Out-of-step oscillation separation devices based on apparent impedance angle trajectory are widely used in the power grid in China,and their reliability is of great importance.In this paper,the influence mechanism of ...Out-of-step oscillation separation devices based on apparent impedance angle trajectory are widely used in the power grid in China,and their reliability is of great importance.In this paper,the influence mechanism of series compensation on apparent impedance angle trajectory is analyzed.It reveals that series compensation capacitors reduce the equivalent impedance angle and consequently the apparent impedance angle cannot pass through all four zones,resulting in the risk of failure for the separation devices.A revised method of apparent impedance angle based on compensation principle is discussed,and then an improved out-of-step oscillation detection criterion is proposed.In view of the fact that the apparent impedance angle at the moment of maximum current is equal to the equivalent impedance angle during an oscillation process,a practical algorithm based on the compensated apparent impedance angle is proposed.RTDS tests are conducted to verify the effectiveness of the new criterion,considering transmission lines with a high series compensation level.展开更多
With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the in...With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument with high reliability which can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogowski coil sensor for better leakage current signal. To avoid the fluctuation from railway power supply,four modules are set to filter the power supply waveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation when leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator.展开更多
基金supported by the science and technology project of State Grid Corporation of China (Security Protection Technology of Embedded Components and Control Units in Power System Terminal,No.5100-201941446A-0-0-00).
文摘Out-of-step oscillation separation devices based on apparent impedance angle trajectory are widely used in the power grid in China,and their reliability is of great importance.In this paper,the influence mechanism of series compensation on apparent impedance angle trajectory is analyzed.It reveals that series compensation capacitors reduce the equivalent impedance angle and consequently the apparent impedance angle cannot pass through all four zones,resulting in the risk of failure for the separation devices.A revised method of apparent impedance angle based on compensation principle is discussed,and then an improved out-of-step oscillation detection criterion is proposed.In view of the fact that the apparent impedance angle at the moment of maximum current is equal to the equivalent impedance angle during an oscillation process,a practical algorithm based on the compensated apparent impedance angle is proposed.RTDS tests are conducted to verify the effectiveness of the new criterion,considering transmission lines with a high series compensation level.
基金supporting program of the National Science Foundation for Distinguished Young Scholars of China(Project No.51325704)the National Basic Research Program of China(973 Program,Project No.2011CB711105-4)。
文摘With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument with high reliability which can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogowski coil sensor for better leakage current signal. To avoid the fluctuation from railway power supply,four modules are set to filter the power supply waveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation when leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator.