期刊文献+
共找到2,254篇文章
< 1 2 113 >
每页显示 20 50 100
Research on grounding protection system of the central solenoid model coil of the CRAFT
1
作者 Bei YE Ge GAO +2 位作者 Shusheng WANG Ya LI Qian JIANG 《Plasma Science and Technology》 2025年第4期81-87,共7页
This work presents a grounding protection system of the central solenoid model coil(CSMC)of the Comprehensive Research Facility for Fusion Technology(CRAFT).The scheme of neutral point voltage detections has been adop... This work presents a grounding protection system of the central solenoid model coil(CSMC)of the Comprehensive Research Facility for Fusion Technology(CRAFT).The scheme of neutral point voltage detections has been adopted in grounding protection system.Compared with the usual current acquisition,the measurement data is accurate,there is no redundant loop,and the economic benefit is high.In this study,the single-end and double-end grounding fault protections of superconducting magnet coil are analyzed,and the fault voltage and current under different fault conditions are calculated.The simulation model of CSMC magnet grounding fault is established,and the simulation results of the model are basically consistent with the theoretical calculation.Finally,a small capacity experiment platform is used to verify the function of the grounding protection system.The experimental results show that by comparing the neutral fault sampling voltage with the theoretical grounding protection threshold,the grounding protection system can effectively detect different types of grounding faults and transmit signals to the control system to protect the coils of superconducting magnets. 展开更多
关键词 single-end grounding double-end grounding grounding resistance fault voltage fast discharge unit(Some figures may appear in colour only in the online journal)
在线阅读 下载PDF
Influence of grounding giant iceberg D15 on sea ice and polynyas in a sea ice-ice shelf-ocean numerical model of the Prydz Bay,Antarctica
2
作者 Quanyi Zhou Jiuxin Shi +5 位作者 Chuning Wang Longjiang Mu Zhigang Yao Zhaoru Zhang Yuxin Han Yongming Sun 《Acta Oceanologica Sinica》 2025年第3期147-160,共14页
A three-dimensional coupled sea ice-ice shelf-ocean numerical model is developed for the Prydz Bay,Antarctica,using the Regional Ocean Modeling System with a grid resolution of approximately 2 km.The influence of the ... A three-dimensional coupled sea ice-ice shelf-ocean numerical model is developed for the Prydz Bay,Antarctica,using the Regional Ocean Modeling System with a grid resolution of approximately 2 km.The influence of the grounding giant iceberg D15 on the distribution of sea ice and polynyas in the Prydz Bay is analyzed through two numerical experiments.Iceberg D15,grounded off the western edge of the West Ice Shelf(WIS),obstructs the southwestward transport of sea ice along the east coast of Prydz Bay,causing sea ice to accumulate to the east of the iceberg and form multi-year fast ice.Grounding of Iceberg D15 also decreases sea ice coverage off its south edge and creates ice-free openings in spring near Davis Station and Zhongshan Station,facilitating the accessibility of vessels to the research stations.These simulated sea ice patterns closely match current satellite observations.When Iceberg D15 is removed,the previously blocked sea ice north of the iceberg,which moved westward,shifts southwesterly along the coastline,leading to a reduction in sea ice thickness during winter and spring,as well as lower sea ice concentrations in spring across large areas north and west of the iceberg.In contrast,the sea ice thickness increases considerably southwest of the WIS,extending to the front of the Amery Ice Shelf during seasons covered by sea ice.The increase in sea ice concentration can also extend to as far as 75°E in spring.Without Iceberg D15,which previously contributed to the ice barrier of Barrier Polynya(BP),the shape of BP changes,the area of BP and Davis Polynya(DP)decreases,and the polynya off the northwest edge of the WIS near 83°E expands.These polynya patterns are much similar to the satellite remote sensing observations before Iceberg D15 was grounded.From April to October,the total area of BP and DP decreases by 2.83×10^(4)km^(2)(60%)and 2.20×10^(3)km^(2)(20%),respectively,while the total sea ice production decreases by 4.11×10^(10)m^(3)(66%)and 1.52×10^(10)m^(3)(52%)compared to the experiment with iceberg.These results indicate the substantial effects of grounding giant icebergs on the spatio-temporal distribution of sea ice,the area of polynyas,and sea ice production.High-resolution Antarctic coastal numerical models,typically with grid scales of kilometers,are sufficient to represent large icebergs,and adding the grounding giant icebergs is crucial for producing realistic simulations of sea ice and polynyas. 展开更多
关键词 grounding iceberg sea ice POLYNYA numerical simulation Prydz Bay ANTARCTICA
在线阅读 下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
3
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault grounding protection Zero-sequence current ratio coefficient
在线阅读 下载PDF
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
4
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
在线阅读 下载PDF
Computer Analysis of Electromagnetic Transients in Grounding Systems Considering Variation of Soil Parameters with Frequency
5
作者 Marco A.O.Schroeder Marcio M.Afonso +1 位作者 Tarcisio A.S.Oliveira Sandro C.Assis 《Journal of Electromagnetic Analysis and Applications》 2012年第12期475-480,共6页
This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obta... This paper presents a mathematical model to calculate transients in grounding systems. The derived equations arise from direct application of basic electromagnetic equations in frequency domain, whose solution is obtained by the application of the Moment Methods. A formulation based on experimental measurements is applied to quantify the soil parameters for each frequency. The unified approach is applied in the calculation of the grounding impedance of horizontal electrodes. Results show that the inclusion of frequency dependence of the soil parameters leads to a reduction of the values of grounding impedance, in comparison with results for soils with parameters independent of frequency. 展开更多
关键词 grounding Electrodes grounding Impedance Transient Response Frequency Response Electromagnetic Modeling
在线阅读 下载PDF
An Improved Algorithm of Grounding Grids Corrosion Diagnosis Based on Total Least Square Method 被引量:3
6
作者 ZHANG Ying-jiao NIU Tao WANG Sen 《高压电器》 CAS CSCD 北大核心 2011年第5期22-29,共8页
A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposit... A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposition is adopted to improve the effectiveness of grounding grids' diagnosis algorithm.The improvement can weaken the influence of the model's error,which results from the differences between design paper and actual grid.Its influence on touch and step voltages caused by the interior resistance of conductors is taken into account.Simulation results show the validity of this approach. 展开更多
关键词 corrosion property grounding grids corrosion diagnosis AMBIGUOUS total least square touch and step voltages
在线阅读 下载PDF
Corrosion behavior of low-carbon Cr micro-alloyed steel for grounding grids in simulated acidic soil 被引量:3
7
作者 Jian Li Hang Su +4 位作者 Feng Chai Dong-mei Xue Li Li Xiang-yang Li Hui-min Meng 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2018年第7期755-766,共12页
To improve the corrosion resistance of steels for grounding grids, a low-carbon Cr micro-alloyed steel was developed (C 1 steel), and corrosion behavior of Q235 steel and newly developed C1 steel in simulated acidic... To improve the corrosion resistance of steels for grounding grids, a low-carbon Cr micro-alloyed steel was developed (C 1 steel), and corrosion behavior of Q235 steel and newly developed C1 steel in simulated acidic soil was investigated. The corrosion rate was evaluated with the mass loss measurements, while the corrosion morphology of surface and cross section of rust layer was observed by scanning electron microscopy. The corrosion products were analyzed by energy- dispersive X-ray spectrometry, X-ray diffraction and X-ray photoelectron spectroscopy, and the polarization curve was measured using potentiodynamic polarization method. Results indicated that C 1 steel displayed good corrosion resistance in the simulated acidic soil, of which the corrosion rate was only 30% of that of Q235 steel after corrosion for 360 h. The analysis of rust layer showed that lower carbon content in steel could reduce the tendency of micro cell corrosion and appropriate amount of chromium could improve the corrosion potential of metal matrix. Moreover, the analysis of X-ray photoelectron spectroscopy revealed that the chromium enriched in inner rust layer of C1 steel existed mainly in the form of Fe2CrO4, which facilitated the formation of Cr-goethite and improved the protection of corrosion products. 展开更多
关键词 Soil corrosion grounding grid Low-carbon steel Cr micro-alloying Corrosion product - Cr-goethite
原文传递
Determination of grounding line on the Amery Ice Shelf using Sentinel-1 radar interferometry data 被引量:2
8
作者 LEI Haobo ZHOU Chunxia CHEN Yiming 《Advances in Polar Science》 2017年第3期204-213,共10页
Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation da... Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation data to map the GL of the Amery Ice Shelf(AIS) using double-differential synthetic aperture radar interferometry. The ice thickness anomaly deduced from hydrostatic equilibrium and existing Antarctic GL products is compared with our result. With this new and very accurate GL, we detected new ice rises in the north of the AIS. Our new measurement shows no major change of the AIS GL, particularly in the southernmost part. 展开更多
关键词 grounding line DDInSAR hydrostatic equilibrium Amery Ice Shelf
在线阅读 下载PDF
Structural Reliability Analysis of Ship Hulls Accounting for Collision or Grounding Damage 被引量:1
9
作者 Branka BužančićPrimorac Joško Parunov C.Guedes Soares 《Journal of Marine Science and Application》 CSCD 2020年第4期717-733,共17页
Classical structural reliability analysis of intact ship hulls is extended to the case of ships with collision or grounding damages.Still water load distribution and residual bending moment capacity are included as ra... Classical structural reliability analysis of intact ship hulls is extended to the case of ships with collision or grounding damages.Still water load distribution and residual bending moment capacity are included as random variables in the limit state equation.The probability density functions of these random variables are defined based on random damage parameters given by the Marine Environment Protection Committee of the International Maritime Organization,while the proposed reliability formulation is consistent with international recommendations and thus may be valuable in the development of rules for accidental limit states.The methodology is applied on an example of an Aframax oil tanker.The proposed approach captures in a rational way complex interaction of different pertinent variables influencing safety of damaged ship structure. 展开更多
关键词 Ship structures Hull girder Collision and grounding Damaged oil tanker Residual strength Uncertainty modelling Structural reliability
在线阅读 下载PDF
Study on Decision Method of Neutral Point Grounding Mode for Medium-Voltage Distribution Network 被引量:2
10
作者 Hengyong Liu Xiaofu Xiong +3 位作者 Jinxin Ouyang Xiufen Gong Yinghua Xie Jing Li 《Journal of Power and Energy Engineering》 2014年第4期656-664,共9页
The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and e... The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method. 展开更多
关键词 Distribution Network NEUTRAL grounding MODE RELIABILITY DECISION Method Objective FUNCTION
暂未订购
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
11
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
在线阅读 下载PDF
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
12
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL grounding System by Resistance One-phase grounding Fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTION Setting
暂未订购
Numerical simulation of the dynamic effects of grounding icebergs on summer circulation in Prydz Bay,Antarctica 被引量:1
13
作者 HAN Yuxin SHI Jiuxin +1 位作者 HOU Saisai XIAO Changhao 《Advances in Polar Science》 CSCD 2022年第2期135-144,共10页
The Regional Ocean Modeling System(ROMS)is employed to create a three-dimensional numerical model of the summer circulation in the Prydz Bay region,Antarctica.Consistent with the currents measured using an underway ac... The Regional Ocean Modeling System(ROMS)is employed to create a three-dimensional numerical model of the summer circulation in the Prydz Bay region,Antarctica.Consistent with the currents measured using an underway acoustic Doppler current profiler during a Chinese cruise,the simulated current field illustrates the major features of the Prydz Bay circulation,including the Antarctic Slope Current(ASC)along the continental shelf break,the cyclonic Prydz Bay Gyre,and the Prydz Bay Eastern Coastal Current(PBECC).The effects of grounding icebergs D15 and B15 on the circulation in Prydz Bay are investigated via numerical simulations.The results indicate that these giant grounding icebergs substantially affect the flows into and within the bay,which may differ with the different grounding locations.As grounding iceberg D15 is located close to the southwestern part of the West Ice Shelf(WIS),it cuts off the coastal current along the outer edge of the WIS,and the ASC can only enter Prydz Bay from the west side of iceberg D15,whereupon it becomes a main source of the PBECC.Iceberg D15 also weakens the circulation in the bay in general.The relatively small iceberg B15 entered Prydz Bay from 2007 to 2009 and grounded on the southwestern section of the Four Ladies Bank.The numerical experiments indicate that iceberg B15 guides the ASC flowing into the bay around its west side and reduces the width of the inflow on the eastern side of the Prydz Bay Channel.The grounding of iceberg B15 has also led to adjustments of the circulation within the bay,among which the most significant is that the outflow along the western flank of Fram Bank has shifted to the west and become more intensive. 展开更多
关键词 CIRCULATION grounding iceberg numerical simulation Prydz Bay ANTARCTICA
在线阅读 下载PDF
An Investigation into Substation Grounding and Its Implementation on Gaza Substation 被引量:1
14
作者 Ahmed Hammuda Hassan Nouri Mohammed Saleh Al-Ayoubi 《Energy and Power Engineering》 2011年第5期593-599,共7页
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiven... An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study. Through modelling and simulating the power station in Gaza while considering some field data, an optimal substation grounding grid has been designed and has shown complete conformance to safety. It is thus considered that such a design will protect personnel in any area of the substation in addition to the installed machinery if the largest possible fault current was to traverse the earth. 展开更多
关键词 GAZA grounding Grid Ground Resistance SUBSTATION STEP VOLTAGE TOUCH VOLTAGE
暂未订购
Application of Atomic Sparse Decomposition to Feature Extraction of the Fault Signal in Small Current Grounding System 被引量:1
15
作者 Nanhua Yu Rui Li +1 位作者 Jun Yang Bei Dong 《Energy and Power Engineering》 2013年第4期603-607,共5页
Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occu... Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness. 展开更多
关键词 Small Current grounding System Fault Line Selection ATOMIC SPARSE Decomposition Matching PURSUIT DAMPED SINUSOIDS
暂未订购
Research on Magnetically Coupled Resonant Detection Method for Breakpoint of Four Mesh Grounding Grid 被引量:2
16
作者 Weihua Chen Shuai Wang +1 位作者 Xiaoheng Yan Zhiquan Ye 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期218-228,共11页
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this pape... Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid.But the method can only detect breakpoints of a single mesh grounding grid at present.In this paper,a magnetically coupled resonant detection method for four-hole grounding grid breakpoint is proposed.Firstly,the equivalent circuit model of the four mesh grounding grid with two types of breakpoints,namely edge branch and intermediate branch,is established.The input impedance and phase angle of the system are obtained by analyzing the equivalent capacitance and equivalent resistance in the model.Secondly,the magnetically coupled resonant physical process of grounding grid faults is solved via HFSS software.The magnetic field intensity and phase frequency characteristic curves of four mesh holes with different branches and positions of breakpoints and different corrosion degrees are studied,and an experimental system is built to verify the feasibility.The results show that under the condition of grounding grid buried depth of 0.5 m and input frequency of 1~15MHz,and there is an inverse relationship between equivalent capacitance and distortion frequency,the phase angle is positively correlated with the degree of corrosion of grounding grid,and the error of signal distortion frequency can be positioned at 5%.This paper provides some ideas for the application of magnetic coupling grounding grid detection technology. 展开更多
关键词 grounding grid Magnetically coupled resonant detection Input impedance Phase frequency characteristic curve
在线阅读 下载PDF
The Research on Neutral Grounding Scheme of Fengxian 35kV and 10 kV Power Grid 被引量:1
17
作者 Siming Hua Hua Zhang +2 位作者 Feng Qian Chunjie Chen Meixia Zhang 《Energy and Power Engineering》 2013年第4期897-901,共5页
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur... Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current. 展开更多
关键词 NEUTRAL grounding Mode Different Frequency Injected Method Capacitive Current ARC SUPPRESSION COIL Low Resistance
暂未订购
Study on Earth Surface Potential and DC Current Distribution around DC Grounding Electrode 被引量:1
18
作者 Zhi-chao Ren Chun-yan Ye Hai-yan Wang 《Energy and Power Engineering》 2013年第4期792-796,共5页
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche... DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results. 展开更多
关键词 DC grounding ELECTRODE Magnetic BIASING Soil STRATIFICATION Earth Surface Potential DC Current DISTRIBUTION
暂未订购
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
19
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation grounding current detection Zero sequence voltage detection
在线阅读 下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
20
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
在线阅读 下载PDF
上一页 1 2 113 下一页 到第
使用帮助 返回顶部