期刊文献+
共找到46,876篇文章
< 1 2 250 >
每页显示 20 50 100
Residual stresses of polycrystalline CBN abrasive grits brazed with a high-frequency induction heating technique 被引量:2
1
作者 Wei XU Yejun ZHU +1 位作者 Baicun DU Wenfeng DING 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2019年第4期1020-1029,共10页
Residual stresses produced in polycrystalline CBN abrasive grits during a high-frequency induction brazing process are calculated by using ?nite element analysis, with a consideration of the nonuniform temperature dis... Residual stresses produced in polycrystalline CBN abrasive grits during a high-frequency induction brazing process are calculated by using ?nite element analysis, with a consideration of the nonuniform temperature distribution in the induction brazing model. The in?uences of induction brazing parameters on the residual stresses of polycrystalline CBN abrasive grits have been analyzed, including the embedding depth, grit side length, etc. Results obtained show that the tensile stress with a 40% embedding depth is 292 MPa, which is the minimum on the bonding interface compared with other embedding depths. Meanwhile, the maximum tensile stress is 575 MPa, with an increase of 59% compared with that of a grit side length of 50 mm. Finally, the simulation results of the brazing residual stress of polycrystalline CBN abrasive grits have been con?rmed valid based on the residual stress measurement of the brazed monocrystalline CBN grit. 展开更多
关键词 Brazing residual stress Finite element analysis high-frequency induction heating Polycrystalline CBN grit
原文传递
Investigations of high-frequency induction hardening process for piston rod of shock absorber 被引量:1
2
作者 XianhuaCheng QianqianShangguan 《Journal of University of Science and Technology Beijing》 CSCD 2005年第1期85-89,共5页
The microhardness of piston rods treated with different induction hardening processes was tested. The experimental results reveal that the depth of the hardened zone is proportional to the ratio of the moving speed of... The microhardness of piston rods treated with different induction hardening processes was tested. The experimental results reveal that the depth of the hardened zone is proportional to the ratio of the moving speed of the piston rod to the output power of the induction generator. This result is proved correct through the Finite Element Method (FEM) simulation of the thermal field of induction heating. From tensile and impact tests, an optimized high frequency induction hardening process for piston rods has been obtained, where the output power was 82%×80 kW and the moving speed of workpiece was 5364 mm/min. The piston rods, treated by the optimized high frequency induction hardening process, show the best comprehensive mechanical performance. 展开更多
关键词 high-frequency induction hardening piston rod mechanical properties finite element method numerical simulation
在线阅读 下载PDF
High-Frequency Induction Heating of Needle-Shaped Mg-Ferrite for Ablation Therapy of Human Cancer
3
作者 NAOHARA Takashi AONO Hiromichi +3 位作者 MAEHARA Tsunehiro HIRAZAWA Hideyuki MATSUTOMO Shinya WATANABE Yuji 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2012年第S2期735-738,共4页
For application as a novel ablation therapy of human cancer,the heating property of a needle-shaped Mg-ferrite prepared by a sintering technique was studied in a high-frequency induction field at 370 kHz.When inserted... For application as a novel ablation therapy of human cancer,the heating property of a needle-shaped Mg-ferrite prepared by a sintering technique was studied in a high-frequency induction field at 370 kHz.When inserted into cylindrical clay,the increase in temperature(Δ7)was 31.2℃ for the specimen with a 1.5 mm diameter,while the 1.0mm diameter specimen exhibited a ΔT value of 15.7℃ after the induction time of 1200s.The ΔT exhibited a high value of 57.9℃ during the simultaneous insertion of 3 1.5mm diameter specimens.In the computer simulation images, the relatively lower magnetic flux density and concurrent neghgibly low current density were observed from the surface to the internal regions,being different from the behavior of a ferromagnetic Ni-rod with the same size. 展开更多
关键词 high-frequency induction heating cancer therapy ablation treatment eddy current loss residual loss
原文传递
Compressive Strength and Interface Microstructure of PCBN Grains Brazed with High-Frequency Induction Heating Method
4
作者 Ye-Jun Zhu Wen-Feng Ding +2 位作者 Ze-Yu Zhao Yu-Can Fu Hong-Hua Su 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2017年第7期641-649,共9页
In order to prepare monolayer brazed superabrasive wheels, the polycrystalline cubic boron nitride(PCBN)grains were brazed to AISI 1045 steel matrix with Ag–Cu–Ti filler alloy using the high-frequency induction he... In order to prepare monolayer brazed superabrasive wheels, the polycrystalline cubic boron nitride(PCBN)grains were brazed to AISI 1045 steel matrix with Ag–Cu–Ti filler alloy using the high-frequency induction heating technique. The compressive strengths of brazed grains were measured. Morphology, chemical composition and phase component of the brazing resultant around PCBN grain were also characterized. The results show that the maximum compressive strength of brazed grains is obtained in the case of brazing temperature of 965 °C, which does not decrease the original grain strength. Strong joining between Ag–Cu–Ti alloy and PCBN grains is dependent on the brazing resultants,such as TiB_2, TiN and AlTi_3, the formation mechanism of which is also discussed. Under the given experimental conditions, the optimum heating parameters were determined to be current magnitude of 24 A and scanning speed of0.5 mm/s. Finally, the brazing-induced residual tensile stress, which has a great influence on the grain fracture behavior in grinding, was determined through finite element analysis. 展开更多
关键词 high-frequency induction brazing PCBN grain Compressive strength Interface microstructure Residual stress
原文传递
High-frequency induction heated sintering of ball milled Fe-WC nanocomposites
5
作者 M. Zakeri T. Zanganeh A. Najafi 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2013年第7期693-699,共7页
Fe-WC nanocomposites were successfully fabricated by high-frequency induction heated sintering of ball milled nanostructure powders. The ball milled powders were characterized by X-ray diffraction. Density measurement... Fe-WC nanocomposites were successfully fabricated by high-frequency induction heated sintering of ball milled nanostructure powders. The ball milled powders were characterized by X-ray diffraction. Density measurements by the Archimedes method show that all sintered samples have the relative density higher than 95%. Studies on the effects of WC content, milling speed, and milling time indicate that a higher milling speed and a more WC content lead to the improvement of mechanical properties. There is a very good distribution of WC particles in the Fe matrix at the milling speed of 650 r/rain. For the sintered sample 20-5-650 (20wt% WC, milling time of 5 h, and milled speed of 650 r/min), the maximum Brinell hardness and yield stress are obtained to be 3.25 GPa and 858 MPa, respectively. All sintered samples have brittle fracture during compression test except the sample 20-5-650. 展开更多
关键词 NANOCOMPOSITES metallic matrix composites IRON tungsten carbide induction heating SINTERING mechanicalproperties
在线阅读 下载PDF
Outcomes of basiliximab vs alemtuzumab induction in kidney allograft recipients with matched immunological Profiles:A retrospective cohort study
6
作者 Chukwuma A Chukwu Philip A Kalra +3 位作者 Marcus Lowe Kay Poulton Titus Augustine Anirudh Rao 《World Journal of Transplantation》 2026年第1期182-192,共11页
BACKGROUND The use of induction immunosuppression agents has improved kidney transplant outcomes,but selecting the optimal agent remains a point of debate.AIM To compare the long-term outcomes of kidney transplant rec... BACKGROUND The use of induction immunosuppression agents has improved kidney transplant outcomes,but selecting the optimal agent remains a point of debate.AIM To compare the long-term outcomes of kidney transplant recipients receiving alemtuzumab vs basiliximab induction,focusing on graft function,acute rejection,infection,malignancy,post-transplant glomerulonephritis,and survival,using a propensity score matched cohort design.METHODS Kidney transplant recipients who received alemtuzumab or basiliximab induction from 2014 to 2019 across two nephrology centres in Northwest England were evaluated.Propensity score matching at a 1:1.5 ratio ensured comparability between cohorts.Baseline characteristics,immunosuppression regimens,and outcomes were analyzed.Linear,binary logistic and Cox proportional hazard regression models.RESULTS A total of 436 recipients were included,with a median follow-up of 5.2 years.The matched cohort(n=262)had a mean age of 51.1±13.5 years;39%were female and 92%were white.There was no significant difference in the cumulative incidence of acute rejection[odds ratio(OR)=2.10;95%CI:0.9-4.9;P=0.110].Compared with basiliximab,alemtuzumab was associated with lower estimated glomerular filtration rate at 12 months(-6.6 mL/minute/1.73 m2;95%CI:-10.5 to-2.7;P<0.001)and higher risks of cytomegalovirus viremia(OR=3.2;95%CI:1.6-6.5;P<0.001),BK viremia(OR=2.4;95%CI:1.1-5.5;P=0.02),post-transplant malignancy(OR=6.2;95%CI:1.6-29.9;P=0.013),and death-censored graft loss(hazard ratio=3.6;95%CI:1.2-11.4;P=0.03).No significant differences were observed in post-transplant glomerulonephritis or recipient mortality.CONCLUSION In this propensity score-matched analysis,alemtuzumab induction was associated with lower graft function at 12 months and higher risks of viral infection,post-transplant malignancy,and graft loss compared with basiliximab.These findings highlight the need for further studies to confirm the long-term safety and effectiveness of alemtuzumab in kidney transplantation. 展开更多
关键词 Kidney transplantation Immunosuppression induction ALEMTUZUMAB BASILIXIMAB Graft outcomes
暂未订购
Induction therapy in kidney transplant recipients:A consensus statement of Indian Society of Organ Transplantation
7
作者 Vivek B Kute Manish Ramesh Balwani +25 位作者 Jigar B Shrimali Amit Pasari Vijay Kher Mohan Punabhai Patel Deodatta Chafekar Swarnalata Guditi Pratik Das Gireesh Mathihally Siddaiah Suraj Mohan Godara Vinant Bhargava Anurag Gupta Vishal Ramteke Nishant Deshpande Priyanka Tolani Narayan Prasad Radhika Krishna Patil Ravi Mohanka Sandeep Mahajan Sourabh Sharma Subho Banerjee Divyesh P Engineer Dhananjai Agarwal Pranjal Kashiv Arpita Lahiri Dinesh Khullar Aneesh Srivastava 《World Journal of Transplantation》 2026年第1期17-31,共15页
Kidney transplantation(KT)accounts for nearly three-fourths of organ transplants in India,with living donors contributing to 82%of cases.Induction immunosuppression is essential to optimize initial immunosuppression,r... Kidney transplantation(KT)accounts for nearly three-fourths of organ transplants in India,with living donors contributing to 82%of cases.Induction immunosuppression is essential to optimize initial immunosuppression,reduce acute rejections,and enable tailored use of maintenance agents.Rabbit anti-thymocyte globulin(rATG)and interleukin-2 receptor anatagonists(IL-2RA/IL-2RBs)are the most widely used induction therapies.However,data on induction practices across India are limited.To evaluate induction immunosuppression practices across KT centers in India and establish a consensus for different subsets of KT recipients.A nationwide online survey was conducted by the Indian Society of Organ Transplantation(ISOT)among its members(400 KT centers).Responses were analyzed to assess induction practices across diverse donor types,age groups,and immunological risk profiles.Heterogeneity in practices prompted consensus building using a modified Delphi process.Literature review and expert panel discussions(April 2024)were followed by structured voting,and 16 consensus statements were finalized.Of 400 centers approached,254 participated.rATG was the most commonly used induction therapy,followed by IL-2RBs;alemtuzumab was least used.Significant heterogeneity was observed in type,dose,and duration of induction therapy.Consensus recommendations were framed:rATG for high immunological risk recipients and deceased donor KTs;IL-2RB or low-dose rATG for low immunological risk;rituximab in ABOincompatible KTs;and tailoring based on age,diabetes,donor type,infection risk,and affordability.This first ISOT consensus provides 16 India-specific statements on induction therapy in KT.It emphasizes risk-stratified,evidenceinformed,and context-appropriate induction strategies,supporting standardization of care across the country. 展开更多
关键词 Kidney transplant induction therapy Rabbit anti-thymocyte globulin IL-2 receptor blockers RITUXIMAB CONSENSUS Indian Society of Organ Transplantation
暂未订购
Study on High-frequency Callus Induction From Aseptic Plantlets of Anthuium andraeanum
8
作者 Xiuxiu LI Siyu ZHOU +2 位作者 Siyu ZHU Le GAO Jianzhong TAN 《Agricultural Biotechnology》 CAS 2019年第4期39-41,47,共4页
[Objectives]This study was conducted to improve the efficiency of callus induction and redifferentiation,and construct high-frequency plant regeneration techniques of tissue culture in Anthuium andraeanum.[Methods]The... [Objectives]This study was conducted to improve the efficiency of callus induction and redifferentiation,and construct high-frequency plant regeneration techniques of tissue culture in Anthuium andraeanum.[Methods]The effects of different genotypes,explant types and hormonal conditions on callus induction and re-differentiation of A.andraeanum were studied by using the aseptic A.andraeanum test-tube plantlets as test materials.[Results]Among the four kinds of aseptic A.andraeanum plantlets,the callus induction using stem segments with leaves was the best,followed by stem segments and leaves,and the petioles were the worst;among the six A.andraeanum varieties tested,the callus production rates of four varieties reached 100%;and the callus differentiation rate reached 93.3%-100%through the organogenesis pathway,and the suitable differentiation medium was 1/2MS+ZT 0.5 mg/L+2,4-D 0.1 mg/L.[Conclusions]The research results provide a new experimental basis for optimizing the technical system of A.andraeanum rapid propagation. 展开更多
关键词 Anthuium andraeanum EXPLANT type CALLUS induction CYTOKININ Adventitious BUD
在线阅读 下载PDF
Design and Parametric Optimization of a Doublesided Linear Induction Motor for Hyperloop Pod 被引量:1
9
作者 Bahaddin Goksun Ismet Sen +3 位作者 Musap Kuzucu Bati Eren Ergun Ilhan Kocaarslan Mehmet Onur Gulbahce 《CES Transactions on Electrical Machines and Systems》 2025年第1期36-45,共10页
The hyperloop idea,which is one of the most ecofriendly,low-carbon emissions,and fossil fuel-efficient modes of transportation,has recently become quite popular.In this study,a double-sided linear induction motor(LIM)... The hyperloop idea,which is one of the most ecofriendly,low-carbon emissions,and fossil fuel-efficient modes of transportation,has recently become quite popular.In this study,a double-sided linear induction motor(LIM)with 500 W of output power,60 N of thrust force and 200 V/38.58 Hz of supply voltage was designed to be used in hyperloop development competition hosted by the scientific and technological research council of turkey(TüB?TAK)rail transportation technologies institute(RUTE).In contrast to the studies in the literature,concentrated winding is preferred instead of distributed winding due to mechanical constraints.The electromagnetic design of LIM,whose mechanical and electrical requirements were determined considering the hyperloop development competition,was carried out by following certain steps.Then,the designed model was simulated and analyzed by finite element method(FEM),and the necessary optimizations have been performed to improve the motor characteristics.By examining the final model,the applicability of the concentrated winding type LIM for hyperloop technology has been investigated.Besides,the effects of primary material,railway material,and mechanical air-gap length on LIM performance were also investigated.In the practical phase of the study,the designed LIM has been prototyped and tested.The validation of the experimental results was achieved through good agreement with the finite element analysis results. 展开更多
关键词 Finite element analysis(FEA) Hyperloop Linear induction motor(LIM) Motor design
在线阅读 下载PDF
An experimental and computational investigation on structural evolution of the In_(2)O_(3)catalyst during the induction period of CO_(2)hydrogenation 被引量:1
10
作者 Zhangqian Wei Mingxiu Wang +6 位作者 Xinnan Lu Zixuan Zhou Ziqi Tang Chunran Chang Yong Yang Shenggang Li Peng Gao 《Chinese Journal of Catalysis》 2025年第5期301-313,共13页
As one of the most important industrially viable methods for carbon dioxide(CO_(2))utilization,methanol synthesis serves as a platform for production of green fuels and commodity chemicals.For sustainable methanol syn... As one of the most important industrially viable methods for carbon dioxide(CO_(2))utilization,methanol synthesis serves as a platform for production of green fuels and commodity chemicals.For sustainable methanol synthesis,In_(2)O_(3)is an ideal catalyst and has garnered significant attention.Herein,cubic In_(2)O_(3)nanoparticles were prepared via the precipitation method and evaluated for CO_(2)hydrogenation to produce methanol.During the initial 10 h of reaction,CO_(2)conversion gradually increased,accompanied by a slow decrease of methanol selectivity,and the reaction reached equilibrium after 10-20 h on stream.This activation and induction stage may be attributed to the sintering of In_(2)O_(3)nanoparticles and the creation of more oxygen vacancies on In_(2)O_(3)surfaces.Further experimental studies demonstrate that hydrogen induction created additional oxygen vacancies during the catalyst activation stage,enhancing the performance of In_(2)O_(3)catalyst for CO_(2)hydrogenation.Density functional theory calculations and microkinetic simulations further demonstrated that surfaces with higher oxygen vacancy coverages or hydroxylated surfaces formed during this induction period can enhance the reaction rate and increase the CO_(2)conversion.However,they predominantly promote the formation of CO instead of methanol,leading to reduced methanol selectivity.These predictions align well with the above-mentioned experimental observations.Our work thus provides an in-depth analysis of the induction stage of the CO_(2)hydrogenation process on In_(2)O_(3)nano-catalyst,and offers valuable insights for significantly improving the CO_(2)reactivity of In_(2)O_(3)-based catalysts while maintaining long-term stability. 展开更多
关键词 In_(2)O_(3) CO_(2)hydrogenation Methanol production induction and activation Structural evolution
在线阅读 下载PDF
Impact of Handshake and Information Support on Patients’ Physiological and Psychological States before Anesthesia Induction for Laparoscopic Cholecystectomy
11
作者 Yi Liu Jing Wang +3 位作者 Xiangying Pi Zumei Gao Xiaohui Li Qian Sun 《Journal of Biosciences and Medicines》 2025年第2期58-66,共9页
Objective: This study evaluates the impact of handshake and information support on patients’ outcomes during laparoscopic cholecystectomy. It examines the effects on their physiological and psychological responses an... Objective: This study evaluates the impact of handshake and information support on patients’ outcomes during laparoscopic cholecystectomy. It examines the effects on their physiological and psychological responses and overall satisfaction with nursing care. Methods: A total of 84 patients scheduled for laparoscopic cholecystectomy were selected through convenient sampling and randomly assigned to either the control group or the intervention group using a random number table. Each group consisted of 42 patients. The control group received standard surgical nursing care. In addition to standard care, the intervention group received handshake and information support from the circulating nurse before anesthesia induction. Vital signs were recorded before surgery and before anesthesia induction. Anxiety levels were measured using the State-Trait Anxiety Inventory (STAI) and the State-Anxiety Inventory (S-AI), while nursing satisfaction was assessed using a numerical rating scale. Results: No significant differences were found between the two groups in systolic and diastolic blood pressures before surgery and anesthesia induction (P > 0.05). However, there was a significant difference in heart rate before anesthesia induction (P Conclusion: Providing handshake and information support before anesthesia induction effectively reduces stress, alleviates anxiety, and enhances comfort and satisfaction among patients undergoing laparoscopic cholecystectomy. 展开更多
关键词 HANDSHAKE Information Support Anesthesia induction Preoperative Anxiety
暂未订购
Multi-Objective Dynamic Induction Research of Ship Routes in the Context of Low Carbon Shipping
12
作者 He Zhang Junfeng Dong Siyuan Kong 《哈尔滨工程大学学报(英文版)》 2025年第3期593-605,共13页
To improve the efficiency of ship traffic in frequently traded sea areas and respond to the national“dual-carbon”strategy,a multi-objective ship route induction model is proposed.Considering the energy-saving and en... To improve the efficiency of ship traffic in frequently traded sea areas and respond to the national“dual-carbon”strategy,a multi-objective ship route induction model is proposed.Considering the energy-saving and environmental issues of ships,this study aims to improve the transportation efficiency of ships by providing a ship route induction method.Ship data from a certain bay during a defined period are collected,and an improved backpropagation neural network algorithm is used to forecast ship traffic.On the basis of the forecasted data and ship route induction objectives,dynamic programming of ship routes is performed.Experimental results show that the routes planned using this induction method reduce the combined cost by 17.55%compared with statically induced routes.This method has promising engineering applications in improving ship navigation efficiency,promoting energy conservation,and reducing emissions. 展开更多
关键词 Dynamic route induction Low-carbon shipping Short-term vessel flow prediction Multi-objective induction model Maritime transport efficiency
在线阅读 下载PDF
A novel logging method for detecting highly resistive formations in oil-based mud using high-frequency electrodes
13
作者 Kang-Kang Wu Lei Wang +1 位作者 Shao-Gui Deng Xue-Wen Kou 《Petroleum Science》 2025年第5期1946-1958,共13页
The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel l... The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel logging method for detection of high-resistance formations in OBM using highfrequency electrodes. The method addresses the issue of shallow depth of investigation(DOI) in existing electrical logging instruments, while simultaneously ensuring the vertical resolution. Based on the principle of current continuity, the total impedance of the loop is obtained by equating the measurement loop to the series form of a capacitively coupled circuit. and its validity is verified in a homogeneous formation model and a radial two-layer formation model with a mud standoff. Then, the instrument operating frequency and electrode system parameters were preferentially determined by numerical simulation, and the effect of mud gap on impedance measurement was investigated. Subsequently, the DOI of the instrument was investigated utilizing the pseudo-geometric factor defined by the real part of impedance. It was determined that the detection depth of the instrument is 8.74 cm, while the effective vertical resolution was not less than 2 cm. Finally, a focused high-frequency electrode-type instrument was designed by introducing a pair of focused electrodes, which effectively enhanced the DOI of the instrument and was successfully deployed in the Oklahoma formation model. The simulation results demonstrate that the novel method can achieve a detection depth of 17.40 cm in highly-resistive formations drilling with OBM, which is approximately twice the depth of detection of the existing oil-based mud microimager instruments. Furthermore, its effective vertical resolution remains at or above 2 cm,which is comparable to the resolution of the existing OBM electrical logging instrument. 展开更多
关键词 Oil-based mud Highly-resistive high-frequency electrode Bulking electrode Depth of investigation
原文传递
Evaluation of the Effectiveness, Accuracy, Specificity, and Sensitivity of High-Frequency Ultrasound in Differentiating Benign and Malignant Breast Micronodules
14
作者 Danhong Yan Weimin Li Hongtao Duan 《Journal of Clinical and Nursing Research》 2025年第9期370-376,共7页
Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between Octob... Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between October 2022 and October 2024 were selected for high-frequency ultrasound diagnosis.The diagnostic efficacy of high-frequency ultrasound was evaluated by comparing it with the results of surgical pathology.Results:High-frequency ultrasound detected 50 benign nodules,primarily breast fibroadenomas,and 35 malignant nodules,mainly breast ductal carcinoma in situ.Based on surgical pathology results,the diagnostic accuracy of high-frequency ultrasound was 96.47%,specificity was 97.96%,and sensitivity was 94.44%.In high-frequency ultrasound diagnosis,the proportion of grade III and IV blood flow in malignant nodules was higher than that in benign nodules,while the proportion of regular shape and clear margins was lower.The proportion of microcalcifications and posterior echo attenuation was higher in malignant nodules,and the resistance index(RI)and peak blood flow velocity were lower than those in benign nodules(P<0.05).Conclusion:High-frequency ultrasound can effectively differentiate benign and malignant breast micronodules,determine specific nodule types,and exhibits high diagnostic accuracy and sensitivity.Additionally,benign and malignant nodules can be differentiated based on the grading of blood flow signals,sonographic features,and blood flow velocity,providing reasonable guidance for subsequent treatment plans. 展开更多
关键词 high-frequency ultrasound Breast micronodules Differentiating benign and malignant ACCURACY Sensitivity
暂未订购
In vivo Haploid Induction via Parthenogenesis Gene ToPAR in Rice
15
作者 XIONG Jie JI Yajie +3 位作者 YANG Shenlin QIU Xianjin QIAN Qian WANG Kejian 《Rice science》 2025年第3期273-276,I0001-I0004,共8页
Doubled haploid(DH)technology has revolutionized crop breeding by enabling the production of homozygous lines in a single generation.In vivo haploid induction(HI)offers a more widely applicable approach that can signi... Doubled haploid(DH)technology has revolutionized crop breeding by enabling the production of homozygous lines in a single generation.In vivo haploid induction(HI)offers a more widely applicable approach that can significantly improve DH breeding efficiency.ToPAR,a parthenogenesis gene,originally identified in dandelion(Taraxacum officinale),has been characterized.Researchers have successfully induced haploid embryo-like structures and haploid offspring in lettuce and foxtail millet,respectively. 展开更多
关键词 parthenogenesis geneoriginally RICE vivo haploid induction vivo haploid induction hi offers PARTHENOGENESIS topar production homozygous lines foxtail milletrespectively
在线阅读 下载PDF
Study on the Characteristics of High-Frequency Electromagnetic Wave Detection in Goaf Areas along Coal Seam Boreholes
16
作者 Maolin Yang 《Journal of Environmental & Earth Sciences》 2025年第7期272-284,共13页
China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and dis... China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and discontinuous,and there is no definite geological law to follow,which seriously threatens the safety of coal mine production and personnel life.Conventional ground geophysical methods have low accuracy in detecting goaf areas affected by mechanical interference from open-pit mines,especially for waterless goaf areas,which cannot be detected by existing methods.This article proposes the use of high-frequency electromagnetic waves for goaf detection.The feasibility of using drilling radar to detect goaf was theoretically analyzed,and a goaf detection model was established.The response characteristics of different fillers in the goaf under different frequencies of high-frequency electromagnetic waves were simulated and analyzed.In a certain open-pit mine in Inner Mongolia,100MHz high-frequency electromagnetic waves were used to detect the goaf through directional drilling on the ground.After detection,excavation verification was carried out,and the location of one goaf detected was verified.The results of engineering practice show that the application of high-frequency electromagnetic waves in goaf detection expands the detection radius of boreholes,has the advantages of high efficiency and accuracy,and has important theoretical and practical significance. 展开更多
关键词 Underground Coal Mine GOAF high-frequency Electromagnetic Wave(HFEW) BOREHOLE
在线阅读 下载PDF
A review on high-frequency electromagnetic interference induced by power electronics in new electric power systems
17
作者 Yundong Hu Xing Lei +3 位作者 Xizhou Du Ting Ye Hongning Song Hao Li 《Global Energy Interconnection》 2025年第5期804-820,共17页
New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed s... New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed switching of power converters.To address this situation,this paper offers an in-depth review of HF interference problems and challenges originating from power electronic devices.First,the root cause of HF electromagnetic interference,i.e.,the resonant response of the parasitic parameters of the system to high-speed switching transients,is analyzed,and various scenarios of HF interference in power systems are highlighted.Next,the types of HF interference are summarized,with a focus on common-mode interference in grounding systems.This paper thoroughly reviews and compares various suppression methods for conducted HF interference.Finally,the challenges involved and suggestions for addressing emerging HF interference problems from the perspective of both power electronics equipment and power systems are discussed.This review aims to offer a structured understanding of HF interference problems and their suppression techniques for researchers and practitioners. 展开更多
关键词 New power system Power electronics Switching transients high-frequency interference Common-mode interference suppression
在线阅读 下载PDF
High-frequency enhanced ultrafast compressed active photography
18
作者 Yizhao Meng Yu Lu +5 位作者 Pengfei Zhang Yi Liu Fei Yin Lin Kai Qing Yang Feng Chen 《Opto-Electronic Advances》 2025年第1期32-43,共12页
Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the ra... Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the random code(Rcode)used in traditional UCI will lead to low-frequency noise covering high-frequency information due to its uneven sampling interval,which is a great challenge in the fidelity of large-frame reconstruction.Here,a high-frequency enhanced compressed active photography(H-CAP)is proposed.By uniformizing the sampling interval of R-code,H-CAP capture the ultrafast process with a random uniform sampling mode.This sampling mode makes the high-frequency sampling energy dominant,which greatly suppresses the low-frequency noise blurring caused by R-code and achieves high-frequency information of image enhanced.The superior dynamic performance and large-frame reconstruction ability of H-CAP are verified by imaging optical self-focusing effect and static object,respectively.We applied H-CAP to the spatial-temporal characterization of double-pulse induced silicon surface ablation dynamics,which is performed within 220 frames in a single-shot of 300 ps.H-CAP provides a high-fidelity imaging method for observing ultrafast unrepeatable dynamic processes with large frames. 展开更多
关键词 ultrafast compressed imaging high-frequency enhanced sampling spectral-temporal transform transient processes high-fidelity reconstruction
在线阅读 下载PDF
Effectiveness of High-Frequency Electrosurgical Knife Surgery Under Painless Digestive Endoscopy in Elderly Patients with Gastrointestinal Polyps
19
作者 Yumin Lu 《Proceedings of Anticancer Research》 2025年第1期14-20,共7页
Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderl... Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderly GP patients admitted between June 2021 and December 2022 were selected.Patients were randomly divided into two groups:the painless group(50 cases)underwent high-frequency electrosurgical knife surgery guided by PDE,while the conventional group(50 cases)underwent the same surgery guided by traditional digestive endoscopy(DE).The total treatment efficacy,perioperative indicators,gastrointestinal hormone levels,oxidative stress(OS)markers,and complication rates were compared between the two groups.Results:The total treatment efficacy in the painless group was higher than that in the conventional group,and perioperative indicators were superior in the painless group(P<0.05).One week after treatment,the gastrointestinal hormone levels and OS-related markers in the painless group were better than those in the conventional group(P<0.05).The complication rate in the painless group was lower than in the conventional group(P<0.05).Conclusion:High-frequency electrosurgical knife surgery guided by PDE improves the effectiveness of polyp removal in elderly GP patients and accelerates postoperative recovery.It also protects gastrointestinal function,reduces postoperative OS,and ensures higher surgical safety. 展开更多
关键词 Painless digestive endoscopy high-frequency electrosurgical knife surgery Elderly gastrointestinal polyps
暂未订购
Magnetic Induction Communication in Extreme Environments:Principles,Technologies,and Challenges
20
作者 Jiang Tao Zhang Yixin Liu Guanghua 《China Communications》 2025年第1期256-264,共9页
Wireless communications in extreme environments,such as underwater and underground,is an essential technology for interconnecting various devices and enables data transmission and networking.Existing wireless technolo... Wireless communications in extreme environments,such as underwater and underground,is an essential technology for interconnecting various devices and enables data transmission and networking.Existing wireless technologies using electromagnetic(EM)waves face many known problems,such as high path loss,unpredictable multi-path fading,and large antenna size in the lossy medium.In this article,the magnetic induction(MI)based physical layer communication is introduced as a promising solution for wireless transmissions in extreme environments.Specifically,the fundamentals of the MI-based communications are reviewed.Then,with the goal of establishing reliable and low-power links between small-size devices,we review several key physical layer technologies for MI-based communications,including the MIbased signal modulations,magnetic beamforming,and relay transmissions,and summarize their state-of-theart research advances.Finally,the related open issues and challenges in each area are analyzed and presented for future investigations. 展开更多
关键词 BEAMFORMING magnetic induction communications relay transmission signal modulation
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部