期刊文献+
共找到3,077篇文章
< 1 2 154 >
每页显示 20 50 100
Fault tolerant control of electric pitch control system based on single current detection
1
作者 李宏伟 付勃 +2 位作者 董海鹰 杨立霞 王睿敏 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第1期63-70,共8页
In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is sing... In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified. 展开更多
关键词 electric pitch control fault tolerant control variable universe fuzzy control single current detection
在线阅读 下载PDF
Planning method for AUV region detection under ocean current 被引量:1
2
作者 ZHANGMing-jun HANZhi-xue 《Journal of Marine Science and Application》 2004年第1期46-51,共6页
In this paper we present two strategies of AUV (Autonomous Underwater Vehicle) region detection and an approach to decompose the detection region according to the direction of the ocean current. In the task of local d... In this paper we present two strategies of AUV (Autonomous Underwater Vehicle) region detection and an approach to decompose the detection region according to the direction of the ocean current. In the task of local detection and identification, the algorithm against the ocean current was proposed. In the tasks of closing obstacle, going back or moving, the fuzzy logic theory was used to solve the effect of ocean current. In one of our strategies the concept of weighted journey based on the angle between heading and ocean current is suggested and the TSP's exact optimal result is utilized to solve the global path planning. Simulations demonstrate the feasibility of this approach. 展开更多
关键词 AUV ocean current region detection planning method
在线阅读 下载PDF
Fault detection and diagnosis of permanent-magnetic DC motors based on current analysis and BP neural networks 被引量:1
3
作者 刘曼兰 朱春波 王铁成 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第3期266-270,共5页
In order to guarantee quality during mass serial production of motors, a convenient approach on how to detect and diagnose the faults of a permanent-magnetic DC motor based on armature current analysis and BP neural n... In order to guarantee quality during mass serial production of motors, a convenient approach on how to detect and diagnose the faults of a permanent-magnetic DC motor based on armature current analysis and BP neural networks was presented in this paper. The fault feature vector was directly established by analyzing the armature current. Fault features were extracted from the current using various signal processing methods including Fourier analysis, wavelet analysis and statistical methods. Then an advanced BP neural network was used to finish decision-making and separate fault patterns. Finally, the accuracy of the method in this paper was verified by analyzing the mechanism of faults theoretically. The consistency between the experimental results and the theoretical analysis shows that four kinds of representative faults of low power permanent-magnetic DC motors can be diagnosed conveniently by this method. These four faults are brush fray, open circuit of components, open weld of components and short circuit between armature coils. This method needs fewer hardware instruments than the conventional method and whole procedures can be accomplished by several software packages developed in this paper. 展开更多
关键词 DC motor current analysis BP neural networks fault detection fault diagnosis
在线阅读 下载PDF
Nanofluidic ion rectification sensor for enantioselective recognition and detection
4
作者 Chong Wang Hao Xie +4 位作者 Rulan Xia Xuewei Liao Jin Wang Huajun Yang Chen Wang 《Chinese Chemical Letters》 2025年第8期601-606,共6页
Enantiomer identification is of paramount industrial value and physiological significance.Construction of sensitive chiral sensors with high enantiomeric discrimination ability is highly desirable.In this work,a chira... Enantiomer identification is of paramount industrial value and physiological significance.Construction of sensitive chiral sensors with high enantiomeric discrimination ability is highly desirable.In this work,a chiral covalent organic framework/anodic aluminum oxide(c-COF/AAO)membrane was prepared for electrochemical enantioselective recognition and sensing.Benefiting from the remarkable asymmetry,the asprepared nanofluidic c-COF/AAO presents a distinct ion current rectification(ICR)characteristic,enabling sensitive bioanalysis.In addition,owing to the large surface area,high chemical stability and perfect ion selectivity of chiral COF,the prepared c-COF/AAO membrane presents exceptionally selective mass transport and thereby enables excellent chiral discrimination for S-/R-Naproxen(S-/R-Npx)enantiomers.It is especially noteworthy that the detection limit is achieved as low as 3.88 pmol/L.These results raise the possibility for a facile,stable and low-cost method to carry out sensitive enantioselective recognition and detection. 展开更多
关键词 Nanofluidic sensor Chiral recognition lon current rectification(ICR) Covalentorganic framework Electrochemical detection
原文传递
Current Polarity Detection and Current Compensation Strategy for PAC Based Three-Phase ZVS PWM Converter
5
作者 屈克庆 陈国呈 孙承波 《Journal of Shanghai University(English Edition)》 CAS 2005年第6期539-543,共5页
A novel software implementation for current polarity detection and current compensation is presented. For a three-phase zero-voltage soft-switching (ZVS) PWM converter based on phase and amplitude control (PAC), w... A novel software implementation for current polarity detection and current compensation is presented. For a three-phase zero-voltage soft-switching (ZVS) PWM converter based on phase and amplitude control (PAC), when saw-tooth carriers with alternate positive and negative slopes are adopted, the positive or negative slopes are chosen according to the phase current polarity. Since polarity reversal causes current distortion, current at the instant of reversal should be compensated for. Based on the characteristic of unity power factor converter in rectification and regeneration modes, a software implementation for current polarity detection is proposed. Distortion of current zero-crossing caused by using saw-tooth carriers with alternate positive and negative slopes is analyzed, and the relevant compensation method is proposed. Experimental study with a 1.5 kW device shows that phase current has a small harmonic content and power factor is high both in rectification and regeneration modes. 展开更多
关键词 current polarity detection current compensation CONVERTER ZVS PAC.
在线阅读 下载PDF
High-sensitivity phase imaging eddy current magneto-optical system for carbon fiber reinforced polymers detection
6
作者 Jiang-Shan Ai Quan Zhou +5 位作者 Yi-Ping Liang Chun-Rui Feng Bing Long Li-Bing Bai Yong-Gang Wang Chao Ren 《Journal of Electronic Science and Technology》 EI CSCD 2023年第4期48-59,共12页
This paper proposed a high-sensitivity phase imaging eddy current magneto-optical (PI-ECMO) system for carbon fiber reinforced polymer (CFRP) defect detection. In contrast to other eddy current-based detection systems... This paper proposed a high-sensitivity phase imaging eddy current magneto-optical (PI-ECMO) system for carbon fiber reinforced polymer (CFRP) defect detection. In contrast to other eddy current-based detection systems, the proposed system employs a fixed position excitation coil while enabling the detection point to move within the detection region. This configuration effectively mitigates the interference caused by the lift-off effect, which is commonly observed in systems with moving excitation coils. Correspondingly, the relationship between the defect characteristics (orientation and position) and the surface vertical magnetic field distribution (amplitude and phase) is studied in detail by theoretical analysis and numerical simulations. Experiments conducted on woven CFRP plates demonstrate that the designed PI-ECMO system is capable of effectively detecting both surface and internal cracks, as well as impact defects. The excitation current is significantly reduced compared with traditional eddy current magneto-optical (ECMO) systems. 展开更多
关键词 Carbon fiber reinforced polymers Defect detection Eddy current magneto-optical Nondestructive testing Phase imaging
在线阅读 下载PDF
PRIMARY SIDE DETECTION AND PEAK CURRENT MODE CONTROL IN FLYBACK CONVERTER
7
作者 FangJian LuZhiping YangJian LiZhaoji 《Journal of Electronics(China)》 2004年第1期72-77,共6页
A new cycle-by-cycle control flyback converter with primary side detection and peak current mode control is proposed and its dynamic characteristics are analyzed. The flyback converter is verified by the OrCAD simulat... A new cycle-by-cycle control flyback converter with primary side detection and peak current mode control is proposed and its dynamic characteristics are analyzed. The flyback converter is verified by the OrCAD simulator. The main advantages of this converter over the conventional one are simplicity, small size, rapid regulating and no sensing control signals over the isolation barrier. The circuit is suitable for digital control implementations. 展开更多
关键词 Flyback converter Peak current mode Primary side detection
在线阅读 下载PDF
Stray Current Interference Detection and Evaluation on Storage Tanks
8
作者 ZHAO Xiaolong LI Guangyin LI Jie 《外文科技期刊数据库(文摘版)工程技术》 2020年第1期035-039,共5页
Detection method and evaluation standards are introduced in storage tank detection of DC stray current disturbance and AC stray current disturbance. Taking an oil storage tank as an example, this paper evaluates its o... Detection method and evaluation standards are introduced in storage tank detection of DC stray current disturbance and AC stray current disturbance. Taking an oil storage tank as an example, this paper evaluates its operating status under interference sources and provides the basis and references for its corrosion protection system reform and safe operation. 展开更多
关键词 Stray current detection EVALUATION
原文传递
Virtual Synchronous Generator Based Current Synchronous Detection Scheme for a Virtual Inertia Emulation in SmartGrids
9
作者 Arvind Parwal Martin Fregelius +7 位作者 Dalmo Cardosa Silva Tatiana Potapenko Johannes Hjalmarsson James Kelly Irina Temiz Janaina Goncalves de Oliveira Cecilia Bostrom Mats Leijon 《Energy and Power Engineering》 2019年第3期99-131,共33页
Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy... Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy demand means that the interest for the integration of renewable energy sources in the existing power system is growing, but such integration poses challenges to the operating stability. Power converters play a major role in the evolution of power system towards SmartGrids, by regulating as virtual synchronous generators. The concept of virtual synchronous generators requires an energy storage system with power converters to emulate virtual inertia similar to the dynamics of traditional synchronous generators. In this paper, a dynamic droop control for the estimation of fundamental reference sources is implemented in the control loop of the converter, including active and reactive power components acting as a mechanical input to the virtual synchronous generator and the virtual excitation controller. An inertia coefficient and a droop coefficient are implemented in the control loop. The proposed controller uses a current synchronous detection scheme to emulate a virtual inertia from the virtual synchronous generators. In this study, a wave energy converter as the power source is used and a power management of virtual synchronous generators to control the frequency deviation and the terminal voltage is implemented. The dynamic control scheme based on a current synchronous detection scheme is presented in detail with a power management control. Finally, we carried out numerical simulations and verified the scheme through the experimental results in a microgrid structure. 展开更多
关键词 current Synchronous detection Dynamic Droop Control Energy Storage Virtual Inertia Virtual Synchronous Generator
暂未订购
Parameter estimation and reliable fault detection of electric motors 被引量:1
10
作者 Dusan PROGOVAC Le Yi WANG George YIN 《Control Theory and Technology》 EI CSCD 2014年第2期110-121,共12页
Accurate model identification and fault detection are necessary for reliable motor control. Motor-characterizing parameters experience substantial changes due to aging, motor operating conditions, and faults. Conseque... Accurate model identification and fault detection are necessary for reliable motor control. Motor-characterizing parameters experience substantial changes due to aging, motor operating conditions, and faults. Consequently, motor parameters must be estimated accurately and reliably during operation. Based on enhanced model structures of electric motors that accommodate both normal and faulty modes, this paper introduces bias-corrected least-squares (LS) estimation algorithms that incorporate functions for correcting estimation bias, forgetting factors for capturing sudden faults, and recursive structures for efficient real-time implementation. Permanent magnet motors are used as a benchmark type for concrete algorithm development and evaluation. Algorithms are presented, their properties are established, and their accuracy and robustness are evaluated by simulation case studies under both normal operations and inter-turn winding faults. Implementation issues from different motor control schemes are also discussed. 展开更多
关键词 Electric machine Parameter estimation Fault detection Brushless direct current (BLDC) motor Bias correction Forgetting factor
原文传递
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
11
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 Active filter HARMONIC Reactive current Real-time detection Single-phase circuit Electric-network
在线阅读 下载PDF
An Adaptive EMD Technique for Induction Motor Fault Detection 被引量:1
12
作者 Manzar Mahmud Wilson Wang 《Journal of Signal and Information Processing》 2019年第4期125-138,共14页
Reliable induction motor (IM) fault detection techniques are very useful in industries to diagnose IM defects and improve operational performance. An adaptive empirical mode decomposition (EMD) technology is proposed ... Reliable induction motor (IM) fault detection techniques are very useful in industries to diagnose IM defects and improve operational performance. An adaptive empirical mode decomposition (EMD) technology is proposed in this paper for rotor bar fault detection in IMs. As the characteristic fault frequency will change with operating conditions related to load and speed, the proposed adaptive EMD technique correlates fault features over different frequency bands and intrinsic mode function (IMF) sidebands. The adaptive EMD technique uses the first IMF to detect the fault type and the second IMF as an indicator to predict the fault severity. It can overcome the problems of the sensitivity of sideband frequencies related to the speed and load oscillations. The effectiveness of the proposed adaptive EMD technique is verified by experimental tests under different motor conditions. 展开更多
关键词 INDUCTION Motors FAULT detection Broken ROTOR BARS current Signal Processing Empirical Mode DECOMPOSITION
在线阅读 下载PDF
Islanding Protection and Islanding Detection in Low Voltage CIGRE Distribution Network with Distributed Generations 被引量:1
13
作者 Ghullam Mustafa Bhutto Ehsan Ali +1 位作者 Jagdesh Kumar Muhammad Akram Bhayo 《Smart Grid and Renewable Energy》 2014年第6期152-159,共8页
The Power Quality (PQ), security, reliability etc., are the prime objectives of the power system. The protection is developed in such a way that it should be selective, fast, reliable and the cost effective. The study... The Power Quality (PQ), security, reliability etc., are the prime objectives of the power system. The protection is developed in such a way that it should be selective, fast, reliable and the cost effective. The study about the islanding protection in Low Voltage (LV) CIGRE distribution and networks like this has been proposed in this paper. This is achieved by developing the protection against the short circuit faults which might appear at the Medium Voltage (MV) bus. The protection of the network with significant penetration of the Distributed Generations (DGs) is a complicated process. The DG units which are directly connected to the grid such as synchronous or induction generators contribute large short power, whereas the DG units which are connected to the grid via inverters carry small amount of the short circuit power. This creates the problems in the protection of the network. If the proper protection coordination measures have not been taken, it might cause the mal-function of the protection devices which put the portion of the power network into the security threats. The selection of the islanding protection devices in this paper is made to protect the network against bi-directional currents at the time of short circuit fault. The LV CIGRE distribution network will enter into islanding if a fault is cleared at the MV bus by the proposed islanding protection devices. It is therefore, essential to detect the islanding in the CIGRE power network. The detection of the island in this network is another major objective of this paper. The detection of the island is proposed by using the technique which is based on the voltage phase angle difference. The simulations are carried out by using DIgSILENT power factory software version 15.0. 展开更多
关键词 ISLANDING PROTECTION Loss of Grid (LOG) Over current PROTECTION Under Voltage PROTECTION FUSES RELAYS Island detection (ID)
暂未订购
Instrument for insulation conditions detection of roof insulator on high-speed-train 被引量:2
14
作者 ZHANG Xueqin Yin Guolong +4 位作者 GAO Guoqiang SHAO Mengchun YIN Xianbin LI Chunmao WU Guangning 《Instrumentation》 2014年第2期50-59,共10页
With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the in... With the rapid development of high-speed-railway,environment around high voltage device on train roof becomes very complicated. Most train accidents happened due to occurrence of flashover on roof insulator,but the insulation condition estimation of insulator in such environment is much difficult. To ensure the insulation property of electric equipment,and guarantee the operation safety of high-speed-train,here established an instrument with high reliability which can on-line monitor insulation condition of roof insulator and give out advanced alarm before the incipient insulator flashover. The instrument consists of three parts,Data Acquisition & Sensor,Data Processing and Back Processing. Anti-interference and protection methods are processed to Rogowski coil sensor for better leakage current signal. To avoid the fluctuation from railway power supply,four modules are set to filter the power supply waveform. Through laboratory measurement,it is shown that the leakage current and the impedance angle can be detected by the instrument accurately. From the comparison of leakage current and impedance angle results under different moisture condition and the alarm operation when leakage current value reached threshold,this instrument can give out enough information for staff to understand the insulation condition of insulator. 展开更多
关键词 High-speed-train INSULATOR Insulation condition detection Leakage current Impedance Angle
原文传递
Study on the Detection Methods of DC Series Arc Fault 被引量:3
15
作者 JI Shengchang LIU Yuan ZHU Yeye ZHU Lingyu 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2131-2137,共7页
It is difficult to detect and extinguish direct current(DC)arc in power electronics systems,and the arc could easily lead to a fire and cause great damage to surrounding equipment.A DC arc generation simulation unit i... It is difficult to detect and extinguish direct current(DC)arc in power electronics systems,and the arc could easily lead to a fire and cause great damage to surrounding equipment.A DC arc generation simulation unit is established,in which DC series arcs are generated by dragging the moving electrode away from the fixed one with the help of the stepper motor.In addition,a ferrite rod antenna is used to receive the electromagnetic radiation signals induced by the arcs.Based on experiments using the unit,the general characteristics of DC arc,including the pulse characteristics of arc current and source output in corresponding time window,and the frequency-domain characteristics of arc current,are studied.With discussion on three detection methods,it is concluded that the variation of current and voltage of arc,the spectrum of the arc current during the discontinuous intervals and the radiating electromagnetic signal are all features that can be adopted for detecting DC series arc.Therefore,a synthetic judgment method is suggested for further study. 展开更多
关键词 故障检测方法 直流电弧 DC 电磁辐射信号 电力电子系统 电弧电流 模拟单元 脉冲特性
原文传递
基于拓扑图动力学模型的电力系统故障自动化检测系统
16
作者 张锐 《电子设计工程》 2026年第1期59-65,共7页
为了及时对电力系统故障进行修复,设计了基于拓扑图动力学模型的电力系统故障自动化检测系统。所提系统以DSP为核心设计数据采集器,连接电力系统零序电流传感器采集实时电流。通过模数转换模块将电流信号数字化,并由ARM处理器存储和传... 为了及时对电力系统故障进行修复,设计了基于拓扑图动力学模型的电力系统故障自动化检测系统。所提系统以DSP为核心设计数据采集器,连接电力系统零序电流传感器采集实时电流。通过模数转换模块将电流信号数字化,并由ARM处理器存储和传输数据。故障诊断单元利用拓扑动力学模型生成电力系统拓扑图,并基于此建立多种故障检测模型,对输入的电流数据进行分析,识别不同类型的电力系统故障。实验结果表明,所提方法在小型、中型、大型配电网中的故障检测率均不低于90%,远高于其他方法。所提系统具备较为准确的电力系统电流信号模数转换能力,同时可有效生成电力系统拓扑图,并可自动化检测出当前电力系统不同故障类型,能够为电力系统的安全稳定运行提供有力保障。 展开更多
关键词 拓扑图 动力学模型 电力系统 自动化检测 模数转换单元 电流幅值
在线阅读 下载PDF
基于电极消耗补偿的赤藓糖醇定量检测方法研究
17
作者 雍程翔 黄雨丝 +9 位作者 连俊博 张靖渝 郑越 韩文慧 吕琦 解雅萍 侯国丰 李欣霖 邹清芳 易晓梅 《传感技术学报》 北大核心 2026年第1期120-125,共6页
赤藓糖醇是一种应用广泛的天然甜味剂,其定量检测在食品加工、医疗保健等领域发挥着重要作用。为实现赤藓糖醇的精准、快速定量检测,设计了一种基于电极消耗补偿的溶液中赤藓糖醇定量检测方法。采用铜膜作为工作电极,饱和KCl电极作为参... 赤藓糖醇是一种应用广泛的天然甜味剂,其定量检测在食品加工、医疗保健等领域发挥着重要作用。为实现赤藓糖醇的精准、快速定量检测,设计了一种基于电极消耗补偿的溶液中赤藓糖醇定量检测方法。采用铜膜作为工作电极,饱和KCl电极作为参比电极,铂电极作为对电极。采用循环伏安法(CV)和计时电流法(i-t)对赤藓糖醇溶液进行扫描。CV结果表明,铜膜具有良好的氧化-还原性和稳定性。i-t结果表明,电流响应信号随着赤藓糖醇浓度的升高而增强。由于检测过程中电极会有所消耗,建立了一种电流校正模型对电流进行补偿。得到拟合模型为Itm(t)=0.59821X+0.02294,R^(2)达0.99940。所提方法有效提高了赤藓糖醇定量检测的准确性。 展开更多
关键词 电化学 定量检测 循环伏安法 计时电流法 电流校正模型 赤藓糖醇
在线阅读 下载PDF
金属坑蚀大提离脉冲涡流成像检测方法
18
作者 翟方昊 袁梦 +2 位作者 巩家伟 吴建飞 武新军 《仪表技术与传感器》 北大核心 2026年第1期86-90,96,共6页
针对大提离下铁磁性材料坑蚀缺陷脉冲涡流检测中信号易受噪声干扰且差异微弱的问题,提出一种结合小波阈值降噪和S-G滤波的信号预处理方法,并在此基础上设计相应成像算法。通过定量对比不同滤波方法处理后信号的信噪比、均方根误差和光... 针对大提离下铁磁性材料坑蚀缺陷脉冲涡流检测中信号易受噪声干扰且差异微弱的问题,提出一种结合小波阈值降噪和S-G滤波的信号预处理方法,并在此基础上设计相应成像算法。通过定量对比不同滤波方法处理后信号的信噪比、均方根误差和光滑度确定最优小波参数及S-G滤波参数,利用标准差选取成像区间,并基于区间内信号幅值进行成像。实验表明:基于小波阈值降噪和S-G滤波的脉冲涡流信号预处理与成像算法可以实现60 mm提离下Φ10×2 mm缺陷成像。 展开更多
关键词 脉冲涡流 大提离 坑蚀检测 滤波算法 成像算法
在线阅读 下载PDF
基于动态检测的高速铁路牵引回流不平衡特征分析及识别
19
作者 罗依梦 孟景辉 +4 位作者 谢博才 张涛 乔乾 王晓东 罗泽霖 《铁道标准设计》 北大核心 2026年第1期179-186,195,共9页
随着列车速度不断提高,不平衡牵引回流对信号系统的干扰影响随之增加。为了通过动态检测手段有效描述并识别牵引回流不平衡,对牵引回流动态检测数据展开深入分析,分析结果表明,(1)检测车单一采集端数据无法全面反映牵引回流均衡情况;(2... 随着列车速度不断提高,不平衡牵引回流对信号系统的干扰影响随之增加。为了通过动态检测手段有效描述并识别牵引回流不平衡,对牵引回流动态检测数据展开深入分析,分析结果表明,(1)检测车单一采集端数据无法全面反映牵引回流均衡情况;(2)单一牵引回流动态检测指标并不能有效反映牵引回流的均衡性。(3)牵引回流均衡性与列车运行速度有关,速度越大牵引回流均衡性越差。针对以上情况,提出“牵引回流不平衡度”指标表征及其识别方法。首先,对车头尾两端数据进行里程校准,然后按照回流点位置将数据划分为若干个回流单元;针对每一个回流单元,获取机车受流后分别流经两条钢轨的全部电流,并基于Sigmoid函数对牵引回流不平衡值及不平衡系数进行归一化映射,将值域映射至(0,1);最后,针对列车在每个回流单元内的运行速度计算牵引回流不平衡度指标,对牵引回流均衡性做出分类。为了验证所提指标对于牵引回流不平衡的识别效果,与采用现有检测指标的识别方法进行对比试验。基于实际检测数据的试验结果表明,所提出的指标对于牵引回流不平衡引起的轨道电路干扰识别正确率为99.97%,比应用现有牵引回流不平衡值、牵引回流不平衡系数指标的识别正确率分别提高0.04%、45.24%。 展开更多
关键词 高速铁路 动态检测 牵引回流 不平衡电流 特征分析 SIGMOID函数
在线阅读 下载PDF
用于正交及单向CFRP分层检测的新型涡流传感器
20
作者 吕轶 马启佳 蓝晓宇 《仪表技术与传感器》 北大核心 2026年第1期28-34,共7页
针对碳纤维增强复合材料(carbonfiberreinforcedpolymer,CFRP)分层缺陷检测中传统涡流传感器因对铺层方向敏感性不足导致的漏检问题,提出了一种基于反向电流激励的三异面矩形线圈传感器。利用COMSOL有限元软件分别构建正交铺层与单向铺... 针对碳纤维增强复合材料(carbonfiberreinforcedpolymer,CFRP)分层缺陷检测中传统涡流传感器因对铺层方向敏感性不足导致的漏检问题,提出了一种基于反向电流激励的三异面矩形线圈传感器。利用COMSOL有限元软件分别构建正交铺层与单向铺层CFRP系统模型,验证所提线圈传感器的缺陷响应特性。通过单轴扫描获取感应电压差值随位置的分布曲线,结合缺陷敏感性优化传感器关键参数。结合二维平面扫描,实现缺陷信息的可视化。结果表明:该线圈传感器对正交铺层与单向铺层CFRP的分层缺陷检测灵敏度分别达到10.57%和10.45%,且经可视化成像后,可观测到缺陷范围。 展开更多
关键词 涡流检测 碳纤维增强复合材料 线圈传感器 缺陷检测 分层缺陷
在线阅读 下载PDF
上一页 1 2 154 下一页 到第
使用帮助 返回顶部