h. After cooling, BaO in MeOH was added to remove the acetyl groups. The 1,2-dichloroethane fraction was then extracted three times with equal volumes of water and the water fraction containing the IS was further purified on a C18 flash chromatography column. Traces of unreacted SM were removed by preparative HPLC on an Alltima C18 column (250 mm × 22 mm, particle size 10 μm) with AcCN:water (35:65, 20 ml/min). Detection was at 210 nm (KNAUER, “Smartline” UV detector 2500). The collected IS fraction from the HPLC was completely dried. Mixtures of steviol glycosides (SVglys) containing IS could be purified over SPE cartridges without change of the SVgly over IS ratio. The calibration curves for rebaudioside A (RebA) and stevioside (ST) were linear between 0.012 and 0.95 and between 0.013 and 1.13 mM for RebA and ST, respectively. The accuracy was checked by the standard addition method. It was concluded that the IS method gives an excellent precision and accuracy.
文摘[Objective]This study was to establish a rapid,specific and simple method for quantitative determination of tetrachlorantraniliprole by 1H NMR.[Method]1H NMR spectroscopy was acquired with deuterium DMSO as the solvent and maleic acid as internal standard under the conditions of temperature 25℃,pulses width 8.0μs,delay time 5 s,and scanning times 8.[Result]The hydrogen proton peaks of tetrachlorantraniliprole(δ=10.55)and maleic acid(δ=6.27)were taken as quantitative peaks.The peak area ratio y(As/Ar)and mass ratio x(ms/mr)were linearly regressed,and the correlation coefficient was 0.9999.The RSD value of repeatability test was 0.38%,and the RSD value of stability test was 0.77%.The content of tetrachlorantraniliprole was determined as 99.6%.[Conclusion]1H NMR spectroscopy can be used for quantitative determination of tetrachlorantraniliprole without standard reference,which is rapid,accurate and simple.
基金supported by the National Natural Science Foundation of China (No. 21377065)the 863 National High-Tech Research and Development Program (No. 2014AA06A506)
文摘Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence of bioavailable mercury is an urgent need.The Mer gene is a mercury-responsive resistant gene, and a mercury-sensing recombinant luminescent bacterium using the Mer gene was constructed in this study. The mer operon from marine Pseudomonas putida strain SP1 was amplified and fused with prompterless lux CDABE in the p UCD615 plasmid within Escherichia coli cells, resulting in p THE30–E. coli.The recombinant strain showed high sensitivity and specificity. The detection limit of Hg^2+was 5 nmol/L, and distinct luminescence could be detected in 30 min. Cd^2+, Cu^2+, Zn^2+, Ca^2+,Pb^2+, Mg^2+, Mn^2+, and Al^3+did not interfere with the detection over a range of 10-5–1 m M.Application of recombinant luminescent bacteria testing in environmental samples has been a controversial issue: especially for metal-sensing recombinant strains, false negatives caused by high cytotoxicity are one of the most important issues when applying recombinant luminescent bacteria in biomonitoring of heavy metals. In this study, by establishing an internal standard approach, the false negative problem was overcome;furthermore, the method can also help to estimate the suspected mercury concentration,which ensures high detection sensitivity of bioavailable Hg2+.
文摘Objective To study the innovative drug pricing methods and medical insurance payment standards in foreign countries and to provide reference for China’s government.Methods The official websites were searched for information and related literature,and literature review was used.Results and Conclusion In foreign countries,the clinical value of innovative drugs and their impact on medical insurance funds were comprehensively evaluated based on factors such as quality-adjusted life years,clinical benefit,and improvement of clinical benefit.Then,the evaluation results were taken as an important basis for whether innovative drugs were admitted to the medical insurance catalog and establishing medical insurance payment standards.By using international experience for reference,innovative drug pricing methods and medical insurance payment standards for China’s national conditions can be improved by establishing a basic database of clinical value and drug economic evaluation of innovative drugs,as well as innovative drug payment models based on decision thresholds.
基金funded by National Key Research and Development Project (No. 2018YFA0108403)Provincial University Basic Research Operating Expenses Project (No. 21SBYB08)
文摘Plastic equipment used in cell culture processes contains styrene residues and 2-chloroethanol, a byproduct of ethylene oxide sterilization. Both compounds can have long-term effects on the quality and safety of the cells in plastic equipment. GB/T 43778-2024, which establishes a gas chromatography-mass spectrometry(GC-MS) method for the simultaneous detection of st yrene and 2-chloroethanol in cell culture media, includes several technical requirements that need to be thoroughly interpreted. This paper provides a detailed explanation of the internal standard calibration method used for detecting styrene and 2-chloroethanol, covering the overall framework and innovation aspects of the standard. Additionally, it elucidates the principles and rationale of each step, including sample processing, detection parameters, preparation of standard solutions, and the determination of detection and quantification limits, to assist testing technical staff in applying the method effectively.
文摘为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。