Using natural gas(NG)as the primary fuel helps alleviate the fossil fuel crisis while reducing engine soot and nitrogen oxide(NO_(X))emissions.In this paper,the influences of a novel split injection concept on an NG h...Using natural gas(NG)as the primary fuel helps alleviate the fossil fuel crisis while reducing engine soot and nitrogen oxide(NO_(X))emissions.In this paper,the influences of a novel split injection concept on an NG high pressure direct injection(HPDI)engine are examined.Four typical split injection strategies,namely split pre-injection of pilot diesel(PD)and NG,split post-injection of PD and NG,split pre-injection of NG,and split post-injection of PD,were developed to investigate the influences on combustion and emissions.Results revealed that split pre injection of NG enhanced the atomization of PD,whereas the split post-injection of NG lowered the temperature in the core region of the PD spray,resulting in the deterioration of combustion.The effect of the split injection strategy on indicated thermal efficiency exceeded 7.5%.Split pre-injection was favorable to enhancing thermal efficiency,whereas split post-injection was not.Ignition delay,combustion duration,and premixed combustion time proportion were affected by injection strategies by 3.8%,50%,and 19.7%,respectively.Split pre-injection increased CH_(4) emission in the exhaust.Split post-injection,especially split post-injection of PD and NG,reduced the unburned CH_(4) emission by approximately 30%.When the split post-injection ratio was less than 30%,the trade-off between NO_(X) and soot was interrupted.The distribution range of hydroxyl radicals was expanded by pre-injection,and NO_(X) was generated in the region where the NG jet hit the wall.This paper provides valuable insights into the optimization of HPDI injection parameters.展开更多
Purpose In order to achieve a high-precision measurement of the incident and the reflected power,a WR1800 rectangular waveguide directional coupler with high directivity and high power level has been in-house developed...Purpose In order to achieve a high-precision measurement of the incident and the reflected power,a WR1800 rectangular waveguide directional coupler with high directivity and high power level has been in-house developed.Multiple couplers will be installed in the 500-MHz high-power radio-frequency transmission lines delivering 200-kW continuous-wave power for the High Energy Photon Source(HEPS).Methods The directional coupler adopts the design scheme of primary and secondary transmission lines and coaxial coupling-head structure.The shape and dimensional parameters of the coupling head were carefully optimized by using microwave simulation codes.An optimum directivity of 64 dB was achieved in simulations.Results and conclusions A prototype coupler was subsequently manufactured,and its directivity was measured to be 48.2 dB following a rigorous calibration procedure,largely exceeding the design goal and the commercial product.The coupler was then connected to an existing 500-MHz klystron system,and a high-power test with short-circuit termination was conducted.The high directivity of the coupler was confirmed up to 200 kW.During the 6 hours of power aging with continuous-wave 200 kW in a standing-wave setup,no performance degradation was observed on the coupler.The coupler temperature was measured to be 20◦C above the ambient environment.The design requirements were comfortably fulfilled.These constitute thefirst in-house development of a large-size waveguide directional coupler with high directivity and high power level for HEPS.The design,fabrication,and performance tests of the directional coupler are presented.展开更多
An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w...An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.展开更多
In order to meet the needs of work in numerical weather forecast and in numerical simulations for climate change and ocean current, a kind of difference scheme in high precision in the time direction developed from th...In order to meet the needs of work in numerical weather forecast and in numerical simulations for climate change and ocean current, a kind of difference scheme in high precision in the time direction developed from the completely square-conservative difference scheme in explicit way is built by means of the Taylor expansion. A numerical test with 4-wave Rossby-Haurwitz waves on them and an application of them on the monthly mean current the of South China Sea are carried out, from which, it is found that not only do the new schemes have high harmony and approximate precision but also can the time step of the schemes be lengthened and can much computational time be saved. Therefore, they are worth generalizing and applying.展开更多
Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluat...Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.展开更多
Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten sy...Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability.Therefore,monitoring these critical multi-point temperature variations is essential.However,the unique design of the bushings,featuring insulation sheds of periodic shape,distorts infrared temperature measurements by introducing interference points.These interference points,dependent on the measurement's angle and distance,appear irregularly in infrared images,severely impacting the accuracy of multi-point temperature distribution assessments.To address this challenge,an anomaly detection method is proposed that adaptively identifies interference points.The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy.Compared with traditional methods,this approach presents two main advantages:adaptive identification capability,which enables it to recognise interference points and adapt to changing conditions,and unsupervised learning,which enables it to work effectively without requiring manually labelled data.Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method,achieving a 100%success rate in identifying localised overheating issues.The method has been integrated into high-voltage direct current transmission anomaly systems and can be used to monitor critical equipment,enhancing system reliability and safety.展开更多
Purpose A novel high-directivity high-power waveguide directional coupler(DC)working at 2998.8 MHz is developed for the High Energy Photon Source.It can help the phase control system to obtain a very accurate microwav...Purpose A novel high-directivity high-power waveguide directional coupler(DC)working at 2998.8 MHz is developed for the High Energy Photon Source.It can help the phase control system to obtain a very accurate microwave signal,which is very important to minimize the beam emittance.Methods The novel reversely placed T-type coupling piece helps to obtain a high directivity.The N-type high-vacuum feedthroughs for vacuum sealing instead of the traditional ceramic plate is beneficial to holding a higher peak power.The simulation and the high-power commissioning are accomplished in the Institute of High Energy Physics(IHEP),while the fabrication and the low-power test are conducted in cooperation with the manufacturer.Results Both the single-coupler and the dual-coupler DCs are developed with a directivity of more than 35 dB while keeping the coupling factor within 60±0.5 dB.Finally,69.4%of all the fifty-two mass produced DCs have got a directivity of more than 40 dB.Conclusion:The mature manufacturing process for mass production is obtained.The novel high-directivity high-power waveguide DC can be mass produced with an actually internationally leading performance.展开更多
An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insul...An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.展开更多
Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system...Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.展开更多
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g...Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.展开更多
Because of its light weight, broadband, and adaptable properties, smart material has been widely applied in the active vibration control (AVC) of flexible structures. Based on a firstorder shear deformation theory, ...Because of its light weight, broadband, and adaptable properties, smart material has been widely applied in the active vibration control (AVC) of flexible structures. Based on a firstorder shear deformation theory, by coupling the electrical and mechanical operation, a 4-node quadrilateral piezoelectric composite element with 24 degrees of freedom for generalized displacements and one electrical potential degree of freedom per piezoelectric layer was derived. Dynamic characteristics of a beam with discontinuously distributed piezoelectric sensors and actuators were presented. A linear quadratic regulator (LQR) feedback controller was designed to suppress the vibration of the beam in the state space using the high precise direct (HPD) integration method.展开更多
In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electr...In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.展开更多
More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in o...More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.展开更多
In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to ...In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to Henan multiple times,”Lu Jinlong,a tech-nician at the Qingnan Converter Station in Gonghe County,Hainan Tibetan Autonomous Prefecture,Qinghai,told reporters during a group interview on July 25.The Qingnan Converter Station is the starting point of the Qinghai-Henan±800-kilovolt(KV)ultra-high-voltage direct current(UHVDC)project.展开更多
Commutation failure(CF)is an inherent problem faced by line commutated converter high voltage direct current(LCC-HVDC)technology.To completely solve the problem of CF,we have proposed a novel hybrid commutated convert...Commutation failure(CF)is an inherent problem faced by line commutated converter high voltage direct current(LCC-HVDC)technology.To completely solve the problem of CF,we have proposed a novel hybrid commutated converter(HCC)technology based on reverse blocking integrated gate commutated thyristor,which can utilise two methods for commutation:enhanced grid voltage commutation and active turn-off forced com-mutation.In this paper,the topology and operating principle of HCC are proposed.Then,the control and protection strategy is designed based on the current variation trend under AC faults.To verify the effectiveness of HCC in mitigating CF,a 120-kV/360-MW HCC-HVDC model is built in PSCAD/EMTDC,adopting LCC at the rectifier side and HCC at the inverter side.Based on this model,HCC steady-state and fault transient stresses are analysed.Various AC faults are simulated and the performance of HCC-HVDC is compared with LCC-HVDC.Finally,the results show that the HCC topol-ogy and proposed control strategy can solve CF under all fault conditions with almost the same attributes as LCC,such as large capacity,low cost,low loss and high reliability,which is meaningful for the application of HCC to the HVDC transmission system.展开更多
As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out...As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.展开更多
Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inducta...Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inductance’characteristic of MMC impedance.Research indicates that this characteristic interacting with the capacitive characteristics of an AC system is the cause of high frequency resonance(HFR)in the Yu-E HVDC project.As the current controller is one of the main factors that affects the MMC impedance,a compensation control to imitate the paralleled impedance at the point of common coupling(PCC)is proposed.Therefore,the structure and parameter design of the compensation controller are core to realizing HFR suppression.There are two potentially risky frequency ranges of HFRs(around 700 Hz and 1.8 kHz)in the studied AC system within 2.0 kHz.The core concept of HFR suppression is to make the phase angle of MMC impedance smaller than 90◦in the two risky frequency ranges according to impedance stability theory.Hence,the design parameters aim to coordinate the phase angle of MMC impedance in the two risky frequency ranges.In this paper,three types of compensation controller are studied to suppress HFRs,namely,first-order low pass filter(LPF),second-order LPF,and third-order band pass filter.The results of parameter design show that the first-order LPF cannot suppress both HFRs simultaneously.The second-order LPF can suppress both HFRs,however,it introduces a DC component into the current control loop.Therefore,a high pass filter is added to form the recommended third-order controller.All parameter ranges of the compensation controller are derived using analytical expressions.Finally,the correctness of the parameter design is proofed using time-domain simulations.展开更多
It is always a bottleneck to design an effective algorithm for linear time-varying systems in engineering applications.For a class of systems,whose coefficients matrix is based on time-varying polynomial,a modified hi...It is always a bottleneck to design an effective algorithm for linear time-varying systems in engineering applications.For a class of systems,whose coefficients matrix is based on time-varying polynomial,a modified highly precise direct integration(VHPD-T method)was presented.Through introducing new variables and expanding dimensions,the system can be transformed into a timeinvariant system,in which the transfer matrix can be computed for once and used forever with a highly precise direct integration method.The method attains higher precision than the common methods(e.g.RK4 and power series)and high efficiency in computation.Some numerical examples demonstrate the validity and efficiency of the method proposed.展开更多
This study proposes the first high-capacity quantum secure direct communication(QSDC) with two-photon six-qubit hyperentangled Bell states in two longitudinal momentum and polarization degrees of freedom(DOFs) of phot...This study proposes the first high-capacity quantum secure direct communication(QSDC) with two-photon six-qubit hyperentangled Bell states in two longitudinal momentum and polarization degrees of freedom(DOFs) of photon pairs, which can be generated using two 0.5 mm-thick type-I β barium borate crystal slabs aligned one behind the other and an eight-hole screen. The secret message can be independently encoded on the photon pairs with 64 unitary operations in all three DOFs. This protocol has a higher capacity than previous QSDC protocols because each photon pair can carry 6 bits of information, not just 2 or 4 bits.Our QSDC protocol decreases the influence of decoherence from environment noise by exploiting the decoy photons to check the security of the transmission of the first photon sequence. Compared with two-way QSDC protocols, our QSDC protocol is immune to an attack by an eavesdropper using Trojan horse attack strategies because it is a one-way quantum communication.The QSDC protocol has good applications in the future quantum communication because of all these features.展开更多
An analytical direct tunneling gate current model for cylindrical surrounding gate(CSG) MOSFETs with high-k gate stacks is developed. It is found that the direct tunneling gate current is a strong function of the g...An analytical direct tunneling gate current model for cylindrical surrounding gate(CSG) MOSFETs with high-k gate stacks is developed. It is found that the direct tunneling gate current is a strong function of the gate's oxide thickness, but that it is less affected by the change in channel radius. It is also revealed that when the thickness of the equivalent oxide is constant, the thinner the first layer, the smaller the direct tunneling gate current.Moreover, it can be seen that the dielectric with a higher dielectric constant shows a lower tunneling current than expected. The accuracy of the analytical model is verified by the good agreement of its results with those obtained by the three-dimensional numerical device simulator ISE.展开更多
基金Supported by the National Natural Science Foundation of China(No.51909154)Shanghai Engineering Research Center of Ship Intelligent Maintenance and Energy Efficiency(No.20DZ2252300).
文摘Using natural gas(NG)as the primary fuel helps alleviate the fossil fuel crisis while reducing engine soot and nitrogen oxide(NO_(X))emissions.In this paper,the influences of a novel split injection concept on an NG high pressure direct injection(HPDI)engine are examined.Four typical split injection strategies,namely split pre-injection of pilot diesel(PD)and NG,split post-injection of PD and NG,split pre-injection of NG,and split post-injection of PD,were developed to investigate the influences on combustion and emissions.Results revealed that split pre injection of NG enhanced the atomization of PD,whereas the split post-injection of NG lowered the temperature in the core region of the PD spray,resulting in the deterioration of combustion.The effect of the split injection strategy on indicated thermal efficiency exceeded 7.5%.Split pre-injection was favorable to enhancing thermal efficiency,whereas split post-injection was not.Ignition delay,combustion duration,and premixed combustion time proportion were affected by injection strategies by 3.8%,50%,and 19.7%,respectively.Split pre-injection increased CH_(4) emission in the exhaust.Split post-injection,especially split post-injection of PD and NG,reduced the unburned CH_(4) emission by approximately 30%.When the split post-injection ratio was less than 30%,the trade-off between NO_(X) and soot was interrupted.The distribution range of hydroxyl radicals was expanded by pre-injection,and NO_(X) was generated in the region where the NG jet hit the wall.This paper provides valuable insights into the optimization of HPDI injection parameters.
文摘Purpose In order to achieve a high-precision measurement of the incident and the reflected power,a WR1800 rectangular waveguide directional coupler with high directivity and high power level has been in-house developed.Multiple couplers will be installed in the 500-MHz high-power radio-frequency transmission lines delivering 200-kW continuous-wave power for the High Energy Photon Source(HEPS).Methods The directional coupler adopts the design scheme of primary and secondary transmission lines and coaxial coupling-head structure.The shape and dimensional parameters of the coupling head were carefully optimized by using microwave simulation codes.An optimum directivity of 64 dB was achieved in simulations.Results and conclusions A prototype coupler was subsequently manufactured,and its directivity was measured to be 48.2 dB following a rigorous calibration procedure,largely exceeding the design goal and the commercial product.The coupler was then connected to an existing 500-MHz klystron system,and a high-power test with short-circuit termination was conducted.The high directivity of the coupler was confirmed up to 200 kW.During the 6 hours of power aging with continuous-wave 200 kW in a standing-wave setup,no performance degradation was observed on the coupler.The coupler temperature was measured to be 20◦C above the ambient environment.The design requirements were comfortably fulfilled.These constitute thefirst in-house development of a large-size waveguide directional coupler with high directivity and high power level for HEPS.The design,fabrication,and performance tests of the directional coupler are presented.
文摘An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.
文摘In order to meet the needs of work in numerical weather forecast and in numerical simulations for climate change and ocean current, a kind of difference scheme in high precision in the time direction developed from the completely square-conservative difference scheme in explicit way is built by means of the Taylor expansion. A numerical test with 4-wave Rossby-Haurwitz waves on them and an application of them on the monthly mean current the of South China Sea are carried out, from which, it is found that not only do the new schemes have high harmony and approximate precision but also can the time step of the schemes be lengthened and can much computational time be saved. Therefore, they are worth generalizing and applying.
基金supported by the Technology Project of the State Grid Corporation Headquarters Management(Contract No.5100-202158467A-0-0-00).
文摘Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.
基金National Natural Science Foundation of China,Grant/Award Numbers:62106033,42367066。
文摘Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability.Therefore,monitoring these critical multi-point temperature variations is essential.However,the unique design of the bushings,featuring insulation sheds of periodic shape,distorts infrared temperature measurements by introducing interference points.These interference points,dependent on the measurement's angle and distance,appear irregularly in infrared images,severely impacting the accuracy of multi-point temperature distribution assessments.To address this challenge,an anomaly detection method is proposed that adaptively identifies interference points.The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy.Compared with traditional methods,this approach presents two main advantages:adaptive identification capability,which enables it to recognise interference points and adapt to changing conditions,and unsupervised learning,which enables it to work effectively without requiring manually labelled data.Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method,achieving a 100%success rate in identifying localised overheating issues.The method has been integrated into high-voltage direct current transmission anomaly systems and can be used to monitor critical equipment,enhancing system reliability and safety.
基金Funded by Youth Innovation Promotion Association CAS(2020015)
文摘Purpose A novel high-directivity high-power waveguide directional coupler(DC)working at 2998.8 MHz is developed for the High Energy Photon Source.It can help the phase control system to obtain a very accurate microwave signal,which is very important to minimize the beam emittance.Methods The novel reversely placed T-type coupling piece helps to obtain a high directivity.The N-type high-vacuum feedthroughs for vacuum sealing instead of the traditional ceramic plate is beneficial to holding a higher peak power.The simulation and the high-power commissioning are accomplished in the Institute of High Energy Physics(IHEP),while the fabrication and the low-power test are conducted in cooperation with the manufacturer.Results Both the single-coupler and the dual-coupler DCs are developed with a directivity of more than 35 dB while keeping the coupling factor within 60±0.5 dB.Finally,69.4%of all the fifty-two mass produced DCs have got a directivity of more than 40 dB.Conclusion:The mature manufacturing process for mass production is obtained.The novel high-directivity high-power waveguide DC can be mass produced with an actually internationally leading performance.
基金Manitoba Hydro for funding and supporting this research
文摘An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.
文摘Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.
基金This project is funded by the Dongying Science Development Fund Project(DJ2021013).
文摘Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.
基金Supported by the National Natural Science Foundation of China (51079027).
文摘Because of its light weight, broadband, and adaptable properties, smart material has been widely applied in the active vibration control (AVC) of flexible structures. Based on a firstorder shear deformation theory, by coupling the electrical and mechanical operation, a 4-node quadrilateral piezoelectric composite element with 24 degrees of freedom for generalized displacements and one electrical potential degree of freedom per piezoelectric layer was derived. Dynamic characteristics of a beam with discontinuously distributed piezoelectric sensors and actuators were presented. A linear quadratic regulator (LQR) feedback controller was designed to suppress the vibration of the beam in the state space using the high precise direct (HPD) integration method.
基金supported by the General Program of Chinese Postdoctoral Science Foundation under Grant No.2012M511595
文摘In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.
文摘More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.
文摘In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to Henan multiple times,”Lu Jinlong,a tech-nician at the Qingnan Converter Station in Gonghe County,Hainan Tibetan Autonomous Prefecture,Qinghai,told reporters during a group interview on July 25.The Qingnan Converter Station is the starting point of the Qinghai-Henan±800-kilovolt(KV)ultra-high-voltage direct current(UHVDC)project.
基金National Natural Science Foundation of China-State Grid Corporation Joint Fund for Smart Grid,Grant/Award Number:U2166602。
文摘Commutation failure(CF)is an inherent problem faced by line commutated converter high voltage direct current(LCC-HVDC)technology.To completely solve the problem of CF,we have proposed a novel hybrid commutated converter(HCC)technology based on reverse blocking integrated gate commutated thyristor,which can utilise two methods for commutation:enhanced grid voltage commutation and active turn-off forced com-mutation.In this paper,the topology and operating principle of HCC are proposed.Then,the control and protection strategy is designed based on the current variation trend under AC faults.To verify the effectiveness of HCC in mitigating CF,a 120-kV/360-MW HCC-HVDC model is built in PSCAD/EMTDC,adopting LCC at the rectifier side and HCC at the inverter side.Based on this model,HCC steady-state and fault transient stresses are analysed.Various AC faults are simulated and the performance of HCC-HVDC is compared with LCC-HVDC.Finally,the results show that the HCC topol-ogy and proposed control strategy can solve CF under all fault conditions with almost the same attributes as LCC,such as large capacity,low cost,low loss and high reliability,which is meaningful for the application of HCC to the HVDC transmission system.
基金This work was supported by National Natural Science Foundation of China(No.51261130471).
文摘As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.
基金supported by the National Natural Science Foundation of China(No.U1866210).
文摘Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inductance’characteristic of MMC impedance.Research indicates that this characteristic interacting with the capacitive characteristics of an AC system is the cause of high frequency resonance(HFR)in the Yu-E HVDC project.As the current controller is one of the main factors that affects the MMC impedance,a compensation control to imitate the paralleled impedance at the point of common coupling(PCC)is proposed.Therefore,the structure and parameter design of the compensation controller are core to realizing HFR suppression.There are two potentially risky frequency ranges of HFRs(around 700 Hz and 1.8 kHz)in the studied AC system within 2.0 kHz.The core concept of HFR suppression is to make the phase angle of MMC impedance smaller than 90◦in the two risky frequency ranges according to impedance stability theory.Hence,the design parameters aim to coordinate the phase angle of MMC impedance in the two risky frequency ranges.In this paper,three types of compensation controller are studied to suppress HFRs,namely,first-order low pass filter(LPF),second-order LPF,and third-order band pass filter.The results of parameter design show that the first-order LPF cannot suppress both HFRs simultaneously.The second-order LPF can suppress both HFRs,however,it introduces a DC component into the current control loop.Therefore,a high pass filter is added to form the recommended third-order controller.All parameter ranges of the compensation controller are derived using analytical expressions.Finally,the correctness of the parameter design is proofed using time-domain simulations.
基金supported by the National Natural Science Foundation of China(Grant No.50876066)
文摘It is always a bottleneck to design an effective algorithm for linear time-varying systems in engineering applications.For a class of systems,whose coefficients matrix is based on time-varying polynomial,a modified highly precise direct integration(VHPD-T method)was presented.Through introducing new variables and expanding dimensions,the system can be transformed into a timeinvariant system,in which the transfer matrix can be computed for once and used forever with a highly precise direct integration method.The method attains higher precision than the common methods(e.g.RK4 and power series)and high efficiency in computation.Some numerical examples demonstrate the validity and efficiency of the method proposed.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11474027, 61675028, and 11674033)the Fundamental Research Funds for the Central Universities (Grant No. 2015KJJCA01)the National High Technology Research and Development Program of China(Grant No. 2013AA122902)
文摘This study proposes the first high-capacity quantum secure direct communication(QSDC) with two-photon six-qubit hyperentangled Bell states in two longitudinal momentum and polarization degrees of freedom(DOFs) of photon pairs, which can be generated using two 0.5 mm-thick type-I β barium borate crystal slabs aligned one behind the other and an eight-hole screen. The secret message can be independently encoded on the photon pairs with 64 unitary operations in all three DOFs. This protocol has a higher capacity than previous QSDC protocols because each photon pair can carry 6 bits of information, not just 2 or 4 bits.Our QSDC protocol decreases the influence of decoherence from environment noise by exploiting the decoy photons to check the security of the transmission of the first photon sequence. Compared with two-way QSDC protocols, our QSDC protocol is immune to an attack by an eavesdropper using Trojan horse attack strategies because it is a one-way quantum communication.The QSDC protocol has good applications in the future quantum communication because of all these features.
基金Project supported by the National Natural Science Foundation of China(Nos.61076101,61204092)the Fundamental Research Fundsfor the Central Universities of China(No.K50511250001)
文摘An analytical direct tunneling gate current model for cylindrical surrounding gate(CSG) MOSFETs with high-k gate stacks is developed. It is found that the direct tunneling gate current is a strong function of the gate's oxide thickness, but that it is less affected by the change in channel radius. It is also revealed that when the thickness of the equivalent oxide is constant, the thinner the first layer, the smaller the direct tunneling gate current.Moreover, it can be seen that the dielectric with a higher dielectric constant shows a lower tunneling current than expected. The accuracy of the analytical model is verified by the good agreement of its results with those obtained by the three-dimensional numerical device simulator ISE.