期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Equivalent Impedance Parameter Calculation of Three-phase Symmetrical Loads for Harmonic Source Location 被引量:2
1
作者 Yi Zhang Bijie Liu +2 位作者 Caihua Lin Zhenguo Shao Yuncong Xu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期251-260,共10页
The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominat... The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominator.These outliers can result in inaccuracy and unreliability of harmonic source location.To address this issue,this paper proposes an innovative method of equivalent impedance parameter calculation of three-phase symmetrical loads that avoid outliers.The correctness and effectiveness of the proposed method are verified by simulations on Simulink using actual monitoring data.The results show that the proposed method is not only simple and easy to implement but also highly accurate. 展开更多
关键词 abc-αβtransformation equivalent impedance parameters of load harmonic source location nonlinear load power quality
原文传递
Analysis of DC-Side Harmonic Characteristics and Optimization of Filter Design for Hybrid DC Transmission Systems
2
作者 Chunyan Li Luo Li +2 位作者 Yushuang Li Yong Jia Wenyan Li 《Energy Engineering》 2025年第10期4313-4330,共18页
To accelerate the large-scale integration of renewable energy and support the strategic goals of“carbon peaking and carbon neutrality,”High Voltage Direct Current(HVDC)transmission technology has made significant br... To accelerate the large-scale integration of renewable energy and support the strategic goals of“carbon peaking and carbon neutrality,”High Voltage Direct Current(HVDC)transmission technology has made significant breakthroughs.Among the various approaches,a hybrid DC transmission system that combines a line-commutated converter(LCC)and a voltage source converter(VSC)retains the inherent fault self-clearing capability of the LCC topology while mitigating the risk of commutation failure when connected to a weak grid.In this paper,based on the harmonic generation mechanisms of hybrid DC transmission systems,an improved 3-pulse harmonic source model of the LCC and a dynamic phase-sequence harmonic analysis model of the VSC are developed.The integrated harmonic model demonstrates strong adaptability in accurately calculating DC-side harmonics under the influence of power imbalances and background harmonics.Based on this model,the fundamental characteristics of DC-side harmonics in hybrid DC transmission systems are analyzed.To mitigate harmonic effects,this paper proposes an LCLC-trap2 high-order filter structure with parallel RC damping circuits and a co-optimized design of filter parameters.Finally,a±500 kV hybrid DC transmission systemismodeled using theMATLAB/Simulink platform,and the harmonic filtering performances of the conventional LC filter,the Butterworth filter,and the proposed filter are simulated and compared.The results verify that the proposed filter offers superior performance in suppressing low-order harmonics under nonideal operating conditions. 展开更多
关键词 Hybrid HVDC transmission system 3-pulse harmonic source model FILTER parameter optimization
在线阅读 下载PDF
Study of the second harmonic sound field from a circular piston source and the influence in the nonlinearity parameter tomography 被引量:1
3
作者 ZHANG Dong CHEN Xi GONG Xiufen (State Key Lab . of Modern Acoustics, Institute of Acoustics, Nanjing University Nanjing 210093) 《Chinese Journal of Acoustics》 1999年第3期272-279,共8页
In the nonlinearity parameter B/A tomography using the second harmonic wav, it is very important to analyze the ultrasonic field of the transducer, especially the generation of the second harmonic wave in the near... In the nonlinearity parameter B/A tomography using the second harmonic wav, it is very important to analyze the ultrasonic field of the transducer, especially the generation of the second harmonic wave in the nearfield. In this paper, the theoretical study and experimental measurements of the second harmoinc pressure field from a circular piston source are performed.And the effect on the nonlinearity parameter tomograaphy is discussed. The results will be used to decrease the error of reconstruction in nonlinearity parameter tomography and bring the ultrasoinc diagnosis a step forward 展开更多
关键词 MHz Study of the second harmonic sound field from a circular piston source and the influence in the nonlinearity parameter tomography
原文传递