This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar elect...This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar electricity delivered to grid is verified with the results from a computer simulation package (PVSYST) by adopting the installed component specifications, operation conditions, and weather data of the site. The results show high consistency between the values of energy delivered to the grid measured by the energy company and the energy estimated by system simulation. New system performance indicator is developed and called the optimum performance compliance ratio (PCR). It is a measure of the compliance of the output of the designed PV system with the output which would be produced by the same system with a solar tracker. This indicator provides system designers, contractors and energy providers with the actual capacity of the system that they can offer the end-users.展开更多
In this paper, the performance of grid connected PV system that is installed in Super Mega Factory is presented. The output parameters of 4 kW PV is collected and analyzed. Then, according to the results the weak poin...In this paper, the performance of grid connected PV system that is installed in Super Mega Factory is presented. The output parameters of 4 kW PV is collected and analyzed. Then, according to the results the weak points of the system were found and the theoretical output power was compared. After that we try to get the maximum output power making the correction of collector angle and place suitable panel position.展开更多
This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found i...This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found in the conventional DC-DC boost converter. The 3-phase grid connected converter with decoupling control give an independent control between active and reactive power using the load current feed-forward. With this technique, the disturbance rejection and the output power quality can be improved. Experiments are conducted with three case studies: 1) a test of the DIDB converter to determine current ripple and voltage gain, 2) a test of the 3-phase grid connected converter to determine DC-link voltage regulation, power factor and total harmonic distortion (THD), and 3) a test of the overall system with a 7.5 kW wind turbine simulator by step and various input wind speeds to determine the output power at the grid side and verify the maximum peak power tracking (MPPT) performance. The results can confirm that the DIDB converter gives lower ripple current and higher voltage gain than the conventional converter. For the grid side, the 3-phase grid connected converter can regulate the DC-link with fast dynamic response to disturbance rejection and low overshoot while complying with the THD standard defined in IEEE 519-1992. In addition, the MPPT controller is able to achieve the maximum energy capture with the various input wind speeds.展开更多
In India most part receives 4 - 7 kWh of solar radiation per square meter per day with 200 - 250 sunny days in a year. Tamilnadu state also receives the highest annual radiation in India. In this paper, the grid conne...In India most part receives 4 - 7 kWh of solar radiation per square meter per day with 200 - 250 sunny days in a year. Tamilnadu state also receives the highest annual radiation in India. In this paper, the grid connected photovoltaic plant has a peak power of 80 KWp supplies electricity requirement of GRT IET campus during day time (7 hrs) and reduces load demand and generates useful data for future implementation of such PV plant projects in the Tamilnadu region. Photovoltaic plant was installed in April 2015, monitored during 6 months, and the performance ratio and the various power losses (power electronics, temperature, soiling, internal, network, grid availability and interconnection) were calculated. The PV plant supplied 64,182.86 KWh to the grid from April to September 2015, ranging from 11,510.900 to 10,200.9 kWh. The final yield ranged from 143.886 (h/d) to 127.51 (y/d), reference yield ranged from 201.6 (h/d) to 155.31 (h/d) and performance ratio ranged from 71.3% to 82.1%, for a duration of six months, it had given a performance ratio of 83.82%, system efficiency was 4.16% and the capacity factor of GRT IET Campus for six months was 18.26%. Payback period in years = 9 years 4 months, energy saving per year = 204,400 KWh, cost reduction per year = 1,737,400, Indian rupee = 26,197.30 USD and total CO<sub>2</sub> reductions per year = 102,200 tons CO<sub>2</sub>/year.展开更多
To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which rel...To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis.展开更多
The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid reg...The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid regulation,using the traditional control mode with low accuracy can result in excess grid-connected impulse current and junction voltage.This occurs because the CAES output voltage does not match the frequency,amplitude,and phase of the power grid voltage.Therefore,an adaptive linear active disturbance-rejection control(A-LADRC)strategy was proposed.Based on the LADRC strategy,which is more accurate than the traditional proportional integral controller,the proposed controller is enhanced to allow adaptive adjustment of bandwidth parameters,resulting in improved accuracy and response speed.The problem of large impulse current when CAES is switched to the grid-connected mode is addressed,and the frequency fluctuation is reduced.Finally,the effectiveness of the proposed strategy in reducing the impact of CAES on the grid connection was verified using a hardware-in-the-loop simulation platform.The influence of the k value in the adaptive-adjustment formula on the A-LADRC was analyzed through simulation.The anti-interference performance of the control was verified by increasing and decreasing the load during the presynchronization process.展开更多
Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar...Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar photovol-taic(PV),as a source of electricity,has grown in popularity over the last few dec-ades because of their clean,noise-free,low-maintenance,and abundant availability of solar energy.There are two types of maximum power point track-ing(MPPT)techniques:classical and evolutionary algorithm-based techniques.Precise and less complex perturb and observe(P&O)and incremental conduc-tance(INC)approaches are extensively employed among classical techniques.This study used afield-programmable gate array(FPGA)-based hardware arrange-ment for a grid-connected photovoltaic(PV)system.The PV panels,MPPT con-trollers,and battery management systems are all components of the proposed system.In the developed hardware prototype,various modes of operation of the grid-connected PV system were examined using P&O and incremental con-ductance MPPT approaches.展开更多
In this work,we present a feasibility study for a new hybrid power plant(PV-Wind-Diesel-Storage)directly connected to the electrical grid.Several simulations are performed to verify the performance of the hybrid syste...In this work,we present a feasibility study for a new hybrid power plant(PV-Wind-Diesel-Storage)directly connected to the electrical grid.Several simulations are performed to verify the performance of the hybrid system under different scenarios using real meteorological data.It is shown that the performances of the hybrid system connected to the electrical network depend obviously on the available energy resources and constraints because the renewable energies are intermittent.In addition,the price of the kWh of electricity supplied by the hybrid system is determined,which amounts to$0.209/kWh,which is very cost effective and satisfactory for the considered sample conditions(Comoros Island).展开更多
The synchronous virtual machine uses inverter power to imitate the performance of the conventional synchronous machine.It also has the same inertia,damping,frequency,voltage regulation,and other external performance a...The synchronous virtual machine uses inverter power to imitate the performance of the conventional synchronous machine.It also has the same inertia,damping,frequency,voltage regulation,and other external performance as the generator.It is the key technology to realize new energy grid connections’stable and reliable operation.This project studies a dynamic simulation model of an extensive new energy power system based on the virtual synchronous motor.A new energy storage method is proposed.The mathematical energy storage model is established by combining the fixed rotor model of a synchronous virtual machine with the charge-discharge power,state of charge,operation efficiency,dead zone,and inverter constraint.The rapid conversion of energy storage devices absorbs the excess instantaneous kinetic energy caused by interference.The branch transient of the critical cut set in the system can be confined to a limited area.Thus,the virtual synchronizer’s kinetic and potential energy can be efficiently converted into an instantaneous state.The simulation of power system analysis software package(PSASP)verifies the correctness of the theory and algorithm in this paper.This paper provides a theoretical basis for improving the transient stability of new energy-connected power grids.展开更多
In order to ease the fossil energy crunch,new energy sources need to be fully utilized.Clean energy sources such as wind,light,and nuclear energy are important tools to solve environmental and energy problems.However,...In order to ease the fossil energy crunch,new energy sources need to be fully utilized.Clean energy sources such as wind,light,and nuclear energy are important tools to solve environmental and energy problems.However,in the process of researching new energy farms,there are some problems when they are integrated into the power system.In order to ensure the stability of new energy power plants,it is necessary to conduct an in-depth analysis of the grid connection technology of new energy farms.In the study,it is necessary to learn about the specific problems of the stability of the grid connection of new energy power plants,and to clarify the specific application of the grid connection technology of new energy power plants from the application principle and advantages of the grid connection technology of new energy power plants.Through simulation experiments,the positive effect of grid connection technology of new energy power plants in improving the stability of power systems was determined.展开更多
In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is rel...In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is relatively simple. Thus, connecting large-capacity wind power units complicates the peak load regulation and stable operation of the power grids in these regions. Most wind turbines use power electronic converter technology, which affects the safety and stability of the power grid differently compared with conventional synchronous generators. Furthermore, fluctuations in wind power cause fluctuations in the output of wind farms, making it difficult to create and implement suitable power generation plans for wind farms. The generation technology and grid connection scheme for wind power and conventional thermal power generation differ considerably. Moreover, the active and reactive power control abilities of wind turbines are weaker than those of thermal power units, necessitating additional equipment to control wind turbines. Hence, to address the aforementioned issues with large-scale wind power generation, this study analyzes the differences between the grid connection and collection strategies for wind power bases and thermal power plants. Based on this analysis, the differences in the power control modes of wind power and thermal power are further investigated. Finally, the stability of different control modes is analyzed through simulation. The findings can be beneficial for the planning and development of large-scale wind power generation farms.展开更多
PV plants are increasing all over the world and they are becoming a distinct part of electric grids.Due to abundance of solar irradiation and almost constant amount of it in certain geographical latitudes,selection of...PV plants are increasing all over the world and they are becoming a distinct part of electric grids.Due to abundance of solar irradiation and almost constant amount of it in certain geographical latitudes,selection of proper capacity of PV plants depends mostly on available places for the site.In this paper,important measures for safe connection of a PV plant in terms of voltage requirements are addressed and several guidelines are introduced for this purpose.In addition,simulation results are included to prove some of the mentioned suggestions.A general algorithm is fi nally proposed to show the directions for safe connection of PV plants.展开更多
Solar power generation is of environmental significance and will not be affected by the energy crisis and the instability of the fuel market. Solar photovoltaic power generation has no moving parts and the installatio...Solar power generation is of environmental significance and will not be affected by the energy crisis and the instability of the fuel market. Solar photovoltaic power generation has no moving parts and the installation and maintenance work is simple. To transmit the electricity provided by solar energy to our daily life, we need to connect with the power grid by grid connection. In order to improve the supervision of various equipment parameters in the process of grid connection, modeling is crucial. This paper firstly gives an overview of grid connected photovoltaic power generation system. Based on the various components of the system, the grid connected photovoltaic modeling research is conducted through solar photovoltaic cell arrays.展开更多
This first quarter of the 21st century is increasingly marked by population growth,digital and industrial developments,a growing need for electricity supply,and climate change.All these,to name just a few,have made th...This first quarter of the 21st century is increasingly marked by population growth,digital and industrial developments,a growing need for electricity supply,and climate change.All these,to name just a few,have made the establishment of a stable,flexible,controlled,well-designed,extensive,and clean power system a necessity.Consequently,distributed microgrid generation based on alternative/renewable energies and/or low-carbon technologies has emerged.In this paper,we study the modeling,the control,and the power management strategy of a grid-connected hybrid alternating/direct current(AC/DC)microgrid based on a wind turbine generation system using a doubly fed induction generator,a photovoltaic generation system,and storage elements including hydrogen storage system and batteries.Adequate modeling is described,and the overall system monitoring is presented and applied to manage appropri-ate power sharing and to control active and reactive powers,in order to match load and weather fluctuation behavior.Simulations are carried out using a MATLAB/Simulink simulation tool.Simulations reveal convenient results in terms of the bidirectional interlinking converter capabilities regarding power balance establishment between the two subgrids,reactive power compensation to ensure a unity power factor,and DC-bus voltage regulation at 1200 V.In addition,the primary and secondary controls are approved for each distributed generation of the studied system to attain the assigned power references,regardless of whether the subgrid is heavily or lightly loaded throughout the four considered case studies,showing satisfactory tracking and interacting performances,and thus stimulating a stable system implementation.展开更多
The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid moderniz...The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems.展开更多
In this paper the operation of a three level H-bridge converter as well as its parallel operations is analyzed and simulated on the computer. Based on the simulation results the operating behavior between (a) a thre...In this paper the operation of a three level H-bridge converter as well as its parallel operations is analyzed and simulated on the computer. Based on the simulation results the operating behavior between (a) a three level H-bridge neutral point clamped convener, (b) a three level back-to-back H-bridge neutral point clamped convener, (c) two three level H-bridge neutral point clamped converters parallel connected is being compared. From the simulation results it is obvious that in the first two cases the ripples, the distortion in primary and secondary winding currents, and the power factor are quite satisfactory and almost identical to each other. In the third case as compared with the first two, it is observed that current harmonics with higher amplitude appear in the primary winding of the transformer.展开更多
For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of th...For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.展开更多
Transformerless grid-connected inverters offer greater efficiencies when transferring power from renewable energy sources to the electrical grid.If the grid-inverter connection is done with an LCL filter,high attenuat...Transformerless grid-connected inverters offer greater efficiencies when transferring power from renewable energy sources to the electrical grid.If the grid-inverter connection is done with an LCL filter,high attenuation of switching harmonics is achieved while preserving a small-size output filter.However,damping must be included in the controller to assure closed-loop stability.This paper proposes a reference computation methodology for the inverter-side current feedback in a photovoltaic(PV)generation system connected to the grid through an LCL filter.Theoretical analysis of the closed-loop system stability and of the steady-state performance are presented as well as experimental validation of the closed-loop performance.The feedback controller includes active damping and relies on a resonant control structure which improves the ability of dealing with grid harmonic distortion.The controller uses a reduced set of measurements,which requires the inverter-side current and grid voltage only,and assures a power factor close to unity.展开更多
智能电网的发展需要与之相适应的测试能力,测试环境将成为智能电网突破性发展的核心推动力。通过梳理美国智能电网测试环境的案例,分析了美国智能电网测试环境发展的特点,研究了美国国家标准技术研究院(National Institute of Standards...智能电网的发展需要与之相适应的测试能力,测试环境将成为智能电网突破性发展的核心推动力。通过梳理美国智能电网测试环境的案例,分析了美国智能电网测试环境发展的特点,研究了美国国家标准技术研究院(National Institute of Standards and Technology,NIST)提出的发展机遇和发展思路,总结分析了美国智能电网测试环境提升发展的行动策略以及给我们的启示。NIST和能源部(Department of Energy,DOE)的协调和引领、研究机构资源和能力的协同、公共基础资源的共享和远程访问,形成了美国智能电网测试环境发展的合力。智能电网测试环境的发展,应以满足智能电网发展需要为出发点,以模块化、互联互通为发展方向。共享和远程开放需作为信息物理融合系统(cyber physic system,CPS)基础性和独特性测试资源建设的重要原则。系统模型、仿真工具和测试数据的积累和使用也需要整体协调、有序推进和充分共享。展开更多
Photovoltaic power(PV)is integrated into the grid through power inverters.But the inverters lead PV to lose some of the characteristics of conventional power sources that are conducive to grid stability,such as reduce...Photovoltaic power(PV)is integrated into the grid through power inverters.But the inverters lead PV to lose some of the characteristics of conventional power sources that are conducive to grid stability,such as reduced inertia,reactive power regulation capability,and fault ride-through capability.After introducing the power angle characteristics of a motor-generator pair(MGP)and reviewing MGP’s existing control methods and PV’s characteristics,this paper proposes a DC voltage feedback control method that can make MGP follow the fluctuations of a PV source.The proposal is studied experimentally,with the following results:(1)An MGP system can follow the power fluctuation of PV by using a DC voltage feedback control method.(2)Such feedback enables the PV to have a self-synchronization characteristic,which enables PV to actively contribute to the stability of the grid.展开更多
文摘This paper assesses 4 years of operation of a 1.75 kW roof top solar PV system installed in a Sydney suburban house. The system consists of 10 PV panels, a DC/AC inverter, and a grid connected gross meter. Solar electricity delivered to grid is verified with the results from a computer simulation package (PVSYST) by adopting the installed component specifications, operation conditions, and weather data of the site. The results show high consistency between the values of energy delivered to the grid measured by the energy company and the energy estimated by system simulation. New system performance indicator is developed and called the optimum performance compliance ratio (PCR). It is a measure of the compliance of the output of the designed PV system with the output which would be produced by the same system with a solar tracker. This indicator provides system designers, contractors and energy providers with the actual capacity of the system that they can offer the end-users.
文摘In this paper, the performance of grid connected PV system that is installed in Super Mega Factory is presented. The output parameters of 4 kW PV is collected and analyzed. Then, according to the results the weak points of the system were found and the theoretical output power was compared. After that we try to get the maximum output power making the correction of collector angle and place suitable panel position.
文摘This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found in the conventional DC-DC boost converter. The 3-phase grid connected converter with decoupling control give an independent control between active and reactive power using the load current feed-forward. With this technique, the disturbance rejection and the output power quality can be improved. Experiments are conducted with three case studies: 1) a test of the DIDB converter to determine current ripple and voltage gain, 2) a test of the 3-phase grid connected converter to determine DC-link voltage regulation, power factor and total harmonic distortion (THD), and 3) a test of the overall system with a 7.5 kW wind turbine simulator by step and various input wind speeds to determine the output power at the grid side and verify the maximum peak power tracking (MPPT) performance. The results can confirm that the DIDB converter gives lower ripple current and higher voltage gain than the conventional converter. For the grid side, the 3-phase grid connected converter can regulate the DC-link with fast dynamic response to disturbance rejection and low overshoot while complying with the THD standard defined in IEEE 519-1992. In addition, the MPPT controller is able to achieve the maximum energy capture with the various input wind speeds.
文摘In India most part receives 4 - 7 kWh of solar radiation per square meter per day with 200 - 250 sunny days in a year. Tamilnadu state also receives the highest annual radiation in India. In this paper, the grid connected photovoltaic plant has a peak power of 80 KWp supplies electricity requirement of GRT IET campus during day time (7 hrs) and reduces load demand and generates useful data for future implementation of such PV plant projects in the Tamilnadu region. Photovoltaic plant was installed in April 2015, monitored during 6 months, and the performance ratio and the various power losses (power electronics, temperature, soiling, internal, network, grid availability and interconnection) were calculated. The PV plant supplied 64,182.86 KWh to the grid from April to September 2015, ranging from 11,510.900 to 10,200.9 kWh. The final yield ranged from 143.886 (h/d) to 127.51 (y/d), reference yield ranged from 201.6 (h/d) to 155.31 (h/d) and performance ratio ranged from 71.3% to 82.1%, for a duration of six months, it had given a performance ratio of 83.82%, system efficiency was 4.16% and the capacity factor of GRT IET Campus for six months was 18.26%. Payback period in years = 9 years 4 months, energy saving per year = 204,400 KWh, cost reduction per year = 1,737,400, Indian rupee = 26,197.30 USD and total CO<sub>2</sub> reductions per year = 102,200 tons CO<sub>2</sub>/year.
基金supported by Science and Technology Projects of Jiangsu Province(No.BE2022003)Science and Technology Projects of Jiangsu Province(No.BE2022003-5).
文摘To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis.
基金supported by National Natural Science Foundation of China(Project No.52077079).
文摘The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid regulation,using the traditional control mode with low accuracy can result in excess grid-connected impulse current and junction voltage.This occurs because the CAES output voltage does not match the frequency,amplitude,and phase of the power grid voltage.Therefore,an adaptive linear active disturbance-rejection control(A-LADRC)strategy was proposed.Based on the LADRC strategy,which is more accurate than the traditional proportional integral controller,the proposed controller is enhanced to allow adaptive adjustment of bandwidth parameters,resulting in improved accuracy and response speed.The problem of large impulse current when CAES is switched to the grid-connected mode is addressed,and the frequency fluctuation is reduced.Finally,the effectiveness of the proposed strategy in reducing the impact of CAES on the grid connection was verified using a hardware-in-the-loop simulation platform.The influence of the k value in the adaptive-adjustment formula on the A-LADRC was analyzed through simulation.The anti-interference performance of the control was verified by increasing and decreasing the load during the presynchronization process.
文摘Global energy demand is growing rapidly owing to industrial growth and urbanization.Alternative energy sources are driven by limited reserves and rapid depletion of conventional energy sources(e.g.,fossil fuels).Solar photovol-taic(PV),as a source of electricity,has grown in popularity over the last few dec-ades because of their clean,noise-free,low-maintenance,and abundant availability of solar energy.There are two types of maximum power point track-ing(MPPT)techniques:classical and evolutionary algorithm-based techniques.Precise and less complex perturb and observe(P&O)and incremental conduc-tance(INC)approaches are extensively employed among classical techniques.This study used afield-programmable gate array(FPGA)-based hardware arrange-ment for a grid-connected photovoltaic(PV)system.The PV panels,MPPT con-trollers,and battery management systems are all components of the proposed system.In the developed hardware prototype,various modes of operation of the grid-connected PV system were examined using P&O and incremental con-ductance MPPT approaches.
文摘In this work,we present a feasibility study for a new hybrid power plant(PV-Wind-Diesel-Storage)directly connected to the electrical grid.Several simulations are performed to verify the performance of the hybrid system under different scenarios using real meteorological data.It is shown that the performances of the hybrid system connected to the electrical network depend obviously on the available energy resources and constraints because the renewable energies are intermittent.In addition,the price of the kWh of electricity supplied by the hybrid system is determined,which amounts to$0.209/kWh,which is very cost effective and satisfactory for the considered sample conditions(Comoros Island).
文摘The synchronous virtual machine uses inverter power to imitate the performance of the conventional synchronous machine.It also has the same inertia,damping,frequency,voltage regulation,and other external performance as the generator.It is the key technology to realize new energy grid connections’stable and reliable operation.This project studies a dynamic simulation model of an extensive new energy power system based on the virtual synchronous motor.A new energy storage method is proposed.The mathematical energy storage model is established by combining the fixed rotor model of a synchronous virtual machine with the charge-discharge power,state of charge,operation efficiency,dead zone,and inverter constraint.The rapid conversion of energy storage devices absorbs the excess instantaneous kinetic energy caused by interference.The branch transient of the critical cut set in the system can be confined to a limited area.Thus,the virtual synchronizer’s kinetic and potential energy can be efficiently converted into an instantaneous state.The simulation of power system analysis software package(PSASP)verifies the correctness of the theory and algorithm in this paper.This paper provides a theoretical basis for improving the transient stability of new energy-connected power grids.
文摘In order to ease the fossil energy crunch,new energy sources need to be fully utilized.Clean energy sources such as wind,light,and nuclear energy are important tools to solve environmental and energy problems.However,in the process of researching new energy farms,there are some problems when they are integrated into the power system.In order to ensure the stability of new energy power plants,it is necessary to conduct an in-depth analysis of the grid connection technology of new energy farms.In the study,it is necessary to learn about the specific problems of the stability of the grid connection of new energy power plants,and to clarify the specific application of the grid connection technology of new energy power plants from the application principle and advantages of the grid connection technology of new energy power plants.Through simulation experiments,the positive effect of grid connection technology of new energy power plants in improving the stability of power systems was determined.
基金This work was supported by National Key Research and Development Program of China(2018YFB0904000).
文摘In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is relatively simple. Thus, connecting large-capacity wind power units complicates the peak load regulation and stable operation of the power grids in these regions. Most wind turbines use power electronic converter technology, which affects the safety and stability of the power grid differently compared with conventional synchronous generators. Furthermore, fluctuations in wind power cause fluctuations in the output of wind farms, making it difficult to create and implement suitable power generation plans for wind farms. The generation technology and grid connection scheme for wind power and conventional thermal power generation differ considerably. Moreover, the active and reactive power control abilities of wind turbines are weaker than those of thermal power units, necessitating additional equipment to control wind turbines. Hence, to address the aforementioned issues with large-scale wind power generation, this study analyzes the differences between the grid connection and collection strategies for wind power bases and thermal power plants. Based on this analysis, the differences in the power control modes of wind power and thermal power are further investigated. Finally, the stability of different control modes is analyzed through simulation. The findings can be beneficial for the planning and development of large-scale wind power generation farms.
文摘PV plants are increasing all over the world and they are becoming a distinct part of electric grids.Due to abundance of solar irradiation and almost constant amount of it in certain geographical latitudes,selection of proper capacity of PV plants depends mostly on available places for the site.In this paper,important measures for safe connection of a PV plant in terms of voltage requirements are addressed and several guidelines are introduced for this purpose.In addition,simulation results are included to prove some of the mentioned suggestions.A general algorithm is fi nally proposed to show the directions for safe connection of PV plants.
文摘Solar power generation is of environmental significance and will not be affected by the energy crisis and the instability of the fuel market. Solar photovoltaic power generation has no moving parts and the installation and maintenance work is simple. To transmit the electricity provided by solar energy to our daily life, we need to connect with the power grid by grid connection. In order to improve the supervision of various equipment parameters in the process of grid connection, modeling is crucial. This paper firstly gives an overview of grid connected photovoltaic power generation system. Based on the various components of the system, the grid connected photovoltaic modeling research is conducted through solar photovoltaic cell arrays.
文摘This first quarter of the 21st century is increasingly marked by population growth,digital and industrial developments,a growing need for electricity supply,and climate change.All these,to name just a few,have made the establishment of a stable,flexible,controlled,well-designed,extensive,and clean power system a necessity.Consequently,distributed microgrid generation based on alternative/renewable energies and/or low-carbon technologies has emerged.In this paper,we study the modeling,the control,and the power management strategy of a grid-connected hybrid alternating/direct current(AC/DC)microgrid based on a wind turbine generation system using a doubly fed induction generator,a photovoltaic generation system,and storage elements including hydrogen storage system and batteries.Adequate modeling is described,and the overall system monitoring is presented and applied to manage appropri-ate power sharing and to control active and reactive powers,in order to match load and weather fluctuation behavior.Simulations are carried out using a MATLAB/Simulink simulation tool.Simulations reveal convenient results in terms of the bidirectional interlinking converter capabilities regarding power balance establishment between the two subgrids,reactive power compensation to ensure a unity power factor,and DC-bus voltage regulation at 1200 V.In addition,the primary and secondary controls are approved for each distributed generation of the studied system to attain the assigned power references,regardless of whether the subgrid is heavily or lightly loaded throughout the four considered case studies,showing satisfactory tracking and interacting performances,and thus stimulating a stable system implementation.
文摘The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems.
文摘In this paper the operation of a three level H-bridge converter as well as its parallel operations is analyzed and simulated on the computer. Based on the simulation results the operating behavior between (a) a three level H-bridge neutral point clamped convener, (b) a three level back-to-back H-bridge neutral point clamped convener, (c) two three level H-bridge neutral point clamped converters parallel connected is being compared. From the simulation results it is obvious that in the first two cases the ripples, the distortion in primary and secondary winding currents, and the power factor are quite satisfactory and almost identical to each other. In the third case as compared with the first two, it is observed that current harmonics with higher amplitude appear in the primary winding of the transformer.
文摘For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.
文摘Transformerless grid-connected inverters offer greater efficiencies when transferring power from renewable energy sources to the electrical grid.If the grid-inverter connection is done with an LCL filter,high attenuation of switching harmonics is achieved while preserving a small-size output filter.However,damping must be included in the controller to assure closed-loop stability.This paper proposes a reference computation methodology for the inverter-side current feedback in a photovoltaic(PV)generation system connected to the grid through an LCL filter.Theoretical analysis of the closed-loop system stability and of the steady-state performance are presented as well as experimental validation of the closed-loop performance.The feedback controller includes active damping and relies on a resonant control structure which improves the ability of dealing with grid harmonic distortion.The controller uses a reduced set of measurements,which requires the inverter-side current and grid voltage only,and assures a power factor close to unity.
文摘智能电网的发展需要与之相适应的测试能力,测试环境将成为智能电网突破性发展的核心推动力。通过梳理美国智能电网测试环境的案例,分析了美国智能电网测试环境发展的特点,研究了美国国家标准技术研究院(National Institute of Standards and Technology,NIST)提出的发展机遇和发展思路,总结分析了美国智能电网测试环境提升发展的行动策略以及给我们的启示。NIST和能源部(Department of Energy,DOE)的协调和引领、研究机构资源和能力的协同、公共基础资源的共享和远程访问,形成了美国智能电网测试环境发展的合力。智能电网测试环境的发展,应以满足智能电网发展需要为出发点,以模块化、互联互通为发展方向。共享和远程开放需作为信息物理融合系统(cyber physic system,CPS)基础性和独特性测试资源建设的重要原则。系统模型、仿真工具和测试数据的积累和使用也需要整体协调、有序推进和充分共享。
基金supported in part by the Science and Technology Project of State Grid Corporation of China:Researches on the generation control system and operation strategies of the power grid with a super high proportion of new energy generations。
文摘Photovoltaic power(PV)is integrated into the grid through power inverters.But the inverters lead PV to lose some of the characteristics of conventional power sources that are conducive to grid stability,such as reduced inertia,reactive power regulation capability,and fault ride-through capability.After introducing the power angle characteristics of a motor-generator pair(MGP)and reviewing MGP’s existing control methods and PV’s characteristics,this paper proposes a DC voltage feedback control method that can make MGP follow the fluctuations of a PV source.The proposal is studied experimentally,with the following results:(1)An MGP system can follow the power fluctuation of PV by using a DC voltage feedback control method.(2)Such feedback enables the PV to have a self-synchronization characteristic,which enables PV to actively contribute to the stability of the grid.