期刊文献+
共找到2,278篇文章
< 1 2 114 >
每页显示 20 50 100
Application of Atomic Sparse Decomposition to Feature Extraction of the Fault Signal in Small Current Grounding System 被引量:1
1
作者 Nanhua Yu Rui Li +1 位作者 Jun Yang Bei Dong 《Energy and Power Engineering》 2013年第4期603-607,共5页
Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occu... Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness. 展开更多
关键词 Small Current grounding system Fault Line Selection ATOMIC SPARSE Decomposition Matching PURSUIT DAMPED SINUSOIDS
暂未订购
The Research of Voltage Sag and Power Frequency Overvoltage on 110kV Resistance Grounding System
2
作者 Guo Zeng Guangliang Feng +1 位作者 Yanping Lv Shan Sun 《Energy and Power Engineering》 2013年第4期873-876,共4页
This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence netwo... This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence network analysis of the -11 transformer, and concludes the scope of voltage sag and swell and the degree of power frequency overvoltage and their influencing factors in the 110 kV resistance grounding system. Accordingly this paper puts forward the resistance choosing principle: the resistance grounding coefficient must be equal to or greater than 10. So it can not only wipe out the voltage sag and voltage swell but also make sure the overvoltage is limited to electrical equipment allowing range. The method mentioned above is verified by simulation results of a 110 kV power system in ATP. 展开更多
关键词 NEUTRAL grounding system by RESISTANCE One-phase grounding FAULT Power Frequency OVERVOLTAGE
暂未订购
Analysis of a Large Grounding System and Subsequent Field Test Validation Using the Fall of Potential Method
3
作者 Huan Huang Hualin Liu +6 位作者 Hong Luo Hao Du Yi Xing Yexu Li Farid P. Dawalibi Haijun Zhou Longhai Fu 《Energy and Power Engineering》 2013年第4期1266-1272,共7页
This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interfer... This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interference can have a significant impact on the appropriate test location that yields the exact substation ground impedance. Applying a specific percentage rule such as the 61.8% rule for uniform soils to obtain the true ground impedance may lead to unacceptable errors for large grounding systems. This poses significant problems when attempting to validate a design based on raw test data that are interpreted using approximate methods to evaluate substation ground impedance, and determine ground potential rise (GPR), touch and step voltages. Advanced measurement methodologies and modern software packages were used to obtain and effectively analyze fall of potential test data, compute fault current distribution, and evaluate touch and step voltages for this large substation. Fault current distribution between the grounding system and other metallic paths were computed to determine the portion of fault current discharged in the grounding system. The performance of the grounding system, including its GPR and touch and step voltages, has been accurately computed and measured, taking into account the impedance of the steel material used of the ground conductors and circulating currents within the substation grounding system. 展开更多
关键词 GROUND Resistance Fall-of-Potential GROUND Impedance Measurement GROUND POTENTIAL RISE GROUND POTENTIAL Difference Touch VOLTAGE Step VOLTAGE Steel CONDUCTORS
暂未订购
Application of Fault Location Mode Based on Travelling Waves for Neutral Non-effective Grounding Systems
4
作者 Tao Ji Qian-qian Yuan +2 位作者 Chang-ming Li Ying Sun (Scientific Research Office Weifang University Weifang,China College of Information and Electrical EngineeringShandong University of Science and Technology Qingdao,China) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期133-138,共6页
Fault location for distribution feeders short circuit especially single-phase grounding fault is an important task in distribution system with non-effectively grounded neutral.Fault location mode for distribution feed... Fault location for distribution feeders short circuit especially single-phase grounding fault is an important task in distribution system with non-effectively grounded neutral.Fault location mode for distribution feeders using fault generated current and voltage transient traveling waves was investigated.The characteristics of transient traveling waves resulted from each short circuit fault and their transmission disciplinarian in distribution feeders are analyzed.This paper proposed that double end travelling waves theory which measures arriving time of fault initiated surge at both ends of the monitored line is fit for distribution feeders but single end traveling waves theory not.According to different distribution feeders,on the basis of analyzing original traveling waves reflection rule in line terminal, Current-voltage mode,voltage-voltage mode and current-current mode for fault location based on traveling waves are proposed and aerial mode component of original traveling waves is used to realize fault location.Experimental test verify the feasibility and correctness of the proposed method. 展开更多
关键词 distribution feeders neutral non-effective grounding traveling waves fault locationmode
在线阅读 下载PDF
Grounding Systems for Power Supply Facilities
5
作者 Vladimir Anatolevich Konusarov Evgeniy Alekseevich Shutov Tatyana Evgenievna Turukina 《Energy and Power Engineering》 2019年第1期1-14,共14页
The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition... The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition to pose a threat for health, the rise of the short circuit, as a consequence of insulation faults, poses a threat to retirement of electric systems and fire risks. The reliable grounding system design has significant implications for protection of human being as well as for electrical facility protection. The set objective was performed on the base of analytical and software-based methods. Analytical method gives a qualitative indication at each step in analysis. It also allows evaluating the values effect on the result, but the method is not susceptible of tolerable accuracy, that is why analytical method serves as initial approximation in differentiating. Specified estimation can be performed in such software package as MATLAB or ETAP. Software-based estimation is based on the finite element method (FEM), the main advantage of which is the ability to create different forms of grounding and allows obtaining distribution graphs of the step potential on the earth’s surface and touch potential. The calculation results in comparison of analytical and software-based methods taking into account the grounding optimization. There are conclusions on the most effective ground network. 展开更多
关键词 grounding Device Current-Using Equipment Short-Circuit FAULT Single Phase-to-Ground FAULT Main STEP Down Substation (MSDS) TN-C TN-S TN-C-S TT IT Indirect Contact STEP Potential FEM IEEE
暂未订购
Grounding Impedance Measurement of High Speed Railway Integrated Grounding System
6
作者 Zhang Yi Jianguo Wang +2 位作者 Yadong Fan Mi Zhou Li Cai 《Journal of Power and Energy Engineering》 2015年第4期194-199,共6页
The high-speed railway integrated grounding system is the basic guarantee for the safe and stable operation of the railway. It is the world’s largest long-distance horizontally elongated joint grounding system, which... The high-speed railway integrated grounding system is the basic guarantee for the safe and stable operation of the railway. It is the world’s largest long-distance horizontally elongated joint grounding system, which stretches the length of hundreds to thousands of kilometers, and its structure is not only different from power station and substation grounding system, but also different from the transmission line tower, lightning rod and other small grounding devices. There is little research information on the grounding impedance of high-speed railway integrated grounding system. This paper adopted 0.618 compensation method and reverse away method respectively, measured a section of high-speed railway integrated grounding system grounding impedance by JD16 and CA6425. Measurement results are in good agreement using those two type instrument. By using 0.618 compensation method, the measurement result will be gradually converged at 0.3 Ω with the increasing of current electrode distance, which is the real grounding impedance of integrated grounding system. By using reverse away method, the maximum measurement result difference is less than 0.024 Ω with the lead of current electrode distance increasing. The measurement results will be rapidly converged 0.25 Ω. The results showed that the reverse away method is helpful to shorten the length of current electrode wiring. The measurement error will be small when the current electrode wiring is longer. 展开更多
关键词 HIGH-SPEED RAILWAY INTEGRATED grounding system grounding IMPEDANCE
暂未订购
Computer Analysis of Electromagnetic Transients in Grounding Systems Considering Variation of Soil Parameters with Frequency
7
作者 Marco A.O.Schroeder Marcio M.Afonso +1 位作者 Tarcisio A.S.Oliveira Sandro C.Assis 《Journal of Electromagnetic Analysis and Applications》 2012年第12期475-480,共6页
This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obta... This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obtained by the application of the Moment Methods. A formulation based on experimental measurements is applied to quantify the soil parameters for each frequency. The unified approach is applied in the calculation of the grounding impedance of horizontal electrodes. Results show that the inclusion of frequency dependence of the soil parameters leads to a reduction of the values of grounding impedance, in comparison with results for soils with parameters independent of frequency. 展开更多
关键词 grounding Electrodes grounding Impedance Transient Response Frequency Response Electromagnetic Modeling
在线阅读 下载PDF
Enhancing grounding systems: effects of agro-based biochar used as backfill materials
8
作者 Jemima Akoto Solomon Nunoo James Ransford Dankwah 《Waste Disposal and Sustainable Energy》 2025年第3期495-507,共13页
Agro-waste biochar is gradually emerging as a greener and effective means of enhancing the effectiveness of grounding systems.Yet,only a few of such wastes have been empirically assessed as ground enhancing materials.... Agro-waste biochar is gradually emerging as a greener and effective means of enhancing the effectiveness of grounding systems.Yet,only a few of such wastes have been empirically assessed as ground enhancing materials.In this study,field-based soil resistivity and resistance to ground(RTG)value monitoring was used to assess the potential of biochar of coconut husk,sawdust,sugarcane bagasse,and rice husk as alternate ground enhancing materials vis-a-vis their susceptibility to seasonal variation and mode of application.The result of this study shows that the applied treatments exerted significant improvement(P-value≤0.05)in soil resistance and zone of influence values with the latter ranging less than 1 m for the clayey soil and equal of more than 2 m in the sandy soil.These effects of the study treatments were significantly influenced by time.A notable finding of this study is that rainfall and high moisture results in physical breakdown of biochar.This has significant implications for the use of treatment and the mode of application of treatment.Treatment,time,and mode of application of treatment played significant and interdependent role in reducing soil resistivity.These factors contributed to over 83%improvement of RTG values.This result suggests that though treatment,time and mode of application of treatment are major factors determining the effectiveness of ground enhancing materials,other confounding variables(e.g.method of carbonizing the waste,physical and chemical properties of the biochar)are also important determinants and must engender future research. 展开更多
关键词 grounding system Backfill material Soil resistivity Resistance to ground Agro-waste BIOCHAR
原文传递
Research on grounding protection system of the central solenoid model coil of the CRAFT
9
作者 Bei YE Ge GAO +2 位作者 Shusheng WANG Ya LI Qian JIANG 《Plasma Science and Technology》 2025年第4期81-87,共7页
This work presents a grounding protection system of the central solenoid model coil(CSMC)of the Comprehensive Research Facility for Fusion Technology(CRAFT).The scheme of neutral point voltage detections has been adop... This work presents a grounding protection system of the central solenoid model coil(CSMC)of the Comprehensive Research Facility for Fusion Technology(CRAFT).The scheme of neutral point voltage detections has been adopted in grounding protection system.Compared with the usual current acquisition,the measurement data is accurate,there is no redundant loop,and the economic benefit is high.In this study,the single-end and double-end grounding fault protections of superconducting magnet coil are analyzed,and the fault voltage and current under different fault conditions are calculated.The simulation model of CSMC magnet grounding fault is established,and the simulation results of the model are basically consistent with the theoretical calculation.Finally,a small capacity experiment platform is used to verify the function of the grounding protection system.The experimental results show that by comparing the neutral fault sampling voltage with the theoretical grounding protection threshold,the grounding protection system can effectively detect different types of grounding faults and transmit signals to the control system to protect the coils of superconducting magnets. 展开更多
关键词 single-end grounding double-end grounding grounding resistance fault voltage fast discharge unit(Some figures may appear in colour only in the online journal)
在线阅读 下载PDF
Faulty Feeder Identification and Fault Area Localization in Resonant Grounding System Based on Wavelet Packet and Bayesian Classifier 被引量:8
10
作者 Jingwen Chen Enliang Chu +3 位作者 Yingchun Li Baoji Yun Hongshe Dang Yali Yang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第4期760-767,共8页
Accurate fault area localization is a challenging problem in resonant grounding systems(RGSs).Accordingly,this paper proposes a novel two-stage localization method for single-phase earth faults in RGSs.Firstly,a fault... Accurate fault area localization is a challenging problem in resonant grounding systems(RGSs).Accordingly,this paper proposes a novel two-stage localization method for single-phase earth faults in RGSs.Firstly,a faulty feeder identification algorithm based on a Bayesian classifier is proposed.Three characteristic parameters of the RGS(the energy ratio,impedance factor,and energy spectrum entropy)are calculated based on the zero-sequence current(ZSC)of each feeder using wavelet packet transformations.Then,the values of three parameters are sent to a pre-trained Bayesian classifier to recognize the exact fault mode.With this result,the faulty feeder can be finally identified.To find the exact fault area on the faulty feeder,a localization method based on the similarity comparison of dominant frequency-band waveforms is proposed in an RGS equipped with feeder terminal units(FTUs).The FTUs can provide the information on the ZSC at their locations.Through wavelet-packet transformation,ZSC dominant frequency-band waveforms can be obtained at all FTU points.Similarities of the waveforms of characteristics at all FTU points are calculated and compared.The neighboring FTU points with the maximum diversity are the faulty sections finally determined.The proposed method exhibits higher accuracy in both faulty feeder identification and fault area localization compared to the previous methods.Finally,the effectiveness of the proposed method is validated by comparing simulation and experimental results. 展开更多
关键词 Resonant grounding system single-phase earth fault faulty feeder identification fault area localization wavelet packet Bayesian classifier
原文传递
Calculating the transient behavior of grounding systems using inverse Laplace transform 被引量:3
11
作者 Nabiollah RAMEZANI Seyed Mohammad SHAHRTASH 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2011年第3期250-262,共13页
This paper deals with a unified and novel approach for analyzing the frequency and time domain performance of grounding systems.The proposed procedure is based on solving the full set of Maxwell's equations in the... This paper deals with a unified and novel approach for analyzing the frequency and time domain performance of grounding systems.The proposed procedure is based on solving the full set of Maxwell's equations in the frequency domain,and enables the exact computation of very near fields at the surface of the grounding grid,as well as far fields,by simple and accurate closed-form expressions for solving Sommerfeld integrals.In addition,the soil ionization is easily considered in the proposed method.The frequency domain responses are converted to the time domain by fast inverse Laplace transform.The results are validated and have shown acceptable accuracy. 展开更多
关键词 Electromagnetic field Near-field computation High frequency performance Soil ionization grounding system Fast inverse Laplace transform
原文传递
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
12
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL grounding system by Resistance One-phase grounding Fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTION Setting
暂未订购
Grounding Locations Assessment of Practical Power System
13
作者 Nadheer A. Shalash Ahmed M. A. Haidar Kousay Abdul Sattar 《Energy and Power Engineering》 2012年第1期19-27,共9页
Grounding Points (GPs) are installed in electrical power system to drive protective devices and accomplish the person nel safety. The general grounding problem is to find the optimal locations of these points so that ... Grounding Points (GPs) are installed in electrical power system to drive protective devices and accomplish the person nel safety. The general grounding problem is to find the optimal locations of these points so that the security and reli ability of power system can be improved. This paper presents a practical approach to find the optimal location of GPs based on the ratios of zero sequence reactance with positive sequence reactance (X0/X1), zero sequence resistance with positive sequence reactance (R0/X1) and Ground Fault Factor (GFF). The optimal values of these indicators were deter-mined by considering several scenarios of fault disturbances such as single line to ground on a selected area of the Iraqi National Grid (132 KV) taking into account the statue of GPs for transformers in the other substations. From the presented results in this paper, it is noted that GFF calculated for some substations could be used to measure the effectiveness of GPs. However, the operated time of relay can be taken as a criterion of this measurement for selecting the best location of GPs. 展开更多
关键词 grounding Point FAULT Factor National Grid Optimal LOCATION Operating Time FAULT Calculation
暂未订购
Research on Grounding of Shore-to-Ship Power Supply System
14
作者 Ningzhao Luo Hongjiang Li Haolan Zhang 《Journal of Power and Energy Engineering》 2014年第4期612-615,共4页
To avoid pollution of generator exhaust port after the ship docked, the use of shore power supply is developing direction of port. And the shore power grounding method and related standards needed to be carried out. A... To avoid pollution of generator exhaust port after the ship docked, the use of shore power supply is developing direction of port. And the shore power grounding method and related standards needed to be carried out. According to developing status of foreign medium voltage ship and characteristics of navy shipboard power supply, this paper presents a shore power supply network structure and its grounding method. The simulation results show the power supply network structure can effectively suppress the single-phase intermittent ground fault on the system to produce the harm. 展开更多
关键词 Medium Voltage grounding SHIPBOARD COLD IRONING
在线阅读 下载PDF
Triple One Wire System without Grounding
15
作者 Michael Bank Vladimir Tsingaouz 《Engineering(科研)》 2023年第12期867-870,共4页
Today the entire globe is shrouded in an inefficient three-phase system. There is however an efficient single-wire system. To use the single wire method, three phase systems can be converted to triple one wire systems.
关键词 Three-Phase One-Wire system ZEROING grounding Nullifier
在线阅读 下载PDF
Capacity matching and optimization of solarground source heat pump coupling systems 被引量:1
16
作者 Jing-hui Luo Yun-xin Huang +4 位作者 Jing-gang Wang Wei Liu Wen-hong Wang Zi-chen Han Chang-jian Zhang 《Applied Geophysics》 2025年第3期739-750,895,共13页
Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,i... Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,in certain regions,the installation of buried pipes for heat exchangers may be complicated,and these pipes may not always serve as efficient low-temperature heat sources for the heat pumps of the system.To address this issue,the current study explored the use of solar-energy-collecting equipment to supplement buried pipes.In this design,both solar energy and geothermal energy provide low-temperature heat to the heat pump.First,a simulation model of a solar‒ground source heat pump coupling system was established using TRNSYS.The accuracy of this model was validated through experiments and simulations on various system configurations,including varying numbers of buried pipes,different areas of solar collectors,and varying volumes of water tanks.The simulations examined the coupling characteristics of these components and their influence on system performance.The results revealed that the operating parameters of the system remained consistent across the following configurations:three buried pipes,burial depth of 20 m,collector area of 6 m^(2),and water tank volume of 0.5 m^(3);four buried pipes,burial depth of 20 m,collector area of 3 m^(2),and water tank volume of 0.5 m^(3);and five buried pipes with a burial depth of 20 m.Furthermore,the heat collection capacity of the solar collectors spanning an area of 3 m^(2)was found to be equivalent to that of one buried pipe.Moreover,the findings revealed that the solar‒ground source heat pump coupling system demonstrated a lower annual cumulative energy consumption compared to the ground source heat pump system,presenting a reduction of 5.31%compared to the energy consumption of the latter. 展开更多
关键词 solar‒ground source heat pump coupling system OPTIMIZATION TRNSYS energy-saving operation matching design
在线阅读 下载PDF
Discussion on Grounding Mode of Low Voltage Power Supply and Distribution System
17
作者 BAI Kaifan 《外文科技期刊数据库(文摘版)工程技术》 2021年第3期181-183,共3页
With the development of society, China's economy is growing rapidly. With the gradual improvement of people's living standards, electricity has become an indispensable part of our lives, affecting people's... With the development of society, China's economy is growing rapidly. With the gradual improvement of people's living standards, electricity has become an indispensable part of our lives, affecting people's lives and the development of the national economy all the time. 展开更多
关键词 low voltage power supply and distribution system MORTGAGE grounding mode RESEARCH APPLICATION
原文传递
Mathematical Modelling for Assessing Integrity of Power Systems Grounding Devices
18
作者 Yury Chikarov Tek Tjing Lie Nirmal-Kumar Nair 《Journal of Energy and Power Engineering》 2012年第7期1097-1105,共9页
This paper presents the development of a new technique to monitor the operating conditions of a grounding device of high voltage apparatus and systems without any diggings and forced outages. The model is based on the... This paper presents the development of a new technique to monitor the operating conditions of a grounding device of high voltage apparatus and systems without any diggings and forced outages. The model is based on the evaluation of the magnetic field distribution along the current-carrying horizontal element when it has been deteriorated or broken. A mathematical model which can be used to analyze and evaluate the integrity of the grounding device has been developed. Computer simulation studies were conducted to validate the effectiveness of the proposed model. 展开更多
关键词 grounding devices horizontal elements eat'thing.
在线阅读 下载PDF
Path Individuation and Retrospective Grounding
19
作者 ZHENG Yujian 《自然辩证法通讯》 北大核心 2025年第12期37-51,共15页
This paper purports to expound a special(technical)notion of paths.A neglected fundamental fact(especially under indeterminism)is that the path-dependent direction of any diachronic outcome is backward,i.e.,later step... This paper purports to expound a special(technical)notion of paths.A neglected fundamental fact(especially under indeterminism)is that the path-dependent direction of any diachronic outcome is backward,i.e.,later steps depend on earlier ones successively,despite the ineradicable chance in their respective formation.In this paper,a token-oriented retrospective approach is proposed to overcome the limitation of the type-oriented approach in explaining path-related phenomena.My argument for the validity and utility of this approach is largely based on the elements of(PD),a definitional schema for diachronic sequences subject to a recursive counterfactual formula.I explore certain aspects of path individuation that have so far not been discussed,despite(PD)’s formal congeniality with Lewis’s‘causal chain’.Two basic patterns of path generation are examined:the first is for distinguishing actual vs possible branching paths,while the second introduces a metaphysical theme regarding the retrospective grounding of the causal status of an upstream event by its downstream(joint)effect.A central example of the paper,viz.,the Gobang game,is used to illustrate how the token-oriented approach works for path individuation. 展开更多
关键词 Path individuation Retrospective grounding Token-oriented approach Path dependence Diachronic difference making
原文传递
Influence of grounding giant iceberg D15 on sea ice and polynyas in a sea ice-ice shelf-ocean numerical model of the Prydz Bay,Antarctica
20
作者 Quanyi Zhou Jiuxin Shi +5 位作者 Chuning Wang Longjiang Mu Zhigang Yao Zhaoru Zhang Yuxin Han Yongming Sun 《Acta Oceanologica Sinica》 2025年第3期147-160,共14页
A three-dimensional coupled sea ice-ice shelf-ocean numerical model is developed for the Prydz Bay,Antarctica,using the Regional Ocean Modeling System with a grid resolution of approximately 2 km.The influence of the ... A three-dimensional coupled sea ice-ice shelf-ocean numerical model is developed for the Prydz Bay,Antarctica,using the Regional Ocean Modeling System with a grid resolution of approximately 2 km.The influence of the grounding giant iceberg D15 on the distribution of sea ice and polynyas in the Prydz Bay is analyzed through two numerical experiments.Iceberg D15,grounded off the western edge of the West Ice Shelf(WIS),obstructs the southwestward transport of sea ice along the east coast of Prydz Bay,causing sea ice to accumulate to the east of the iceberg and form multi-year fast ice.Grounding of Iceberg D15 also decreases sea ice coverage off its south edge and creates ice-free openings in spring near Davis Station and Zhongshan Station,facilitating the accessibility of vessels to the research stations.These simulated sea ice patterns closely match current satellite observations.When Iceberg D15 is removed,the previously blocked sea ice north of the iceberg,which moved westward,shifts southwesterly along the coastline,leading to a reduction in sea ice thickness during winter and spring,as well as lower sea ice concentrations in spring across large areas north and west of the iceberg.In contrast,the sea ice thickness increases considerably southwest of the WIS,extending to the front of the Amery Ice Shelf during seasons covered by sea ice.The increase in sea ice concentration can also extend to as far as 75°E in spring.Without Iceberg D15,which previously contributed to the ice barrier of Barrier Polynya(BP),the shape of BP changes,the area of BP and Davis Polynya(DP)decreases,and the polynya off the northwest edge of the WIS near 83°E expands.These polynya patterns are much similar to the satellite remote sensing observations before Iceberg D15 was grounded.From April to October,the total area of BP and DP decreases by 2.83×10^(4)km^(2)(60%)and 2.20×10^(3)km^(2)(20%),respectively,while the total sea ice production decreases by 4.11×10^(10)m^(3)(66%)and 1.52×10^(10)m^(3)(52%)compared to the experiment with iceberg.These results indicate the substantial effects of grounding giant icebergs on the spatio-temporal distribution of sea ice,the area of polynyas,and sea ice production.High-resolution Antarctic coastal numerical models,typically with grid scales of kilometers,are sufficient to represent large icebergs,and adding the grounding giant icebergs is crucial for producing realistic simulations of sea ice and polynyas. 展开更多
关键词 grounding iceberg sea ice POLYNYA numerical simulation Prydz Bay ANTARCTICA
在线阅读 下载PDF
上一页 1 2 114 下一页 到第
使用帮助 返回顶部