期刊文献+
共找到67篇文章
< 1 2 4 >
每页显示 20 50 100
Application of Meridian flow injection acupoint application combined with transcutaneous electrical acupoint stimulation in patients undergoing gastroenteroscopy 被引量:1
1
作者 Xian Hong Xiao-Yan Wu Qing-Li Xu 《World Journal of Gastroenterology》 2025年第36期113-121,共9页
BACKGROUND Although gastroscopy is a commonly used diagnostic and therapeutic technique,postoperative gastrointestinal dysfunction is prone to occur.Traditional Chinese medicine theory suggests that postoperative gast... BACKGROUND Although gastroscopy is a commonly used diagnostic and therapeutic technique,postoperative gastrointestinal dysfunction is prone to occur.Traditional Chinese medicine theory suggests that postoperative gastrointestinal disorders are related to spleen and stomach weakness.This study hypothesizes that the combination of acupoint application at the Ziwu Liuzhu acupoint and percutaneous acupoint electrical stimulation can promote postoperative gastrointestinal function recovery and alleviate stress reactions.AIM To investigate the effects of acupoint application of Ziwu Liuzhu combined with percutaneous acupoint electrical stimulation on postoperative gastrointestinal function recovery and stress response in patients undergoing gastrointestinal endoscopy surgery.METHODS A total of 120 patients who underwent gastroscopy surgery were selected and treated between October 2024 and January 2025.This study used a stratified block randomization method,and then allocated groups using computer-generated random number sequences(SAS 9.4 software).The groups were divided into two groups:A control group of 60 patients who received routine postoperative intervention measures,and an observation group of 60 patients who received acupuncture point application combined with transcutaneous acupoint electrical CONCLUSION The combination of percutaneous acupoint electrical stimulation in gastroscopy patients has been demonstrated to be both highly safe and effective.The benefits of this approach include the promotion of postoperative gastrointestinal function,the reduction of stress response,the attainment of optimal results,and the enhancement of patient satisfaction. 展开更多
关键词 Meridian flow injection acupoint application Acupoint application Transcutaneous electrical acupoint stimulation GASTROSCOPY Gastrointestinal function Stress response
暂未订购
Flow injection chemiluminescence determination of meloxicam using potassium permanganate and formaldehyde system 被引量:1
2
作者 贾宝秀 曹明亮 +3 位作者 刘彩红 李玉琴 李珂 齐永秀 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第1期35-40,共6页
A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium pe... A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h. 展开更多
关键词 MELOXICAM flow injection chemiluminescence FORMALDEHYDE Pharmaceutical analysis
暂未订购
Determination of Gossypol in Trace Level by Flow Injection Analysis with Chemiluminescence Detection 被引量:3
3
作者 Bing Chun XUE Er Bao LIU 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第1期57-60,共4页
This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitiz... This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results. 展开更多
关键词 Single-molecule detection CHEMILUMINESCENCE flow injection gossypol.
暂未订购
The Determination of Iodide Based on a Flow-injection Coupling Irreversible Biamperometry 被引量:3
4
作者 Li Jun LI Hao CHENG +5 位作者 Wen Yi HUANG Hong Xing KONG Jian Ling WU Jian Ping LU Wei GAO Jun Feng SONG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第12期1629-1632,共4页
A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of perm... A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of permanganate at the platinum electrode to form an irreversible biamperometric detection system. Under the applied potential difference of 0 V, in the 0.05 mol/L sulfuric acid, iodidecan be determined over the range 4.00×10^-7-1.00×10^-5 mol/L with a sampling frequency of 120 samples per hour. The detection limit for I- is 3.0×10^-7 mol/L and the RSD for 40 replicate determinations of 4.0×10^-5 mol/L potassium iodide is 1.68%. The new method was applied to the analysis of iodide in table salt with satisfactory results. 展开更多
关键词 IODIDE flow injection irreversible biamperometry gold electrode platinum electrode
在线阅读 下载PDF
Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3
5
作者 Li Jun Li Qi Feng Chen +5 位作者 Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong Jian Ling Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页
A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum elec... A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. 展开更多
关键词 flow injection Irreversible biamperometry Chlorogenic acid HONEYSUCKLE
在线阅读 下载PDF
Flow injection spectrophotometric determination of vitamin E in pharmaceuticals,milk powder and blood serum using potassium ferricyanide-Fe(Ⅲ) detection system 被引量:3
6
作者 Saima Jadoon Amir Waseem +1 位作者 Mohammad Yaqoob Abdul Nabi 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第6期712-715,共4页
A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide redu... A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide reduces.The in situ reduced ions are then reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to make soluble Prussian blue,which is monitored at absorption wavelength of 735 nm.Linear calibration graph was obtained in the concentration range of 0.1-40μg mL^(-1).The relative standard deviations (n=4) were in the range of 1.1-3.6%,with limits of detection(3 s blank) of 0.04μg mL^(-1).The proposed method allowed 12 injections h^(-1).The method is applied to determine vitamin E in pharmaceuticals,infant milk and blood serum samples using hexane extraction with the recoveries in the range of 93±3 to 97.5±4%.The method is validated using certified reference materials SRM 968c for blood serum samples. 展开更多
关键词 flow injection SPECTROPHOTOMETRY Vitamin E Prussian blue FE(III) FERRICYANIDE Pharmaceuticals Blood serum
暂未订购
Study on Chemiluminescence Reactions of L ucigenin and Reductants by Flow Injection Analysis 被引量:1
7
作者 Zhi Jia ZHU Jiu Ru LU (Experimental Center, Hebei Normal University. Shijiazhuang 050016 Department of Chemistry, Shaanxi Normal University, Xian 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第1期61-64,共4页
The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) ... The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) and Fe(III) through a micro Jones column, are studied in detail. Results show that the reactions can be used directly for the determination of these substances. The mechanism of the reactions is also investigated. 展开更多
关键词 reductant LUCIGENIN CHEMILUMINESCENCE flow injection analysis
在线阅读 下载PDF
Reversed flow injection spectrophotometric determination of low residuals of chlorine dioxide in water using chlorophenol red 被引量:1
8
作者 WangGZ ChenH 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2002年第3期423-427,共5页
A novel, simple, rapid, sensitive and highly selective flow injection procedure for the spectrophotometric determination of chlorine dioxide in the presence of other chlorine species, viz,free chlorine, chlorite, chlo... A novel, simple, rapid, sensitive and highly selective flow injection procedure for the spectrophotometric determination of chlorine dioxide in the presence of other chlorine species, viz,free chlorine, chlorite, chlorate and hypochlorite, is developed. The method is based on the discoloration reaction between chlorine dioxide and chlorophenol red and can overcome the shortcomings existed in direct spectrophotometric determination for chlorine dioxide owing to the serious interference of free and combined chlorine. The procedure gave a linear calibration graph over the range 0—0.71 mg/L of chlorine dioxide. With a detection limit of 0.024 mg/L and a sample throughput of 60 samples/h. 展开更多
关键词 chlorine dioxide chlorophenol red reversed flow injection SPECTROPHOTOMETRY
在线阅读 下载PDF
Electropolymerized poly(Toluidine Blue)-modified carbon felt for highly sensitive amperometric determination of NADH in flow injection analysis 被引量:1
9
作者 Yasushi Hasebe Yue Wang Kazuya Fukuoka 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2011年第6期1050-1056,共7页
Poly(pheniothiazine) films were prepared on a porous carbon felt(CF) electrode surface by an electrooxidative polymerization of three phenothiazine derivatives(i.e.,Tthionine(TN),Toluidine Blue(TB) and Methyl... Poly(pheniothiazine) films were prepared on a porous carbon felt(CF) electrode surface by an electrooxidative polymerization of three phenothiazine derivatives(i.e.,Tthionine(TN),Toluidine Blue(TB) and Methylene Blue(MB)) from 0.1 mol/L phosphate buffer solution(pH 7.0).Among the three phenothiazies,the poly(TB) film-modified CF exhibited an excellent electrocatalytic activity for the oxidation of nicotinamide adenine dinucleotide reduced form(NADH) at +0.2 V vs.Ag/AgCl.The poly(TB) film-modified CF was successfully used as working electrode unit of highly sensitive amperometric flow-through detector for NADH.The peak currents(peak heights) were almost unchanged,irrespective of a carrier flow rate ranging from 2.0 to 4.1 mL/min,resulting in the measurement of NADH(ca.30 samples/hr) at 4.1 mL/min.The peak current responses of NADH showed linear relationship over the concentration range from 1 to 30 μmol/L(sensitivity:0.318 μA/(μmol/L);correlation coefficient:0.997).The lower detection limit was found to be 0.3 μmol/L(S/N = 3). 展开更多
关键词 poly(phenothiazine) Toluidine Blue ELECTROPOLYMERIZATION carbon felt NADH flow injection analysis
原文传递
Flow-injection Determination of Cysteine,N-Acetyl Cysteine and Glutathione in Pharmaceuticals via Potassium Ferricyanide-Fe(Ⅲ) Spectrophotometric System 被引量:1
10
作者 WASEEM Amir YAQOOB Mohammad NABI Abdul 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第6期893-898,共6页
A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted wi... A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to form soluble Prussian blue,which is monitored at 735 nm.The calibration graphs are linear in the concentration ranges of(1―100)×10-6 mol/L for cysteine and N-acetyl cysteine,and(1―50)×10-6 mol/L for glutathione.The relative standard deviations of 1.8%,2.5% and 1.9% were found for eleven replicate analyses of 5×10-6 mol/L cysteine,N-acetyl cysteine and glutathione.The limits of detection(3σ blank) at 5×10-7 mol/L for cysteine,and 3×10-7 mol/L for N-acetyl cysteine and glutathione were obtained.The proposed method allowed 60 injections/h.The effects of common substances present in pharmaceuticals and human physiological fluids were examined.The method was applied to determining cysteine in pharmaceutical formulations with the recoveries in a range of 97% to 106% and the results obtained are agreed well with labeled values. 展开更多
关键词 flow injection SPECTROPHOTOMETRY CYSTEINE Prussian blue Fe(Ⅲ) FERRICYANIDE PHARMACEUTICAL
暂未订购
Flow-injection Spectrophotometric Determination of Uric Acid in Urine via Prussian Blue Reaction 被引量:1
11
作者 WASEEM Amir YAQOOB Mohammad +2 位作者 NABI Abdul MURTAZA Ghulam HUSSAIN Izhar 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期929-933,共5页
A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ... A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly. 展开更多
关键词 flow injection analysis SPECTROPHOTOMETRY Uric acid Prussian blue URINE
在线阅读 下载PDF
Flow Injection Chemiluminescence Analysis of Low Level Concentration of Hydrazine 被引量:1
12
作者 Zheng Hua SONG Lin WANG +1 位作者 Ji Hong Lü Tie Zhu ZHAO 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第9期799-802,共4页
Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal pro... Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal produced by the reaction between luminol and hexacyanoferrate (III) in alkaline medium. The decreased CL intensity was linear with hydrazine concentration in the range of 5.0×10-9 g·mL-1 to 4.0×10-5 g·mL-1, and the limit of detection was 2.0×10-9 g·mL-1 (3σ) with a relative standard deviation of 2.4~4.1% (n=5). 展开更多
关键词 HYDRAZINE flow injection CHEMILUMINESCENCE
在线阅读 下载PDF
A Novel Flow Injection Optical Fiber Biosensor for Hypoxanthine Based on Luminol Electrochemiluminescence 被引量:1
13
作者 LI Ying xiu ZHU Lian de ZHU Guo yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2003年第2期240-244,共5页
关键词 ELECTROCHEMILUMINESCENCE flow injection Optical fiber biosensor Sol-gel Ceramic-carbon composite electrode HYPOXANTHINE Fish freshness
在线阅读 下载PDF
Determination of Ciprofloxacin by Flow Injection Analysis Based on Chemiluminescence System 被引量:1
14
作者 张卓勇 李夏 +3 位作者 王小丽 陈世稆 宋保华 赵慧春 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期285-288,共4页
A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence... A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00 × 10^-8 - 9.00 × 10^-7 mol ·L-1 and the detection limit for CPLX is 4.40 × 10^-9 mol·L^-1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110 ± 4 to 104 ± 4. 展开更多
关键词 CIPROFLOXACIN CHEMILUMINESCENCE TERBIUM flow injection KMNO4 Na2S2O4 rare earths
在线阅读 下载PDF
Determination of Trace Non Rare Earth Elements in High Purity Rare Earth Oxides by ICP-AES with Microcolumn Preconcentration in a Flow Injection System 被引量:1
15
作者 吉红念 廖振环 +1 位作者 江祖成 谢金娥 《Journal of Rare Earths》 SCIE EI CAS CSCD 1995年第2期119-124,共6页
A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described ... A new method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate,reagent concentration,length of reaction coil,eluent acidity,etc. were optimized. In the buffer solution of NH3. H2O/NH4Cl at pH 4. 6,Al,Cr,Cu,Fe, Pb, V and Zn can be preconcentrated and then eluted with 4. 5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8. 1 ̄12. 6 with detection limits of μg/m level ,and the RSD with metals at μg/g level were 2. 3 ̄5. 0% (n= 7). The method proposed can reduce the matrix interference effectively , and has been applied to the determination of non-rare earth metals atμg/g level in high purity Eu2O3 with satisfactory results. 展开更多
关键词 flow injection ICP-AES Active carbon-silica gel Sodium diethyldithiocarbamate Stop-flow technique Microcolumn preconcentration High purity Eu_2O_3
在线阅读 下载PDF
On-line Preconcentration and Determination of Trace Metals in Water Samples by Flow Injection Combined with Flame Atomic Absorption Spectrometry via Calix[4]arene Carboxylic Acid Packed Micro-column 被引量:1
16
作者 GUO Da-wang, ZHAO Xiao-wei, JIA Qiong and ZHOU Wei-hong College of Chemistry, Jilin University, Changchun 130012, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第1期26-30,共5页
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determinatio... An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow in jection(FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h–1 was obtained. The limits of de tection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples. 展开更多
关键词 arene carboxylic acid PRECONCENTRATION flow injection Metal ion Flame atomic absorptionspectrometry(FAAS)
在线阅读 下载PDF
Experimental and numerical study of tip injection in a subsonic axial flow compressor 被引量:9
17
作者 Wei WANG Wuli CHU +1 位作者 Haoguang ZHANG Haiyang KUANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2017年第3期907-917,共11页
Parametric study of tip injection was implemented experimentally on a subsonic axial flow compressor to understand the underlying flow mechanisms of stability improvement of the compressor with discrete tip injection.... Parametric study of tip injection was implemented experimentally on a subsonic axial flow compressor to understand the underlying flow mechanisms of stability improvement of the compressor with discrete tip injection.Injector throat height varied from 2 to 6 times the height of rotor tip clearance,and circumferential coverage percentage ranged from 8.3% to 25% of the annulus.Static pressure fluctuations over the rotor tip were measured with fast-response pressure transducers.Whole-passage time-accurate simulations were also carried out to help us understand the flow details.The combinations of tip injection with traditional casing treatments were experimentally studied to generate an engineering-acceptable method of compressor stall control.The results indicate that the maximum stability improvement is achieved when injectors are choked despite their different sizes.The effect of circumferential coverage percentage on compressor stability depends on the value of injector throat height for un-choked injectors,and vice versa.Tip blockage in the blade passage is greatly reduced by the choked injectors,which is the primary reason for stability enhancement.The accomplishment of blockage diminishment is maintained in the circumferential direction with the unsteady effect of tip injection,which manifests as a hysteresis between the recovery of tip blockage and the recovery of tip leakage vortex.The unsteady effect is primarily responsible for the effectiveness of tip injection with a partial circumferential coverage.Tip injection cannot enhance the stability of the rotor with axial slots significantly,but it can improve the stability of the rotor with circumferential grooves further.The combined structure of tip injection with circumferential grooves is an alternative for engineering application. 展开更多
关键词 Axial flow compressor Casing treatments Compressor stability Tip blockage Tip injection Tip leakage vortex
原文传递
Numerical Study on the Effects of Contraction Ratio in a Two-Phase Flow Injection Nozzle 被引量:1
18
作者 Haider Ali Kyung Won Kim +2 位作者 Jae Sik Kim Jong Yun Choi Cheol Woo Park 《Open Journal of Fluid Dynamics》 2016年第1期1-10,共10页
The Euler-Euler numerical method was used to investigate the effects of contraction ratio on twophase flow mixing with mass transfer in the flow injection nozzle. The geometric shape of the nozzle was modified to impr... The Euler-Euler numerical method was used to investigate the effects of contraction ratio on twophase flow mixing with mass transfer in the flow injection nozzle. The geometric shape of the nozzle was modified to improve carbonation efficiency. A gas inlet hole was created to increase the flow mixing of CO2 with water. A nozzle throat was also introduced to increase the gas dissolution by increasing flow rates. Various contraction ratios of nozzle throat, inlet gas and liquid velocities, and gas bubble sizes were employed to determine their effects on gas hold-up, gas concentration, and mass transfer coefficient. Results revealed that the flow injection nozzle with high contraction ratios improved carbonation because of high gas hold-up. Gas concentration was directly related to contraction ratio and gas flow velocities. Carbonation reduced when high liquid velocities and large gas bubbles were employed because of inefficient flow mixing. This study indicated that flow injection nozzle with large contraction ratios were suitable for carbonation because of their ability to increase gas hold-up, gas concentration, and mass transfer coefficient. 展开更多
关键词 flow injection Nozzle Nozzle Throat Contraction Ratio Gas-Liquid flow Mass Transfer
在线阅读 下载PDF
Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer 被引量:1
19
作者 María Carmen Yebra-Biurrun Jesús Manuel Castro-Romero Nieves Carro-Marino 《American Journal of Analytical Chemistry》 2012年第11期755-760,共6页
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac... A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments. 展开更多
关键词 Hexavalent Chromium Flame Atomic Absorption Spectrometry PRECONCENTRATION flow injection Environmental Samples
在线阅读 下载PDF
Kinetic-spectrophotometric determination of free cyanide by stopped-flow reversed flow injection analysis
20
《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第3期367-372,共6页
A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The ... A stopped-flow reversed flow injection method for the determination of free cyanide is proposed. Pyridine-barbituric acid mixture is injected in the flow system as reagent to form the colour species with cyanide. The flow is stopped when the reagent zone comes in the flow cell, where absorbance-time data are collected at 580nm wavelength. The linear range of the determination is 0.1 -10μg/ml CN-. The sampling rate is 60h-1 and the relative standard deviation is 1.6% (n=16) at 5.0 μg/ml CN-1 level. With satisfactory results, the proposed method was applied to the determination of free cyanide in wastewater without sample pretreatment. 展开更多
关键词 kinetic analysis STOPPED-flow reversed flow injection system free cyanide wastewater.
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部