The high thermal conductivity of the nanoparticles in hybrid nanofluids results in enhanced thermal conductivity associated with their base fluids.Enhanced heat transfer is a result of this high thermal conductivity,w...The high thermal conductivity of the nanoparticles in hybrid nanofluids results in enhanced thermal conductivity associated with their base fluids.Enhanced heat transfer is a result of this high thermal conductivity,which has significant applications in heat exchangers and engineering devices.To optimize heat transfer,a liquid film of Cu and TiO_(2)hybrid nanofluid behind a stretching sheet in a variable porous medium is being considered due to its importance.The nature of the fluid is considered time-dependent and the thickness of the liquid film is measured variable adjustable with the variable porous space and favorable for the uniform flow of the liquid film.The solution of the problem is acquired using the homotopy analysis method HAM,and the artificial neural network ANN is applied to obtain detailed information in the form of error estimation and validations using the fitting curve analysis.HAM data is utilized to train the ANN in this study,which uses Cu and TiO_(2)hybrid nanofluids in a variable porous space for unsteady thin film flow,and it is used to train the ANN.The results indicate that Cu and TiO_(2)play a greater role in boosting the rate.展开更多
This study characterizes and optimizes natural convection heat transfer of two Newtonian Al2O3 and Ti O2/water nano fluids in a cylindrical enclosure. Nusselt number(Nu) of nano fluids in relation to Rayleigh number(R...This study characterizes and optimizes natural convection heat transfer of two Newtonian Al2O3 and Ti O2/water nano fluids in a cylindrical enclosure. Nusselt number(Nu) of nano fluids in relation to Rayleigh number(Ra) for different concentrations of nano fluids is investigated at different con figurations and orientations of the enclosure.Results show that adding nanoparticles to water has a negligible or even adverse in fluence upon natural convection heat transfer of water: only a slight increase in natural convection heat transfer of Al2O3/water is observed,while natural convection heat transfer for TiO2/water nano fluid is inferior to that for the base fluid. Results also reveal that at low Ra, the likelihood of enhancement in natural convection heat transfer is more than at high Ra: at low Ra, inclination angle, aspect ratio of the enclosure and nanoparticle concentration in fluence natural convection heat transfer more pronouncedly than that in high Ra.展开更多
Examples of heat transfer and heat-work conversion are optimized with entropy generation and entransy loss,respectively based on the generalized heat transfer law in this paper.The applicability of entropy generation ...Examples of heat transfer and heat-work conversion are optimized with entropy generation and entransy loss,respectively based on the generalized heat transfer law in this paper.The applicability of entropy generation and entransy loss evaluation in these optimization problems is analyzed and discussed.The results show that the entransy loss rate reduces to the entransy dissipation rate in heat transfer processes,and that the entransy loss evaluation is effective for heat transfer optimization.However,the maximum heat transfer rate does not correspond to the minimum entropy generation rate with prescribed heat transfer temperature difference,which indicates that the entropy generation minimization is not always appropriate to heat transfer optimization.For heat-work conversion processes,the maximum entransy loss rate and the minimum entropy generation rate both correspond to the maximum output power,and they are both appropriate to the optimization of the heat-work conversion processes discussed in this paper.展开更多
In order to increase cooling or heating efficiency,a porous computational fluid dynamics(CFD)model is employed to predict the thermo-fluid status and optimize the placement of outdoor units.A full scale model is est...In order to increase cooling or heating efficiency,a porous computational fluid dynamics(CFD)model is employed to predict the thermo-fluid status and optimize the placement of outdoor units.A full scale model is established to validate the accuracy of CFD simulation in terms of velocity and temperature distributions.The comparison between the measurement and the simulation shows a good agreement.By evaluating the condensers' sucked air temperature with CFD for three units installed in a row,it is found that the minimum separation distance among neighboring units is 0.2 m;a vertical wall should be apart from the unit line by at least 0.8 m;and large different operating pressures among units do not impact the flow rate and the heat transfer of the other units meaningfully.展开更多
In this paper,we propose a simple energy decaying iterative thresholding algorithm to solve the heat transfer problem.The material domain is implicitly represented by its characteristic function,and the problem is for...In this paper,we propose a simple energy decaying iterative thresholding algorithm to solve the heat transfer problem.The material domain is implicitly represented by its characteristic function,and the problem is formulated into a minimum-minimum problem.We prove that the energy is decreasing in each iteration.Numerical experiments for two types the heat transfer problems(volume to point and volume to sides)are performed to demonstrate the effectiveness of the proposed methods.展开更多
The one-stream hybrid thermal network is analyzed and discussed based on the entransy theory,and the results are compared with those from the entropy generation optimization.The theoretical analysis indicates that the...The one-stream hybrid thermal network is analyzed and discussed based on the entransy theory,and the results are compared with those from the entropy generation optimization.The theoretical analysis indicates that the minimum heat-flow-weighted temperature of the thermal networks corresponds to the minimum entransy dissipation rate and the minimum thermal resistance.For a simple hybrid thermal network consisting of three thermal components,the expression of entransy dissipation is conducted,and the heat transfer area and the mass flow rate are calculated and optimized.The optimal results are obtained in order to minimize the entransy dissipation and the thermal resistance.The optimal results are calculated for various combinations,such as series connection,parallel connection and other hybrid connections.The numerical results are in accordance with the theoretical analysis.Both the theoretical analysis and the numerical results show that the minimum entransy dissipation and the minimum thermal resistance correspond to the minimum heat-flow-weighted temperature of the thermal networks while the minimum entropy generation does not.展开更多
Based on constructal theory,the constructs of the leaf-like fins are optimized by taking minimum entransy dissipation rate(for the fixed total thermal current,i.e.,the equivalent thermal resistance)as optimization obj...Based on constructal theory,the constructs of the leaf-like fins are optimized by taking minimum entransy dissipation rate(for the fixed total thermal current,i.e.,the equivalent thermal resistance)as optimization objective.The optimal constructs of the leaf-like fins with minimum dimensionless equivalent thermal resistance are obtained.The results show that there exists an optimal elemental leaf-like fin number,which leads to an optimal global heat conduction performance of the first order leaf-like fin.The Biot number has little effects on the optimal elemental fin number,optimal ratios of length and width of the elemental and first order leaf-like fins;with the increase of the thermal conductivity ratio of the vein and blade,the optimal elemental fin number and optimal ratio of the length and width of the elemental leaf-like fin increase,and the optimal shape of the first order leaf-like fin becomes tubbier.The optimal construct based on entransy dissipation rate minimization is obviously different from that based on maximum temperature difference minimization.The dimensionless equivalent thermal resistance based on entransy dissipation rate minimization is reduced by 11.54%compared to that based on maximum temperature difference minimization,and the global heat conduction performance of the leaf-like fin is effectively improved.For the same volumes of the elemental and first order leaf-like fins,the minimum dimensionless equivalent thermal resistance of the first order of the leaf-like fin is reduced by 30.10%compared to that of the elemental leaf-like fin,and the global heat conduction performance of the first order leaf-like fin is obviously better than that of the elemental leaf-like fin.Essentially,this is because the temperature gradient field of the first order leaf-like fin based on entransy dissipation rate minimization is more homogenous than that of the elemental leaf-like fin.The dimensionless equivalent thermal resistance defined based on entransy dissipation rate reflects the average heat transfer performance of the leaf-like fin,and can provide some guidelines for the thermal design of the fins from the viewpoint of heat transfer optimization.展开更多
文摘The high thermal conductivity of the nanoparticles in hybrid nanofluids results in enhanced thermal conductivity associated with their base fluids.Enhanced heat transfer is a result of this high thermal conductivity,which has significant applications in heat exchangers and engineering devices.To optimize heat transfer,a liquid film of Cu and TiO_(2)hybrid nanofluid behind a stretching sheet in a variable porous medium is being considered due to its importance.The nature of the fluid is considered time-dependent and the thickness of the liquid film is measured variable adjustable with the variable porous space and favorable for the uniform flow of the liquid film.The solution of the problem is acquired using the homotopy analysis method HAM,and the artificial neural network ANN is applied to obtain detailed information in the form of error estimation and validations using the fitting curve analysis.HAM data is utilized to train the ANN in this study,which uses Cu and TiO_(2)hybrid nanofluids in a variable porous space for unsteady thin film flow,and it is used to train the ANN.The results indicate that Cu and TiO_(2)play a greater role in boosting the rate.
文摘This study characterizes and optimizes natural convection heat transfer of two Newtonian Al2O3 and Ti O2/water nano fluids in a cylindrical enclosure. Nusselt number(Nu) of nano fluids in relation to Rayleigh number(Ra) for different concentrations of nano fluids is investigated at different con figurations and orientations of the enclosure.Results show that adding nanoparticles to water has a negligible or even adverse in fluence upon natural convection heat transfer of water: only a slight increase in natural convection heat transfer of Al2O3/water is observed,while natural convection heat transfer for TiO2/water nano fluid is inferior to that for the base fluid. Results also reveal that at low Ra, the likelihood of enhancement in natural convection heat transfer is more than at high Ra: at low Ra, inclination angle, aspect ratio of the enclosure and nanoparticle concentration in fluence natural convection heat transfer more pronouncedly than that in high Ra.
基金supported by the Natural Science Foundation of China(Grant No. 51136001)the Tsinghua University Initiative ScientificResearch Program
文摘Examples of heat transfer and heat-work conversion are optimized with entropy generation and entransy loss,respectively based on the generalized heat transfer law in this paper.The applicability of entropy generation and entransy loss evaluation in these optimization problems is analyzed and discussed.The results show that the entransy loss rate reduces to the entransy dissipation rate in heat transfer processes,and that the entransy loss evaluation is effective for heat transfer optimization.However,the maximum heat transfer rate does not correspond to the minimum entropy generation rate with prescribed heat transfer temperature difference,which indicates that the entropy generation minimization is not always appropriate to heat transfer optimization.For heat-work conversion processes,the maximum entransy loss rate and the minimum entropy generation rate both correspond to the maximum output power,and they are both appropriate to the optimization of the heat-work conversion processes discussed in this paper.
文摘In order to increase cooling or heating efficiency,a porous computational fluid dynamics(CFD)model is employed to predict the thermo-fluid status and optimize the placement of outdoor units.A full scale model is established to validate the accuracy of CFD simulation in terms of velocity and temperature distributions.The comparison between the measurement and the simulation shows a good agreement.By evaluating the condensers' sucked air temperature with CFD for three units installed in a row,it is found that the minimum separation distance among neighboring units is 0.2 m;a vertical wall should be apart from the unit line by at least 0.8 m;and large different operating pressures among units do not impact the flow rate and the heat transfer of the other units meaningfully.
基金support from National Natural Science Foundation of China(NSFC)grant(No.12271461)the key project of NSFC(No.12131010)+1 种基金the Hong Kong Research Grants Council GRF(GRF grants Nos.16308421,16305819,16303318)the University Development Fund from The Chinese University of Hong Kong,Shenzhen(UDF01002028).
文摘In this paper,we propose a simple energy decaying iterative thresholding algorithm to solve the heat transfer problem.The material domain is implicitly represented by its characteristic function,and the problem is formulated into a minimum-minimum problem.We prove that the energy is decreasing in each iteration.Numerical experiments for two types the heat transfer problems(volume to point and volume to sides)are performed to demonstrate the effectiveness of the proposed methods.
基金supported by the Natural Science Foundation of China(Grant No. 51136001)the Tsinghua University Initiative Scientific Research Program
文摘The one-stream hybrid thermal network is analyzed and discussed based on the entransy theory,and the results are compared with those from the entropy generation optimization.The theoretical analysis indicates that the minimum heat-flow-weighted temperature of the thermal networks corresponds to the minimum entransy dissipation rate and the minimum thermal resistance.For a simple hybrid thermal network consisting of three thermal components,the expression of entransy dissipation is conducted,and the heat transfer area and the mass flow rate are calculated and optimized.The optimal results are obtained in order to minimize the entransy dissipation and the thermal resistance.The optimal results are calculated for various combinations,such as series connection,parallel connection and other hybrid connections.The numerical results are in accordance with the theoretical analysis.Both the theoretical analysis and the numerical results show that the minimum entransy dissipation and the minimum thermal resistance correspond to the minimum heat-flow-weighted temperature of the thermal networks while the minimum entropy generation does not.
基金supported by the National Natural Science Foundation of China(Grant No.51176203)the Natural Science Foundation of Naval University of Engineering(Grant No.HGDYDJJ10011)the Natural Science Foundation for Youngsters of Naval University of Engineering(Grant No.HGDQNJJ10017)
文摘Based on constructal theory,the constructs of the leaf-like fins are optimized by taking minimum entransy dissipation rate(for the fixed total thermal current,i.e.,the equivalent thermal resistance)as optimization objective.The optimal constructs of the leaf-like fins with minimum dimensionless equivalent thermal resistance are obtained.The results show that there exists an optimal elemental leaf-like fin number,which leads to an optimal global heat conduction performance of the first order leaf-like fin.The Biot number has little effects on the optimal elemental fin number,optimal ratios of length and width of the elemental and first order leaf-like fins;with the increase of the thermal conductivity ratio of the vein and blade,the optimal elemental fin number and optimal ratio of the length and width of the elemental leaf-like fin increase,and the optimal shape of the first order leaf-like fin becomes tubbier.The optimal construct based on entransy dissipation rate minimization is obviously different from that based on maximum temperature difference minimization.The dimensionless equivalent thermal resistance based on entransy dissipation rate minimization is reduced by 11.54%compared to that based on maximum temperature difference minimization,and the global heat conduction performance of the leaf-like fin is effectively improved.For the same volumes of the elemental and first order leaf-like fins,the minimum dimensionless equivalent thermal resistance of the first order of the leaf-like fin is reduced by 30.10%compared to that of the elemental leaf-like fin,and the global heat conduction performance of the first order leaf-like fin is obviously better than that of the elemental leaf-like fin.Essentially,this is because the temperature gradient field of the first order leaf-like fin based on entransy dissipation rate minimization is more homogenous than that of the elemental leaf-like fin.The dimensionless equivalent thermal resistance defined based on entransy dissipation rate reflects the average heat transfer performance of the leaf-like fin,and can provide some guidelines for the thermal design of the fins from the viewpoint of heat transfer optimization.