期刊文献+
共找到40,866篇文章
< 1 2 250 >
每页显示 20 50 100
Advanced Design for High-Performance and AI Chips
1
作者 Ying Cao Yuejiao Chen +2 位作者 Xi Fan Hong Fu Bingang Xu 《Nano-Micro Letters》 2026年第1期306-336,共31页
Recent years have witnessed transformative changes brought about by artificial intelligence(AI)techniques with billions of parameters for the realization of high accuracy,proposing high demand for the advanced and AI ... Recent years have witnessed transformative changes brought about by artificial intelligence(AI)techniques with billions of parameters for the realization of high accuracy,proposing high demand for the advanced and AI chip to solve these AI tasks efficiently and powerfully.Rapid progress has been made in the field of advanced chips recently,such as the development of photonic computing,the advancement of the quantum processors,the boost of the biomimetic chips,and so on.Designs tactics of the advanced chips can be conducted with elaborated consideration of materials,algorithms,models,architectures,and so on.Though a few reviews present the development of the chips from their unique aspects,reviews in the view of the latest design for advanced and AI chips are few.Here,the newest development is systematically reviewed in the field of advanced chips.First,background and mechanisms are summarized,and subsequently most important considerations for co-design of the software and hardware are illustrated.Next,strategies are summed up to obtain advanced and AI chips with high excellent performance by taking the important information processing steps into consideration,after which the design thought for the advanced chips in the future is proposed.Finally,some perspectives are put forward. 展开更多
关键词 Artificial intelligence Advanced chips AI chips Design tactics Review and perspective
在线阅读 下载PDF
Quantitative Study of Multiple Components in Tetracera asiatica Based on High-Performance Liquid Chromatography
2
作者 Fangfang DA Yufeng CHEN +4 位作者 Ziwan YUAN Ying LIU Yaoting MENG Kequn HE Yanmin XIE 《Asian Agricultural Research》 2025年第10期28-31,44,共5页
[Objectives]To establish an HPLC method for the quantitative determination of multiple phenolic acid components in Tetracera asiatica medicinal material,providing a basis for establishing its quality standards.[Method... [Objectives]To establish an HPLC method for the quantitative determination of multiple phenolic acid components in Tetracera asiatica medicinal material,providing a basis for establishing its quality standards.[Methods]An Inertsil ODS-C 18 column(250 mm×4.6 mm,5μm)was used.The mobile phase consisted of acetonitrile-0.2% phosphoric acid solution(10:90).The flow rate was 1.0 mL/min.The detection wavelength was 274 nm.The column temperature was 25℃.The injection volume was 10μL.The content of three components,gallic acid,protocatechuic acid,and protocatechualdehyde,was determined in 13 batches of T.asiatica.[Results]Gallic acid showed good linearity within the range of 0.020-6.400μg/mL,protocatechuic acid within 0.201-6.432μg/mL,and protocatechualdehyde within 0.202-6.464μg/mL(r>0.9990).The average recovery rates ranged from 98.61%to 101.17%,with RSD s between 1.21%and 2.69%.[Conclusions]The quantitative determination method established in this study is simple and feasible,and can provide a basis for the quality evaluation of T.asiatica. 展开更多
关键词 Tetracera asiatica high-performance LIQUID CHROMATOGRAPHY (HPLC) COMPONENTS QUANTITATIVE determination
在线阅读 下载PDF
Compact Cold-Atom Platform Based on Optical Grating and Planar Coil Chips
3
作者 Chang-Jiang Huang Lei Xu +4 位作者 Liang Chen Chuan-Feng Li Guang-Can Guo Chang-Ling Zou Guo-Yong Xiang 《Chinese Physics Letters》 2025年第6期58-62,共5页
We present a compact cold atom platform where an optical grating chip and planar coil chip are placed inside a compact vacuum chamber to create a magneto-optical trap.This approach significantly reduces the system vol... We present a compact cold atom platform where an optical grating chip and planar coil chip are placed inside a compact vacuum chamber to create a magneto-optical trap.This approach significantly reduces the system volume to about 20×20×20 cm^(3) compared to conventional vacuum systems and offers greater flexibility in accessing the trapped atoms.We demonstrate the trapping of 3×10^(5) cold rubidium atoms at a temperature of 100μK in a vacuum pressure below 10^(−7) mbar.The simplified optical geometry,low power consumption,and high degree of integration make this a promising platform for portable and versatile cold-atom devices in quantum sensing,timing,and information processing. 展开更多
关键词 optical grating chip conventional vacuum systems planar coil chip rubidium atoms compact cold atom platform compact vacuum chamber
原文传递
Facile synthesis of single-crystal 3D covalent organic frameworks as stationary phases for high-performance liquid chromatographic separation
4
作者 Qiuting Zhang Fan Wu +3 位作者 Jin Liu Hang Su Yanhui Zhong Zian Lin 《Chinese Chemical Letters》 2025年第8期596-600,共5页
Covalent organic frameworks(COFs)have demonstrated great potential in chromatographic separation because of unique structure and superior performance.Herein,single-crystal three-dimensional(3D)COFs with regular morpho... Covalent organic frameworks(COFs)have demonstrated great potential in chromatographic separation because of unique structure and superior performance.Herein,single-crystal three-dimensional(3D)COFs with regular morphology,good monodispersity and high specific surface area,were used as a stationary phase for high-performance liquid chromatography(HPLC).The single-crystal 3D COFs packed column not only exhibits high efficiency in separating hydrophobic molecules involving substituted benzenes,halogenated benzenes,halogenated nitrobenzenes,aromatic amines,aromatic hydrocarbons(PAHs)and phthalate esters(PAEs),but also achieves baseline separation of acenaphthene and acenaphthylene with similar physical and chemical properties as well as environmental pollutants,which cannot be quickly separated on commercial C18 column and a polycrystalline 3D COFs packed column.Especially,the column efficiency of 17303-24255 plates/m was obtained for PAEs,and the resolution values for acenaphthene and acenaphthylene,and carbamazepine(CBZ)and carbamazepine-10,11-epoxide(CBZEP)were 1.7and 2.2,respectively.This successful application not only confirmed the great potential of the singlecrystal 3D COFs in HPLC separation of the organic molecules,but also facilitates the application of COFs in separation science. 展开更多
关键词 Single-crystal 3D covalent organic frameworks high-performance liquid chromatography Stationary phase SEPARATION
原文传递
Developments and Challenges in Direct Ink Writing for High-Performance Polymers
5
作者 Zhangzhang Tang Yaoming Zhang +4 位作者 Liming Tao Zenghui Yang Peng Liu Qihua Wang Tingmei Wang 《Additive Manufacturing Frontiers》 2025年第2期111-133,共23页
Compared to subtractive manufacturing and casting,3D printing(additive manufacturing)offers advantages,such as the rapid production of complex structures,reduced material waste,and environmental friendliness.Direct in... Compared to subtractive manufacturing and casting,3D printing(additive manufacturing)offers advantages,such as the rapid production of complex structures,reduced material waste,and environmental friendliness.Direct ink writing(DIW)is one of the most popular 3D printing techniques owing to its ability to print multiple materials simultaneously and its high compatibility with printing inks.However,DIW presents significant challenges,particularly in the printing of high-performance polymers.The main challenges are as follows:1.The rigid structures and reaction kinetics of high-performance polymers make developing new inks difficult.2.The limited types of available high-performance polymers underscore the need for new DIW-suitable materials.3.Layer-by-layer stacking weakens interlayer bonding,affecting the mechanical properties of the printed product.4.The accuracy and speed of DIW printing are insufficient for large-scale manufacturing.After introducing the topic,the requirements for DIW printing inks are first reviewed,emphasizing the importance of thixotropic agents.Then,research progress regarding DIW printing of high-performance polymers is comprehensively reviewed according to the requirements of different polymer inks.Additionally,the applications of these materials across various fields are summarized.Finally,the challenges in DIW printing of high-performance polymers,along with corresponding solutions and future development prospects,are discussed in detail. 展开更多
关键词 3D printing Direct ink writing Printing ink Polymer material high-performance polymer
在线阅读 下载PDF
Optimization of wide frequency range 6H-SiC MEMS chips for a fiber optic Fabry–Perot accelerometer
6
作者 Mariano Mahissi Xinli Ma +2 位作者 Weiming Cai Xianmin Zhang Michel Dossou 《Chinese Physics B》 2025年第7期326-332,共7页
Vibration detection using sensors with both wide working frequency range,good sensitivity,and other good performances is a topic of great interest in fields such as inertial navigation,deep-sea fishing boat engines co... Vibration detection using sensors with both wide working frequency range,good sensitivity,and other good performances is a topic of great interest in fields such as inertial navigation,deep-sea fishing boat engines condition monitoring,seismic monitoring,attitude,and heading reference system,etc.This paper investigates two 6H-SIC MEMS diaphragms,one triangular and the other square,used in a fiber optic Fabry–Perot(FP)accelerometer in an experimental scenario.The triangular chip shows a wide working frequency range of 630 Hz–5300 Hz,a natural frequency of 44.3 k Hz,and a mechanical sensitivity of 0.154 nm/g.An optimal structure of the square chip used in a probe such as a fiber optic FP accelerometer also shows a wide working frequency range of 120 Hz–2300 Hz;a good sensitivity of 31.5 m V/g,a resonance frequency of7873 Hz,an accuracy of 0.96%F.S.,a frequency measurement error of 1.15%,and an excellent linearity of 0.9995. 展开更多
关键词 triangular chip ACCELEROMETER MEMS working frequency range optical fiber
原文传递
Development and Performance Study of High-Performance Electronic Packaging Materials
7
作者 Shenglan Fang 《材料科学研究(中英文版)》 2025年第2期1-6,共6页
As electronic devices continue to evolve toward higher power densities,faster speeds,and smaller form factors,the demand for high-performance electronic packaging materials has become increasingly critical.These mater... As electronic devices continue to evolve toward higher power densities,faster speeds,and smaller form factors,the demand for high-performance electronic packaging materials has become increasingly critical.These materials serve as the physical and functional interface between semiconductor components and their operating environment,impacting the overall reliability,thermal management,mechanical protection,and electrical performance of modern electronic systems.This study investigates the development,formulation,and performance evaluation of advanced packaging materials,focusing on polymer-based composites,metal and ceramic matrix systems,and nanomaterial-enhanced formulations.A comprehensive analysis of key performance metrics-including thermal conductivity,electrical insulation,mechanical robustness,and environmental resistance-is presented,alongside strategies for material optimization through interface engineering and processing innovations.Furthermore,the study explores cutting-edge integration technologies such as 3D packaging compatibility,low-temperature co-firing,and high-density interconnects.The findings provide critical insights into the structure-property-processing relationships that define the effectiveness of next-generation packaging materials and offer a roadmap for material selection and system integration in high-reliability electronic applications. 展开更多
关键词 Electronic Packaging Materials Thermal Interface Materials high-performance Composites NANOMATERIALS Thermal Conductivity 3D Packaging RELIABILITY Polymer Composites Dielectric Properties MICROFABRICATION
在线阅读 下载PDF
Pathological quality control chips for tuberculosis
8
作者 Enru Ye Jing He +5 位作者 Lingna Zhang Chaofan He Qiuju Zhou Juan Xu Meifu Gan Yong He 《Bio-Design and Manufacturing》 2025年第6期962-975,I0024-I0027,共18页
Globally,approximately 10 million new tuberculosis(TB)cases are reported annually.Delayed diagnosis due to low detection rates is the primary cause of mortality.Although pathological examination is commonly used for d... Globally,approximately 10 million new tuberculosis(TB)cases are reported annually.Delayed diagnosis due to low detection rates is the primary cause of mortality.Although pathological examination is commonly used for diagnosing TB,5%-30%of cases remain undiagnosed,emphasizing the urgent need to establish quality control(QC)standards to reduce rates of misdiagnosis and missed diagnoses.To address this,we introduced a novel QC chip for detecting Mycobacterium tuberculosis(MTB).A quantitative pathological QC model was constructed by precisely and uniformly integrating MTB and HeLa cells into a photocurable hydrogel.This model was then sliced into uniform sections to create QC chips.It demonstrated that the QC chips exhibited no significant differences in intra-batch or inter-batch variation(coefficient of variation<5%),and remained stable at−80°C for one year.Furthermore,these chips were found to be 100%effective when tested with 240 clinical samples(200 with special staining and 40 with polymerase chain reaction).In addition to enhancing TB detection rates,this approach offers visualization,quantification,and sustainable production.Overall,this work provides a novel framework for developing QC chips for pathological testing,offering a reliable solution to enhance clinical diagnostic workflows. 展开更多
关键词 Mycobacterium tuberculosis(MTB) Pathological model Quality control(QC)chip
在线阅读 下载PDF
“Chinese Chips+Mexican Manufacturing+U.S.market”The Triangular Trade Reshapes the Auto Industry
9
作者 Yang Jing 《China's Foreign Trade》 2025年第5期28-31,共4页
The current global economic and trade landscape is undergoing profound changes.Since the outbreak of the China-US trade friction in 2018,the United States has systematically promoted the“de-Sinicizat ion”strategy in... The current global economic and trade landscape is undergoing profound changes.Since the outbreak of the China-US trade friction in 2018,the United States has systematically promoted the“de-Sinicizat ion”strategy in the supply chain through measures such as imposing tariffs,exercising technology blockades,and setting up industrial subsidy barriers.Chinese products,including automot ive par ts and elect ronic equipment,have been significantly impacted. 展开更多
关键词 imposing tariffsexercising technology blockadesand industrial subsidy barrierschinese supply chain Mexican manufacturing automot ive par ts U S market Chinese chips economic trade landscape
在线阅读 下载PDF
Intelligent integration and advancement of multi-organ-on-a-chip
10
作者 Chen-Xi Song Lu Huang 《Biomedical Engineering Communications》 2026年第1期1-3,共3页
Multi-organ-on-a-chip(MOOC)technology represents a pivotal direction in the organ-on-a-chip field,seeking to emulate the complex interactions of multiple human organs in vitro through microfluidic systems.This technol... Multi-organ-on-a-chip(MOOC)technology represents a pivotal direction in the organ-on-a-chip field,seeking to emulate the complex interactions of multiple human organs in vitro through microfluidic systems.This technology overcomes the limitations of traditional single-organ models,providing a novel platform for investigating complex disease mechanisms and evaluating drug efficacy and toxicity.Although it demonstrates broad application prospects,its development still faces critical bottlenecks,including inadequate physiological coupling between organs,short functional maintenance durations,and limited real-time monitoring capabilities.Contemporary research is advancing along three key directions,including functional coupling,sensor integration,and full-process automation systems,to propel the technology toward enhanced levels of physiological relevance and predictive accuracy. 展开更多
关键词 investigating complex disease mechanisms emulate complex interactions multiple human organs vitro sensor integration intelligent integration predictive accuracy physiological coupling multi organ chip microfluidic systemsthis
在线阅读 下载PDF
社会资本与中国农村养老保险——基于CHIPS数据的实证研究 被引量:5
11
作者 张文闻 陈广汉 《社会保障研究》 CSSCI 2016年第5期11-17,共7页
党的十八大以来,习近平总书记多次发表重要论述,阐明自己的"民生观",指出中国养老问题的重要性。改革开放以来,中国经济、社会、政治都发生了巨大变化。福利一词也越来越多为人所谈论。本文以农村养老保险为切入口,研究社会... 党的十八大以来,习近平总书记多次发表重要论述,阐明自己的"民生观",指出中国养老问题的重要性。改革开放以来,中国经济、社会、政治都发生了巨大变化。福利一词也越来越多为人所谈论。本文以农村养老保险为切入口,研究社会资本、党员身份与农村养老保险的参与程度、知情程度、未来参与意愿之间的关系,从一个侧面反映中国农村的福利情况。通过文献综述,提出了六个假设。根据中国家庭收入调查(CHIPS)数据,建立Logistic回归模型,发现社会资本对是否参加农村养老保险、是否知道个人账户有多少钱、将来是否加入农村养老保险都有积极作用;党员身份与是否参加农村养老保险、是否知道自己的个人账户有多少钱、将来是否可能参加无关。结果表明,提高村民的社会资本,加强他们的社会交往有助于他们获取信息,改善福利,所以可以提高村民小组活动和村民大会的频率以增加农民的社会资本。 展开更多
关键词 社会资本 农村养老保险 chips
在线阅读 下载PDF
High-performance liquid chromatographic fingerprint analysis of Oxytropis falcata Bunge and Oxytropis chiliophylla Royle 被引量:4
12
作者 格桑罗布 确生 +4 位作者 格桑帕卓 张晓晶 桑罗 梁鸿 张庆英 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2014年第11期783-789,共7页
A simple, sensible and reliable HPLC-DAD fingerprint analysis method for the raw materials of Oxytropisfalcata and Oxytropis chiliophylla, both of which were used as "Er-Da-Xia" in Tibetan medicines, was developed a... A simple, sensible and reliable HPLC-DAD fingerprint analysis method for the raw materials of Oxytropisfalcata and Oxytropis chiliophylla, both of which were used as "Er-Da-Xia" in Tibetan medicines, was developed and then subsequently applied to analyze samples collected from different locations or times. 19 common fingerprint peaks for O. falcata, 24 for O. chiliophylla, and 11 for the two herbs were designated respectively, including 7 identified characteristic peaks existing in both herbs and 1 uniquely presenting in O. chiliophylla. Although there were some slight differences in the chemicals of O. falcata and O. chiliophylla, the main components of both herbs were consistent generally. The results provided scientific basis, at least from the chemical point of view, for the reasonablity of two herbs being used as the same drug in Tibetan medicines and for the necessary of further investigation on their detailed chemical and pharmacological differences. 展开更多
关键词 Oxytropis falcata Oxytropis chiliophylla high-performance liquid chromatographic fingerprint Quality analysis Tibetan medicines Er-Da-Xia
原文传递
CHIPS教学理念在药理学教学中的应用 被引量:6
13
作者 刘新华 朱依谆 《药学教育》 2013年第1期33-35,共3页
CHIPS是一种新型的培养教育模式,通过CHIPS培养模式不仅提高了药理学教师的教学业务水平,更是培养学生在药理学课程学习过程中的自学能力、科研思维和创新能力。
关键词 药理学 chips 教学
暂未订购
Measurement and analysis of defects in high-performance concrete with three-dimensional micro-computer tomography 被引量:8
14
作者 郭丽萍 Andrea Carpinteri +1 位作者 孙伟 秦文超 《Journal of Southeast University(English Edition)》 EI CAS 2009年第1期83-88,共6页
In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomogra... In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomography)is employed to quantitatively analyze the initial defects in four series of highperformance concrete (HPC)specimens with additions of different mineral admixtures. The nigh-resolution 3D images of microstructures and filtered defects are reconstructed by micro- CT software. The size distribution and volume fractions of initial defects are analyzed based on 3D and 2D micro-CT images. The analysis results are verified by experimental results of watersuction tests. The results show that the additions of mineral admixtures in concrete as cementitious materials greatly change the geometrical properties of the microstructures and the spatial features of defects by physical-chemistry actions of these mineral admixtures. This is the major cause of the differences between the mechanical behaviors of HPC with and without mineral admixtures when the water-to-binder ratio and the size distribution of aggregates are constant. 展开更多
关键词 high-performance concrete DEFECT MICROSTRUCTURE X- ray micro-focus computer tomography mineral admixtures
在线阅读 下载PDF
耐甲氧西林金黄色葡萄球菌CHIPS基因的克隆、序列分析及原核表达 被引量:3
15
作者 容莉莉 杨镒宇 +4 位作者 关锐梨 关小珊 邓秋连 谢永强 周珍文 《广州医药》 2013年第4期1-4,共4页
目的对耐甲氧西林金黄色葡萄球菌(MRSA)趋化抑制蛋白(CHIPS)进行扩增、克隆、序列分析、原核表达及纯化,为后续的疫苗研究奠定基础。方法根据GenBank中趋化抑制蛋白(CHIPS)的序列,设计一对特异性引物,以耐甲氧西林金黄色葡萄球菌DNA为模... 目的对耐甲氧西林金黄色葡萄球菌(MRSA)趋化抑制蛋白(CHIPS)进行扩增、克隆、序列分析、原核表达及纯化,为后续的疫苗研究奠定基础。方法根据GenBank中趋化抑制蛋白(CHIPS)的序列,设计一对特异性引物,以耐甲氧西林金黄色葡萄球菌DNA为模板PCR扩增CHIPS基因,纯化DNA进行EcoRI、XhoI双酶切鉴定及测序鉴定,并将CHIPS亚克隆入表达载体PET-28α,转化感受态大肠杆菌BL21,对质粒进行双酶切鉴定及基因序列分析,用IPTG诱导表达重组蛋白,His标签单克隆抗体进行免疫印迹验证重组蛋白的表达。结果以金黄色葡萄球菌临床儿童分离株基因组为模板,成功扩增CHIPS基因,基因大小为450bp;重组PET-28a(+)-CHIPS双酶切鉴定可见目的片段,测序结果显示CHIPS在正确读框中,序列比对分析显示其与相关报道核苷酸序列一致性达99.98%。经IPTG诱导后,pET-28a(+)-CHIPS/BL21在相应分子量(17kDa)可见融合蛋白在上清表达,免疫印迹检测到目的蛋白。结论成功从儿童分离株MRSA中构建了CHIPS的原核表达系统,并成功在大肠杆菌BL21中融合表达,为后续的疫苗研究奠定基础。 展开更多
关键词 MRSA chips 克隆 原核表达
暂未订购
CHIPS教学理念在药理学教学中的探索和实践 被引量:1
16
作者 吕小华 尤婷婷 +4 位作者 廖红波 王丹丹 刘钰瑜 吴铁 罗世英 《基础医学教育》 2016年第4期275-277,共3页
为了加强高等医药院校人才素质的培养,通过CHIPS教学理念在药理学教学中的探索和实践,促进药理学教学理念的更新和教学质量的提高,从而培养具有创新精神、较强的动手能力和主动性的富有潜力的、服务于社会的药学人才。
关键词 药理学 chips 教学改革
暂未订购
Analysis of the influence of processing of bran stir-baking on the main components of Paeoniae Radix Alba-Atractylodis Macrocephalae Rhizoma herbal pair by high-performance liquid chromatography 被引量:5
17
作者 方新华 吴鑫 +2 位作者 曹岗 蔡皓 蔡宝昌 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2015年第4期231-235,共5页
The crude and processed Paeoniae Radix Alba-Atractylodis Macrocephalae Rhizoma herbal pairs, originated from Bai-zhu-shao-yao-san, are used to treat different diseases clinically. In order to evaluate the crude and pr... The crude and processed Paeoniae Radix Alba-Atractylodis Macrocephalae Rhizoma herbal pairs, originated from Bai-zhu-shao-yao-san, are used to treat different diseases clinically. In order to evaluate the crude and processed Paeoniae Radix-Atractylodis Macrocephalae Rhizoma herbal pairs, a simple, easy, and sensitive high-performance liquid chromatography coupled with diode array detectors was developed for simultaneous determination of nine bioactive components in the herbal pairs. The calibration curve exhibited good linearity(r2≥0.9992). The LODs and LOQs were ≤7.30 and 11.53 μg/m L, respectively. The intra-, inter-day and repeatability RSD values of the nine compounds were less than 3.86%, 2.71%, and 4.29%, respectively. The RSD stability values were less than 3.64%. The recovery of the method was in the range of 96.70%–102.10%, with RSD values less than 3.52%. The developed method can be applied to the intrinsic quality control of crude and processed Paeoniae Radix-Atractylodis Macrocephalae Rhizoma herbal pairs. 展开更多
关键词 high-performance liquid chromatography Processing Quantification Paeoniae Radix Alba Atractylodis Macrocephalae Rhizoma
原文传递
Preliminary Studies on High-performance Liquid Chro-matography Chemiluminescence Determination of theSaturated Fatty Acids(C_(16) C_(18))in Human Serum 被引量:1
18
作者 段更利 中岛宪一郎 +1 位作者 黑田直敬 秋山修三 《Journal of Chinese Pharmaceutical Sciences》 CAS 1995年第1期22-29,共8页
The peroxyoxalate chemiluminescence(CL)detection of fatty acids in human se- rum combined with high-performance liquid chromatography (HPLC)is described.Some fatty acids in serum were extracted with a 1 :1(v/v)mixture... The peroxyoxalate chemiluminescence(CL)detection of fatty acids in human se- rum combined with high-performance liquid chromatography (HPLC)is described.Some fatty acids in serum were extracted with a 1 :1(v/v)mixture of chloroform-n-heptane.2-(4-Hydrazinocarbonyl- phenyl)-4,5-diphenylimidazole (HCPI) was used as a fluorescent labelling reagent of the fatty acids. The labelling reaction was carried out at 30℃ for 1 h at pH 6.5 and the resulting reaction mixture was sudjected to HPLC. The labelled fatty acid C_(17)(P-C_(17))was used as the internal standard. The la- belled fatty acids C_(16) and C_(18) were separated within 18 min on an ODS-8OTM column (150 mm× 6 mm ID,5μm,Tosoh Japan).The calibrlation curves of fatty acids from the spiked control serum were Y_1=-0.003 7 + 0.0028X_1,r=0.994 for FA C_( 16) and Y_2=0.00 1 2 + 0.00098X_2,r=0.999 for FA C_( 18),respectively.The average recoveries of facids from the spiked contrl serum were 107.2%(n=8,RSD=4.3%)for FA C_(16) and 97.35%(n=8, RSD=4.0%)for FA C_(18),respectively.The lower detection limits of fatty acids after reaction were 12μmol per 20μl injection for FA C_(16) and 18 μmol per 20μl injection for FA C_(18),respectively(signal to noise ratio, S/N=2).The HPLC/CL method was applied to the determination of FA C_(16) and FA C_(18) in normal human serum and the results showed that the concentrations of fatty acids in normal human serum were 0.134 ± 0.009 μ mol/ml serum(n=5) for FA C_(16) and 0.052±0.028 μmol/ml serum(n=5)for FA C_(18),respectively. 展开更多
关键词 Fatty acids high-performance Liquid Chromatography Peroxyoxalate chemi- luminescence detection Human serum
暂未订购
世界性的资金调拨系统——CHIPS 被引量:1
19
作者 张卓其 《信息系统工程》 1997年第3期16-16,共1页
第二次世界大战后,商品生产的规模和交换方式都发生了很大的变化。科学技术的发展,促使劳动生产率迅速提高和国际贸易急速发展,从而使商品流动和货币流动急速加大。通过电信和手工处理纸基票证这种传统的转帐方式,已经不能适应时代发展... 第二次世界大战后,商品生产的规模和交换方式都发生了很大的变化。科学技术的发展,促使劳动生产率迅速提高和国际贸易急速发展,从而使商品流动和货币流动急速加大。通过电信和手工处理纸基票证这种传统的转帐方式,已经不能适应时代发展的要求。为适应国际贸易急速发展的需要,从60年代末开始,国际银行界纷纷研究建立各种国际资金调拨系统。在诸多国际资金调拨系统中,最重要的是SWIFT系统和CHIPS系统。SWIFT系统主要提供通信服务,为其成员金融机构传送各种标准的国际资金调拨信息。 展开更多
关键词 资金调拨系统 chips 世界贸易
全文增补中
Determination of gallic acid in the traditional Chinese medicine by high-performance capillary electrophoresis 被引量:4
20
作者 高杨亚雅 朱尘琪 +6 位作者 郭爽 邱百灵 吴迪 高也 梁启慧 韩南银 张萍 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2016年第10期747-753,共7页
Rhizoma Polygoni Bistortae has been widely used as an important medicinal herb in the Far East for a few thousand years, and it has gained more recognition in the last few decades. In the present study, we used a high... Rhizoma Polygoni Bistortae has been widely used as an important medicinal herb in the Far East for a few thousand years, and it has gained more recognition in the last few decades. In the present study, we used a high-performance capillary electrophoresis (HPCE) method for determination of the gallic acid (GA) in Quanshen (QS) pieces. The analysis of GA in QS pieces was successfully achieved in less than 6 min by capillary electrophoresis with UV detection at a wavelength of 290 nm. The background electrolyte was 20 mmol/L sodium borate solution (pH 9.00). The separation was performed in an uncoated fused-silica capillary (52 cm^50 lam) with an effective length of 40 cm, and the applied voltage was 20 kV. Sample solutions were injected for l0 s at an atmospheric pressure of 5 KPa. The result showed good resolution and precision (the intra-day RSD was 0.37%). The calibration curves of the standard solutions were linear in the range of 0.22-2.25 mg/mL, with correlation coefficients greater than 0.9990. The recovery of the method ranged from 100.6% to 107.9%, and the average recovery of GA was 105.9% with an RSD of 3.63%. HPCE is a powerful technology, and it is the first time to successfully apply such a method for the determination of GA in the traditional Chinese medicine. 展开更多
关键词 Traditional Chinese medicine Quanshen Gallic acid high-performance capillary electrophoresis Quanshen pieces
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部