期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Performance Boundaries of Air-and Ground-Coupled GPR for Void Detection in Multilayer Reinforced HSR Tunnel Linings:Simulation and Field Validation
1
作者 Yang Lei Bo Jiang +5 位作者 Yucai Zhao Gaofeng Fu Falin Qi Tian Tian Qiankuan Feng Qiming Qu 《Structural Durability & Health Monitoring》 2025年第6期1657-1679,共23页
Detecting internal defects,particularly voids behind linings,is critical for ensuring the structural integrity of aging high-speed rail(HSR)tunnel networks.While ground-penetrating radar(GPR)is widely employed,systema... Detecting internal defects,particularly voids behind linings,is critical for ensuring the structural integrity of aging high-speed rail(HSR)tunnel networks.While ground-penetrating radar(GPR)is widely employed,systematic quantification of performance boundaries for air-coupled(A-CGPR)and ground-coupled(G-CGPR)systems within the complex electromagnetic environment of multilayer reinforced HSR tunnels remains limited.This study establishes physics-based quantitative performance limits for A-CGPR and G-CGPR through rigorously validated GPRMax finite-difference time-domain(FDTD)simulations and comprehensive field validation over a 300 m operational HSR tunnel section.Key performance metrics were quantified as functions of:(a)detection distance(A-CGPR:2.0–4.5 m;G-CGPR:≤0.1 m),(b)antenna frequency(A-CGPR:300 MHz;G-CGPR:400/900 MHz),(c)reinforcement configuration(unreinforced,single-layer,multilayer rebar),and(d)void geometry(axial length:0.1–1.0 m;radial depth:0.1–0.5 m).Key findings demonstrate:a.A-CGPR(300 MHz):Reliably detects axial voids≥0.3 m at distances≤3 m in minimally reinforced(single-layer rebar)linings(field R2=0.89).Performance degrades significantly at distances>3 m(>60%signal attenuation at 4.5 m)or under multilayer rebar interference,causing 25%–40%accuracy loss for voids<0.3 m.Optimal distance:2.0–2.5 m.b.G-CGPR(900 MHz):Achieves<5%size measurement error for axial voids≥0.1 m and radial voids≥0.2 m in unreinforced linings.Resolution degrades under multilayer reinforcement due to severe signal attenuation,increasing axial void detection error to 10%–20%for voids≥0.3 m and constraining radial size measurement.c.Synergistic Framework:A hybrid inspection protocol is proposed,integrating A-CGPR(20 km/h)for rapid large-area screening and targeted G-CGPR(3 km/h)for high-resolution verification of identified anomalies.This framework enhances NDT efficiency while reducing estimated lifecycle inspection costs by 34%compared to G-CGPR alone.This research provides the first physics-derived quantitative detection thresholds for A-CGPR and G-CGPR in multi-rebar HSR tunnels,validated through field-correlated simulations.Future work will focus on multi-frequency antenna arrays and deep learning algorithms to mitigate reinforcement interference.The established performance boundaries and hybrid framework offer critical guidance for optimizing tunnel lining inspection strategies in extensive HSR networks. 展开更多
关键词 High-speed railway tunnel air-coupled GPR ground-coupled GPR lining void detection rebar interference nondestructive testing(NDT) quantitative performance boundaries finite-difference time-domain(FDTD) hybrid inspection
在线阅读 下载PDF
Energy saving analysis of a hybrid ground-coupled heat pump project
2
作者 陈九法 薛琴 +1 位作者 乔卫来 安二铭 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期177-181,共5页
A hybrid ground-coupled heat pump(HGCHP)project in Nanjing,China is chosen to analyze the building energy-consumption properties in terms of different control strategies,building envelope and the terminal air-condit... A hybrid ground-coupled heat pump(HGCHP)project in Nanjing,China is chosen to analyze the building energy-consumption properties in terms of different control strategies,building envelope and the terminal air-conditioning system.The HGCHP uses a supplemental heat rejecter to dissipate extra thermal energy to guarantee underground soil heat balance.The software EnergyPlus is employed to simulate the project and design the heat flow of the cooling tower and the borehole heat exchanger(BHE).Then two feasible control strategies for the cooling tower and the borehole heat exchanger are proposed.The energy-saving potential of the building envelope is analyzed in terms of the surface color of the wall/roof.With the same terminal system,it is found that in the cooling season the heat flow of the insulated building with black wall/roof is 1.2 times more than that with white wall/roof.With the same insulated building and gray wall/roof,it is concluded that the heat pump units for a primary air fan-coil system show an annual energy consumption increase of 44.7 GJ compared with a radiant floor system. 展开更多
关键词 hybrid ground-coupled heat pump borehole heat exchanger energy saving
在线阅读 下载PDF
Optimization of Serial Combined System of Ground-Coupled Heat Pump and Solar Collector 被引量:1
3
作者 赵军 陈雁 +1 位作者 卢素珍 崔俊奎 《Transactions of Tianjin University》 EI CAS 2009年第1期37-42,共6页
A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The uni... A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The universal optimal equations were solved by the constrained variable metric method considering both the per-formance and economics. Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating. The results indicated a system coefficient of performance (COP) of 3.9 for the optimal method under the serial heating mode, and 3.2 for the conventional one. In addition, the optimum solution also showed advantages in energy and cost saving, leading to a 16.7% improvement in the heat pump performance at 17.2% less energy consumption and 11.8% lower annual cost, respectively. 展开更多
关键词 ground-solar combined system OPTIMIZATION space heating ground-coupled heat pump
在线阅读 下载PDF
Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System 被引量:1
4
作者 周亚素 Per FAHLEN Torbjrn LINDHOLM 《Journal of Donghua University(English Edition)》 EI CAS 2007年第6期749-755,共7页
Ground-coupled heat pumps(GCHP)are commonly used in residential heating system.To mitigate the boreholes temperature dropping with operating time,a new exhaust-air recharging system is developed.The new recharging sys... Ground-coupled heat pumps(GCHP)are commonly used in residential heating system.To mitigate the boreholes temperature dropping with operating time,a new exhaust-air recharging system is developed.The new recharging system can be used in three operational modes.In this paper,a ground-coupled heat recovery ventilation(HRV)model is discussed.A thermal model is set up to find the optimal brine flow rate and heat transfer allocation ratio between exhaust and supply coils for maximum heat recovery efficiency.Contrary to the conventional liquid-loop HRV systems,the brine temperature entering the exhaust coil never goes blow zero(0℃),and hence defrosting is needless in the ground-coupled HRV system.This can make the ground-coupled HRV system over 20% more efficient than a conventional HRV system at low outdoor temperatures. 展开更多
关键词 a ground-coupled HRV system thermal model heat recovery efficiency coils allocation ratio brine flow rate
在线阅读 下载PDF
An Analytical Model for the Thermal Assessment of a Vertical Double U-Tube Ground-Coupled Heat Pump System in Steady-State Conditions
5
作者 Ali H.Tarrad 《Fluid Dynamics & Materials Processing》 EI 2022年第4期1111-1127,共17页
An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat trans... An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%. 展开更多
关键词 ground-coupled heat pumps borehole thermal resistance double U-tube modeling
在线阅读 下载PDF
Heat balance of solar-soil source heat pump compound system 被引量:3
6
作者 陈金华 包修碧 +1 位作者 彭运林 贾宇 《Journal of Central South University》 SCIE EI CAS 2012年第3期809-815,共7页
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo... Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil. 展开更多
关键词 solar-soil source heat pump compound system heat balance ground-coupled heat pump
在线阅读 下载PDF
Experimental study on heat exchange of several types of exchangers
7
作者 周志华 赵振华 于洋 《Journal of Central South University》 SCIE EI CAS 2009年第S1期204-208,共5页
Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers bu... Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers buried directly. The result indicates that the heat exchanger makes the best use of structure of building,saves land,reduces the construction cost,and the heat exchanged is obviously more than exchangers buried directly. In winter condition,when W-shape pipe heat exchanger in pile foundation is 50 m deep and diameter is 800 mm,it transfers 1.2-1.3 times as large as the one of single U-shape buried directly at the flow rate of 0.6 m/s,whose borehole diameter is 300 mm. And in summer condition it does about 2.0-2.3 times as that of U-shape one. 展开更多
关键词 ground-coupled source HEAT pump HEAT EXCHANGER in PILE FOUNDATION single U-shape pipe HEAT EXCHANGER BURIED directly HEAT exchange
在线阅读 下载PDF
Performance analysis of deep borehole heat exchangers for decarbonization of heating systems
8
作者 Andreas E.D.Lund 《Deep Underground Science and Engineering》 2024年第3期349-357,共9页
Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Her... Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Here the thermal behavior of deep borehole exchangers(DBHEs)ranging from 1 to 2 km was analyzed for various heat flow profiles.A strong correlation between thermal energy extraction and power output from DBHEs was found,also influenced by the heating profile employed.Longer operating time over the year typically resulted in higher energy production,while shorter one yielded higher average thermal power output,highlighting the importance of the choice of heating strategy and system design for optimal performance of DBHEs.Short breaks in operation for regenerating the borehole,for example,with waste heat,proved to be favorable for the performance yielding an overall heat output close to the same as with continuous extraction of heat.The results demonstrate the usefulness of deep boreholes for dense urban areas with less available space.As the heat production from a single DBHE in Finnish conditions ranges from half up to even a few GWh a year,the technology is best suitable for larger heat loads. 展开更多
关键词 clean energy deep borehole exchangers energy transition geothermal heat ground-coupled heat pump
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部