An ionospheric heating experiment involving an O mode pump wave was carried out at European Incoherent Scatter Scientific Association site in Troms?. The observation of the ultra high frequency radar illustrates the ...An ionospheric heating experiment involving an O mode pump wave was carried out at European Incoherent Scatter Scientific Association site in Troms?. The observation of the ultra high frequency radar illustrates the systematic variations of the enhanced ion line and plasma line in altitude and intensity as a function of the pump frequency. The analysis shows that those altitude variations are due to the thermal effect, and the intensity variations of the enhanced ion line are dependent on whether or not the enhanced ion acoustic wave satisfy the Bragg condition of radar. Moreover, a prediction that if the enhancement in electron temperature is suppressed,those systematic variations will be absent, is given.展开更多
In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power s...In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.However,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Afterwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued impedance matrix.Based on the derived impedance matrix,the system harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key factors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model.展开更多
Electron cyclotron emission imaging(ECEI) can provide measurements of 2D electron temperature fluctuation with high temporal and spatial resolution in magnetic fusion plasma devices. Two ECEI systems located in diff...Electron cyclotron emission imaging(ECEI) can provide measurements of 2D electron temperature fluctuation with high temporal and spatial resolution in magnetic fusion plasma devices. Two ECEI systems located in different toroidal ports with 67.5 degree separation have been implemented on J-TEXT to study the 3D structure of magnetohydrodynamic(MHD) instabilities. Each system consists of 12(vertical) × 16(horizontal) = 192 channels and the image of the 2nd harmonic X-mode electron cyclotron emission can be captured continuously in the core plasma region. The field curvature adjustment lens concept is developed to control the imaging plane for receiving optics of the ECEI systems. Field curvature of the image can be controlled to match the emission layer. Consequently, a quasi-3D image of the MHD instability in the core of the plasma has been achieved.展开更多
A simulation code that executes the tracking of longitudinal oscillations of the bunches for the double rf system of the Hefei Light Source Ⅱ Project (HLS-Ⅱ) is presented to estimate the mean beam lifetime and the...A simulation code that executes the tracking of longitudinal oscillations of the bunches for the double rf system of the Hefei Light Source Ⅱ Project (HLS-Ⅱ) is presented to estimate the mean beam lifetime and the Robinson instabilities. The tracking results show that the mean beam lifetime is in agreement with the analytical results and the system is stable when we tune the harmonic cavity in the optimum lengthening conditions. Moreover, the simulated results of the asymmetric fill pattern show that some bunches are compressed only with a 7% gap (3 gaps), which will lead to the reduction in the mean bunch lengthening and potential beam lifetime. It is demonstrated that HLS-Ⅱ with a passive higher harmonic cavity is not suitable for operating in an asymmetric fill pattern.展开更多
基金supported by China(China Research Institute of Radio Wave Propagation)Finland(Suomen Akatemia of Finland)+3 种基金Japan(the National Institute of Polar Research of Japan and Institute for Space-Earth Environmental Research at Nagoya University)Norway(Norges Forkningsrad of Norway)Sweden(the Swedish Research Council)the UK(the Natural Environment Research Council)
文摘An ionospheric heating experiment involving an O mode pump wave was carried out at European Incoherent Scatter Scientific Association site in Troms?. The observation of the ultra high frequency radar illustrates the systematic variations of the enhanced ion line and plasma line in altitude and intensity as a function of the pump frequency. The analysis shows that those altitude variations are due to the thermal effect, and the intensity variations of the enhanced ion line are dependent on whether or not the enhanced ion acoustic wave satisfy the Bragg condition of radar. Moreover, a prediction that if the enhancement in electron temperature is suppressed,those systematic variations will be absent, is given.
文摘In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.However,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Afterwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued impedance matrix.Based on the derived impedance matrix,the system harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key factors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model.
基金supported by the National Magnetic Confinement Fusion Science Program of China under Grant Nos.2013GB106002 and 2014GB109002National Natural Science Foundation of China under Grant Nos.10990210 and 11275200
文摘Electron cyclotron emission imaging(ECEI) can provide measurements of 2D electron temperature fluctuation with high temporal and spatial resolution in magnetic fusion plasma devices. Two ECEI systems located in different toroidal ports with 67.5 degree separation have been implemented on J-TEXT to study the 3D structure of magnetohydrodynamic(MHD) instabilities. Each system consists of 12(vertical) × 16(horizontal) = 192 channels and the image of the 2nd harmonic X-mode electron cyclotron emission can be captured continuously in the core plasma region. The field curvature adjustment lens concept is developed to control the imaging plane for receiving optics of the ECEI systems. Field curvature of the image can be controlled to match the emission layer. Consequently, a quasi-3D image of the MHD instability in the core of the plasma has been achieved.
基金Supported by National Natural Science Foundation of China(10675116)Major State Basic Research Development Programme of China(2011CB808301)
文摘A simulation code that executes the tracking of longitudinal oscillations of the bunches for the double rf system of the Hefei Light Source Ⅱ Project (HLS-Ⅱ) is presented to estimate the mean beam lifetime and the Robinson instabilities. The tracking results show that the mean beam lifetime is in agreement with the analytical results and the system is stable when we tune the harmonic cavity in the optimum lengthening conditions. Moreover, the simulated results of the asymmetric fill pattern show that some bunches are compressed only with a 7% gap (3 gaps), which will lead to the reduction in the mean bunch lengthening and potential beam lifetime. It is demonstrated that HLS-Ⅱ with a passive higher harmonic cavity is not suitable for operating in an asymmetric fill pattern.