期刊文献+
共找到3,367篇文章
< 1 2 169 >
每页显示 20 50 100
A FPGA-based high-order harmonic current control of resonant power supply system in rapid-cycling synchrotron
1
作者 Ran Li Jun Li +4 位作者 Guo‑Dong Zhao Wen‑Qing Zhang Yun‑Tao Liu Yuan Huang Xin Qi 《Nuclear Science and Techniques》 2025年第8期111-125,共15页
The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW... The rapid-cycling synchrotron(RCS)is a crucial device for proton beam acceleration at the China Spallation Neutron Source,operating at a repetition frequency of 25 Hz.The beam power was increased from 100 kW to 140 kW.This increase makes the on-orbit beam more sensitive to disturbances in various parts of the accelerator,including the RCS magnet power supply system.This paper presents a method for reducing the high-order harmonic current error in resonant power supplies for dipole magnets and examines its impact on the horizontal orbit offset of the beam.It adopts a control scheme that combines high-order harmonic current compensation with PI double-loop control of the resonant power supply.By utilizing the existing digital controller hardware in the RCS power supply system,this study demonstrates how to achieve precise control of the 50 Hz harmonic current output in a cost-effective manner.Ultimately,it enhances performance by reducing the current error by up to 50%and provides methodological support for future upgrades to the power supply system.Such improvements enhance the stability of the RCS,reducing the beam horizontal orbit deviation by at least 19.8%. 展开更多
关键词 current error analysis Magnets saturation White resonant circuit FPGA harmonic current compensation algorithm
在线阅读 下载PDF
Coordination of multiple grid-connected inverters for harmonic compensation
2
作者 郭晓瑞 郭吉丰 王剑 《Journal of Central South University》 SCIE EI CAS 2014年第8期3126-3132,共7页
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l... For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy. 展开更多
关键词 active filter harmonicS grid-connected inverter decoupling control COORDINATION
在线阅读 下载PDF
Harmonic Current′s Coupling Effect on the Main Motion of Temper Mill Set 被引量:6
3
作者 HE Jian-jun YU Shou-yi ZHONG Jue 《Journal of Central South University》 SCIE EI CAS 2000年第3期162-164,共3页
The paper probes into a probable condition that causes temper mill chatter from aspect of electromechanical coupling of complex electromechanical system, and mainly studies the effect of temper mill electrical driving... The paper probes into a probable condition that causes temper mill chatter from aspect of electromechanical coupling of complex electromechanical system, and mainly studies the effect of temper mill electrical driving system harmonic current on the main motion of temper mill set. Aiming at the electrical driving system of CM04 temper mill, the effect of harmonic current is analyzed and evaluated according to different load. Combining the features of CM04 temper mill′s structure and its working state, the paper discusses in every detail how the harmonic current in main circuit, which can be regarded as a disturbance via feedback control circuit , influences main motion of temper mill set. 展开更多
关键词 ELECTROMECHANICAL coupling TEMPER MILL harmonic current ROLLING MILL chatter
在线阅读 下载PDF
Proportional integral plus multi-frequency resonant current controller for grid-connected voltage source converter under imbalanced and distorted supply voltage conditions 被引量:15
4
作者 Jia-bing HU Wei ZHANG +2 位作者 Hong-sheng WANG Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第10期1532-1540,共9页
This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented ... This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion. 展开更多
关键词 grid-connected voltage source converter (GC-VSC) Proportional integral plus multi-frequency resonant (PI+MFR) IMBALANCE harmonics distortion
原文传递
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:3
5
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
在线阅读 下载PDF
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
6
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 Active filter harmonic Reactive current Real-time detection Single-phase circuit Electric-network
在线阅读 下载PDF
Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection 被引量:4
7
作者 Zhifeng Zhang Yue Wu +1 位作者 Hequn Su Quanzeng Sun 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期306-314,共9页
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma... This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control. 展开更多
关键词 Extended rotating coordinate transformation matrix Fault-tolerant control Fifth harmonic current injection Modified six-phase static coordinate transformation matrix Dual three-phase permanent magnet synchronous motor Torque ripple
在线阅读 下载PDF
Torque Improvement of Spoke-type Permanent Magnet Motor with Auxiliary Stator Using Harmonic Current Control Strategy 被引量:1
8
作者 Hao Wu Wenliang Zhao +1 位作者 Zheng Li Xiuhe Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期210-217,共8页
The spoke-type permanent magnet motor with auxiliary stator exhibits high torque performance owing to the flux focus effects.To further improve its torque density,this paper proposes a control method by using harmonic... The spoke-type permanent magnet motor with auxiliary stator exhibits high torque performance owing to the flux focus effects.To further improve its torque density,this paper proposes a control method by using harmonic current strategy.Based on the theoretical analysis,a 3-D torque look-up table by dq-axis current and electrical angle is established with the aid of the finite element method(FEM).The maximum torque per ampere curve at each rotor position is identified and summarized to adequately indicate the relationship between torque and current amplitude of the motor.Through theoretical derivation,it is concluded that the minimum torque cost curve is the contour line of?Te/?i2,which can be employed to identify the harmonic current for torque density improvement.Compared to traditional strategies,the proposed control strategy can increase torque density of forward and reverse torque by 1.22%and 1.40%,respectively.The experimental results verify the analysis and simulation results,as well as prove the effectiveness of the proposed strategy. 展开更多
关键词 Spoke-type permanent magnet motor harmonic current Finite element method Torque density Torque cost
在线阅读 下载PDF
Higher Harmonics Induced by Waves Propagating over A Submerged Obstacle in the Presence of Uniform Current 被引量:5
9
作者 宁德志 林红星 +1 位作者 滕斌 邹青萍 《China Ocean Engineering》 SCIE EI CSCD 2014年第6期725-738,共14页
To investigate higher harmonics induced by a submerged obstacle in the presence of uniform current, a 2D fully nonlinear numerical wave flume(NWF) is developed by use of a time-domain higher-order boundary element m... To investigate higher harmonics induced by a submerged obstacle in the presence of uniform current, a 2D fully nonlinear numerical wave flume(NWF) is developed by use of a time-domain higher-order boundary element method(HOBEM) based on potential flow theory. A four-point method is developed to decompose higher bound and free harmonic waves propagating upstream and downstream around the obstacle. The model predictions are in good agreement with the experimental data for free harmonics induced by a submerged horizontal cylinder in the absence of currents. This serves as a benchmark to reveal the current effects on higher harmonic waves. The peak value of non-dimensional second free harmonic amplitude is shifted upstream for the opposing current relative to that for zero current with the variation of current-free incident wave amplitude, and it is vice versa for the following current. The second-order analysis shows a resonant behavior which is related to the ratio of the cylinder diameter to the second bound mode wavelength over the cylinder. The second-order resonant position slightly downshifted for the opposing current and upshifted for the following current. 展开更多
关键词 higher harmonics wave-current interaction HOBEM free mode
在线阅读 下载PDF
Harmonic Currents of Semiconductor Pulse Switching Converters
10
作者 Petr Bilik Jan Zidek +1 位作者 Vaclav Kus Tereza Josefova 《Energy and Power Engineering》 2013年第4期1120-1125,共6页
Due to the operation of power semiconductor switching converters, the content of harmonic currents, which these switching converters take from the feed array, is still increasing. One of the possible ways of minimizin... Due to the operation of power semiconductor switching converters, the content of harmonic currents, which these switching converters take from the feed array, is still increasing. One of the possible ways of minimizing these currents is the use of pulse switching converters. On one hand, the original, characteristic harmonic ones are minimized, but, on the other hand, new frequencies caused by the modulation frequency appear in the current spectrum. The level of the currents of these frequencies is small and is scarcely dependent on the load of the converter. It may happen that the proportional value of the monitored harmonic one is high, although the absolute value is low. In the article presented, there is a description of the activity of the pulse voltage rectifier and an analysis of the current taken. The other part contains the results of the harmonic analysis of the stated current, including both the absolute and proportional values according to the load. In the conclusion, there are results of measurements of pulsed switching converters taken from the real measurement. 展开更多
关键词 RECTIFIERS harmonic Analysis harmonic DISTORTION Power System harmonicS current Measurement
暂未订购
Analysis of Harmonic Current in Permanent Magnet Synchronous Motor and Its Effect on Motor Torque
11
作者 Xiaoyuan Wang Wei Zhou Ruzhen Dou 《Journal of Electromagnetic Analysis and Applications》 2012年第1期15-20,共6页
The inverter is used as the power supply of modern permanent magnet synchronous motor (PMSM). The inverter may produce harmonics in inversion process and form harmonic currents in motor stator winding which can lead t... The inverter is used as the power supply of modern permanent magnet synchronous motor (PMSM). The inverter may produce harmonics in inversion process and form harmonic currents in motor stator winding which can lead to factors against motor smooth operation such as torque fluctuating and winding heating. This article focuses on the harmonic currents formed in the motor stator winding by getting the harmonics frequency spectrum with software. The effect of harmonic currents to motor torque is analyzed with the finite element method (FEM). 展开更多
关键词 harmonic current INVERSION TORQUE RIPPLE SPWM Finite Element Method
在线阅读 下载PDF
Coordinated Control of Second-order Harmonic Voltage and Current Fluctuations in Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage at Variable Output Frequencies
12
作者 Ye Zhang Zixin Li +3 位作者 Fanqiang Gao Jinhao Zhang Cong Zhao Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第4期481-492,共12页
In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.T... In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.There exist limitations in handling these fluctuations at variable output frequencies when employing proportional-integral(PI)control to the dc-dc stage.This paper aims to coordinately control these second-order harmonic voltage and current fluctuations in the CHBI.The presented method configures a specific second-order harmonic voltage reference,equipped with a maximum voltage fluctuation constraint and a suitable phase,for the dc-dc stage.A PI-resonant controller is used to track the configured reference.This allows for regulating the second-order harmonic fluctuation in the average dc-link voltage among the SMs within a certain value.Importantly,the second-order harmonic fluctuation in the dc-dc current can also be reduced.Simulation and experimental results demonstrate the effectiveness of the presented method. 展开更多
关键词 Cascaded H-bridge inverter(CHBI) DC-DC current reduction Second-order harmonic fluctuation Variable frequencies Proportional-integral-resonant
在线阅读 下载PDF
An Insight into the Second-Harmonic Current Reduction Control Strategies in Two-Stage Converters
13
作者 Lei Ren Lei Zhang 《Energy Engineering》 EI 2022年第3期1179-1196,共18页
Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc... Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc converter(FDC).To reduce the SHC,optimizing the control strategy of the FDC is an effective and costless approach.Fromthe view of visual impedance,this paper conducts an intensive study on the SHC reduction strategies.Origin of the SHC is illustrated first.Then,the equivalent circuit models of the FDC under different control strategies are proposed to analyse the SHC propagation characteristic.The derived model can offer a better insight into how the inductor SHC is affected by the control parameters.According to the derived models,a synthesis of different control strategies is presented and the relevant parameters are listed for control design to achieve better suppression effect.The benefits and limitations of these control strategies are also discussed.Based on the proposed equivalent circuit models,several optimization methods are proposed to enhance the effect.A 1500 VA TSI prototype is built and simulated on MATLAB/Simulink,verifying the effectiveness of the proposed optimization methods.This paper is aimed to provide a guideline for the control design and control optimization of the TSIs. 展开更多
关键词 Two-stage single-phase inverter(TSI) second harmonic current(SHC) equivalent circuit models optimization
在线阅读 下载PDF
Analysis Magnetization Current of Harmonic Phenomena and Power Factor as Indicators of Core Saturation at Transformer 3-Phase
14
作者 Erwin Dermawan Deni Almanda +2 位作者 Laelatus Zahro Anwar Ilmar Ramadhan Ery Diniardi 《Journal of Power and Energy Engineering》 2016年第5期1-6,共6页
Saturation is a condition in which the magnets are fully transformer cores and generate maximum magnetic flux. Some parts affect the resilience and create distortions that can harm the heart. Core saturation can also ... Saturation is a condition in which the magnets are fully transformer cores and generate maximum magnetic flux. Some parts affect the resilience and create distortions that can harm the heart. Core saturation can also increase the temperature and magnetization current transformer. In this study, we proposed a measurement method to obtain the necessary parameters to calculate a reliable indicator of the state of the transformer core saturation. The main effects of nonlinear flow in the transformer core are saturation, eddy current and hysteresis. In saturation, the core transformer is as a source of generating harmonic currents, some of which will flow directly to the primary and secondary windings. The method is based on the magnetization current, the phenomenon of harmonics and power factor is evaluated by measuring the no-load current at three-phase transformer, with a high magnetic flux density imposed. Measurements were taken at each phase of the transformer core. The transformer is connected to a variable voltage variable frequency (VVVF) as a voltage source and the investigation carried out at various flux densities. The results showed that the magnetization current and harmonic phenomena increased significantly when the high magnetic flux density and vice versa injected with power factor declined sharply. This phenomenon can be used as an indication of saturation of the 3-phase transformer core. 展开更多
关键词 Core Saturation Magnetization current harmonic
在线阅读 下载PDF
A new model analysis of the third harmonic voltage in inductive measurement for critical current density of superconducting films*
15
作者 Zhang Xu Wu Zhi-Zhen Zhou Tie-Ge He Ming Zhao Xin-Jie Yan Shao-Lin Fang Lan 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期471-477,共7页
The critical current density Jc is one of the most important parameters of high temperature superconducting films in superconducting applications, such as superconducting filter and superconducting Josephson devices. ... The critical current density Jc is one of the most important parameters of high temperature superconducting films in superconducting applications, such as superconducting filter and superconducting Josephson devices. This paper presents a new model to describe inhomogeneous current distribution throughout the thickness of superconducting films applying magnetic field by solving the differential equation derived from Maxwell equation and the second London equation. Using this model, it accurately calculates the inductive third-harmonic voltage when the film applying magnetic field with the inductive measurement for Jc. The theoretic curve is consistent with the experimental results about measuring superconducting film, especially when the third-harmonic voltage just exceeds zero. The Jc value of superconducting films determined by the inductive method is also compared with results raeasured by four-probe transport method. The agreements between inductive method and transport method are very good. 展开更多
关键词 inhomogeneous current third-harmonic voltage critical current density magnetic field
原文传递
Electric Potential in a Dielectric Sphere Head Produced by a Time-Harmonic Equivalent Current Dipole
16
作者 Xiao-Yong Duan Shi-Zheng Peng Long-Wu Li Xiao-Chun Liu Rong Xin 《Journal of Electronic Science and Technology of China》 2007年第3期268-271,共4页
A time-harmonic equivalent current dipole model is proposed to simulate EEG source which deals with the problem concerning the capacitance effect. The expressions of potentials in both homogeneous infinite dielectric ... A time-harmonic equivalent current dipole model is proposed to simulate EEG source which deals with the problem concerning the capacitance effect. The expressions of potentials in both homogeneous infinite dielectric medium and dielectric sphere on the electroquasistatic condition are presented. The potential in a 3-layer inhomogeneous spherical head is computed by using this model. The influences on potential produced by time-harmonic character and permittivity are discussed. The results show that potentials in dielectric sphere are affected by frequency and permittivity. 展开更多
关键词 Electroquasistatic FREQUENCY PERMITTIVITY time-harmonic equivalent current dipole timeharmonic factor.
在线阅读 下载PDF
Rectifier Configurations Based on Harmonic Injecting and Counteracting Principle
17
作者 何丹 戴先中 +1 位作者 肖仁良 徐以荣 《Journal of Southeast University(English Edition)》 EI CAS 1999年第1期81-88,共8页
On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper pr... On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper presents two simpler single phase diode bridge rectifier configurations and their alternatives which can achieve low supply line current THD(total harmonic distortion) too. Moreover, this paper also proposes a few passive hamonic counteracting networks for multi single phase rectifiers which are connected in parallel. 展开更多
关键词 single phase rectifier harmonic compensation current injection THD
在线阅读 下载PDF
The Resonance Suppression for Parallel Photovoltaic Grid-connected Inverters in Weak Grid 被引量:6
18
作者 Qiu-Xia Yang Kun Li +1 位作者 Cui-Mei Zhao Hu Wang 《International Journal of Automation and computing》 EI CSCD 2018年第6期716-727,共12页
Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o... Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method. 展开更多
关键词 Parallel photovoltaic grid-connected inverters weak grid grid impedance resonance peak branch voltage and current double feedback.
原文传递
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter 被引量:1
19
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
在线阅读 下载PDF
Simulation of a kind of active harmonic reduction 18-pulse rectifier 被引量:1
20
作者 CHEN Xiao-qiang ZHAO Shou-wang WANG Ying 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第2期160-168,共9页
To solve the input current harmonic pollution of the high power rectifier system,18-pulse rectifier based on a kind of active harmonic suppression technique at dc side is proposed in this paper.The pulse rectifier emp... To solve the input current harmonic pollution of the high power rectifier system,18-pulse rectifier based on a kind of active harmonic suppression technique at dc side is proposed in this paper.The pulse rectifier employs three-phase diode bridges,each of them followed by a boost converter.Unlike the conventional three-phase unity-power-factor diode rectifier,the ideal sinusoidal main currents of circuit topology are obtained by control its output current or input currents of three boost converters for approximately triangular modulation.The theoretical of modulation strategy and characteristics of input and output currents about the proposed rectifier are analyzed in detail.Simulation results by Matlab/Simulink demonstrate that the proposed rectifier draws nearly sinusoidal current and power quality index is improved.The correctness of the theoretical analysis is validated. 展开更多
关键词 18-pulse rectifier active harmonic suppression three-phase unity-power-factor sinusoidal current topology
在线阅读 下载PDF
上一页 1 2 169 下一页 到第