Objective Cardiovascular complications contribute to postoperative morbidity and mortality in elderly hip fracture patients. Limited data are available regarding which preoperative risk factors predict cardiovascular ...Objective Cardiovascular complications contribute to postoperative morbidity and mortality in elderly hip fracture patients. Limited data are available regarding which preoperative risk factors predict cardiovascular course following hip fracture surgery (HFS). We used high sensitive troponin I (hs-TnI) assays and clinical parameters to identify preoperative risk factors associated with major adverse cardiac events (MACE) in elderly hip frac^u'e patients. Method From August 2014 to November 2016, 575 patients with hip fracture were enrolled in a retrospective, single-center registry. A total of 262 of these patients underwent HFS and hs-TnI assays. MACE was defined as postoperative all-cause deaths, heart failure (HF), new-onset atrial fibrillation (AF), myocardial infarction (MI) and cardiovascular re-hospitalization that occurred within 90 days postoperative. Results Of 262 HFS patients, MACE developed following HFS in 65 (24.8%). Patients with MACE were older and had higher rates of renal insufficiency, coronary artery disease, prior HF, low left ventricular ejection fraction and use of beta blockers; higher levels of hs-Tnl and N-terminal pro-brain natriuretic peptide (NT-proBNP) and higher revised cardiac risk index. A preoperative hs-TnI≥ 6.5 ng/L was associated with high risk of postoperative HF, new-onset AF and MACE. In multivariable analysis, pre-operative independent predictors for MACE were age 〉 80 years [adjusted hazard ratio (HR): 1.79, 95% confident interval (CI): 1.03-3.13, P = 0.04], left ventricular ejection fraction (LVEF) 〈 50% (adjusted HR: 3.17, 95% CI: 1.47-5.82, P 〈 0.01) and hs-TnI 〉 6.5 ng/L (adjusted HR: 3.75, 95% CI: 2.09~5.17, P 〈 0.01). Conclusion In elderly patients with hip fracture who undergo HFS, a preoperative assessment of hs-TnI may help the risk refinement of cardiovascular complications.展开更多
Objective:Percutaneous coronary intervention(PCI) triggers an acute inflammatory response,while sirolimus is known to have anti-inflammatory properties;the inflammatory system response to PCI after sirolimus-eluting s...Objective:Percutaneous coronary intervention(PCI) triggers an acute inflammatory response,while sirolimus is known to have anti-inflammatory properties;the inflammatory system response to PCI after sirolimus-eluting stent placement remains unclear.The purpose of this study is to determine the changes in high sensitive C-reactive protein(hs-CRP) and apelin after PCI procedure and drug-eluting stent implantation in patients with and without reduced left ventricular systolic function.Methods:Forty-eight consecutive patients undergoing PCI at the Beijing Anzhen Hospital between July and September 2006 were recruited.Sirolimus-eluting stents were employed in all patients.Blood samples were drawn immediately before and 24 h after the procedure.Plasma hs-CRP and apelin levels were determined by enzyme immunoassay.Results:Paired t-test revealed a significant increase in both hs-CRP and apelin post-procedure(P=0.006 and P<0.0001,respectively).Patients with reduced left ventricular ejection fraction(LVEF) had significantly lower baseline apelin levels compared to those with normal ventricular function [(46.8±10.8) vs.(72.0±8.4) pg/ml,P<0.001].However,apelin increased to a level similar to the level of those with normal left ventricular systolic function 24 h after the PCI procedure [(86.7±11.6) vs.(85.1±6.1) pg/ml,P=0.72].Conclusions:hs-CRP and apelin levels increased after PCI and sirolimus-eluting stent implantation.Patients with impaired left ventricular systolic function had significantly lower baseline apelin levels,which increased significantly after PCI.展开更多
This study was undertaken to investigate the correlation of the enhancement degree on contrast-enhanced ultrasound(CEUS) with the histopathology of carotid plaques and the serum high sensitive C-reactive protein(hs-CR...This study was undertaken to investigate the correlation of the enhancement degree on contrast-enhanced ultrasound(CEUS) with the histopathology of carotid plaques and the serum high sensitive C-reactive protein(hs-CRP) levels in patients undergoing carotid endarterectomy(CEA). Carotid CEUS was performed preoperatively in 115 patients who would undergo CEA, and the enhancement degree of the carotid plaques was evaluated by both the visual semiquantitative analysis and the quantitative time-intensity curve analysis. Serum hs-CRP levels were detected using the particle-enhanced immunoturbidimetric assay also before the operation. Additionally, the carotid plaque samples were subjected to histopathological examination postoperatively. The density of neovessels and the number of macrophages in the plaques were assessed by immunohistochemistry. The results showed that among the 115 patients, grade 0 plaque contrast enhancement was noted in 35 patients, grade 1 in 48 patients and grade 2 in 32 patients. The degree of plaque enhancement, the density of neovessels, the number of macrophages, and the hs-CRP levels were highest in the grade 2 patients. Correlation analysis showed that the enhancement degree of the carotid plaques was closely related to the immunohistochemical parameters of the plaques and the serum hs-CRP levels. It was suggested that the carotid plaque enhancement on CEUS can be used to evaluate the vulnerability of carotid plaques.展开更多
Objective To evaluate the effects of simvastatin combined with omega-3 fatty acids on high sensitive C-reactive protein(HsCRP), lipidemia, and fibrinolysis in coronary heart disease (CHD) and CHD risk equivalent patie...Objective To evaluate the effects of simvastatin combined with omega-3 fatty acids on high sensitive C-reactive protein(HsCRP), lipidemia, and fibrinolysis in coronary heart disease (CHD) and CHD risk equivalent patients with mixed dyslipi-demia. Methods A randomized, double-blind placebo controlled and parallel group trial was conducted. Patients with CHD and CHD risk equivalents with mixed dyslipidemia were treated with 10 or 20 mg simvastatin for 6-12 weeks. Following with the treatment of patients whose low-density lipoprotein cholesterol (LDL-ch) reaching goal level (< 100 mg/dL) or close to the goal (< 130 mg/dL), while triglyceride (TG) ≥200 mg/dL and < 500 mg/dL, was combined with omega-3 fatty acids (3 g/d) or a placebo for 2 months. The effects of the treatment on HsCRP, total cholesterol (TC), LDL-ch, high-density lipoprotein cholesterol (HDL-ch), TG, lipoprotein (a) [LP (a)], apolipoprotein A1 (apoA1), apolipoprotein B (apoB), plasminogen activator inhibitor-1 (PAI-1), and tissue plasminogen activator (tPA) were investigated. Forty patients finished the study with each group consisting of twenty patients. Results (1) There were significant reductions of HsCRP, TG, TC, and TC/HDL-ch, which decreased by 2.16 ±2.77 mg/L (38.5%), 94.0 ±65.4 mg/dL (31.1%), 13.3 ±22.3 mg/dL (6.3%), 0.78 ±1.60 respectively in the omega-3 fatty acids group (P< 0.01, < 0.001, < 0.05, < 0.05) compared to the baseline. HsCRP and triglyceride reduction were more significant in omega-3 fatty acids group compared to the placebo group (P=0.021 and 0.011 respectively). (2) In the omega-3 fatty acids group, the values and percentage of TG reduction had a significantly positive relation with HsCRP reduction (r=0.51 and 0.45, P=0.021 and 0.047 respectively). Conclusion In CHD and CHD risk equivalent patients with mixed dyslipidemia, dyslipidemia’s therapeutic effect using simvastatin and omega-3 fatty acids may result from not only the combination of lipid adjustment, but also enhancement of their own nonlipid influences.展开更多
Chiral metamaterials have been a topic of significant research interest in recent years due to their potential for various applications in nanophotonic devices and chiral biosensors.However,the intrinsic Ohmic loss in...Chiral metamaterials have been a topic of significant research interest in recent years due to their potential for various applications in nanophotonic devices and chiral biosensors.However,the intrinsic Ohmic loss in surface plasmonic resonance has limited their practical use,resulting in large light dissipation and weak chiroptical resonance.Here,we report on the development of high-performance dielectric chiral shells(DCS)through a two-step Si deposition process on a self-assembled microsphere monolayer.The form DCS sample completely oyercomes the cancelation effect originated from the disorder property of the micro-sphere monolayer in macroscale,and at a wavelength of approximately 710 nm,the measured optimal chiral signal(g-factor)and transmittance can reach up to 0.7 and 0.3,respectively.The strong chiroptical effect comes from the asymmetric circular displacement currents(i.e.,magnetic modes)enabled by the specific shell geometry.The chiral shell geometry,electromagnetic properties,sensor sensitivity of chiral molecules and figure of merit are systematically investigated.The DCSs demonstrate highly sensitive detection of chiral biomolecules owing to their easily accessible geometry and enhanced uniform chiral field.展开更多
To achieve a lower detection limit has always been a goal of analytical chemists.Herein,we demonstrate the first picomolar level detection capability for Fe3+ion via luminescence detection technology.The results of st...To achieve a lower detection limit has always been a goal of analytical chemists.Herein,we demonstrate the first picomolar level detection capability for Fe3+ion via luminescence detection technology.The results of structural analysis and theoretical calculation show that Fe3+ions are adsorbed on the central node of Eu-DBM(DBM=dibenzoylmethane)sensor in the form of single ion at ultralow concentration.Subsequently,the pathways of photo-induced charge and energy transfer of the obtained Eu-DBM@Fe^(3+)material have been changed,from the initial DBM-to-Eu^(3+)before Fe^(3+)adsorption to the ultimate DBM-to-Fe^(3+)after adsorption process,which quenches the luminescence of Eu3+ion.This work not only obtains the highly sensitive luminescence detection ability,but also innovatively proposes the single-ion adsorption mechanism,both of which have important scientific and application values for the development of more efficient detection agents in the future.展开更多
Flexible pressure sensors show great promise for applications in such fields as electronic skin,healthcare,and intelligent robotics.Traditional capacitive pressure sensors,however,face the problem of low sensitivity,w...Flexible pressure sensors show great promise for applications in such fields as electronic skin,healthcare,and intelligent robotics.Traditional capacitive pressure sensors,however,face the problem of low sensitivity,which limits their wider application.In this paper,a flexible capacitive pressure sensor with microstructured ionization layer is fabricated by a sandwich-type process,with a low-cost and simple process of inverted molding with sandpapers being used to form a thermoplastic polyurethane elastomer ionic film with double-sided microstructure as the dielectric layer of the sensor,with silver nanowires as electrodes.The operating mechanism of this iontronic pressure sensor is analyzed using a graphical method,and the sensor is tested on a pressure platform.The test results show that the sensor has ultrahigh pressure sensitivities of 3.744 and 1.689 kPa^(−1) at low(0-20 kPa)and high(20-800 kPa)pressures,respectively,as well as a rapid response time(100 ms),and it exhibits good stability and repeatability.The sensor can be used for sensitive monitoring of activities such as finger bending,and for facial expression(smile,frown)recognition,as well as speech recognition.展开更多
High-sensitivity sensors represent a critical frontier in modern sensing technology,driving innovations across fields such as biomedical monitoring,precision instrumentation,environmental detection,and indus-trial aut...High-sensitivity sensors represent a critical frontier in modern sensing technology,driving innovations across fields such as biomedical monitoring,precision instrumentation,environmental detection,and indus-trial automation.As demands for accuracy,miniaturization,and reliability continue to grow,developing novel sensor architectures and functional materials has become essential to achieving enhanced performance under extreme or complex conditions.展开更多
A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electro...A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electrons in a metal are resonated with photons.The structural parameters are fine-tuned and the sensing performance of the sensor is studied.The results show that the maximum spectral sensitivity reaches 18 000 nm/RIU in the refractive index range of 1.24—1.32,and the maximum resolution is 5.56×10^(-6) RIU.The novel structure with high sensitivity and low refractive index provides a new perspective for fluid density detection.展开更多
Electronic skin has showcased superior sensing capabilities inspired from human skin.However,most preceding studies focused on the dermis of the skin rather than the epidermis.In particular,the pseudo-porous structura...Electronic skin has showcased superior sensing capabilities inspired from human skin.However,most preceding studies focused on the dermis of the skin rather than the epidermis.In particular,the pseudo-porous structural domain of the epidermis increases the skin's tolerance while ensuring its susceptibility to touch.Yet,most endeavors on the porous structures failed to replicate the superior sensing performance of skin-like counterparts in terms of sensitivity and/or detection range.Stimulated by the strategy that the epidermis of the skin absorbs energy while producing ionic conduction to the nerves,this work initiatively introduced an easy-to-produce,and low-cost pressure sensor based on ionic-gel foam,and achieved a high sensitivity(2893 kPa^(-1))within a wide pressure range(up to~1 MPa),which ranked among the best cases thus far.Moreover,the factors affecting the sensor performance were explored while the sensing principles were enriched.Inspiringly,the plantar pressure measurement by harnessing the as-prepared sensor unveiled an ultra-broad detection range(100 Pa-1 MPa),thus delivering a huge application potential in the field of robot and health monitoring.展开更多
High-temperature thin-film strain sensors are advanced technological devices for monitoring stress and strain in extreme environments,but the coupling of temperature and strain at high temperature is a challenge for t...High-temperature thin-film strain sensors are advanced technological devices for monitoring stress and strain in extreme environments,but the coupling of temperature and strain at high temperature is a challenge for their use.Here,this issue is addressed by creating a composite ink that combines Pb_(2)Ru_(2)O_(6) and TiB_(2) using polysilazane(PSZ)as a binder.After direct writing and annealing the PSZ/Pb_(2)Ru_(2)O_(6)/TiB_(2) film at 800℃ in air,the resulting thin film exhibits a low temperature coefficient of resistance(TCR)of only 281 ppm/℃ over a wide temperature range from 100℃ to 700℃,while also demonstrating high sensitivity with a gauge factor approaching 19.8.This exceptional performance is attributed to the intrinsic properties of Pb_(2)Ru_(2)O_(6),which has positive TCR at high temperature,and TiB2,which has negative TCR at high temperature.Combining these materials reduces the overall TCR of the film.Tests showed that the PSZ/Pb_(2)Ru_(2)O_(6)/TiB_(2) film maintains stable strain responses and significant signal output even under varying temperature.These findings provide valuable insights for developing high-temperature strain sensors with low TCR and high sensitivity,highlighting their potential for applications in high-temperature strain measurements.展开更多
Flexible piezoresistive sensors based on biomimetic microstructures are prospective for broad application in motion monitoring.However,the design and preparation processes of most biomimetic microstructures in the exi...Flexible piezoresistive sensors based on biomimetic microstructures are prospective for broad application in motion monitoring.However,the design and preparation processes of most biomimetic microstructures in the existing studies are complicated,and there are few studies on pore size control.Herein,the porous structure of human bones was used as a biomimetic prototype,and optimally designed by creating a theoretical equivalent sensor model and a finite element model.Soluble raw materials such as sugar and salt in different particle sizes were pressed into porous templates.Based on the template method,porous structures in different pore sizes were prepared using polydimethylsiloxane(PDMS)polymer as the substrate.On this basis,graphene oxide conductive coating was prepared with the modified Hummers method and then deposited via dip coating onto the substrate.Finally,a PDMS-based porous structure biomimetic flexible piezoresistive sensor was developed.Mechanically,the deformation of the sensor under the same load increased with the pore size rising from 0.3 to 1.5 mm.Electrically,the resistance rang of the sensor was enlarged as the pore size rose.The resistance variation rates of samples with pore sizes of 0.3,1.0,and 1.5 mm at approximately the 200th cycle were 63%,79%,and 81%,respectively;at the 500th cycle,these values were 63%,77%,and 79%;and at the 1000th cycle,they stabilized at 63%,74%,and 76%.These results indicate that the fabricated sensor exhibits high stability and fatigue resistance.At the pressure of 0–25 kPa,the sensitivity rose from 0.0688 to 0.1260 kPa−1,and the performance was enhanced by 83%.After 1,000 cycles of compression testing,the signal output was stable,and no damage was caused to the substrate.Further application tests showed the biomimetic sensor accurately and effectively identified human joint motions and gestures,and has potential application value in human motion monitoring.展开更多
High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneous...High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneously achieve high sensitivity,a wide detection range,and good mechanical stability remains a challenge.In this paper,we propose a flexible piezoresistive pressure sensor based on a Ti_(3)C_(2)Tx(MXene)/polyethylene oxide(PEO)composite nanofiber membrane(CNM).The sensor,utilizing MXene(0.4 wt%)/PEO(5 wt%),exhibits high sensitivity(44.34 kPa^(−1)at 0−50 kPa,12.99 kPa^(−1)at 50−500 kPa)and can reliably monitor physiological signals and other subtle cues.Moreover,the sensor features a wide detection range(0−500 kPa),fast response and recovery time(~150/45 ms),and excellent mechanical stability(over 10000 pressure cycles at maximum load).Through an MXene/PEO sensor array,we demonstrate its applications in human physiological signal monitoring,providing a reliable way to expand the application of MXene-based flexible pressure sensors.展开更多
This paper reports sensitive high resolution ion micro-probe U-Pb zircon ages for the "Huoqiu Group" and granitoids of the Early Precambrian basement in the Huoqiu area, southeastern margin of the North China Craton...This paper reports sensitive high resolution ion micro-probe U-Pb zircon ages for the "Huoqiu Group" and granitoids of the Early Precambrian basement in the Huoqiu area, southeastern margin of the North China Craton. The "Huoqiu Group" is similar in rock association and metamorphism to the khondalite series, apart from it containing considerable amounts of banded iron formation. All detrital zircons from the "Huoqiu Group" meta-sedimentary rocks are 3.0 Ga and 2.75 Ga, without any 2.5 Ga and younger ones, as is commonly found in Paleoproterozoic khondalite series in other areas of the North China Craton. In the Huoqiu area, 2.75 Ga and 2.56 Ga granitoids have also been identified. This basement assemblage underwent strong metamorphism during the late Paleoproterozoic (-1.84 Ga) tectonothermal event that is widely developed in the North China Craton. Thus the formation time of the "Huoqiu Group" can be constrained between 2.75 and 1.84 Ga in terms of detrital and metamorphic zircon ages. It is considered, combined with regional data, that there may be a Paleoproterozoic collision orogen extending in a NWW-SEE direction to the southern margin of the North China Craton.展开更多
Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developin...Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developing luminescent thermometers due to their remarkable structural diversities and tunable luminescence properties. Here, we synthesized a series of luminescent mixed-lanthanide MOFs,EuTbBPT(x = 0.019, 0.058, 0.106; H3 BPT = biphenyl-3,4’,5-tricarboxylate acid) and adopted powder X-ray diffraction(PXRD), thermogravimetric analysis(TGA) and Fourier transform infrared(FT-IR) to characterize the resulting products. The temperature-dependent photoluminescence emission spectra were recorded to investigate their potential applications in physiological temperature readout. It is found that the intensity ratio of Tbto Euis linearly correlated with temperature and the relative sensitivity is higher than 1.5%/℃ over the entire physiological temperature range. Furthermore,the temperaturedependent luminescence color emission allows for visual colorimetric temperature measurements.Luminescence lifetime testing and triplet energy level measurement were further conducted to study the mechanism.展开更多
Highly sensitive pressure sensors are often deployed in human-machine interaction area,touch screen and human motion detection.However,there are still great challenges to fabricating with high sensitivity pressure sen...Highly sensitive pressure sensors are often deployed in human-machine interaction area,touch screen and human motion detection.However,there are still great challenges to fabricating with high sensitivity pressure sensor with wide-range detection.Herein,we developed a new strategy to fabricate a highly sensitive pressure sensor using sandpaper and improve its detection range using a sacrificial template.It was the fthatirst time to combine microstructure processing with the sacrificial template method to fabricate pressure sensor.The microstructure of sandpaper endowed the sensor with high sensitivity,and the elastic substrate enhanced the sensor ability to resist high pressure without being damaged.The fabricated sensor device exhibits a superior sensitivity of 39.077 kPa-1in the range from 50 kPa to 110 kPa with a broad linear response.Remarkably,high pressure ceiling(<160 kPa) ensures that the sponge could be applied in different practical conditions to monitor a range of subtle human motions including finger,wrist bending,and pulse.For applications,the sensor device can not only detect the foot stepping behavior(0.7 MPa) but also produce an obvious response to an extremely slight paper(9 mg,~0.9 Pa).The successful preparation of this micro-structured elastic sponge material provided new ideas for exploring its potential applications in pressure sensors and flexible wearable electronic devices.展开更多
We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the se...We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the sensitivity of the sensor can be orders of magnitude higher than that of aconventional sensor, and high quality factor is not critical in it. Moreover, by optimizing the length of the feedback waveguide to be equal to the perimeter of the ring, the measurement range of the proposed sensor is twice as much as that of the conventional sensor in the weak coupling case.展开更多
The World Health Organization has declared COVID-19 a pandemic.The demand for devices or systems to diagnose and track COVID-19 infections noninvasively not only in hospitals but also in home settings has led to incre...The World Health Organization has declared COVID-19 a pandemic.The demand for devices or systems to diagnose and track COVID-19 infections noninvasively not only in hospitals but also in home settings has led to increased interest in consumer-grade wearables.A common symptom of COVID-19 is dyspnea,which may manifest as an increase in respiratory and heart rates.In this paper,a novel piezoelectric strain sensor is presented for real-time monitoring of respiratory and heartbeat signals.A highly sensitive and stretchable piezoelectric strain sensor is fabricated using a piezoelectric film with a serpentine layout.The thickness of the patterned PVDF flexible piezoelectric strain sensor is only 168μm,and the voltage sensitivity reaches 0.97 mV/με.The effective modulus is 13.5 MPa,which allows the device to fit to the skin and detect the small strain exhibited by the human body.Chest vibrations are captured by the piezoelectric sensor,which produces an electrical output voltage signal conformally mapped with respiratory–cardiac activities.The separate heart activity and respiratory signals are extracted from the mixed respiratory–cardiac signal by an empirical mode decomposition data processing algorithm.By detecting vital signals such as respiratory and heart rates,the proposed device can aid early diagnosis and monitoring of respiratory diseases such as COVID-19.展开更多
The flourishing development in flexible electronics has provoked intensive research in flexible strain sensors to realize accurate perception acquisition under different external stimuli.However,building hydrogel-base...The flourishing development in flexible electronics has provoked intensive research in flexible strain sensors to realize accurate perception acquisition under different external stimuli.However,building hydrogel-based strain sensors with high stretchability and sensitivity remains a great challenge.Herein,MXene nanosheets were composited into polyacrylamide-sodium alginate matrix to construct mechanical robust and sensitive double networked hydrogel strain sensor.The hydrophilic MXene nanosheets formed strong interactions with the polymer matrix and endowed the hydrogel with excellent tensile properties(3150%),compliant mechanical strength(2.03 kPa^(-1)in Young’s Module)and long-lasting stability and fatigue resistance(1000 dynamic cycles under 1,600%strain).Due to the highly oriented MXene-based three dimensional conductive networks,the hydrogel sensor achieved extremely high tensile sensitivity(18.15 in gauge factor)and compression sensitivity(0.38 kPa^(-1)below 3 kPa).MXene hydrogel-based strain sensors also displayed negligible hysteresis in electromechanical performance,typical frequent-independent feature and rapid response time to external stimuli.Moreover,the sensor exhibited accurate response to different scales of human movements,providing potential application in speech recognition,expression recognition and handwriting verification.展开更多
Herein,we report a new metal-organic framework with an AIE ligand (H_(4)TCPP=2,3,5,6-tetra-(4-carboxyphenyl)pyrazine) and Mg^(2+) ions,that is,[Mg_(2)(H_(2)O)_(4)TCPP]·DMF·5CH_(3)CN (Mg-TCPP,TCPP=tetra-(4-ca...Herein,we report a new metal-organic framework with an AIE ligand (H_(4)TCPP=2,3,5,6-tetra-(4-carboxyphenyl)pyrazine) and Mg^(2+) ions,that is,[Mg_(2)(H_(2)O)_(4)TCPP]·DMF·5CH_(3)CN (Mg-TCPP,TCPP=tetra-(4-carboxyphenyl)pyrazine) for detection of nitroaromatic explosives.Due to the coordination effect and restricted intramolecular rotation,Mg-TCPP exhibits bright blue light.As a fluorescent sensor,Mg-TCPP exhibits high selectivity and sensitivity for sensing 2,4,6-trinitrophenol (TNP) by quenching behaviors with the Stern-Volmer quenching constant (K_(SV)) of 3.63×10^(5)L/mol and achieves the low limit of detection of 25.6 ppb,which is beyond most of the previously reported fluorescent materials.Notably,the portable Mg-TCPP films are prepared and it can be used for rapid and sensitive TNP detection in a variety of environments including organic solvent and aqueous solution.Moreover,TNP vapor can be detected within 3 min by naked eye and the film could be regenerated under simple solvent cleaning.展开更多
文摘Objective Cardiovascular complications contribute to postoperative morbidity and mortality in elderly hip fracture patients. Limited data are available regarding which preoperative risk factors predict cardiovascular course following hip fracture surgery (HFS). We used high sensitive troponin I (hs-TnI) assays and clinical parameters to identify preoperative risk factors associated with major adverse cardiac events (MACE) in elderly hip frac^u'e patients. Method From August 2014 to November 2016, 575 patients with hip fracture were enrolled in a retrospective, single-center registry. A total of 262 of these patients underwent HFS and hs-TnI assays. MACE was defined as postoperative all-cause deaths, heart failure (HF), new-onset atrial fibrillation (AF), myocardial infarction (MI) and cardiovascular re-hospitalization that occurred within 90 days postoperative. Results Of 262 HFS patients, MACE developed following HFS in 65 (24.8%). Patients with MACE were older and had higher rates of renal insufficiency, coronary artery disease, prior HF, low left ventricular ejection fraction and use of beta blockers; higher levels of hs-Tnl and N-terminal pro-brain natriuretic peptide (NT-proBNP) and higher revised cardiac risk index. A preoperative hs-TnI≥ 6.5 ng/L was associated with high risk of postoperative HF, new-onset AF and MACE. In multivariable analysis, pre-operative independent predictors for MACE were age 〉 80 years [adjusted hazard ratio (HR): 1.79, 95% confident interval (CI): 1.03-3.13, P = 0.04], left ventricular ejection fraction (LVEF) 〈 50% (adjusted HR: 3.17, 95% CI: 1.47-5.82, P 〈 0.01) and hs-TnI 〉 6.5 ng/L (adjusted HR: 3.75, 95% CI: 2.09~5.17, P 〈 0.01). Conclusion In elderly patients with hip fracture who undergo HFS, a preoperative assessment of hs-TnI may help the risk refinement of cardiovascular complications.
基金Project (No.QN2008-001) supported by the Beijing Municipal Health Bureau Young Persons’Foundation,China
文摘Objective:Percutaneous coronary intervention(PCI) triggers an acute inflammatory response,while sirolimus is known to have anti-inflammatory properties;the inflammatory system response to PCI after sirolimus-eluting stent placement remains unclear.The purpose of this study is to determine the changes in high sensitive C-reactive protein(hs-CRP) and apelin after PCI procedure and drug-eluting stent implantation in patients with and without reduced left ventricular systolic function.Methods:Forty-eight consecutive patients undergoing PCI at the Beijing Anzhen Hospital between July and September 2006 were recruited.Sirolimus-eluting stents were employed in all patients.Blood samples were drawn immediately before and 24 h after the procedure.Plasma hs-CRP and apelin levels were determined by enzyme immunoassay.Results:Paired t-test revealed a significant increase in both hs-CRP and apelin post-procedure(P=0.006 and P<0.0001,respectively).Patients with reduced left ventricular ejection fraction(LVEF) had significantly lower baseline apelin levels compared to those with normal ventricular function [(46.8±10.8) vs.(72.0±8.4) pg/ml,P<0.001].However,apelin increased to a level similar to the level of those with normal left ventricular systolic function 24 h after the PCI procedure [(86.7±11.6) vs.(85.1±6.1) pg/ml,P=0.72].Conclusions:hs-CRP and apelin levels increased after PCI and sirolimus-eluting stent implantation.Patients with impaired left ventricular systolic function had significantly lower baseline apelin levels,which increased significantly after PCI.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY13H180007)
文摘This study was undertaken to investigate the correlation of the enhancement degree on contrast-enhanced ultrasound(CEUS) with the histopathology of carotid plaques and the serum high sensitive C-reactive protein(hs-CRP) levels in patients undergoing carotid endarterectomy(CEA). Carotid CEUS was performed preoperatively in 115 patients who would undergo CEA, and the enhancement degree of the carotid plaques was evaluated by both the visual semiquantitative analysis and the quantitative time-intensity curve analysis. Serum hs-CRP levels were detected using the particle-enhanced immunoturbidimetric assay also before the operation. Additionally, the carotid plaque samples were subjected to histopathological examination postoperatively. The density of neovessels and the number of macrophages in the plaques were assessed by immunohistochemistry. The results showed that among the 115 patients, grade 0 plaque contrast enhancement was noted in 35 patients, grade 1 in 48 patients and grade 2 in 32 patients. The degree of plaque enhancement, the density of neovessels, the number of macrophages, and the hs-CRP levels were highest in the grade 2 patients. Correlation analysis showed that the enhancement degree of the carotid plaques was closely related to the immunohistochemical parameters of the plaques and the serum hs-CRP levels. It was suggested that the carotid plaque enhancement on CEUS can be used to evaluate the vulnerability of carotid plaques.
文摘Objective To evaluate the effects of simvastatin combined with omega-3 fatty acids on high sensitive C-reactive protein(HsCRP), lipidemia, and fibrinolysis in coronary heart disease (CHD) and CHD risk equivalent patients with mixed dyslipi-demia. Methods A randomized, double-blind placebo controlled and parallel group trial was conducted. Patients with CHD and CHD risk equivalents with mixed dyslipidemia were treated with 10 or 20 mg simvastatin for 6-12 weeks. Following with the treatment of patients whose low-density lipoprotein cholesterol (LDL-ch) reaching goal level (< 100 mg/dL) or close to the goal (< 130 mg/dL), while triglyceride (TG) ≥200 mg/dL and < 500 mg/dL, was combined with omega-3 fatty acids (3 g/d) or a placebo for 2 months. The effects of the treatment on HsCRP, total cholesterol (TC), LDL-ch, high-density lipoprotein cholesterol (HDL-ch), TG, lipoprotein (a) [LP (a)], apolipoprotein A1 (apoA1), apolipoprotein B (apoB), plasminogen activator inhibitor-1 (PAI-1), and tissue plasminogen activator (tPA) were investigated. Forty patients finished the study with each group consisting of twenty patients. Results (1) There were significant reductions of HsCRP, TG, TC, and TC/HDL-ch, which decreased by 2.16 ±2.77 mg/L (38.5%), 94.0 ±65.4 mg/dL (31.1%), 13.3 ±22.3 mg/dL (6.3%), 0.78 ±1.60 respectively in the omega-3 fatty acids group (P< 0.01, < 0.001, < 0.05, < 0.05) compared to the baseline. HsCRP and triglyceride reduction were more significant in omega-3 fatty acids group compared to the placebo group (P=0.021 and 0.011 respectively). (2) In the omega-3 fatty acids group, the values and percentage of TG reduction had a significantly positive relation with HsCRP reduction (r=0.51 and 0.45, P=0.021 and 0.047 respectively). Conclusion In CHD and CHD risk equivalent patients with mixed dyslipidemia, dyslipidemia’s therapeutic effect using simvastatin and omega-3 fatty acids may result from not only the combination of lipid adjustment, but also enhancement of their own nonlipid influences.
基金financially supported by the National Natural Science Foundation of China(No.11604227)International Visiting Program for Excellent Young Scholars of SCU(No.20181504)International Science and Technology Innovation Cooperation of Sichuan Province(No.21GJHZ0230)。
文摘Chiral metamaterials have been a topic of significant research interest in recent years due to their potential for various applications in nanophotonic devices and chiral biosensors.However,the intrinsic Ohmic loss in surface plasmonic resonance has limited their practical use,resulting in large light dissipation and weak chiroptical resonance.Here,we report on the development of high-performance dielectric chiral shells(DCS)through a two-step Si deposition process on a self-assembled microsphere monolayer.The form DCS sample completely oyercomes the cancelation effect originated from the disorder property of the micro-sphere monolayer in macroscale,and at a wavelength of approximately 710 nm,the measured optimal chiral signal(g-factor)and transmittance can reach up to 0.7 and 0.3,respectively.The strong chiroptical effect comes from the asymmetric circular displacement currents(i.e.,magnetic modes)enabled by the specific shell geometry.The chiral shell geometry,electromagnetic properties,sensor sensitivity of chiral molecules and figure of merit are systematically investigated.The DCSs demonstrate highly sensitive detection of chiral biomolecules owing to their easily accessible geometry and enhanced uniform chiral field.
基金the National Natural Science Foundation of China(No.22075071)Harbin Manufacturing Science and Technology Innovation Talent Project(No.2022CXRCCG016)+1 种基金Outstanding Youth Science Foundation of Heilongjiang University(No.JCL202002)Special Project of Joint Dairy College in East University of Heilongjiang-National Dairy Engineering and Technology Research Center(No.LHXYDS202001).
文摘To achieve a lower detection limit has always been a goal of analytical chemists.Herein,we demonstrate the first picomolar level detection capability for Fe3+ion via luminescence detection technology.The results of structural analysis and theoretical calculation show that Fe3+ions are adsorbed on the central node of Eu-DBM(DBM=dibenzoylmethane)sensor in the form of single ion at ultralow concentration.Subsequently,the pathways of photo-induced charge and energy transfer of the obtained Eu-DBM@Fe^(3+)material have been changed,from the initial DBM-to-Eu^(3+)before Fe^(3+)adsorption to the ultimate DBM-to-Fe^(3+)after adsorption process,which quenches the luminescence of Eu3+ion.This work not only obtains the highly sensitive luminescence detection ability,but also innovatively proposes the single-ion adsorption mechanism,both of which have important scientific and application values for the development of more efficient detection agents in the future.
基金supported by the Youth Project of the National Natural Science Foundation of China(Grant No.52105594)the Youth Project of the Applied Basic Research Program of Shanxi Province(Grant No.20210302124274)+4 种基金the Key Research and Development Program of Shanxi Province(Grant No.202102030201005)the Natural Youth Science Foundation of Shanxi Province(Grant Nos.202103021223005 and 202203021212015)the Fund for Shanxi 1331 Project,the Science and Technology Innovation Plan for Colleges and Universities in Shanxi Province(Grant No.2022L575)the Science and Technology Innovation Project in Higher Schools in Shanxi(Grant No.J2020383)Teaching Reform and Innovation Project of the Education Department of Shanxi Province(Grant No.J20221195).
文摘Flexible pressure sensors show great promise for applications in such fields as electronic skin,healthcare,and intelligent robotics.Traditional capacitive pressure sensors,however,face the problem of low sensitivity,which limits their wider application.In this paper,a flexible capacitive pressure sensor with microstructured ionization layer is fabricated by a sandwich-type process,with a low-cost and simple process of inverted molding with sandpapers being used to form a thermoplastic polyurethane elastomer ionic film with double-sided microstructure as the dielectric layer of the sensor,with silver nanowires as electrodes.The operating mechanism of this iontronic pressure sensor is analyzed using a graphical method,and the sensor is tested on a pressure platform.The test results show that the sensor has ultrahigh pressure sensitivities of 3.744 and 1.689 kPa^(−1) at low(0-20 kPa)and high(20-800 kPa)pressures,respectively,as well as a rapid response time(100 ms),and it exhibits good stability and repeatability.The sensor can be used for sensitive monitoring of activities such as finger bending,and for facial expression(smile,frown)recognition,as well as speech recognition.
文摘High-sensitivity sensors represent a critical frontier in modern sensing technology,driving innovations across fields such as biomedical monitoring,precision instrumentation,environmental detection,and indus-trial automation.As demands for accuracy,miniaturization,and reliability continue to grow,developing novel sensor architectures and functional materials has become essential to achieving enhanced performance under extreme or complex conditions.
基金supported by the Natural Science Foundation of Tianjin City (No.19JCYBJC17000)the National Natural Science Foundation of China (No.11905159)。
文摘A D-type photonic crystal fiber(PCF) sensor based on surface plasmon resonance(SPR) principle is designed.In order to excite the SPR effect,a gold film is plated on the open-loop channel of the sensor,the free electrons in a metal are resonated with photons.The structural parameters are fine-tuned and the sensing performance of the sensor is studied.The results show that the maximum spectral sensitivity reaches 18 000 nm/RIU in the refractive index range of 1.24—1.32,and the maximum resolution is 5.56×10^(-6) RIU.The novel structure with high sensitivity and low refractive index provides a new perspective for fluid density detection.
基金supported the Chongqing Natural Science Foundation(CSTB2023NSCQ-MSX0459&CSTB2023NSCQ-MSX0231)the Graduate Research and Innovation Foundation of Chongqing,China(CYB23048)+1 种基金the Fundamental Research Program under Grant(JCKY2022603C017)National Natural Science Foundation of China(NSFC 52175281).
文摘Electronic skin has showcased superior sensing capabilities inspired from human skin.However,most preceding studies focused on the dermis of the skin rather than the epidermis.In particular,the pseudo-porous structural domain of the epidermis increases the skin's tolerance while ensuring its susceptibility to touch.Yet,most endeavors on the porous structures failed to replicate the superior sensing performance of skin-like counterparts in terms of sensitivity and/or detection range.Stimulated by the strategy that the epidermis of the skin absorbs energy while producing ionic conduction to the nerves,this work initiatively introduced an easy-to-produce,and low-cost pressure sensor based on ionic-gel foam,and achieved a high sensitivity(2893 kPa^(-1))within a wide pressure range(up to~1 MPa),which ranked among the best cases thus far.Moreover,the factors affecting the sensor performance were explored while the sensing principles were enriched.Inspiringly,the plantar pressure measurement by harnessing the as-prepared sensor unveiled an ultra-broad detection range(100 Pa-1 MPa),thus delivering a huge application potential in the field of robot and health monitoring.
基金the National Key Research and Development Program of China(Grant No.2021YFB2012100)the Major Science and Technology Projects in Fujian Province(Grant No.2023HZ021005)+1 种基金the Open Project Program of Fujian Key Laboratory of Special Intelligent Equipment Measurement and Control(Grant No.FJIES2023KF06)the Industry-University-Research Co-operation Fund of the Eighth Research Institute of China Aerospace Science and Technology Corporation(Grant No.SAST2023-061).
文摘High-temperature thin-film strain sensors are advanced technological devices for monitoring stress and strain in extreme environments,but the coupling of temperature and strain at high temperature is a challenge for their use.Here,this issue is addressed by creating a composite ink that combines Pb_(2)Ru_(2)O_(6) and TiB_(2) using polysilazane(PSZ)as a binder.After direct writing and annealing the PSZ/Pb_(2)Ru_(2)O_(6)/TiB_(2) film at 800℃ in air,the resulting thin film exhibits a low temperature coefficient of resistance(TCR)of only 281 ppm/℃ over a wide temperature range from 100℃ to 700℃,while also demonstrating high sensitivity with a gauge factor approaching 19.8.This exceptional performance is attributed to the intrinsic properties of Pb_(2)Ru_(2)O_(6),which has positive TCR at high temperature,and TiB2,which has negative TCR at high temperature.Combining these materials reduces the overall TCR of the film.Tests showed that the PSZ/Pb_(2)Ru_(2)O_(6)/TiB_(2) film maintains stable strain responses and significant signal output even under varying temperature.These findings provide valuable insights for developing high-temperature strain sensors with low TCR and high sensitivity,highlighting their potential for applications in high-temperature strain measurements.
基金supported by the National Natural Science Foundation of China(52175270)the Project of Scientifc and Technological Development Plan of Jilin Province(20220508130RC)+3 种基金the Science and Technology Development Program of Jilin Province(YDZJ202501ZYTS370)the Scientific Research Project of Education Department of Jilin Province(JJKH20251196KJ)the Scientific Research Project of Education Department of Jilin Province(JJKH20251195KJ)the Key Project of State Key Laboratory of Changchun City(23GZZ14).
文摘Flexible piezoresistive sensors based on biomimetic microstructures are prospective for broad application in motion monitoring.However,the design and preparation processes of most biomimetic microstructures in the existing studies are complicated,and there are few studies on pore size control.Herein,the porous structure of human bones was used as a biomimetic prototype,and optimally designed by creating a theoretical equivalent sensor model and a finite element model.Soluble raw materials such as sugar and salt in different particle sizes were pressed into porous templates.Based on the template method,porous structures in different pore sizes were prepared using polydimethylsiloxane(PDMS)polymer as the substrate.On this basis,graphene oxide conductive coating was prepared with the modified Hummers method and then deposited via dip coating onto the substrate.Finally,a PDMS-based porous structure biomimetic flexible piezoresistive sensor was developed.Mechanically,the deformation of the sensor under the same load increased with the pore size rising from 0.3 to 1.5 mm.Electrically,the resistance rang of the sensor was enlarged as the pore size rose.The resistance variation rates of samples with pore sizes of 0.3,1.0,and 1.5 mm at approximately the 200th cycle were 63%,79%,and 81%,respectively;at the 500th cycle,these values were 63%,77%,and 79%;and at the 1000th cycle,they stabilized at 63%,74%,and 76%.These results indicate that the fabricated sensor exhibits high stability and fatigue resistance.At the pressure of 0–25 kPa,the sensitivity rose from 0.0688 to 0.1260 kPa−1,and the performance was enhanced by 83%.After 1,000 cycles of compression testing,the signal output was stable,and no damage was caused to the substrate.Further application tests showed the biomimetic sensor accurately and effectively identified human joint motions and gestures,and has potential application value in human motion monitoring.
基金support from Beijing Natural Science Foundation−Xiaomi Innovation Joint Fund(Grant No.L233009)the National Natural Science Foundation of China(NSFC Grant Nos.62422409,62174152 and 62374159)from the Youth Innovation Promotion Association of Chinese Academy of Sciences(Grant No.2020115).
文摘High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneously achieve high sensitivity,a wide detection range,and good mechanical stability remains a challenge.In this paper,we propose a flexible piezoresistive pressure sensor based on a Ti_(3)C_(2)Tx(MXene)/polyethylene oxide(PEO)composite nanofiber membrane(CNM).The sensor,utilizing MXene(0.4 wt%)/PEO(5 wt%),exhibits high sensitivity(44.34 kPa^(−1)at 0−50 kPa,12.99 kPa^(−1)at 50−500 kPa)and can reliably monitor physiological signals and other subtle cues.Moreover,the sensor features a wide detection range(0−500 kPa),fast response and recovery time(~150/45 ms),and excellent mechanical stability(over 10000 pressure cycles at maximum load).Through an MXene/PEO sensor array,we demonstrate its applications in human physiological signal monitoring,providing a reliable way to expand the application of MXene-based flexible pressure sensors.
基金supported by the Ministry of Land and Resources of the Peoples’ Republic of China (1212010711815, 1212010811033) and the Beijing SHRIMP Center
文摘This paper reports sensitive high resolution ion micro-probe U-Pb zircon ages for the "Huoqiu Group" and granitoids of the Early Precambrian basement in the Huoqiu area, southeastern margin of the North China Craton. The "Huoqiu Group" is similar in rock association and metamorphism to the khondalite series, apart from it containing considerable amounts of banded iron formation. All detrital zircons from the "Huoqiu Group" meta-sedimentary rocks are 3.0 Ga and 2.75 Ga, without any 2.5 Ga and younger ones, as is commonly found in Paleoproterozoic khondalite series in other areas of the North China Craton. In the Huoqiu area, 2.75 Ga and 2.56 Ga granitoids have also been identified. This basement assemblage underwent strong metamorphism during the late Paleoproterozoic (-1.84 Ga) tectonothermal event that is widely developed in the North China Craton. Thus the formation time of the "Huoqiu Group" can be constrained between 2.75 and 1.84 Ga in terms of detrital and metamorphic zircon ages. It is considered, combined with regional data, that there may be a Paleoproterozoic collision orogen extending in a NWW-SEE direction to the southern margin of the North China Craton.
基金supported by the National Natural Science Foundation of China(51432001,51472217,51632008,U1609219)
文摘Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developing luminescent thermometers due to their remarkable structural diversities and tunable luminescence properties. Here, we synthesized a series of luminescent mixed-lanthanide MOFs,EuTbBPT(x = 0.019, 0.058, 0.106; H3 BPT = biphenyl-3,4’,5-tricarboxylate acid) and adopted powder X-ray diffraction(PXRD), thermogravimetric analysis(TGA) and Fourier transform infrared(FT-IR) to characterize the resulting products. The temperature-dependent photoluminescence emission spectra were recorded to investigate their potential applications in physiological temperature readout. It is found that the intensity ratio of Tbto Euis linearly correlated with temperature and the relative sensitivity is higher than 1.5%/℃ over the entire physiological temperature range. Furthermore,the temperaturedependent luminescence color emission allows for visual colorimetric temperature measurements.Luminescence lifetime testing and triplet energy level measurement were further conducted to study the mechanism.
基金financially supported by the National Natural Science Foundation of China (Nos.22075046,51972063,2150112751502185)+2 种基金Natural Science Funds for Distinguished Young Scholar of Fujian Province (No.2020J06038)Natural Science Foundation of Fujian Province (Nos.2020J01514,2019J01652,and2019J01256)111 Project (No.D17005)。
文摘Highly sensitive pressure sensors are often deployed in human-machine interaction area,touch screen and human motion detection.However,there are still great challenges to fabricating with high sensitivity pressure sensor with wide-range detection.Herein,we developed a new strategy to fabricate a highly sensitive pressure sensor using sandpaper and improve its detection range using a sacrificial template.It was the fthatirst time to combine microstructure processing with the sacrificial template method to fabricate pressure sensor.The microstructure of sandpaper endowed the sensor with high sensitivity,and the elastic substrate enhanced the sensor ability to resist high pressure without being damaged.The fabricated sensor device exhibits a superior sensitivity of 39.077 kPa-1in the range from 50 kPa to 110 kPa with a broad linear response.Remarkably,high pressure ceiling(<160 kPa) ensures that the sponge could be applied in different practical conditions to monitor a range of subtle human motions including finger,wrist bending,and pulse.For applications,the sensor device can not only detect the foot stepping behavior(0.7 MPa) but also produce an obvious response to an extremely slight paper(9 mg,~0.9 Pa).The successful preparation of this micro-structured elastic sponge material provided new ideas for exploring its potential applications in pressure sensors and flexible wearable electronic devices.
基金Project supported by the National Basic Research Program of China(Grant No.2010CB327601)
文摘We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the sensitivity of the sensor can be orders of magnitude higher than that of aconventional sensor, and high quality factor is not critical in it. Moreover, by optimizing the length of the feedback waveguide to be equal to the perimeter of the ring, the measurement range of the proposed sensor is twice as much as that of the conventional sensor in the weak coupling case.
基金We are grateful for funding from the Natural Science Foundation of China(NSFC Grant No.62001322)the Tianjin Municipal Science and Technology Project(No.20JCQNJC011200)+1 种基金the National Key Research and Development Program(No.2020YFB2008801)the Nanchang Institute for Microtechnology of Tianjin University.
文摘The World Health Organization has declared COVID-19 a pandemic.The demand for devices or systems to diagnose and track COVID-19 infections noninvasively not only in hospitals but also in home settings has led to increased interest in consumer-grade wearables.A common symptom of COVID-19 is dyspnea,which may manifest as an increase in respiratory and heart rates.In this paper,a novel piezoelectric strain sensor is presented for real-time monitoring of respiratory and heartbeat signals.A highly sensitive and stretchable piezoelectric strain sensor is fabricated using a piezoelectric film with a serpentine layout.The thickness of the patterned PVDF flexible piezoelectric strain sensor is only 168μm,and the voltage sensitivity reaches 0.97 mV/με.The effective modulus is 13.5 MPa,which allows the device to fit to the skin and detect the small strain exhibited by the human body.Chest vibrations are captured by the piezoelectric sensor,which produces an electrical output voltage signal conformally mapped with respiratory–cardiac activities.The separate heart activity and respiratory signals are extracted from the mixed respiratory–cardiac signal by an empirical mode decomposition data processing algorithm.By detecting vital signals such as respiratory and heart rates,the proposed device can aid early diagnosis and monitoring of respiratory diseases such as COVID-19.
基金supported by the National Natural Science Foundation of China(No.61775095)six talent peak innovation team in Jiangsu Province(No.TD-SWYY-009)“Taishan scholars”construction special fund of Shandong Province。
文摘The flourishing development in flexible electronics has provoked intensive research in flexible strain sensors to realize accurate perception acquisition under different external stimuli.However,building hydrogel-based strain sensors with high stretchability and sensitivity remains a great challenge.Herein,MXene nanosheets were composited into polyacrylamide-sodium alginate matrix to construct mechanical robust and sensitive double networked hydrogel strain sensor.The hydrophilic MXene nanosheets formed strong interactions with the polymer matrix and endowed the hydrogel with excellent tensile properties(3150%),compliant mechanical strength(2.03 kPa^(-1)in Young’s Module)and long-lasting stability and fatigue resistance(1000 dynamic cycles under 1,600%strain).Due to the highly oriented MXene-based three dimensional conductive networks,the hydrogel sensor achieved extremely high tensile sensitivity(18.15 in gauge factor)and compression sensitivity(0.38 kPa^(-1)below 3 kPa).MXene hydrogel-based strain sensors also displayed negligible hysteresis in electromechanical performance,typical frequent-independent feature and rapid response time to external stimuli.Moreover,the sensor exhibited accurate response to different scales of human movements,providing potential application in speech recognition,expression recognition and handwriting verification.
基金supported by the National Natural Science Foundation of China(No.22175033)Science and Technology Development Plan of Jilin Province(Nos.YDZJ202101ZYTS063,20210508022RQ)Research Foundation of Education Department of Shaanxi Province(No.18JS009)。
文摘Herein,we report a new metal-organic framework with an AIE ligand (H_(4)TCPP=2,3,5,6-tetra-(4-carboxyphenyl)pyrazine) and Mg^(2+) ions,that is,[Mg_(2)(H_(2)O)_(4)TCPP]·DMF·5CH_(3)CN (Mg-TCPP,TCPP=tetra-(4-carboxyphenyl)pyrazine) for detection of nitroaromatic explosives.Due to the coordination effect and restricted intramolecular rotation,Mg-TCPP exhibits bright blue light.As a fluorescent sensor,Mg-TCPP exhibits high selectivity and sensitivity for sensing 2,4,6-trinitrophenol (TNP) by quenching behaviors with the Stern-Volmer quenching constant (K_(SV)) of 3.63×10^(5)L/mol and achieves the low limit of detection of 25.6 ppb,which is beyond most of the previously reported fluorescent materials.Notably,the portable Mg-TCPP films are prepared and it can be used for rapid and sensitive TNP detection in a variety of environments including organic solvent and aqueous solution.Moreover,TNP vapor can be detected within 3 min by naked eye and the film could be regenerated under simple solvent cleaning.