期刊文献+
共找到143篇文章
< 1 2 8 >
每页显示 20 50 100
A synthetic optically pumped gradiometer for magnetocardiography measurements 被引量:5
1
作者 Shu-Lin Zhang Ning Cao 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第4期215-217,共3页
Magnetocardiography(MCG)measurement is important for investigating the cardiac biological activities.Traditionally,the extremely weak MCG signal was detected by using superconducting quantum interference devices(SQUID... Magnetocardiography(MCG)measurement is important for investigating the cardiac biological activities.Traditionally,the extremely weak MCG signal was detected by using superconducting quantum interference devices(SQUIDs).As a room-temperature magnetic-field sensor,optically pumped magnetometer(OPM)has shown to have comparable sensitivity to that of SQUIDs,which is very suitable for biomagnetic measurements.In this paper,a synthetic gradiometer was constructed by using two OPMs under spin-exchange relaxation-free(SERF)conditions within a moderate magnetically shielded room(MSR).The magnetic noise of the OPM was measured to less than 70 fT/Hz1/2.Under a baseline of 100 mm,noise cancellation of about 30 dB was achieved.MCG was successfully measured with a signal to noise ratio(SNR)of about 37 dB.The synthetic gradiometer technique was very effective to suppress the residual environmental fields,demonstrating the OPM gradiometer technique for highly cost-effective biomagnetic measurements. 展开更多
关键词 optically PUMPED magnetometer(OPM) magnetocardiography(MCG) gradiometer
原文传递
A SQUID gradiometer module with large junction shunt resistors 被引量:1
2
作者 邱阳 刘超 +6 位作者 张树林 张国峰 王永良 李华 曾佳 孔祥燕 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第8期622-624,共3页
A dual-washer superconducting quantum interference device (SQUID) with a loop inductance of 350 pH and two on- washer integrated input coils is designed according to conventional niobium technology. In order to obta... A dual-washer superconducting quantum interference device (SQUID) with a loop inductance of 350 pH and two on- washer integrated input coils is designed according to conventional niobium technology. In order to obtain a large SQUID flux-to-voltage transfer coefficient, the junction shunt resistance is selected to be 33 Ω. A vertical SQUID gradiometer module with a baseline of 100 mm is constructed by utilizing such a SQUID and a first-order niobium wire-wound antenna. The sensitivity of this module reaches about 0.2 fT/(cm.Hz1/2) in the white noise range using a direct readout scheme, i.e., the SQUID is directly connected to an operational amplifier, in a magnetically shielded room. Some magnetocardiography (MCG) measurements with a sufficiently high signal-to-noise ratio (SNR) are demonstrated. 展开更多
关键词 SQUID gradiometer MAGNETOCARDIOGRAPHY
原文传递
Data processing method for aerial testing of rotating accelerometer gravity gradiometer 被引量:1
3
作者 QIAN Xuewu TANG Hailiang 《中国惯性技术学报》 EI CSCD 北大核心 2024年第8期743-752,共10页
A novel method for noise removal from the rotating accelerometer gravity gradiometer(MAGG)is presented.It introduces a head-to-tail data expansion technique based on the zero-phase filtering principle.A scheme for det... A novel method for noise removal from the rotating accelerometer gravity gradiometer(MAGG)is presented.It introduces a head-to-tail data expansion technique based on the zero-phase filtering principle.A scheme for determining band-pass filter parameters based on signal-to-noise ratio gain,smoothness index,and cross-correlation coefficient is designed using the Chebyshev optimal consistent approximation theory.Additionally,a wavelet denoising evaluation function is constructed,with the dmey wavelet basis function identified as most effective for processing gravity gradient data.The results of hard-in-the-loop simulation and prototype experiments show that the proposed processing method has shown a 14%improvement in the measurement variance of gravity gradient signals,and the measurement accuracy has reached within 4E,compared to other commonly used methods,which verifies that the proposed method effectively removes noise from the gradient signals,improved gravity gradiometry accuracy,and has certain technical insights for high-precision airborne gravity gradiometry. 展开更多
关键词 airborne gravity gradiometer data processing band-passing filter evaluation function
在线阅读 下载PDF
Baseline optimization of SQUID gradiometer for magnetocardiography
4
作者 李华 张树林 +4 位作者 邱阳 张永升 张朝祥 孔祥燕 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第2期471-473,共3页
SQUID gradiometer techniques are widely used in noise cancellation for biomagnetic measurements.An appropriate gradiometer baseline is very important for the biomagnetic detection with high performance.By placing seve... SQUID gradiometer techniques are widely used in noise cancellation for biomagnetic measurements.An appropriate gradiometer baseline is very important for the biomagnetic detection with high performance.By placing several magnetometers at different heights along the vertical direction,we could simultaneously obtain the synthetic gradiometers with different baselines.By using the traditional signal-to-noise ratio(SNR) as a performance index,we successfully obtain an optimal baseline for the magnetocardiography(MCG) measurement in a magnetically shielded room(MSR).Finally,we obtain an optimal baseline of 7 cm and use it for the practical MCG measurement in our MSR.The SNR about 38 dB is obtained in the recorded MCG signal. 展开更多
关键词 SQUID gradiometer baseline optimization MAGNETOCARDIOGRAPHY
原文传递
High-Tc planar SQUID gradiometer for eddy current non-destructive evaluation
5
作者 张鸣剑 郎佩琳 +3 位作者 彭智慧 陈莺飞 陈珂 郑东宁 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第8期1903-1908,共6页
This paper reports the fabrication and test of a high-Tc SQUID planar gradiometer which is patterned from YBCO thin film deposited on a SrTiO3 bicrystal substrate. The measurement of noise spectrum at 77K shows that t... This paper reports the fabrication and test of a high-Tc SQUID planar gradiometer which is patterned from YBCO thin film deposited on a SrTiO3 bicrystal substrate. The measurement of noise spectrum at 77K shows that the white noise at 200 Hz is about 1×10^-4 φ0/√Hz. The minimal magnetic gradient is measured and the results suggest that the minimal magnetic gradient is 94 pT/m. The planar gradiometer is used in non-destructive evaluation (NDE) experiments to detect the artifacts in conducting aluminium plates by performing eddy current testing in an unshielded environment. The effect of the exciting coil dimension on the NDE results is investigated. By mapping out the induced field distribution, flaws about 10mm below the plate surface can be clearly identified. 展开更多
关键词 SQUID planar gradiometer NDE
原文传递
Concept study of measuring gravitational constant using superconducting gravity gradiometer
6
作者 Xing Bian Ho Jung Paik Martin Vol Moody 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期130-135,共6页
Newton's gravitational constant G is the least known fundamental constant of nature. Since Cavendish made the first measurement of G with a torsion balance over two hundred years ago, the best results of G have been ... Newton's gravitational constant G is the least known fundamental constant of nature. Since Cavendish made the first measurement of G with a torsion balance over two hundred years ago, the best results of G have been obtained by using torsion balances. However, the uncorrected anelasticity of torsion fibers makes the results questionable. We present a new method of G measurement by using a superconducting gravity gradiometer constructed with levitated test masses, which is free from the irregularities of mechanical suspension. The superconducting gravity gradiometer is rotated to generate a centrifugal acceleration that nulls the gravity field of the source mass, forming an artificial planetary system. This experiment has a potential accuracy of G better than 10 ppm. 展开更多
关键词 gravitational constant superconducting gravity gradiometer artificial planetary system
原文传递
Optimization of pick-up coils for weakly damped SQUID gradiometers
7
作者 Kang Yang Jialei Wang +2 位作者 Xiangyan Kong Ruihu Yang Hua Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期137-142,共6页
The performance of a superconducting quantum interference device(SQUID)gradiometer is always determined by its pick-up coil geometry,such as baseline and radius.In this paper,based on the expressions for the coupled f... The performance of a superconducting quantum interference device(SQUID)gradiometer is always determined by its pick-up coil geometry,such as baseline and radius.In this paper,based on the expressions for the coupled flux threading a magnetometer obtained by Wikswo,we studied how the gradiometer performance parameters,including the current dipole sensitivity,spatial resolution and signal-to-noise ratio(SNR),are affected by its pick-up coil via Mat Lab simulation.Depending on the simulation results,the optimal pick-up coil design region for a certain gradiometer can be obtained.To verify the simulation results,we designed and fabricated several first-order gradiometers based on the weakly damped SQUID with different pick-up coils by applying superconducting connection.The experimental measurements were conducted on a simple current dipole in a magnetically shielding room.The measurement results are well in coincidence with the simulation ones,indicating that the simulation model is useful in specific pick-up coil design. 展开更多
关键词 superconducting quantum interference device(SQUID)gradiometer spatial resolution dipole sensitivity signal-to-noise ratio
原文传递
质子磁梯度仪设计及其灵敏度评估
8
作者 由德龙 张爽 +2 位作者 陈曙东 赵明欣 孟繁骏 《吉林大学学报(信息科学版)》 2025年第2期245-250,共6页
由于单一传感器的质子磁力仪极易受地磁日变、环境干扰等影响,为提高质子磁力仪测量精度,对传感器设计和系统性能评估进行了分析研究。首先,基于MAXWELL电磁仿真软件建立螺线管、柱形、环形以及“8”形线圈等4种传感器的仿真模型,对4种... 由于单一传感器的质子磁力仪极易受地磁日变、环境干扰等影响,为提高质子磁力仪测量精度,对传感器设计和系统性能评估进行了分析研究。首先,基于MAXWELL电磁仿真软件建立螺线管、柱形、环形以及“8”形线圈等4种传感器的仿真模型,对4种线圈的方向性、抗干扰能力等进行分析,最终确定以“8”形线圈作为传感器,构建质子磁梯度仪。其次,基于4阶差分与均方差算法分别对单路测量结果与差分测量结果进行评估,以分析磁梯度仪性能。实验结果表明,“8”形线圈传感器的初始信号信噪比可达40/1,磁力仪单路模式灵敏度可达0.054 nT,双路差分模式的灵敏度即使在强干扰条件下仍可达0.071 nT,为单路模式的√2倍。 展开更多
关键词 拉莫尔效应 质子磁梯度仪 灵敏度 传感器
在线阅读 下载PDF
Full magnetic gradient tensor from triaxial aeromagnetic gradient measurements:Calculation and application 被引量:6
9
作者 骆遥 吴美平 +4 位作者 王平 段树岭 刘浩军 王金龙 安战锋 《Applied Geophysics》 SCIE CSCD 2015年第3期283-291,465,共10页
The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mappin... The full magnetic gradient tensor (MGT) refers to the spatial change rate of the three field components of the geomagnetic field vector along three mutually orthogonal axes. The tensor is of use to geological mapping, resources exploration, magnetic navigation, and others. However, it is very difficult to measure the full magnetic tensor gradient using existing engineering technology. We present a method to use triaxial aeromagnetic gradient measurements for deriving the full MGT. The method uses the triaxial gradient data and makes full use of the variation of the magnetic anomaly modulus in three dimensions to obtain a self-consistent magnetic tensor gradient. Numerical simulations show that the full MGT data obtained with the proposed method are of high precision and satisfy the requirements of data processing. We selected triaxial aeromagnetic gradient data from the Hebei Province for calculating the full MGT. Data processing shows that using triaxial tensor gradient data allows to take advantage of the spatial rate of change of the total field in three dimensions and suppresses part of the independent noise in the aeromagnetic gradient. The calculated tensor components have improved resolution, and the transformed full tensor gradient satisfies the requirement of geological mapping and interpretation. 展开更多
关键词 Aeromagnetic gradient full magnetic gradient tensor triaxial aeromagnetic gradiometer. tensor invariant
在线阅读 下载PDF
Improved gravity field estimation by incorporating the Tiangong Space Station and next-generation CAI satellite gravity mission
10
作者 Renjie Zhao Qiujie Chen Xingfu Zhang 《Geodesy and Geodynamics》 2025年第2期183-192,共10页
The next-generation gravity satellite mission equipped with the Cold Atom Interferometry(CAI)gradiometer has great potential for the Earth's gravity field estimation.Deploying a CAI gradiometer on the Chinese Tian... The next-generation gravity satellite mission equipped with the Cold Atom Interferometry(CAI)gradiometer has great potential for the Earth's gravity field estimation.Deploying a CAI gradiometer on the Chinese Tiangong Space Station launched for long-term Earth science research not only reduces the cost compared to a dual-satellite constellation but also enhances interdisciplinary collaboration in the Earth's gravity field detection.In this study,we conducted gravity gradient-based simulations to assess the contribution of deploying a CAI gradiometer on the Tiangong Space Station to collaboratively observe the Earth's gravity field with a polar-orbit gravity satellite.The simulation results demonstrate that whether utilizing V_(yy) component,three diagonal components or full components,the derived gravity field models show significant improvements within 100 degree and above 200 degree after incorporating Tiangong Space Station.In particular,the gravity field solution recovered from three diagonal components achieves the best accuracy.In the case of using diagonal components,the collaboration observation scheme effectively reduced the cumulative geoid height error by approximately 5.3 cm(300 d/o).In the spatial domain,the incorporation of the Tiangong Space Station primarily impacts the estimated gravity field within the orbital coverage area of the space station,and this effect is particularly pronounced when just employing V_(yy) component.However,due to the limitation of angular velocity observation inaccuracy associated with the CAI gradiometer in nadir mode,there is no substantial accuracy improvement observed above 200 degree when adding gradient components. 展开更多
关键词 Satellite gravimetry CAl gradiometer Tiangong space station Gravity gradients simulation
原文传递
AGS-863航磁全轴梯度勘查系统关键性指标测试 被引量:29
11
作者 骆遥 段树岭 +3 位作者 王金龙 刘志强 梁韧 程怀德 《物探与化探》 CAS CSCD 北大核心 2011年第5期620-625,共6页
中国国土资源航空物探遥感中心成功研制出具有完全自主知识产权的AGS-863航磁全轴梯度勘查系统,并在内蒙古某地进行了航磁全轴梯度试生产。为配合航磁全轴梯度试生产,对系统设计的关键性指标予以实际测试,设计了相关试验,以验证AGS-863... 中国国土资源航空物探遥感中心成功研制出具有完全自主知识产权的AGS-863航磁全轴梯度勘查系统,并在内蒙古某地进行了航磁全轴梯度试生产。为配合航磁全轴梯度试生产,对系统设计的关键性指标予以实际测试,设计了相关试验,以验证AGS-863航磁全轴梯度勘查系统的稳定性与可靠性。测试结果表明系统具有非常好的同步特性、一致性和长期稳定性以及补偿精度。 展开更多
关键词 AGS-863航磁全轴梯度勘查系统 航磁梯度 系统的同步精度 系统的一致性 梯度补偿
在线阅读 下载PDF
航空重力梯度仪研究现状及发展趋势 被引量:22
12
作者 舒晴 周坚鑫 尹航 《物探与化探》 CAS CSCD 2007年第6期485-488,共4页
简要介绍了重力梯度仪的发展历程,重点叙述了旋转加速度计航空重力梯度仪的工作原理及研发过程,系统调研了航空重力梯度仪的仪器现状,跟踪了航空重力梯度仪的研究动态。
关键词 旋转加速度计重力梯度仪 航空重力梯度仪 SQUID OQR
在线阅读 下载PDF
国际卫星重力梯度测量计划研究进展 被引量:20
13
作者 郑伟 许厚泽 +3 位作者 钟敏 员美娟 周旭华 彭碧波 《测绘科学》 CSCD 北大核心 2010年第2期57-61,共5页
本文首先阐述了重力梯度测量原理、从20世纪初到21世纪初重力梯度仪的研究历程、卫星重力梯度仪(静电悬浮重力梯度仪、超导重力梯度仪和量子重力梯度仪)的技术特征以及卫星重力梯度测量的特点;其次,介绍了基于卫星重力梯度技术恢复250阶... 本文首先阐述了重力梯度测量原理、从20世纪初到21世纪初重力梯度仪的研究历程、卫星重力梯度仪(静电悬浮重力梯度仪、超导重力梯度仪和量子重力梯度仪)的技术特征以及卫星重力梯度测量的特点;其次,介绍了基于卫星重力梯度技术恢复250阶GOCE地球重力场以及论证首先开展一维径向重力梯度仪的研制进而恢复高精度和高空间解析度中高频地球重力场可行性方面的研究进展;最后,建议我国尽早开展基于时空域混合法解算中高频地球重力场和卫星重力梯度测量系统误差分析的预先研究。 展开更多
关键词 卫星重力梯度测量 重力梯度仪 GOCE 地球重力场 误差分析
原文传递
国外航空物探测量系统近年来若干进展 被引量:17
14
作者 高维 舒晴 +1 位作者 屈进红 米耀辉 《物探与化探》 CAS CSCD 2016年第6期1116-1124,共9页
航空物探测量作为一种高效的地球物理勘查技术方法,在地质调查、油气与固体矿产资源勘查等许多领域发挥着重要的作用,已成为开展国土资源调查及矿产资源潜力评价研究的重要技术手段。笔者较为系统地介绍了国内外航空磁力梯度测量系统、... 航空物探测量作为一种高效的地球物理勘查技术方法,在地质调查、油气与固体矿产资源勘查等许多领域发挥着重要的作用,已成为开展国土资源调查及矿产资源潜力评价研究的重要技术手段。笔者较为系统地介绍了国内外航空磁力梯度测量系统、航空电磁测量系统、航空伽马能谱测量系统、航空重力测量系统及配套测量技术的相关技术指标、研究现状与趋势以及应用领域。通过对比分析发现,该方法在国外已经发展的比较成熟,然而,在国内该项技术仍处于发展中,许多航空物探关键测量技术与国外相比仍存在较大的差距。因此,我国航空物探测量技术还需要加快发展。 展开更多
关键词 航空物探测量技术 航空磁力梯度系统 航空重力梯度系统
在线阅读 下载PDF
世界重力梯度仪的研究现状 被引量:19
15
作者 吴琼 滕云田 +1 位作者 张兵 张涛 《物探与化探》 CAS CSCD 2013年第5期761-768,共8页
在对地下结构的探测过程中,重力梯度仪器的研制及其科学的布设方式已经成了一个世界关注的研究课题。笔者介绍了目前世界上存在的基于扭矩和差分加速度计两种测量原理的重力梯度仪,并对其测量原理进行简要描述。然后对基于光学和原子干... 在对地下结构的探测过程中,重力梯度仪器的研制及其科学的布设方式已经成了一个世界关注的研究课题。笔者介绍了目前世界上存在的基于扭矩和差分加速度计两种测量原理的重力梯度仪,并对其测量原理进行简要描述。然后对基于光学和原子干涉重力梯度测量仪器进行描述,最后介绍了作者提出的重力梯度测量光路,为自主研发绝对重力梯度仪提供技术参考。 展开更多
关键词 重力梯度仪 扭矩平衡 激光干涉
在线阅读 下载PDF
海洋磁力仪的原理与技术指标对比分析 被引量:28
16
作者 裴彦良 梁瑞才 +2 位作者 刘晨光 韩国忠 李正光 《海洋科学》 CAS CSCD 北大核心 2005年第12期4-8,共5页
针对现今世界市场上海洋磁力仪产品型号较多、技术指标复杂、应用范围不尽相同,产品的选用存在一定困难等问题,分别介绍了3种不同类型的磁力仪的工作原理,具体对比分析了各种磁力仪的技术指标,并简单介绍了磁力仪的应用及梯度仪组合方... 针对现今世界市场上海洋磁力仪产品型号较多、技术指标复杂、应用范围不尽相同,产品的选用存在一定困难等问题,分别介绍了3种不同类型的磁力仪的工作原理,具体对比分析了各种磁力仪的技术指标,并简单介绍了磁力仪的应用及梯度仪组合方式。结果表明标准质子旋进式海洋磁力仪灵敏度较低,存在进向误差,但无死区,价格最为低廉,适合于对灵敏度要求不高的工程和科研地球物理调查。Overhauser海洋磁力仪的灵敏度高,无进向误差,无死区,价格便宜,适合于大多数工程和科研地球物理调查。光泵式海洋磁力仪灵敏度和采样率最高,梯度容忍度最大,但存在死区和进向误差问题,适用于高精度的海洋磁力梯度调查和航空磁力调查。分析结果显示:各种类型的磁力仪各有优势,具体选用应以具体情况而定。 展开更多
关键词 海洋磁力仪 梯度仪 质子旋进 Overhauser海洋磁力仪 光泵 技术指标
在线阅读 下载PDF
航空重力仪发展现状和趋势 被引量:34
17
作者 孙中苗 翟振和 李迎春 《地球物理学进展》 CSCD 北大核心 2013年第1期1-8,共8页
航空重力仪的持续发展使航空重力测量的分辨率和精度得以不断提高.本文较全面地介绍了国外多个型号航空重力标量测量仪的发展历程,比较分析了其主要技术指标和应用特点;同时简要介绍了国外航空重力梯度仪的现状和发展趋势,对我国航空重... 航空重力仪的持续发展使航空重力测量的分辨率和精度得以不断提高.本文较全面地介绍了国外多个型号航空重力标量测量仪的发展历程,比较分析了其主要技术指标和应用特点;同时简要介绍了国外航空重力梯度仪的现状和发展趋势,对我国航空重力仪的研制现状作了扼要评述. 展开更多
关键词 航空重力测量 空重力仪 航空重力梯度仪
在线阅读 下载PDF
基于协同克里金方法的重力梯度全张量三维约束反演 被引量:18
18
作者 耿美霞 黄大年 +1 位作者 于平 杨庆节 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2016年第5期1849-1860,共12页
随着重力梯度全张量测量技术的日趋成熟,重力梯度全张量数据的三维反演技术日益受到重视与关注.全张量数据反演与重力数据反演一样仍然面临着严重的多解性问题.本文将基于地质统计学的协同克里金方法应用于重力梯度全张量数据三维反演,... 随着重力梯度全张量测量技术的日趋成熟,重力梯度全张量数据的三维反演技术日益受到重视与关注.全张量数据反演与重力数据反演一样仍然面临着严重的多解性问题.本文将基于地质统计学的协同克里金方法应用于重力梯度全张量数据三维反演,建立了密度约束下的多变量协同克里金联合反演方程,以降低反演的多解性.模型试验表明密度信息的加入能够有效降低反演的多解性,提高反演结果的分辨率,尤其是纵向分辨率能够得到显著提高.最后对美国德克萨斯州一个岩丘区所获得实际资料的应用表明了本文方法的实用性. 展开更多
关键词 重力梯度全张量 三维约束反演 协同克里金方法 地质统计学
在线阅读 下载PDF
高精度石英挠性加速度计闭环系统的设计与分析 被引量:12
19
作者 刘润 蔡体菁 丁昊 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2010年第2期311-315,共5页
探讨了石英挠性加速度计的分辨率影响因素,提出了一种对现有石英挠性加速度计的改进设计.根据重力梯度测量对加速度计分辨率的要求,推导出摆片的固有频率,然后使用有限元方法重新设计加速度计的摆片结构.另外,为了降低加速度计的机械热... 探讨了石英挠性加速度计的分辨率影响因素,提出了一种对现有石英挠性加速度计的改进设计.根据重力梯度测量对加速度计分辨率的要求,推导出摆片的固有频率,然后使用有限元方法重新设计加速度计的摆片结构.另外,为了降低加速度计的机械热噪声,对表头抽真空,通过加入比例-微分环节对加速度计的控制回路进行阻尼补偿.计算出系统的开环传递函数,并对其进行动态性能仿真分析.分析结果表明:加速度计系统通过在系统前向通道添加比例微分环节能够补偿系统的阻尼,消除加速度计在固有频率处的振荡,使加速度计闭环后处于临界阻尼状态并保持系统的稳定性.改进后加速度计的系统带宽为515Hz,响应时间为3.7m s,分辨率达到10-10g,能够满足高精度测量的需要. 展开更多
关键词 石英挠性加速度计 分辨率 重力梯度
在线阅读 下载PDF
旋转加速度计重力梯度仪标度因子调整方法及误差补偿研究 被引量:10
20
作者 王树甫 孙枫 +1 位作者 郝燕玲 秦红磊 《中国惯性技术学报》 EI CSCD 2000年第4期31-34,45,共5页
在旋转加速度计重力梯度仪的重力梯度测量原理的基础上 ,本文提出了加速度计标度因子的在线调整方法。此方法对加速度计组合输出信号中的标度因子不平衡信息进行解调 ,通过反馈实现标度因子的调整 。
关键词 重力梯度仪 标度因子平衡 误差补偿 旋转加速度计 核潜艇 导航
在线阅读 下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部