The integration of renewable energy sources into modern power systems necessitates efficient and robust control strategies to address challenges such as power quality,stability,and dynamic environmental variations.Thi...The integration of renewable energy sources into modern power systems necessitates efficient and robust control strategies to address challenges such as power quality,stability,and dynamic environmental variations.This paper presents a novel sparrow search algorithm(SSA)-tuned proportional-integral(PI)controller for grid-connected photovoltaic(PV)systems,designed to optimize dynamic perfor-mance,energy extraction,and power quality.Key contributions include the development of a systematic SSA-based optimization frame-work for real-time PI parameter tuning,ensuring precise voltage and current regulation,improved maximum power point tracking(MPPT)efficiency,and minimized total harmonic distortion(THD).The proposed approach is evaluated against conventional PSO-based and P&O controllers through comprehensive simulations,demonstrating its superior performance across key metrics:a 39.47%faster response time compared to PSO,a 12.06%increase in peak active power relative to P&O,and a 52.38%reduction in THD,ensuring compliance with IEEE grid standards.Moreover,the SSA-tuned PI controller exhibits enhanced adaptability to dynamic irradiancefluc-tuations,rapid response time,and robust grid integration under varying conditions,making it highly suitable for real-time smart grid applications.This work establishes the SSA-tuned PI controller as a reliable and efficient solution for improving PV system performance in grid-connected scenarios,while also setting the foundation for future research into multi-objective optimization,experimental valida-tion,and hybrid renewable energy systems.展开更多
Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,th...Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,the presence of a DC offset in the measured current can disrupt the regulation of grid currents and significantly degrade system performance.In this work,a fault-tolerant control approach is introduced to counteract the impact of such offset faults through a dedicated current compensation mechanism.The proposed solution is built around two main stages:(i)detecting and isolating DC offset faults that may appear in one or multiple phases of the measured grid currents,and(ii)estimating the fault magnitude and reconstructing the corrected current signal.The offset magnitude is obtained analytically by examining the grid current projected onto the synchronous d-axis at the grid angular frequency,eliminating the need for any additional sensing hardware.Simulation and experimental investigations conducted under several fault scenarios confirm the robustness of the proposed strategy and highlight significant improvements in detection speed and diagnostic accuracy.展开更多
Around the world,there has been a notable shift toward the use of renewable energy technology due to the growing demand for energy and the ongoing depletion of conventional resources,such as fossil fuels.Following thi...Around the world,there has been a notable shift toward the use of renewable energy technology due to the growing demand for energy and the ongoing depletion of conventional resources,such as fossil fuels.Following this worldwide trend,Brunei’s government has initiated several strategic programs aimed at encouraging the establishment of energy from renewable sources in the nation’s energy mix.These initiatives are designed not only to support environmental sustainability but also to make energy from renewable sources increasingly competitive in comparison to more conventional energy sources like gas and oil,which have historically dominated Brunei’s energy market.The optimization of a hybrid energy system that combines diesel generators,solar photovoltaic(PV)panels,and the national power grid is the focus of this study.The objective is to identify the most cost-effective and environmentally sustainable configuration that can reliably meet local energy demands.During optimization,several configuration was tried and tested,including only grid,PV and Grid and PV-generator.HOMER(Hybrid Optimization of Multiple Energy Resources)software,a popular simulation tool that makes it possible to simulate and analyze hybrid energy systems,is utilized in the optimization process.Inside the HOMER Pro optimization,various system configuration is taken into account for the optimization.While simulating,it takes into account different combinations of components such as solar panels,wind turbines and batteries.Later on,it is being ranked by different factors such as net present cost(NPC),Cost of Energy(COE),etc.A comprehensive techno-economic research is carried out to evaluate various system configurations,considering key performance indicators such as total energy generation cost,operational expenditure,and greenhouse gas emissions.The results provide valuable insights into how renewable-based hybrid systems can reduce environmental impact while maintaining economic viability,supporting Brunei’s broader goals of energy diversification and sustainability.The study also emphasizes how such hybrid systems could be scaled for off-grid and rural populations in Brunei,where a dependable electricity supply is still a problem.Furthermore,sensitivity analyses were performed to evaluate the effects of variations in solar irradiation,load demand,and fuel prices on the overall system performance.Policymakers and energy planners can use these insights to help them make data-driven decisions about future investments in infrastructure for renewable energy.展开更多
This paper presents a novel active disturbance rejection control(ADRC)scheme based on a cascade connection of generalized proportional integral observers(GPIOs)with internal models designed to estimate both polynomial...This paper presents a novel active disturbance rejection control(ADRC)scheme based on a cascade connection of generalized proportional integral observers(GPIOs)with internal models designed to estimate both polynomial and resonant disturbances.In this estimator structure,referred to as Cascade GPIO(CGPIO),the total disturbance sensitivity is the product of the sensitivities at each cascade level.This approach improves system performance against both periodic and non-periodic disturbances and enhances robustness under frequency variations in harmonic components.Additionally,the decoupled nature of the estimator reduces the order of the GPIOs,thereby simplifying tuning and limiting observer gains.The proposed control scheme is supported by a frequency-domain analysis and is experimentally validated in the current control of a grid-connected converter subject to control gain uncertainties,harmonic distortion,frequency deviations,and measurement noise.Experimental results demonstrate that the CGPIO-based ADRC outperforms benchmark solutions,including proportional-integral(PI)and proportional-resonant(PR)controllers.展开更多
[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in t...[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in this study and its auto-control sys- tem field assembled and debugged. [Method] Based on controlling equipment and setting parameters on the configuration interface, the operation state of the control equipments could be real-time monitored and controlled with the help of configura- tion software. [Result] The result showed that the equipment system could reduce the temperature into 12 ℃ with the error of +0.5 ℃within 110 minutes when the fermentation temperature is set at 12 ℃ in real production. [Conclusion] The auto- control system of fruit wine production line was easy to be assembled and de- bugged to meet demands of different fruit wine productions.展开更多
The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS ...The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units.展开更多
Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped...Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped varying trend of TE increasing rate more accurately, first, two S-shaped testing-effort functions(TEFs), i.e.,delayed S-shaped TEF(DS-TEF) and inflected S-shaped TEF(IS-TEF), are proposed. Then these two TEFs are incorporated into various types(exponential-type, delayed S-shaped and inflected S-shaped) of non-homogeneous Poisson process(NHPP)SRGMs with two forms of ID respectively for obtaining a series of new NHPP SRGMs which consider S-shaped TEFs as well as ID. Finally these new SRGMs and several comparison NHPP SRGMs are applied into four real failure data-sets respectively for investigating the fitting and prediction power of these new SRGMs.The experimental results show that:(i) the proposed IS-TEF is more suitable and flexible for describing the consumption of TE than the previous TEFs;(ii) incorporating TEFs into the inflected S-shaped NHPP SRGM may be more effective and appropriate compared with the exponential-type and the delayed S-shaped NHPP SRGMs;(iii) the inflected S-shaped NHPP SRGM considering both IS-TEF and ID yields the most accurate fitting and prediction results than the other comparison NHPP SRGMs.展开更多
This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented ...This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.展开更多
Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o...Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.展开更多
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a...Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.展开更多
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of...This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved.展开更多
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima...This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.展开更多
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T...In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.展开更多
In view of the flaws of component-based software (CBS) reliability modeling and analysis, the low recognition degree of debugging process, too many assumptions and difficulties in obtaining the solution, a CBS relia...In view of the flaws of component-based software (CBS) reliability modeling and analysis, the low recognition degree of debugging process, too many assumptions and difficulties in obtaining the solution, a CBS reliability simulation process is presented incorporating the imperfect debugging and the limitation of debugging resources. Considering the effect of imperfect debugging on fault detec- tion and correction process, a CBS integration testing model is sketched by multi-queue muhichannel and finite server queuing model (MMFSQM). Compared with the analytical method based on pa- rameters and other nonparametric approaches, the simulation approach can relax more of the usual reliability modeling assumptions and effectively expound integration testing process of CBS. Then, CBS reliability process simulation procedure is developed accordingly. The proposed simulation ap- proach is validated to be sound and effective by simulation experiment studies and analysis.展开更多
In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and ba...In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.展开更多
Fault localization is an important topic in software testing, as it enables the developer to specify fault location in their code. One of the dynamic fault localization techniques is statistical debugging. In this stu...Fault localization is an important topic in software testing, as it enables the developer to specify fault location in their code. One of the dynamic fault localization techniques is statistical debugging. In this study, two statistical debugging algorithms are implemented, SOBER and Cause Isolation, and then the experimental works are conducted on five programs coded using Python as an example of well-known dynamic programming language. Results showed that in programs that contain only single bug, the two studied statistical debugging algorithms are very effective to localize a bug. In programs that have more than one bug, SOBER algorithm has limitations related to nested predicates, rarely observed predicates and complement predicates. The Cause Isolation has limitations related to sorting predicates based on importance and detecting bugs in predicate condition. The accuracy of both SOBER and Cause Isolation is affected by the program size. Quality comparison showed that SOBER algorithm requires more code examination than Cause Isolation to discover the bugs.展开更多
For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int...For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.展开更多
Software reliability model is the tool to measure the software reliability quantitatively. Hazard-Rate model is one of the most popular ones. The purpose of our research is to propose the hazard-rate model considering...Software reliability model is the tool to measure the software reliability quantitatively. Hazard-Rate model is one of the most popular ones. The purpose of our research is to propose the hazard-rate model considering fault level for Open Source Software (OSS). Moreover, we aim to adapt our proposed model to the hazard-rate considering the imperfect debugging environment. We have analyzed the trend of fault severity level by using fault data in Bug Tracking System (BTS) and proposed our model based on the result of analysis. Also, we have shown the numerical example for evaluating the performance of our proposed model. Furthermore, we have extended our proposed model to the hazard-rate considering the imperfect debugging environment and showed numerical example for evaluating the possibility of application. As the result, we found out that performance of our proposed model is better than typical hazard-rate models. Also, we verified the possibility of application of proposed model to hazard-rate model considering imperfect debugging.展开更多
This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test eq...This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test equipment, we have used principal and subordinate structures, and interconnected the host computer and the front-end machine via Ethernet. The front-end machine is based on the ARM7 (advanced reduced instruction set computing (RISC) machine) technique, the processor of which runs an embedded operating system, namely, uClinux OS. We have analyzed the system telecommunication, human-machine interface circuit, transmitter mandrel interface circuit, receiver mandrel interface circuit, and board-level test interface circuit. The software used in the system consists of the embedded front-computer software and the host application software. We have explained in detail the flow chart of the boot loader in the embedded front-computer software. The host application software is composed of four application subroutines, which match with the functional modules of the system hardware. A net communication program based on the server^client mode is implemented by means of socket programming and multi-thread programming. Test results indicate that the data transmission rate of the system is higher than 1 MB/s, which completely meets the current requirements of the data transmission rate between the tool system and the wireline telemetry device. Application of the debugging system, which includes multiple level test methods, shows that the proposed system can fully meet the test requirements of MPAL at various levels.展开更多
Because of the inevitable debugging lag,imperfect debugging process is used to replace perfect debugging process in the analysis of software reliability growth model.Considering neither testing-effort nor testing cove...Because of the inevitable debugging lag,imperfect debugging process is used to replace perfect debugging process in the analysis of software reliability growth model.Considering neither testing-effort nor testing coverage can describe software reliability for imperfect debugging completely,by hybridizing testing-effort with testing coverage under imperfect debugging,this paper proposes a new model named GMW-LO-ID.Under the assumption that the number of faults is proportional to the current number of detected faults,this model combines generalized modified Weibull(GMW)testing-effort function with logistic(LO)testing coverage function,and inherits GMW's amazing flexibility and LO's high fitting precision.Furthermore,the fitting accuracy and predictive power are verified by two series of experiments and we can draw a conclusion that our model fits the actual failure data better and predicts the software future behavior better than other ten traditional models,which only consider one or two points of testing-effort,testing coverage and imperfect debugging.展开更多
文摘The integration of renewable energy sources into modern power systems necessitates efficient and robust control strategies to address challenges such as power quality,stability,and dynamic environmental variations.This paper presents a novel sparrow search algorithm(SSA)-tuned proportional-integral(PI)controller for grid-connected photovoltaic(PV)systems,designed to optimize dynamic perfor-mance,energy extraction,and power quality.Key contributions include the development of a systematic SSA-based optimization frame-work for real-time PI parameter tuning,ensuring precise voltage and current regulation,improved maximum power point tracking(MPPT)efficiency,and minimized total harmonic distortion(THD).The proposed approach is evaluated against conventional PSO-based and P&O controllers through comprehensive simulations,demonstrating its superior performance across key metrics:a 39.47%faster response time compared to PSO,a 12.06%increase in peak active power relative to P&O,and a 52.38%reduction in THD,ensuring compliance with IEEE grid standards.Moreover,the SSA-tuned PI controller exhibits enhanced adaptability to dynamic irradiancefluc-tuations,rapid response time,and robust grid integration under varying conditions,making it highly suitable for real-time smart grid applications.This work establishes the SSA-tuned PI controller as a reliable and efficient solution for improving PV system performance in grid-connected scenarios,while also setting the foundation for future research into multi-objective optimization,experimental valida-tion,and hybrid renewable energy systems.
文摘Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,the presence of a DC offset in the measured current can disrupt the regulation of grid currents and significantly degrade system performance.In this work,a fault-tolerant control approach is introduced to counteract the impact of such offset faults through a dedicated current compensation mechanism.The proposed solution is built around two main stages:(i)detecting and isolating DC offset faults that may appear in one or multiple phases of the measured grid currents,and(ii)estimating the fault magnitude and reconstructing the corrected current signal.The offset magnitude is obtained analytically by examining the grid current projected onto the synchronous d-axis at the grid angular frequency,eliminating the need for any additional sensing hardware.Simulation and experimental investigations conducted under several fault scenarios confirm the robustness of the proposed strategy and highlight significant improvements in detection speed and diagnostic accuracy.
基金funded through Deanship of Scientific Research at Northern Border University,Arar,Saudi Arabia—project number“NBU-FFR-2025-3623-06”.
文摘Around the world,there has been a notable shift toward the use of renewable energy technology due to the growing demand for energy and the ongoing depletion of conventional resources,such as fossil fuels.Following this worldwide trend,Brunei’s government has initiated several strategic programs aimed at encouraging the establishment of energy from renewable sources in the nation’s energy mix.These initiatives are designed not only to support environmental sustainability but also to make energy from renewable sources increasingly competitive in comparison to more conventional energy sources like gas and oil,which have historically dominated Brunei’s energy market.The optimization of a hybrid energy system that combines diesel generators,solar photovoltaic(PV)panels,and the national power grid is the focus of this study.The objective is to identify the most cost-effective and environmentally sustainable configuration that can reliably meet local energy demands.During optimization,several configuration was tried and tested,including only grid,PV and Grid and PV-generator.HOMER(Hybrid Optimization of Multiple Energy Resources)software,a popular simulation tool that makes it possible to simulate and analyze hybrid energy systems,is utilized in the optimization process.Inside the HOMER Pro optimization,various system configuration is taken into account for the optimization.While simulating,it takes into account different combinations of components such as solar panels,wind turbines and batteries.Later on,it is being ranked by different factors such as net present cost(NPC),Cost of Energy(COE),etc.A comprehensive techno-economic research is carried out to evaluate various system configurations,considering key performance indicators such as total energy generation cost,operational expenditure,and greenhouse gas emissions.The results provide valuable insights into how renewable-based hybrid systems can reduce environmental impact while maintaining economic viability,supporting Brunei’s broader goals of energy diversification and sustainability.The study also emphasizes how such hybrid systems could be scaled for off-grid and rural populations in Brunei,where a dependable electricity supply is still a problem.Furthermore,sensitivity analyses were performed to evaluate the effects of variations in solar irradiation,load demand,and fuel prices on the overall system performance.Policymakers and energy planners can use these insights to help them make data-driven decisions about future investments in infrastructure for renewable energy.
文摘This paper presents a novel active disturbance rejection control(ADRC)scheme based on a cascade connection of generalized proportional integral observers(GPIOs)with internal models designed to estimate both polynomial and resonant disturbances.In this estimator structure,referred to as Cascade GPIO(CGPIO),the total disturbance sensitivity is the product of the sensitivities at each cascade level.This approach improves system performance against both periodic and non-periodic disturbances and enhances robustness under frequency variations in harmonic components.Additionally,the decoupled nature of the estimator reduces the order of the GPIOs,thereby simplifying tuning and limiting observer gains.The proposed control scheme is supported by a frequency-domain analysis and is experimentally validated in the current control of a grid-connected converter subject to control gain uncertainties,harmonic distortion,frequency deviations,and measurement noise.Experimental results demonstrate that the CGPIO-based ADRC outperforms benchmark solutions,including proportional-integral(PI)and proportional-resonant(PR)controllers.
基金Supported by Fundamental Research Foundation of GXAAS(GNK2013YM02)~~
文摘[Objective] The aim was to test the controlling effect of cleaning steriliza- tion system, material conveying system, and fermentation jar cooling system with equip- ments of fruit wine production line introduced in this study and its auto-control sys- tem field assembled and debugged. [Method] Based on controlling equipment and setting parameters on the configuration interface, the operation state of the control equipments could be real-time monitored and controlled with the help of configura- tion software. [Result] The result showed that the equipment system could reduce the temperature into 12 ℃ with the error of +0.5 ℃within 110 minutes when the fermentation temperature is set at 12 ℃ in real production. [Conclusion] The auto- control system of fruit wine production line was easy to be assembled and de- bugged to meet demands of different fruit wine productions.
文摘The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units.
基金supported by the Pre-research Foundation of CPLA General Equipment Department
文摘Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped varying trend of TE increasing rate more accurately, first, two S-shaped testing-effort functions(TEFs), i.e.,delayed S-shaped TEF(DS-TEF) and inflected S-shaped TEF(IS-TEF), are proposed. Then these two TEFs are incorporated into various types(exponential-type, delayed S-shaped and inflected S-shaped) of non-homogeneous Poisson process(NHPP)SRGMs with two forms of ID respectively for obtaining a series of new NHPP SRGMs which consider S-shaped TEFs as well as ID. Finally these new SRGMs and several comparison NHPP SRGMs are applied into four real failure data-sets respectively for investigating the fitting and prediction power of these new SRGMs.The experimental results show that:(i) the proposed IS-TEF is more suitable and flexible for describing the consumption of TE than the previous TEFs;(ii) incorporating TEFs into the inflected S-shaped NHPP SRGM may be more effective and appropriate compared with the exponential-type and the delayed S-shaped NHPP SRGMs;(iii) the inflected S-shaped NHPP SRGM considering both IS-TEF and ID yields the most accurate fitting and prediction results than the other comparison NHPP SRGMs.
基金supported by the National Natural Science Foundation of China(No.50907057)the National High-Tech Research and Development Program (863) of China(No.2007AA05Z419)
文摘This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.
基金supported by National Natural Science Foundation of China (No. 61573303)Natural Science Foundation of Hebei Province (No. E2016203092)
文摘Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.
文摘Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.
基金supported by the National Natural Science Foundation of China(No.61903291)。
文摘This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved.
文摘This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.
基金supported by Delta Power Electronic Science and Education Development in 2007 (Grant No.DRES2007002)
文摘In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.
基金Supported by the National High Technology Research and Development Program of China(No.2008AA01A201)the National Nature Science Foundation of China(No.60503015,90818016)
文摘In view of the flaws of component-based software (CBS) reliability modeling and analysis, the low recognition degree of debugging process, too many assumptions and difficulties in obtaining the solution, a CBS reliability simulation process is presented incorporating the imperfect debugging and the limitation of debugging resources. Considering the effect of imperfect debugging on fault detec- tion and correction process, a CBS integration testing model is sketched by multi-queue muhichannel and finite server queuing model (MMFSQM). Compared with the analytical method based on pa- rameters and other nonparametric approaches, the simulation approach can relax more of the usual reliability modeling assumptions and effectively expound integration testing process of CBS. Then, CBS reliability process simulation procedure is developed accordingly. The proposed simulation ap- proach is validated to be sound and effective by simulation experiment studies and analysis.
基金supported by North China Electric Power Research Institute’s Self-Funded Science and Technology Project“Research on Distributed Energy Storage Optimal Configuration and Operation Control Technology for Photovoltaic Promotion in the Entire County”(KJZ2022049).
文摘In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.
文摘Fault localization is an important topic in software testing, as it enables the developer to specify fault location in their code. One of the dynamic fault localization techniques is statistical debugging. In this study, two statistical debugging algorithms are implemented, SOBER and Cause Isolation, and then the experimental works are conducted on five programs coded using Python as an example of well-known dynamic programming language. Results showed that in programs that contain only single bug, the two studied statistical debugging algorithms are very effective to localize a bug. In programs that have more than one bug, SOBER algorithm has limitations related to nested predicates, rarely observed predicates and complement predicates. The Cause Isolation has limitations related to sorting predicates based on importance and detecting bugs in predicate condition. The accuracy of both SOBER and Cause Isolation is affected by the program size. Quality comparison showed that SOBER algorithm requires more code examination than Cause Isolation to discover the bugs.
文摘For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.
文摘Software reliability model is the tool to measure the software reliability quantitatively. Hazard-Rate model is one of the most popular ones. The purpose of our research is to propose the hazard-rate model considering fault level for Open Source Software (OSS). Moreover, we aim to adapt our proposed model to the hazard-rate considering the imperfect debugging environment. We have analyzed the trend of fault severity level by using fault data in Bug Tracking System (BTS) and proposed our model based on the result of analysis. Also, we have shown the numerical example for evaluating the performance of our proposed model. Furthermore, we have extended our proposed model to the hazard-rate considering the imperfect debugging environment and showed numerical example for evaluating the possibility of application. As the result, we found out that performance of our proposed model is better than typical hazard-rate models. Also, we verified the possibility of application of proposed model to hazard-rate model considering imperfect debugging.
基金supported by National Science Foundation of China (61102102, 11134011, 11204380 and 11374371)Major National Science and Technology Projects (2011ZX05020-002)+2 种基金PetroChina Innovation Foundation (2014D-5006-0307)Science and Technology Project of CNPC (2014A-3912 and 2011B-4001)the Foundation of China University of Petroleum (KYJJ2012-05-07)
文摘This paper presents a debugging system for multi-pole array acoustic logging (MPAL) tools. The debugging system proposed in this study can debug the MPAL tool system, sub-system and local electronics. In the test equipment, we have used principal and subordinate structures, and interconnected the host computer and the front-end machine via Ethernet. The front-end machine is based on the ARM7 (advanced reduced instruction set computing (RISC) machine) technique, the processor of which runs an embedded operating system, namely, uClinux OS. We have analyzed the system telecommunication, human-machine interface circuit, transmitter mandrel interface circuit, receiver mandrel interface circuit, and board-level test interface circuit. The software used in the system consists of the embedded front-computer software and the host application software. We have explained in detail the flow chart of the boot loader in the embedded front-computer software. The host application software is composed of four application subroutines, which match with the functional modules of the system hardware. A net communication program based on the server^client mode is implemented by means of socket programming and multi-thread programming. Test results indicate that the data transmission rate of the system is higher than 1 MB/s, which completely meets the current requirements of the data transmission rate between the tool system and the wireline telemetry device. Application of the debugging system, which includes multiple level test methods, shows that the proposed system can fully meet the test requirements of MPAL at various levels.
基金supported by the National Natural Science Foundation of China(No.U1433116)the Aviation Science Foundation of China(No.20145752033)
文摘Because of the inevitable debugging lag,imperfect debugging process is used to replace perfect debugging process in the analysis of software reliability growth model.Considering neither testing-effort nor testing coverage can describe software reliability for imperfect debugging completely,by hybridizing testing-effort with testing coverage under imperfect debugging,this paper proposes a new model named GMW-LO-ID.Under the assumption that the number of faults is proportional to the current number of detected faults,this model combines generalized modified Weibull(GMW)testing-effort function with logistic(LO)testing coverage function,and inherits GMW's amazing flexibility and LO's high fitting precision.Furthermore,the fitting accuracy and predictive power are verified by two series of experiments and we can draw a conclusion that our model fits the actual failure data better and predicts the software future behavior better than other ten traditional models,which only consider one or two points of testing-effort,testing coverage and imperfect debugging.