期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
A Novel Half-Bridge Power Supply for High Speed Drilling Electrical Discharge Machining
1
作者 He Huang Jicheng Bai +1 位作者 Zesheng Lu Yongfeng Guo 《Journal of Electromagnetic Analysis and Applications》 2009年第2期108-113,共6页
High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manu... High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manufacturing large aspect ratio holes for hard-to-machine material. The power supplies of HSDEDM providing high power applica-tions can have different topologies. In this paper, a novel Pulsed-Width-Modulated (PWM) half-bridge HSDEDM power supply that achieves Zero-Voltage-Switching (ZVS) for switches and Zero-Current-Switching (ZCS) for the dis-charge gap has been developed. This power supply has excellent features that include minimal component count and inherent protection under short circuit conditions. This topology has an energy conservation feature and removes the need for output bulk capacitors and resistances. Energy used in the erosion process will be controlled by the switched IGBTs in the half-bridge network and be transferred to the gap between the tool and work-piece. The relative tool wear and machining speed of our proposed topology have been compared with that of a normal power supply with current limiting resistances. 展开更多
关键词 High Speed DRILLING Electrical Discharge Machining half-bridge Power Supply ZERO Current SWITCHING ZERO Voltage SWITCHING
暂未订购
The Thermo-Hydraulic Analysis for Sub-Module of ITER HC-SB TBM Design
2
作者 ZHAO Zhou FENG Kaiming WANG Xiaoyu YUAN Tao CHEN Zhi 《Southwestern Institute of Physics Annual Report》 2005年第1期101-103,共3页
As the ITER (international thermonuclear experiment reactor ) project is being carried out further, original parties ( EU, JA, RF ) of ITER had accomplished their ITER TBM ( test blanket module ) design in 2001.... As the ITER (international thermonuclear experiment reactor ) project is being carried out further, original parties ( EU, JA, RF ) of ITER had accomplished their ITER TBM ( test blanket module ) design in 2001. China joined the negotiation of 1TER project and planed to develop own TBM modules in 2003. A preliminary design description document ( DDD ) for the CH HCSB ( chinese helium-cooled solid breeder ) TBM module design had been completed at SWIP in 2004. A modified structure design based on the 2004 version had been carried out subsequently. Main modification of structure design is that the sub-module design is adopted instead of the previous integrative module design. The modified design enforces the reliability and the flexibility of TBM module structure. The integral TBM module consists of 9 sub-modules. The thermo-hydraulic analysis for sub-module is very important, because the sub-module as a relative independent module has the most basic function of the test blanket module, such as depositing heat, producing tritium, etc. 展开更多
关键词 sub-module Thermo-hydraulic analysis Temperature distribution
在线阅读 下载PDF
Research on power electronic transformer applied in AC/DC hybrid distribution networks 被引量:15
3
作者 Yiqun Miao Jieying Song +6 位作者 Haijun Liu Zhengang Lu Shufan Chen Chun Ding Tianzhi Cao Linhai Cai Yuzhong Gong 《Global Energy Interconnection》 2018年第3期396-403,共8页
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D... The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation. 展开更多
关键词 AC/DC hybrid distribution network Power electronic transformer(PET) Clamping double sub-module(CDSM) Energy router
在线阅读 下载PDF
Power Supply of Macro-Micro Driven Linear Piezoelectric Motor
4
作者 Zhang Tiemin Liao Yiyong +2 位作者 Xu Zhilin Liang Li Cao Fei 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2017年第1期22-29,共8页
To investigate a novel macro and micro driven linear piezoelectric motor composed of an ultrasonic motor with macro movement and a piezoelectric actuator with micro movement,a digital signal processing(DSP)based macro... To investigate a novel macro and micro driven linear piezoelectric motor composed of an ultrasonic motor with macro movement and a piezoelectric actuator with micro movement,a digital signal processing(DSP)based macro and micro power supply is designed,which fits the new linear piezoelectric motor.The power supply comprises a control circuit,a voltage conversion circuit,an amplifier circuit,a half-bridge module,an optical isolatorsdrive circuit,etc,where the DSP of TMS320F28335 is used as the controller.When the linear piezoelectric motor working in a macro driven state,the power supply outputs alternating currents with high frequency and high voltage,which drives the linear piezoelectric motor dynamically at an ultrasonic frequency;while working in the micro driven state,the power supply outputs direct currents with high voltage,which drives the linear piezoelectric motor in micro driven statically.Here a prototype of the macro-micro power supply is designed.After a series of experiments on the power supply with and without loads,the results show that the power supply can drive and control the macro micro driven linear piezoelectric motor,and realizes quick and seamless switch between macro and micro drive.In addition,the power supply can drive and control the ultrasonic motor or piezoelectric ceramic micro actuator individually.The power supply achieves the multiple parameters of output signals adjustable simultaneously and exhibits good control characteristics. 展开更多
关键词 LINEAR piezoelectric motor macro-micro drive DSP half-bridge module
在线阅读 下载PDF
Simplified EMT Model of Multiple-active-bridge Based Power Electronic Transformer with Integrated Energy Storage
5
作者 Jianzhong Xu Conghui Zheng +3 位作者 Wanying Xu Moke Feng Chengyong Zhao Gen Li 《CSEE Journal of Power and Energy Systems》 2025年第3期1199-1210,共12页
Due to the advanced features of multidirectional power transfer and fast smoothing of the power fluctuation in renewable energy systems,the multiple-active-bridge based power-electronic-transformer(MAB-PET)with integr... Due to the advanced features of multidirectional power transfer and fast smoothing of the power fluctuation in renewable energy systems,the multiple-active-bridge based power-electronic-transformer(MAB-PET)with integrated energy storage units is becoming popular.However,the accurate electromagnetic transient simulation of the MAB-PETs is extremely time-consuming due to the large number of circuit nodes and small time-step.This paper proposes a simplified EMT modeling approach for the MAB-PETs by employing the generalized state-space averaging method.First,the switching function method and Dommel algorithm are used to build the equivalent model of each power module.Further,the PET equivalent model is presented in a multi-port PM polymerization mode.The system is simplified by applying Fourier Decomposition to its state functions by ignoring high-order harmonics.Finally,a four-port equivalent voltage source circuit is obtained.The proposed simplified equivalent model is compared with the detailed model in PSCAD/EMTDC.Simulation results show the proposed approach has excellent accuracy and is 2–3 orders of magnitude faster than the DM. 展开更多
关键词 Energy storage sub-module(ESS) generalized state average method multiple-active-bridge(MAB) simplified electromagnetic transient(EMT)simulation
原文传递
A modular multilevel power flow controller for meshed HVDC grids 被引量:5
6
作者 XU Feng XU Zheng 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第9期1773-1784,共12页
Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of me... Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of meshed HVDC grids with the PFC is presented,and then,the issue of over-voltage on the thyristor based PFC is described and analyzed.Through the analysis of different operating modes of the full-bridge sub-module,the mechanism of over-voltage ride through of the MMPFC is indicated.The control strategy of the MMPFC,which is used to control branch current and keep capacitor voltage balancing,is elaborated.Finally,the performance on current regulation,bidirectional operation and over-voltage ride through is simulated and verified in a built model with PSCAD/EMTDC. 展开更多
关键词 meshed HVDC grids multi-terminal HVDC modular multilevel power flow controller (MMPFC) bidirectional operation over-voltage ride through full-bridge sub-module
原文传递
Modular Reciprocating HVDC Circuit Breaker with Current-limiting and Bi-directional Series-parallel Branch Switching Capability 被引量:5
7
作者 Jianzhong Xu Moke Feng Chengyong Zhao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第4期778-786,共9页
The high-voltage direct current(HVDC)circuit breaker is becoming popular with the rapid development of the flexible HVDC grid for efficient DC fault ride-through purposes.This paper proposes a novel module for recipro... The high-voltage direct current(HVDC)circuit breaker is becoming popular with the rapid development of the flexible HVDC grid for efficient DC fault ride-through purposes.This paper proposes a novel module for reciprocating HVDC circuit breaker topology,whose branch connections are able to switch between series and parallel modes to limit the rising rate and interrupt the DC fault currents.Diode-bridge submodules(DBSMs)are used to compose the main branch for current interruption.Besides fault clearance,the proposed topology has the advantageous function of DC fault current limiting by employing DBSMs with bi-directional conduction capability.The topology can easily switch among branch connection modes through the assembled trans-valves,and their resistance and reactance are very small in the normal state when branches are in parallel and the values become promptly large in the transient state when the branches are series connected.With the modular design,it is easy to change the number of branches or sub-modules and the types of sub-modules to adapt to more specific needs.A 6-terminal modular multi-level converter(MMC)based HVDC grid is established in PSCAD/EMTDC,and various simulation scenarios are carried out to validate the proposed topology. 展开更多
关键词 Reciprocating current limiting direct current circuit breaker(DCCB) diode-bridge sub-module(DBSM) series and parallel branches DC fault clearance
原文传递
Novel Modular Multilevel Converter Against DC Faults for HVDC Applications 被引量:2
8
作者 Xiaofeng Yang Yao Xue +3 位作者 Bowei Chen Zhiqin Lin Trillion Q.Zheng Yan Li 《CSEE Journal of Power and Energy Systems》 SCIE 2017年第2期140-149,共10页
In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking su... In view of the DC fault current isolation deficiency for the conventional half-bridge sub-module(HBSM)based modular multilevel converter(MMC),this paper presents an improved MMC topology.Both quasi reverse blocking submodules(QRBSMs)and current limit modules(CLMs)are employed to improve the DC fault handling capability for HVDC applications.This paper analyzes such a new converter configuration and operation principles.Then the DC pole-to-pole short circuit fault is taken into consideration for further study,as well as the fault current blocking mechanism and quantitative relationship between system electrical stress and key parameters.To validate the feasibility of the proposed topology and fault protection theory,extensive simulation results are demonstrated.It is concluded that the QRB-MMC can effectively block the fault current under DC fault condition.In addition,CLMs play an important role in further accelerating fault current attenuation.Moreover,QRB-MMC employs the original control and modulation strategies under normal operation conditions;thus,it further reduces the complexity of industry design. 展开更多
关键词 Current limit module DC faults HVDC transmission modular multilevel converter quasi reverse blocking sub-module
原文传递
A DC Chopper Topology to Mitigate Commutation Failure of Line Commutated Converter Based High Voltage Direct Current Transmission 被引量:5
9
作者 Chunyi Guo Bo Liu Chengyong Zhao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第2期345-355,共11页
To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyri... To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyristor full-bridge module(TFB-PCSM)is proposed.Firstly,the mechanism of the proposed topology to mitigate CF is analyzed,and the working modes of TFB-PCSM in different operation states are introduced.Secondly,the coordinated control strategy between the proposed DC chopper and LCC-HVDC is designed,and the voltage-current stresses of the TFB-PCSMs are investigated.Finally,the ability to mitigate the CF issues and the fault recovery performance of LCC-HVDC system are studied in PSCAD/EMTDC.The results show that the probability of CF of LCC-HVDC is significantly reduced,and the performances of fault recovery are effectively improved by the proposed DC chopper. 展开更多
关键词 Line commutated converter based high-voltage direct current(LCC-HVDC)transmission DC chopper power consumption sub-module based on thyristor full-bridge module(TFB-PCSM) commutation failure(CF) fault recovery capability
原文传递
Research on a Multiport Parallel Type Hybrid Circuit Breaker for HVDC Grids:Modeling and Design
10
作者 Xinming Guo Jin Zhu +2 位作者 Qingpeng Zeng Hao Xiao Tongzhen Wei 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1732-1742,共11页
This paper proposes a star type multiport hybrid circuit breaker(Star-HCB)topology for protection of multiterminal DC transmission.Reliability and stability of high voltage DC(HVDC)grids are determined by their capabi... This paper proposes a star type multiport hybrid circuit breaker(Star-HCB)topology for protection of multiterminal DC transmission.Reliability and stability of high voltage DC(HVDC)grids are determined by their capabilities to withstand DC-side faults.In order to maintain reliability of HVDC grids,both ends of each line should be equipped with hybrid circuit breakers(HCB).This method will increase expenditure of the HVDC,especially the meshed topology.The n-port Star-HCB consists of ultra-fast mechanical disconnectors,load current switch and only one transferring branch which is formed by improved half-bridge sub-module.Compared with existing traditional hybrid circuit breakers and other multiport hybrid circuit breakers,the proposed topology can realize the same short-circuit blocking goal using fewer components.Detailed mathematical transient process calculation and timedomain simulation of the proposed Star-HCB are given to verify its superiority. 展开更多
关键词 Fault blocking HVDC grids half-bridge submodule hybrid circuit breaker MULTI-PORT
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部