Application of Fault Location Mode Based on Travelling Waves for Neutral Non-effective Grounding Systems
1
作者 Tao Ji Qian-qian Yuan +2 位作者 Chang-ming Li Ying Sun (Scientific Research Office Weifang University Weifang,China College of Information and Electrical EngineeringShandong University of Science and Technology Qingdao,China) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期133-138,共6页
Fault location for distribution feeders short circuit especially single-phase grounding fault is an important task in distribution system with non-effectively grounded neutral.Fault location mode for distribution feed... Fault location for distribution feeders short circuit especially single-phase grounding fault is an important task in distribution system with non-effectively grounded neutral.Fault location mode for distribution feeders using fault generated current and voltage transient traveling waves was investigated.The characteristics of transient traveling waves resulted from each short circuit fault and their transmission disciplinarian in distribution feeders are analyzed.This paper proposed that double end travelling waves theory which measures arriving time of fault initiated surge at both ends of the monitored line is fit for distribution feeders but single end traveling waves theory not.According to different distribution feeders,on the basis of analyzing original traveling waves reflection rule in line terminal, Current-voltage mode,voltage-voltage mode and current-current mode for fault location based on traveling waves are proposed and aerial mode component of original traveling waves is used to realize fault location.Experimental test verify the feasibility and correctness of the proposed method. 展开更多
关键词 distribution feeders neutral non-effective grounding traveling waves fault locationmode
在线阅读 下载PDF
塑造自然生态景观型的交通站区——无锡轨道交通1号线胜利门站地区城市设计 被引量:3
2
作者 卢济威 杨春侠 《上海城市规划》 2015年第4期97-100,112,共5页
随着许多大中城市建设轨道交通,地铁站点及其周边地区的发展将成为重要的课题。无锡轨道交通1号线胜利门站地区面临着如何振兴区域活力与如何充分利用孤岛绿地等两大问题,城市设计抓住地铁发展机遇,针对环境现状,运用"消费行为系列... 随着许多大中城市建设轨道交通,地铁站点及其周边地区的发展将成为重要的课题。无锡轨道交通1号线胜利门站地区面临着如何振兴区域活力与如何充分利用孤岛绿地等两大问题,城市设计抓住地铁发展机遇,针对环境现状,运用"消费行为系列化""、公共交通为导向开发""、充分发展地下空间""、地下地上一体化"等理念,制定相关设计策略。通过城市设计对地铁站点与周边地区的整合,振兴了地区的活力,也把原有孤岛绿地发展为自然生态景观型的交通站区。目前,城市设计正在得到实施。 展开更多
关键词 消费行为系列化 交通枢纽地区体系化 地下地上一体化 自然生态景观
在线阅读 下载PDF
Field experiment using transient energy method to locate a single-phase to ground fault 被引量:1
3
作者 Wei Xie Xuewen Wang +4 位作者 Chen Fang Hengxu Zhang Fang Shi Xiaodong Xing Baicong Sun 《Global Energy Interconnection》 CAS 2020年第6期585-594,共10页
Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults... Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems(NIGSs),and more than 80%of the faults in distribution networks are single-phase-to-ground(SPG)faults.Because of the weak fault current and imperfect monitoring equipment configurations,methods used to determine the faulty line secti ons with SPG faults in NIGSs are in effective.The developme nt and application of distributi on-level phasor measurement units(PMUs)provide further comprehensive fault information for fault diagnosis in a distribution network.When an SPG fault occurs,the transient energy of the faulted line section tends to be higher than the sum of the transient energies of other line sections.In this regard,transient energy-based fault location algorithms appear to be a promising resolution.In this study,a field test plan was designed and implemented for a 10 kV distribution network.The test results dem on strate the effective ness of the transient en ergy-based SPG locati on method in practical distributi on networks. 展开更多
关键词 Sin gle-phase-to-gro und fault Fault location Neutral in efficiently groundi ng systems Distributi on n etwork Distribution-level PMU Transient energy.
在线阅读 下载PDF
新型接地材料在高土壤电阻率电气工程中的应用 被引量:1
4
作者 成健 王广华 徐爱生 《山西电力》 2007年第3期44-45,共2页
为了确保各种环境条件下,包括土壤电阻率较高的变电站接地网接地电阻满足规范要求,以一种新型非金属接地模块替代化学降阻剂在变电站建设中得以实施,并收到了良好的效果。
关键词 接地电阻 土壤电阻率 化学降阻剂 接地模块
在线阅读 下载PDF