期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Failure Analysis of Ceramic Substrates Used in High Power IGBT Modules
1
作者 Zenjebil Jouini Zarel Valdez-Nava David Malec 《Engineering(科研)》 2016年第9期561-571,共11页
High voltage power modules are used in numerous applications to build high power converters. Technically, these modules are made of different materials and among them, dielectric materials are organic and inorganic. O... High voltage power modules are used in numerous applications to build high power converters. Technically, these modules are made of different materials and among them, dielectric materials are organic and inorganic. Organic insulators (gels) are used to avoid corona discharges in the vicinity of connecting wires and high voltage dies (diodes and transistors) and to protect them from moisture and contaminants. Inorganic insulators (ceramic substrates) are used to insulate the high voltage which dies from the grounded elements and to transfer heat to the heat sink. Despite being used since the late 90s, there is a lack of fundamental knowledge about the electrical properties of these substrates. Consequently, manufacturers tend to assure the reliability by over sizing them. As there are no clear rules for how to do that, failures occur, leading to the converter shutdown. The aim of this study is to bring new information about the understanding of the dielectric strength of ceramic materials used in these modules. We have focused our work on the correlation between the mechanical and the dielectric properties of ceramics by using relevant experiments. We provide new information about the impact of existing cracks on the ceramic dielectric failure, according to the electromechanical breakdown model. Our conclusions bring crucial information about the precautions to be taken during manufacturing and implementation of these substrates in power modules to reduce the likelihood of the particular causes of failure. 展开更多
关键词 high voltage Power module Ceramic Substrate Dielectric Strength Electro-Mechanical Breakdown
在线阅读 下载PDF
The Design of TZ-2 High Voltage Pulse Modulator
2
作者 WANG Mingwei KANG Zihua LI Xiujuan ZHENG Tieliu WANG Xuehua LI Bo FENG Kun 《Southwestern Institute of Physics Annual Report》 2005年第1期69-70,共2页
There are a few assistant heating objects included electron cyclotron resonate heating ( ECRH ). Two 500 kW gyrotrons introduced from Russia were operated to launch 1 MW energy. So two set of TZ-2 high voltage puls... There are a few assistant heating objects included electron cyclotron resonate heating ( ECRH ). Two 500 kW gyrotrons introduced from Russia were operated to launch 1 MW energy. So two set of TZ-2 high voltage pulse modulators are needed. 展开更多
关键词 high voltage pulse Modulator
在线阅读 下载PDF
Partial Discharge Measurement and Analysis in High Voltage IGBT Modules Under DC Voltage 被引量:17
3
作者 Pengyu Fu Zhibin Zhao +4 位作者 Xiang Cui Teng Wen Haoyu Wang Xuebao Li Peng Zhang 《CSEE Journal of Power and Energy Systems》 SCIE 2018年第4期513-523,共11页
Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of ... Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module. 展开更多
关键词 DC voltage high voltage IGBT module insulation performance partial discharge measurement waveform analysis wideband time domain measurement
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部