期刊文献+
共找到2,508篇文章
< 1 2 126 >
每页显示 20 50 100
Efficacy of adjunctive systemic or local antibiotic therapy in peri-implantitis:a systematic review and meta-analysis of randomized controlled clinical trials
1
作者 Yifan LU Siqi BAO +2 位作者 Hongke LUO Qianming CHEN Misi SI 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 2025年第2期145-157,共13页
This systematic review and meta-analysis considered the results of randomized controlled clinical trials(RCTs)to evaluate the efficacy of systemic or local antibiotic therapy in peri-implantitis.Two independent author... This systematic review and meta-analysis considered the results of randomized controlled clinical trials(RCTs)to evaluate the efficacy of systemic or local antibiotic therapy in peri-implantitis.Two independent authors screened publications from three electronic databases to include RCTs meeting all the inclusion and exclusion criteria.A meta-analysis was performed to evaluate the weighted mean differences in survival rate(SR)and changes in pocket probing depth(PPD),bone level(BL),and clinical attachment level(CAL).The study cohorts were defined as antibiotic and control groups with subgroups for analysis.Seven studies including 309 patients(390 implants)were considered.Within the limitations of this review,patients in the antibiotic groups exhibited significant improvements in PPD.Subgroup analysis indicated that the administration of systemic antibiotics or the use of antibiotics in non-surgical treatments did not result in a significant alteration in BL.It was established that the addition of antibiotics can ameliorate PPD and SR in the treatment of peri-implantitis,whether through surgical or non-surgical approaches,and also shows moderate performance regarding BL and CAL.Considering the lack of application of new technologies in the control group and the hardship of assessing the potential risks of antibiotics,careful clinical judgment is still necessary. 展开更多
关键词 PERI-implantitis Dental implant Oral medicine MICROBIOLOGY Disease management META-ANALYSIS
原文传递
Biomaterials science and surface engineering strategies for dental peri‑implantitis management
2
作者 Ya-Meng Yu Yu-Pu Lu +3 位作者 Ting Zhang Yu-Feng Zheng Yun-Song Liu Dan-Dan Xia 《Military Medical Research》 2025年第3期354-392,共39页
Peri-implantitis is a bacterial infection that causes soft tissue inflammatory lesions and alveolar bone resorption,ultimately resulting in implant failure.Dental implants for clinical use barely have antibacterial pr... Peri-implantitis is a bacterial infection that causes soft tissue inflammatory lesions and alveolar bone resorption,ultimately resulting in implant failure.Dental implants for clinical use barely have antibacterial properties,and bacterial colonization and biofilm formation on the dental implants are major causes of peri-implantitis.Treatment strategies such as mechanical debridement and antibiotic therapy have been used to remove dental plaque.However,it is particularly important to prevent the occurrence of peri-implantitis rather than treatment.Therefore,the current research spot has focused on improving the antibacterial properties of dental implants,such as the construction of specific micro-nano surface texture,the introduction of diverse functional coatings,or the application of materials with intrinsic antibacterial properties.The aforementioned antibacterial surfaces can be incorporated with bioactive molecules,metallic nanoparticles,or other functional components to further enhance the osteogenic properties and accelerate the healing process.In this review,we summarize the recent developments in biomaterial science and the modification strategies applied to dental implants to inhibit biofilm formation and facilitate bone-implant integration.Furthermore,we summarized the obstacles existing in the process of laboratory research to reach the clinic products,and propose corresponding directions for future developments and research perspectives,so that to provide insights into the rational design and construction of dental implants with the aim to balance antibacterial efficacy,biological safety,and osteogenic property. 展开更多
关键词 PERI-implantitis Dental implant Osteogenic property Antibacterial activity Anaerobic bacteria
原文传递
In vitro antimicrobial effects of grape seed extract on peri-implantitis microflora in craniofacial implants 被引量:1
3
作者 Binit Shrestha M.L.Srithavaj Theerathavaj +1 位作者 Sroisiri Thaweboon Boonyanit Thaweboon 《Asian Pacific Journal of Tropical Biomedicine》 SCIE CAS 2012年第10期822-825,共4页
Objective:To determine the antimicrobial effects of grape seed on peri-implantitis microflora.Methods:The grape seed extract was tested against peri-implantitis microflora most commonly found in craniofacial implants ... Objective:To determine the antimicrobial effects of grape seed on peri-implantitis microflora.Methods:The grape seed extract was tested against peri-implantitis microflora most commonly found in craniofacial implants including reference strains of Staphylococcus aureus(S.aureus),Escherichia coli(E.coli),Candida albicans(C.albicans)and clinical strains of S.aureus,Klebsiella pneumonia(K.pneumonia)and Candida parapsilosis(C.parapsilosis)by disk diffusion test.Minimum inhibitory concentrations(MIC)and minimum cidal concentrations(MCC)were determined using modified agar dilution millpore method.The extract was further combined with polyethylene glycol and propylene glycol,and was tested for antimicrobial effects.Results:Grape seed extract showed positive inhibitory effects with S.aureus at MIC of 0.625 mg/mL and MCC of1.25 mg/mL respectively.However the extracts showed minimal or no reactivity against strains of E.coli,K.pneumonia,C.parapsilosis and C.albicans.The use of grape seed extract in combination with polyethylene glycol and propylene glycol also showed dose dependent inhibitory effect on S.aureus.Conclusions:The results of the study showed that grape seed has potential antimicrobial effects which can be further studied and developed to be used in the treatment of infected skinabutment interface of craniofacial implants. 展开更多
关键词 PERI-implantitis Grape seed extract CRANIOFACIAL IMPLANTS STAPHYLOCOCCUS AUREUS
暂未订购
Maxillary subperiosteal implantitis that caused severe bone resorption of the maxilla with perforation of the maxillary sinus and sinusitis: A case report
4
作者 Kazuki Takaoka Emi Segawa +2 位作者 Kazuma Noguchi Hiromitsu Kishimoto Masahiro Urade 《Open Journal of Stomatology》 2013年第3期226-229,共4页
Subperiosteal implants are generally used in the severely resorbed areas, and although dwindling in use, they have shown to be successful treatment options for the edentulous dental patients. We report a case of maxil... Subperiosteal implants are generally used in the severely resorbed areas, and although dwindling in use, they have shown to be successful treatment options for the edentulous dental patients. We report a case of maxillary subperiosteal implantitis that caused sinusitis. A 59-year-old man was referred to our clinic in March 2003 with a chief complaint of pain and swelling in the bilateral upper molar region. He received a surgical operation for maxillary subperiosteal implant at another dental clinic in April 2001. CT scans demonstrated that the radiopacity of the right maxillary sinus extended to the ethmoid and frontal sinuses. Extensive surgical debridement was performed. The radiopacity of the right maxillary sinus in CT almost disappeared in a month. Two months later, the occlusal function was recovered using a new maxillary complete denture. The patient has had no symptoms and no occlusal disturbance by the denture for more than nine years. 展开更多
关键词 SUBPERIOSTEAL Implant implantitis SINUSITIS
暂未订购
Dental Implant Patients Grouped by the Brinkman Index: Their Attitude toward Smoking, Nicotine Dependence, and Knowledge of Peri-Implantitis
5
作者 Ken Yukawa Noriko Tachikawa Shohei Kasugai 《Open Journal of Regenerative Medicine》 2016年第2期55-60,共6页
Purpose: This study investigated the attitude of patients, grouped by the Brinkman index, towards smoking by using the Kano Test for Social Nicotine Dependence (KTSND) and their knowledge of peri-implantitis. Methods:... Purpose: This study investigated the attitude of patients, grouped by the Brinkman index, towards smoking by using the Kano Test for Social Nicotine Dependence (KTSND) and their knowledge of peri-implantitis. Methods: The participants were 3093 new patients who visited the Tokyo Medical and Dental University Hospital from January 2012 to December 2013 for an oral implant. The methodology included a questionnaire about sex, age, smoking status, daily average number of cigarettes, years of smoking, knowledge of peri-implantitis, and the KTSND. The patients were grouped according to their smoking status by calculating their Brinkman index (over 200 or not): current smokers with the possibility of nicotine dependence (BI(+)CS), current smokers with no possibility of nicotine dependence (BI(-)CS), ex-smokers (ES), and non-smokers (NS). The Brinkman index is obtained by multiplying one’s daily average number of cigarettes by the number of years they have been smoking. Results: Data were collected from 2182 respondents (response rate = 71%). The KTSND scores of BI(+)CS (16.89 ± 4.26) were significantly higher than the scores of ES (11.99 ± 4.52) and NS (11.53 ± 5.01). In current smokers, there were no significant differences between BI(+)CS and BI(-)CS. The patients replied “I don’t know” about peri-implantitis most often in all groups;however, there were no significant differences between the groups. Discussion: BI(+)CS were more dependent on nicotine in social situations than the other groups were. In Japan, a Brinkman index over 200 is required for a nicotine-dependence management fee to be instituted for health insurance treatment. This is a major concern for young smokers, who may be excluded from treatment because their years of smoking are substantially less. Results revealed that there were no significant differences between BI(+)CS and BI(-)CS. Therefore, it was suggested that the Brinkman index did not sufficiently group the participants. 展开更多
关键词 Dental Implant PERI-implantitis SMOKING Smoking Cessation Kano Test for Social Nicotine Dependence (KTSND)
暂未订购
Next-generation craniomaxillofacial implants for reconstructive surgery: balancing biomechanics,biocompatibility,and bioactivity
6
作者 Bozhi Hou Yuehua Li Raymond Chung Wen Wong 《International Journal of Oral Science》 2026年第1期1-17,共17页
Next-generation craniomaxillofacial implants(CMFIs) are redefining personalized bone reconstruction by balancing and optimizing biomechanics,biocompatibility,and bioactivity—the "3Bs".This review highlights... Next-generation craniomaxillofacial implants(CMFIs) are redefining personalized bone reconstruction by balancing and optimizing biomechanics,biocompatibility,and bioactivity—the "3Bs".This review highlights recent progress in implant design,material development,additive manufacturing,and preclinical evaluation.Emerging biomaterials,including bioresorbable polymers,magnesium alloys,and composites with bioactive ceramics,enable patient-specific solutions with improved safety and functionality.Triply periodic minimal surface(TPMS) architectures exemplify how structural design can enhance both mechanical performance and biological integration.Additive manufacturing technologies further allow the fabrication of geometrically complex,customized impla nts that meet individual anatomical and pathological needs.In parallel,multiscale evaluation techniques—from mechanical testing to in vitro and in vivo models—provide comprehensive insights into implant performance and safety.Looking ahead,the field is poised to benefit from several transformative trends:the development of smart and multifunctional biomaterials;Al-driven design frameworks that leverage patient-specific data and computational modeling;predictive additive manufacturing with real-time quality control;and advanced biological testing platforms for preclinical evaluation.Together,these advances form the foundation of a data-informed,translational pipeline from bench to bedside.Realizing the full potential of nextgene ration CMFIs will require close interdisciplina ry collaboration across mate rials science,computational engineering,and clinical medicine. 展开更多
关键词 bioresorbable polymersmagnesium alloysand BIOCOMPATIBILITY next generation craniomaxillofacial implants craniomaxillofacial implants cmfis periodic mini balancing optimizing BIOMECHANICS bioactive ceramicsenable
暂未订购
Research on the Application of Digital Intraoral Scanning Impression Technique in Oral Implant Restoration for Periodontitis Patients and Its Impact on VAS Scores
7
作者 Fei Chen Jingke Liu 《Journal of Clinical and Nursing Research》 2026年第1期61-67,共7页
Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)score... Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)scores.Methods:A total of 80 periodontitis patients who received implant restoration in our hospital from May 2023 to May 2025 were selected as research subjects.They were randomly divided into an observation group and a control group using a random number table method,with 40 cases in each group.The observation group used the digital intraoral scanning impression technique to obtain impressions,while the control group used the traditional silicone rubber impression technique.The impression-taking time,the number of prostheses try-ins,implant survival rate,periodontal health indicators(probing depth,gingival index,bleeding index),and VAS scores(pain during treatment and comfort after restoration)were compared between the two groups.Results:The observation group was superior to the control group in terms of impression-taking time,the number of prostheses try-ins,and implant survival rate(p<0.05).Six months after restoration,the improvement in periodontal health indicators in the observation group was significantly better than that in the control group(p<0.05).In addition,the pain VAS score of the observation group during treatment was lower than that of the control group,and the comfort VAS score after restoration was higher than that of the control group(p<0.05).Conclusion:Digital intraoral scanning impression technology can effectively enhance the efficiency and success rate of implant restoration in periodontitis patients,improve periodontal health,alleviate patients’discomfort during treatment,and increase post-restoration comfort,demonstrating high clinical application value. 展开更多
关键词 Digital intraoral scanning impression technology PERIODONTITIS Oral implant restoration Visual analog scale Implant survival rate
暂未订购
Comparing clinical performance of two-rod levonorgestrel implants across brands:A three-year multicenter randomized clinical trial on Sinoplant and Indoplant
8
作者 Djaswadi Dasuki Hendy Hendarto +11 位作者 Delfi Lutan Muhammad N.Rahman Muhammad O.Prabudi Indra G.Munthe Jimmy Y.Annas Shinta Prawitasari Muhammad Lutfi Sarrah Ayuandari Endah Rahmawati Arif Tunjungseto Adi Ariffianto Irfan Haris 《Asian pacific Journal of Reproduction》 2026年第1期2-10,共9页
Objective:To compare the effectiveness,safety,acceptability,and confounding factors of the two-rod levonorgestrel implants between the Indoplant and Sinoplant implant brands.Methods:The study was a double-blind,random... Objective:To compare the effectiveness,safety,acceptability,and confounding factors of the two-rod levonorgestrel implants between the Indoplant and Sinoplant implant brands.Methods:The study was a double-blind,randomized controlled trial at three different centers in Indonesia.A total of 531 participants that met inclusion and exclusion criteria were randomized into two groups,with 264 participants in the Sinoplant group and 267 participants in the Indoplant group.At each center,participants were divided into two groups for Sinoplant and Indoplant.The participants were followed up for 36 months.Four parameters were evaluated:implant effectiveness,safety,acceptability,and confounding factors.Results:A total of 531 eligible participants were enrolled in this study.Both Sinoplant and Indoplant showed 100%efficacy in preventing pregnancy,with no significant differences in side effects.24.22%of the Sinoplant group and 22.18%of the Indoplant group reported weight changes.8.60%of the Sinoplant group and 9.73%of the Indoplant group reported menstrual changes,and 1.17%of the both groups experienced intermenstrual bleeding.Implant acceptability was 96.61%,with 3.39%dropout rates.Confounding factors such as age,parity,and contraceptive history did not significantly differ between the two groups.Conclusions:Sinoplant and Indoplant did not differ significantly in contraceptive effectiveness,safety,acceptability,and confounding factors. 展开更多
关键词 CONTRACEPTIVES IMPLANTS LEVONORGESTREL Effectiveness ACCEPTABILITY Side effects
暂未订购
Intraoperative Impedance Gradient as a Physiological Indicator of Electrode-Neural Interface in Pediatric Cochlear Implantation
9
作者 Richi Sinha Maruti Nandan +1 位作者 Amit Kumar Sharma Rakesh Kumar Singh 《Journal of Otology》 2026年第1期16-21,共6页
Objective:To investigate the spatial gradient of intraoperative impedance across the cochlear electrode array in pediatric cochlear implant recipients and assess its potential as a physiological indicator for the elec... Objective:To investigate the spatial gradient of intraoperative impedance across the cochlear electrode array in pediatric cochlear implant recipients and assess its potential as a physiological indicator for the electrode-neural interface.Methods:A prospective observational study involving 56 pediatric patients underwent cochlear implantation with Cochlear Nucleus devices.Intraoperative polarized impedance and electrically evoked compound action potential(ECAP)threshold were recorded across all 1232 electrodes using AutoNRT software.Eight electrodes with open-or short-circuit were excluded,leaving 1,224 for analysis.Impedance values were categorized by cochlear region(basal,middle,apical),and electrodes with elevated impedance(10-20 kΩ)were analyzed for regional distribution and clinical relevance.Data were analyzed for spatial patterns and correlation with the ECAP threshold profiles.Results:A consistent basal-to-apical increase in impedance was observed(7.7±1.9,9.2±1.4,10.8±1.5 kΩ;p<0.001).Impedance and ECAP threshold were weakly correlated(ρ=-0.20,p<0.001;β=-1.26,p<0.001),with a positive association in the apical region(ρ=0.12,p=0.048).Electrodes with higher impedance(1020 kΩ)were less likely to show elevated or absent TNRT(OR=0.175,p=0.02).The impedance gradient persisted across age groups and was significantly correlated with ECAP threshold patterns.Conclusion:Intraoperative impedance monitoring reveals a strong and physiologically consistent gradient,with higher values in apical electrodes.This gradient reflects anatomical and tissue interface variations,which may offer a valuable physiological indicator for intraoperative electrode positioning and neural interface integrity. 展开更多
关键词 Cochlear Implant IMPEDANCE ECAP Neural Response Telemetry Electrode Array Physiological Indicator
暂未订购
Prolonged survival and risk factors for reintervention after inflatable penile prosthesis implantation
10
作者 Skander Zouari Flora Barthe +7 位作者 Arnoult Morrone Lionel Mendel Imad Bentellis Louis Vignot Romain Haider Younes Ahallal Daniel Chevallier Matthieu Durand 《The Canadian Journal of Urology》 2026年第1期173-184,共12页
Background:Inflatable Penile Prosthesis(IPP)is the treatment for erectile dysfunction(ED)refractory to pharmacological therapies.Long-term data on factors associated with prosthesis survival remain unclear.This study ... Background:Inflatable Penile Prosthesis(IPP)is the treatment for erectile dysfunction(ED)refractory to pharmacological therapies.Long-term data on factors associated with prosthesis survival remain unclear.This study aimed to analyze the long-term survival of penile prostheses and identify risk factors associated with survival without reintervention.Methods:This is a retrospective,single-center study of patients who underwent IPP implantation between January 2014 and December 2022.Preoperative data related to the patient and the etiology of ED,as well as perioperative data,were collected.The primary outcome was survival without reintervention,defined as prosthesis revision or explantation due to mechanical dysfunction or infection.We conducted survival analyses without reintervention and searched for risk factors using a multivariate Cox model.Results:In total,33 out of 137 patients underwent reintervention(24.1%),including 24(17.5%)prosthesis revisions and 9(6.6%)had explantations.Median follow-up was 39 months with an interquartile range(IQR)of 9.00 to 62.00.Median survival without reintervention was 7 years.In univariate analysis,downsizing(p=0.046)was associated with reintervention.Smoking(p=0.003)and age(p=0.034)were associated with prosthesis explantation.The number of implantations(p=0.009)was associated with prosthesis revision.Multivariate analysis by the Cox model did not identify any independent predictive factors for reintervention.Conclusion:Smoking may play a role in infection post-IPP implantation.Primary implantations seem to be associated with better survival.Adjusting cylinder size,known as downsizing,is likely to be a proxy for the complexity of the procedure and thus linked to earlier reintervention. 展开更多
关键词 erectile dysfunction mechanical dysfunction implant survival inflatable penile prosthesis long-term follow-up surgical reoperation
暂未订购
Management of coexisting cataract and diabetic macular edema:a comparative study of dexamethasone implant versus anti-VEGF agents injections
11
作者 Aditya Kelkar Jai Kelkar +3 位作者 Subhasree Dutta Mounika Bolisetty Harsh Jain Nikhil Labhsetwar 《International Journal of Ophthalmology(English edition)》 2026年第1期56-62,共7页
AIM:To compare the anatomical and functional outcomes of combined phacoemulsification with intravitreal dexamethasone implant(DEX-I)versus anti-vascular endothelial growth factor(VEGF)injections in patients with diabe... AIM:To compare the anatomical and functional outcomes of combined phacoemulsification with intravitreal dexamethasone implant(DEX-I)versus anti-vascular endothelial growth factor(VEGF)injections in patients with diabetic macular edema(DME)and visually significant cataract.METHODS:This nonrandomized,retrospective analysis included 54 eyes undergoing phacoemulsification with DEX-I(DEX-I group)and 47 eyes receiving anti-VEGF injections(anti-VEGF group).Best-corrected visual acuity(BCVA)and central macular thickness(CMT)were measured preoperatively and postoperatively at 1 and 3mo.RESULTS:The two groups had comparable baseline characteristics,with similar age(DEX-I:66.83±7.27y;anti-VEGF:66.81±6.79y)and gender distribution(51.9%vs 59.6%males).Both groups showed significant BCVA improvement at 1 and 3mo,with no significant intergroup differences.CMT reduction was significantly greater in the DEX-I group at 3mo(25.03%vs 14.07%;P=0.049),particularly in recalcitrant eyes(25.09%vs 11.10%;P=0.007).Postoperative intraocular pressure(IOP)>21 mm Hg was observed in 14.8%of DEX-I eyes and 4.25%of anti-VEGF eyes(P=0.08),normalizing by 3mo.DEX-I required no reinjection,while 29.79%of anti-VEGF eyes needed a fourth dose at 3mo.Complications were minimal,with one posterior capsular injury in the DEX-I group.CONCLUSION:Combined phacoemulsification with intravitreal DEX-I offers superior CMT reduction and comparable visual acuity improvement to anti-VEGF injections in DME,with fewer required treatments.It is an effective strategy for managing cataract with DME,offering benefits,especially for recalcitrant cases.Both therapies have favourable safety profiles,but further long-term studies are needed for clinical guidance. 展开更多
关键词 dexamethasone implant anti-vascular endothelial growth factor diabetic macular edema CATARACT
原文传递
Inner Ear Malformations with Transitional Forms between Cochlear Hypoplasia and Common Cavity:Embryological Insights,Imaging Characteristics,and Cochlear Implantation Strategies
12
作者 Shujin Xue Xingmei Wei +4 位作者 Ying Kong Zhencheng Gao Biao Chen Danmo Cui Yongxin Li 《Journal of Otology》 2026年第1期50-56,共7页
Objectives:To investigate the imaging characteristics,surgical approaches,and outcomes of cochlear implantation(CI)in patients with special inner ear malformations(IEMs)that show transitional forms between cochlear hy... Objectives:To investigate the imaging characteristics,surgical approaches,and outcomes of cochlear implantation(CI)in patients with special inner ear malformations(IEMs)that show transitional forms between cochlear hypoplasia(CH)and common cavity(CC).Methods:Twelve children(eight males,four females),aged 10 to 43 months,with special IEMs were enrolled,and their inner ear structures were analyzed using detailed segmentation.Two surgical approaches were employed:the transmastoid slot labyrinthotomy approach(TSLA)for cases requiring customized electrodes,and the round window or cochleostomy approach for the remaining cases.Outcomes were evaluated using Categories of Auditory Performance(CAP),Speech Intelligibility Rating(SIR),and Meaningful Auditory Integration Scale(MAIS/IT-MAIS)at 12 months post-implantation.Results:Two main types of malformed cochleae were identified:common cavity-like and primitive CH types.All patients exhibited cochlear nerve deficiency and significant bilateral differences in their inner ear structures.Four patients underwent TSLA with customized electrodes,while the remaining patients received lateral wall electrodes via the round window or cochleostomy approach.Most patients showed improvement in auditory and speech capabilities following implantation.Conclusion:Inner ear malformations with transitional forms between CH and CC present unique challenges,requiring detailed preoperative evaluation and customized surgical plans.Even in severe cases,carefully planned surgery can lead to meaningful auditory rehabilitation. 展开更多
关键词 Cochlear implantation Inner ear malformation Temporal bone CT
暂未订购
Comparison of three different instruments for vault measurements after implantable collamer lens implantation
13
作者 Bo-Liang Li Ming-Rui Cheng +6 位作者 Wei-Teng Chang Ya-Di Lei Guang-Han Xu Ming-Wei Li Zhi-Wei Mao Xun Chen Xiao-Ying Wang 《International Journal of Ophthalmology(English edition)》 2026年第3期475-482,共8页
AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)follow... AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly. 展开更多
关键词 implantable collamer lens vault measurement scheimpflug tomography anterior segment optical coherence tomography ultrasound biomicroscopy measurement consistency
原文传递
Comparison of visual outcomes between bilateral EDOF IOL implantation and combined EDOF and bifocal IOL implantation
14
作者 Jia-Yan Fang Jing Jin +4 位作者 Yi-Ling Jiang Fu-Man Yang Ping-Jun Chang Yin-Ying Zhao Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 2026年第2期266-272,共7页
AIM:To compare the visual outcomes between bilateral implantation of Tecnis ZXR00 extended depth-of-focus(EDOF)intraocular lenses(IOLs)and mixed implantation of Tecnis ZXR00(EDOF)with Tecnis ZMB00(bifocal)IOLs.METHODS... AIM:To compare the visual outcomes between bilateral implantation of Tecnis ZXR00 extended depth-of-focus(EDOF)intraocular lenses(IOLs)and mixed implantation of Tecnis ZXR00(EDOF)with Tecnis ZMB00(bifocal)IOLs.METHODS:This postoperative cross-sectional study enrolled patients who underwent phacoemulsification combined with IOL implantation.Patients were divided into two groups:the bilateral ZXR00 group(ZXR00-only group)and the mixed IOL group(ZXR00+ZMB00 group).Primary outcome measures included uncorrected and corrected distance visual acuity(UDVA,CDVA),uncorrected and distance-corrected near visual acuity(UNVA,DCNVA),uncorrected and distance-corrected intermediate visual acuity(UIVA,DCIVA),and defocus curves.Secondary outcome measures were visual quality,spectacle independence,patient satisfaction,photic phenomena,and stereopsis.RESULTS:A total of 47 patients(94 eyes)were included,with 26 patients(11 males,15 females)in the ZXR00-only group(mean age:62.73±7.24y)and 21 patients(7 males,14 females)in the mixed group(mean age:65.71±9.16y).There was no statistically significant difference in age between the two groups(P=0.218).The mixed group showed significantly better binocular DCNVA compared to the ZXR00-only group(P=0.002).Defocus curve analysis revealed that the mixed group exhibited superior performance at−2.5 to−4.0 D but inferior performance at−0.5 and−1.5 D.Near stereoacuity was significantly poorer in the mixed group(Randot:5.589±0.744 vs 6.240±0.394 ln arcsec;Contour:4.966±0.973 vs 5.740±0.833 ln arcsec;both P<0.01).Both groups achieved high levels of spectacle independence and patient satisfaction,with no significant differences in photic phenomena or questionnaire scores.CONCLUSION:Mixed implantation of EDOF and bifocal IOLs improve near visual acuity but may compromise near stereopsis.This approach provides a viable option for patients prioritizing near vision;however,caution is recommended for individuals requiring fine stereoscopic vision for daily or professional tasks. 展开更多
关键词 extended depth-of-focus intraocular lens bifocal intraocular lens mixed intraocular lens implantation near visual acuity STEREOPSIS visual quality
原文传递
Wen Yang Hua Zhuo formula facilitates embryo implantation by modulating endometrial immune metabolic microenvironment via the MCT/HIF-1α/LDHA pathway
15
作者 Xin Wen Xiao-Li Zhao +2 位作者 Zhen Dou Rong Dong Tian Xia 《Traditional Medicine Research》 2026年第5期14-26,共13页
Background:Chronic endometritis(CE)is an important pathological factor contributing to female infertility and recurrent pregnancy loss.Although antibiotics are the primary clinical treatment for CE,they do not effecti... Background:Chronic endometritis(CE)is an important pathological factor contributing to female infertility and recurrent pregnancy loss.Although antibiotics are the primary clinical treatment for CE,they do not effectively improve pregnancy outcomes.Wen Yang Hua Zhuo(WYHZ)is a clinically employed classical formula known for its effects in warming yang,tonifying the spleen and kidneys,and resolving dampness.However,its underlying mechanisms remain unclear.This study aimed to elucidate how WYHZ modulates the immunometabolic microenvironment at the maternal-fetal interface in CE by targeting the MCT/HIF-1α/LDHA pathway to promote embryo implantation.Methods:In vivo,the model of CE was established by intrauterine injection of lipopolysaccharide(LPS)(1 mg/mL)into female C57/BL mice,followed by WYHZ treatment for 3 weeks to evaluate its effects on embryo implantation.Mechanistic studies were further conducted using the MCT-1 inhibitor AZD3965 and adeno-associated virus-mediated HIF-1αknockdown.In vitro,an in vitro CE model consisting of M1 macrophages and Ishikawa,as well as an in vitro embryo implantation model mediated by JAR cells,were constructed using Transwell,and the therapeutic mechanisms of WYHZ was validated using AZD3965 and lentiviral sh HIF-1αintervention.Metabolic enzyme activity assays,protein antibody microarrays,immunofluorescence,Western blotting,Seahorse analysis,and ELISA were employed.Results:WYHZ improved the immune-inflammatory microenvironment at the maternal-fetal interface by reducing pro-inflammatory cytokines and increasing anti-inflammatory factors.In parallel,WYHZ reprogrammed endometrial metabolism by enhancing glycolysis and suppressing mitochondrial oxidative phosphorylation,thereby improving endometrial receptivity and embryo implantation.Mechanistically,WYHZ activated the MCT/HIF-1α/LDHA pathway in endometrial epithelial cells,alleviating inflammatory stress and restoring receptivity.Both AZD3965 intervention and HIF-1αknockdown impaired endometrial receptivity and implantation,effects that were reversed by WYHZ.Conclusion:WYHZ modulates the immunometabolic microenvironment of the endometrium in the context of CE by targeting the activation of the MCT/HIF-1α/LDHA pathway,which improves endometrial receptivity and promotes embryo implantation. 展开更多
关键词 chronic endometritis traditional Chinese medicine embryo implantation immunometabolic microenvironment MCT/HIF-1α/LDHA pathway
暂未订购
Gamma entrainment as a functional target in deep brain stimulation
16
作者 Bandy Chen 《Neural Regeneration Research》 2026年第7期2918-2919,共2页
Deep brain sti mulation(DBS)is a neuromodulation tool that involves the delivery of electrical impulses to specific brain regions through implanted electrodes.The principle behind DBS is to modulate dysfunctional neur... Deep brain sti mulation(DBS)is a neuromodulation tool that involves the delivery of electrical impulses to specific brain regions through implanted electrodes.The principle behind DBS is to modulate dysfunctional neural circuits without the need for permanent structural alterations to the brain.Initially developed as a treatment for movement disorders such as Parkinson's disease(PD),DBS has expanded to encompass various neurological and psychiatric disorders. 展开更多
关键词 modulate dysfunctional neural circuits deep brain sti mulation dbs neuromodulation tool implanted electrodesthe delivery electrical impulses specific brain regions gamma entrainment neurological psychiatric disorders movement disorders
暂未订购
Community dynamics during de novo colonization of the nascent peri-implant sulcus 被引量:1
17
作者 Tamires Pereira Dutra Nicolas Robitaille +2 位作者 Khaled Altabtbaei Shareef M.Dabdoub Purnima S.Kumar 《International Journal of Oral Science》 2025年第3期361-367,共7页
Dental implants have restored masticatory function to over 100000000 individuals,yet almost 1000000 implants fail each year due to peri-implantitis,a disease triggered by peri-implant microbial dysbiosis.Our ability t... Dental implants have restored masticatory function to over 100000000 individuals,yet almost 1000000 implants fail each year due to peri-implantitis,a disease triggered by peri-implant microbial dysbiosis.Our ability to prevent and treat peri-implantitis is hampered by a paucity of knowledge of how these biomes are acquired and the factors that engender normobiosis.Therefore,we combined a 3-month interventional study of 15 systemically and periodontally healthy adults with whole genome sequencing,finescale enumeration and graph theoretics to interrogate colonization dynamics in the pristine peri-implant sulcus.We discovered that colonization trajectories of implants differ substantially from adjoining teeth in acquisition of new members and development of functional synergies.Source-tracking algorithms revealed that this niche is initially seeded by bacteria trapped within the coverscrew chamber during implant placement.These pioneer species stably colonize the microbiome and exert a sustained influence on the ecosystem by serving as anchors of influential hubs and by providing functions that enable cell replication and biofilm maturation.Unlike the periodontal microbiome,recruitment of new members to the peri-implant community occurs on nepotistic principles.Maturation is accompanied by a progressive increase in anaerobiosis,however,the predominant functionalities are oxygen-dependent over the 12-weeks.The peri-implant community is easily perturbed following crown placement,but demonstrates remarkable resilience;returning to pre-perturbation states within three weeks.This study highlights important differences in the development of the periodontal and peri-implant ecosystems,and signposts the importance of placing implants in periodontally healthy individuals or following the successful resolution of periodontal disease. 展开更多
关键词 whole genome sequencingfinescale enu masticatory function microbial dysbiosis de novo colonization peri implantitis dental implants peri implant sulcus whole genome sequencing
暂未订购
Flexible Graphene Field‑Effect Transistors and Their Application in Flexible Biomedical Sensing 被引量:1
18
作者 Mingyuan Sun Shuai Wang +5 位作者 Yanbo Liang Chao Wang Yunhong Zhang Hong Liu Yu Zhang Lin Han 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期252-313,共62页
Flexible electronics are transforming our lives by making daily activities more convenient.Central to this innovation are field-effect transistors(FETs),valued for their efficient signal processing,nanoscale fabricati... Flexible electronics are transforming our lives by making daily activities more convenient.Central to this innovation are field-effect transistors(FETs),valued for their efficient signal processing,nanoscale fabrication,low-power consumption,fast response times,and versatility.Graphene,known for its exceptional mechanical properties,high electron mobility,and biocompatibility,is an ideal material for FET channels and sensors.The combination of graphene and FETs has given rise to flexible graphene field-effect transistors(FGFETs),driving significant advances in flexible electronics and sparked a strong interest in flexible biomedical sensors.Here,we first provide a brief overview of the basic structure,operating mechanism,and evaluation parameters of FGFETs,and delve into their material selection and patterning techniques.The ability of FGFETs to sense strains and biomolecular charges opens up diverse application possibilities.We specifically analyze the latest strategies for integrating FGFETs into wearable and implantable flexible biomedical sensors,focusing on the key aspects of constructing high-quality flexible biomedical sensors.Finally,we discuss the current challenges and prospects of FGFETs and their applications in biomedical sensors.This review will provide valuable insights and inspiration for ongoing research to improve the quality of FGFETs and broaden their application prospects in flexible biomedical sensing. 展开更多
关键词 FLEXIBLE GRAPHENE Field-effect transistor WEARABLE IMPLANTABLE BIOSENSOR
在线阅读 下载PDF
Geriatric assessment for predicting outcomes among patients with aortic stenosis undergoing transcatheter aortic valve implantation 被引量:1
19
作者 Calvo E Castillo P +10 位作者 Romaguera R Llaó I Zafrilla R Domene G Alegre O Lorente V Muntané-Carol G Formiga F de la Cuerda FJ Gomez Hospital JA Ariza-Solè A 《Journal of Geriatric Cardiology》 2025年第5期516-524,共9页
Background There is scarce data about comparisons between geriatric assessment tools in patients with aortic stenosis(AS).We aimed to describe the geriatric profile of patients with AS undergoing transcatheter aortic ... Background There is scarce data about comparisons between geriatric assessment tools in patients with aortic stenosis(AS).We aimed to describe the geriatric profile of patients with AS undergoing transcatheter aortic valve implantation(TAVI)and to analyze the ability of different tools for predicting clinical outcomes in this context.Methods This was a single center retrospective registry including patients with AS undergoing TAVI and surviving to hospital discharge.The primary endpoint was all-cause mortality or need for urgent readmission one year after TAVI.Results A total of 377 patients were included(mean age of 80.4 years).Most patients were independent or mildly dependent,with an optimal cognitive status.The proportion of frailty ranged from 17.6%to 49.8%.A total of 20 patients(5.3%)died and 110/377 patients(29.2%)died or were readmitted during follow up.Overall,most components of the geriatric assessment showed an association with clinical outcomes.Disability for instrumental activities showed a significant association with mortality and a strong association with the rate of mortality or readmission.The association between frailty and clinical outcomes was higher for short physical performance battery(SPPB),essential frailty toolset(EFT)and the frailty index based on comprehensive geriatric assessment(IF-VIG)and lower for Fried criteria and FRAIL scale.Conclusions AS patients from this series presented a good physical performance,optimal cognitive status and a reasonably low prevalence of frailty.The best predictive ability was observed for disability for instrumental activities and frailty as measured by the EFT,SPPB and the IF-VIG. 展开更多
关键词 transcatheter aortic valve implantation tavi analyze ability different tools Geriatric Assessment describe geriatric profile geriatric assessment tools Transcatheter Aortic Valve Implantation FRAILTY Aortic Stenosis
暂未订购
Effects of metal ion implantation(Fe,Ti,Zn and Zr)on mechanical properties,corrosion resistance and biocompatibility of WE43 Mg alloy 被引量:1
20
作者 Lianhui Li Zhiqiang Zhang +4 位作者 Dechuang Zhang Fugang Qi Yilong Dai Wenwen Wei Xiaoping Ouyang 《Journal of Magnesium and Alloys》 2025年第1期296-310,共15页
To improve the corrosion resistance of biodegradable Mg alloys,WE43 alloys were implanted with Fe,Ti,Zn and Zr ions at the same implantation dose.The surface morphology,valence state of elements,nano-hardness(NH),elas... To improve the corrosion resistance of biodegradable Mg alloys,WE43 alloys were implanted with Fe,Ti,Zn and Zr ions at the same implantation dose.The surface morphology,valence state of elements,nano-hardness(NH),elastic modulus(EM),degradation rate and in vitro cell experiments of the modified WE43 alloys were systematically studied.A modified layer composed of Mg,MgO,the implanted elements and their oxides was formed on the modified alloys.Since high-speed metal ions caused severe surface lattice damage,the surface hardness of the substrate considerable increased.Electrochemical tests demonstrated a substantial enhancement in the corrosion resistance of the modified alloys via the implantation of Ti and Zr ions,resulting in a reduction of the corrosion current density to 88.1±9.9 and 15.6±11.4μA cm^(−2),respectively,compared with the implantation of Fe and Zn ions.Biocompatibility tests showed that the implantation of Fe,Ti,Zn and Zr ions enhanced the anticoagulant and hemolytic resistance of the WE43 alloy.All surface-modified samples showed negligible cytotoxicity(0-1)at 12.5%extract concentration.Moreover,the alloys implanted with Fe,Ti and Zn ions significantly promoted proliferation of human umbilical vein endothelial cells(HUVEC)compared with the unmodified alloy.The results demonstrate that Ti ion implantation is the best choice for WE43 alloy modification to achieve outstanding corrosion resistance and biocompatibility. 展开更多
关键词 Biomaterial Ion implantation Surface mechanical properties Corrosion rate BIOCOMPATIBILITY
在线阅读 下载PDF
上一页 1 2 126 下一页 到第
使用帮助 返回顶部