A survey was conducted in the equatorial area of Indian Ocean for a better understanding of the dynamics of hook depth distribution of pelagic longline fishery. We determined the relationship between hook depth and ve...A survey was conducted in the equatorial area of Indian Ocean for a better understanding of the dynamics of hook depth distribution of pelagic longline fishery. We determined the relationship between hook depth and vertical shear of current coefficieney, wind speed, hook position code, sine of wind angle, sine of angle of attack and weight of messenger weight. We identified the hook depth models by the analysis of covariance with a general linear model. The results showed that the wind effect on the hook depth can be ignored from October to November in the survey area; the surface current effect on the hook depth can be ignored; the equato- rial undercurrent is the key factor for the hook depth in Indian Ocean; and there is a negative correlation between the hook depth and vertical shear of current and angle of attack. It was also found that the deeper the hook was set, the higher hook depth shoaling was. The proposed model improves the accuracy of the prediction of hook depth, which can be used to estimate the vertical distribution of pelagic fish in water column.展开更多
Background: Clavicular hook plates are effective fixation devices for lateral end clavicle fractures and acromioclavicular joint dislocations and have been extensively used in the last decade. Although this plate achi...Background: Clavicular hook plates are effective fixation devices for lateral end clavicle fractures and acromioclavicular joint dislocations and have been extensively used in the last decade. Although this plate achieves a high percentage of union, there are concerns about sub-acromial osteolysis and impingement of supraspinatus tendon. Objective: To show that impingement of supraspinatus tendon can be prevented by measuring the depth between acromion and supraspinatus tendon posteriorly and using hook plates of appropriate depth. Materials and Methods: We performed a prospective study on 25 patients with lateral end clavicle fractures and acromio clavicular joint disruptions by measuring the depth between posterior border of acromion and the superior border of supraspinatus at the point of application of hook plate. Fixation is then done by appropriate sized hook plate. Results: None of the patients had impingement of supraspinatus tendon. Five patients developed subacromial osteolysis which did not have any impact on shoulder function. Conclusion: There is a variation in anatomy of the acromion in different ethnic groups. Hence uniform sized hook plate will be inappropriate. A smaller hook depth is needed in south Asian population to prevent impingement.展开更多
基金funded by Ministry of Agriculture of China under Project of Fishery Exploration in High Seasin 2006 (No. Z06-43)the National High Technology Research and Development Program of China (No. 2012AA092302)+1 种基金Specialized research fund for the doctoral program of higher education (No. 20113104110004)Shanghai Municipal Education Commission Innovation Project (No. 12ZZ168)
文摘A survey was conducted in the equatorial area of Indian Ocean for a better understanding of the dynamics of hook depth distribution of pelagic longline fishery. We determined the relationship between hook depth and vertical shear of current coefficieney, wind speed, hook position code, sine of wind angle, sine of angle of attack and weight of messenger weight. We identified the hook depth models by the analysis of covariance with a general linear model. The results showed that the wind effect on the hook depth can be ignored from October to November in the survey area; the surface current effect on the hook depth can be ignored; the equato- rial undercurrent is the key factor for the hook depth in Indian Ocean; and there is a negative correlation between the hook depth and vertical shear of current and angle of attack. It was also found that the deeper the hook was set, the higher hook depth shoaling was. The proposed model improves the accuracy of the prediction of hook depth, which can be used to estimate the vertical distribution of pelagic fish in water column.
文摘Background: Clavicular hook plates are effective fixation devices for lateral end clavicle fractures and acromioclavicular joint dislocations and have been extensively used in the last decade. Although this plate achieves a high percentage of union, there are concerns about sub-acromial osteolysis and impingement of supraspinatus tendon. Objective: To show that impingement of supraspinatus tendon can be prevented by measuring the depth between acromion and supraspinatus tendon posteriorly and using hook plates of appropriate depth. Materials and Methods: We performed a prospective study on 25 patients with lateral end clavicle fractures and acromio clavicular joint disruptions by measuring the depth between posterior border of acromion and the superior border of supraspinatus at the point of application of hook plate. Fixation is then done by appropriate sized hook plate. Results: None of the patients had impingement of supraspinatus tendon. Five patients developed subacromial osteolysis which did not have any impact on shoulder function. Conclusion: There is a variation in anatomy of the acromion in different ethnic groups. Hence uniform sized hook plate will be inappropriate. A smaller hook depth is needed in south Asian population to prevent impingement.