Readout electronics for the gamma detector of the HIRFL-CSR external target facility
1
作者 Xian-Qin Li Hai-Bo Yang +10 位作者 Xiao-Meng Ma Chao-Jie Zou Tao Liu Xian-Cai Zhou Duo Yan Yang-Zhou Su Shu-Wen Tang Shi-Tao Wang Yu-Hong Yu Zhi-Yu Sun Cheng-Xin Zhao 《Nuclear Science and Techniques》 2025年第2期71-81,共11页
The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(... The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics. 展开更多
关键词 HIRFL-CSR gamma detector External target facility Readout electronics Readout control unit Common readout unit Peak-detection algorithm
在线阅读 下载PDF
Monte Carlo method for determining the response of portable gamma detector for in situ measurement of terrestrial gamma ray field
2
作者 Boubaker Askri 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第4期28-37,共10页
A Monte Carlo method to study the response of portable detector to terrestrial gamma ray is proposed. This method is based on two-stage Monte Carlo simulation.First, the probability distributions of the phase space co... A Monte Carlo method to study the response of portable detector to terrestrial gamma ray is proposed. This method is based on two-stage Monte Carlo simulation.First, the probability distributions of the phase space coordinates of the events that are most likely to be detected are reconstructed at the phase space shell level. The phase space shell is a closed surface enclosing the detector. The detector response to events originating from the phase space shell is then studied. The full absorption spectra as well as the partial absorption spectra are obtained for natural radionuclides uniformly distributed in the ground. For validation, this method is applied to a Hp Ge portable detector previously studied. The previous study is based on a semiempirical model. Good agreement is achieved when we compare the full-energy peak efficiencies and the total in situ spectra obtained by the two methods. As an application, the effective depth of the activity of the^(137) Cs artificial radionuclide in the soil is determined from the low-energy part of the total in situ spectrum. 展开更多
关键词 伽玛探测器 蒙特卡洛方法 便携式 地面 相空间重构 测量 线场 测定
在线阅读 下载PDF
Performance simulation and structure design of Binode CdZnTe gamma-ray detector 被引量:1
3
作者 牛莉博 李玉兰 +4 位作者 张岚 傅楗强 江灏 何彬 李元景 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第1期53-58,共6页
A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma ... A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma spectrum of the detector have been simulated and the detector structure has been optimized.In order to improve its performance further,Compton scattering effect correction has been used.The simulation results demonstrate that with refined design and Compton scattering effect correction,Binode CdZnTe detectors is capable of achieving 3.92%FWHM at 122 keV,and 1.27%FWHM at 662 keV.Compared with other single-polarity(electron-only) detector configurations,Binode CdZnTe detector offers a cost effective and simple structure alternative with comparable energy resolution. 展开更多
关键词 结构设计 性能模拟 检测器 阳极 ZNTE 碲锌镉探测器 Γ射线 CD
在线阅读 下载PDF
Method for converting in-situ gamma ray spectra of a portable Ge detector to an incident photon flux energy distribution based on Monte Carlo simulation 被引量:3
4
作者 Boubaker ASKRI Adel TRABELSI Brahim BACCARI 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第6期358-364,共7页
A matrix stripping method for the conversion of in-situ gamma ray spectrum, obtained with portable Ge detector, to photon flux energy distribution is proposed. The detector response is fully described by its stripping... A matrix stripping method for the conversion of in-situ gamma ray spectrum, obtained with portable Ge detector, to photon flux energy distribution is proposed. The detector response is fully described by its stripping matrix and full absorption efficiency curve. A charge collection efficiency function is introduced in the simulation to take into account the existence of a transition zone of increasing charge collection after the inactive Ge layer. Good agreement is obtained between simulated and experimental full absorption efficiencies. The characteristic stripping matrix is determined by Monte Carlo simulation for different incident photon energies using the Geant4 toolkit system. The photon flux energy distribution is deduced by stripping the measured spectrum of the partial absorption and cosmic ray events and then applying the full absorption efficiency curve. The stripping method is applied to a measured in-situ spectrum. The value of the absorbed dose rate in air deduced from the corresponding flux energy distribution agrees well with the value measured directly in-situ. 展开更多
关键词 蒙特卡罗模拟 探测器 伽马射线 拆模仿式
在线阅读 下载PDF
Geant4 analysis and optimization of a double crystal phoswich detector for beta–gamma coincidence detection 被引量:2
5
作者 Xing Fan Xian-Peng Zhang +1 位作者 Geng Tian Chao-Wen Yang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第4期92-97,共6页
In this study, a novel phoswich detector for beta–gamma coincidence detection is designed. Unlike the triple crystal phoswich detector designed by researchers at the University of Missouri, Columbia, this phoswich de... In this study, a novel phoswich detector for beta–gamma coincidence detection is designed. Unlike the triple crystal phoswich detector designed by researchers at the University of Missouri, Columbia, this phoswich detector is of the semi-well type, so it has a higher detection efficiency. The detector consists of BC-400 and NaI:Tl with decay time constants of 2.4 and 230 ns, respectively.The BC-400 scintillator detects beta particles, and the Na I:Tl cell is used for gamma detection. Geant4 simulations of this phoswich detector find that a 2-mm-thick BC-400 scintillator can absorb nearly all of the beta particles whose energies are below 700 keV. Further, for a 2.00-cmthick NaI:Tl crystal, the gamma source peak efficiency for photons ranges from a maximum of nearly 90% at 30 keV to 10% at 1 MeV. The self-absorption effect is also discussed in this paper in order to determine the carrier gas' s influence. 展开更多
关键词 GEANT4 PHOSWICH detector Beta–gamma COINCIDENCE DETECTION DETECTION efficiency
在线阅读 下载PDF
Design and gamma sensitivity measurement of a novel dual-emitter vacuum Compton detector 被引量:1
6
作者 韩和同 王群书 +2 位作者 夏良斌 管兴胤 张子川 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第11期4777-4780,共4页
A novel dual-emitter vacuum Compton detector (D-VCD) with higher gamma ray detecting efficiency is proposed. The emitters are made of Ta A1 clad metal. The gamma ray sensitivity is studied by Monte Carlo simulation ... A novel dual-emitter vacuum Compton detector (D-VCD) with higher gamma ray detecting efficiency is proposed. The emitters are made of Ta A1 clad metal. The gamma ray sensitivity is studied by Monte Carlo simulation using the MCNP code. A comparison between calculations and results measured by using the 1.25 MeV gamma ray of Co-60 is also performed. Experimental sensitivities for two sample D-VCDs with the same materials and structures are 1.92×10^-20 and 2.02×10^-20·cm^2/MeV separately, which are consistent with the simulation result of 1.98×10^-20·cm^2/MeV and are 4 times higher than that of VCD with a single Fe emitter. According to the simulation results, in a gamma energy range from 0.5 to 3 MeV, the maximum sensitivity variance for the D-VCD is less than 15%, and less than 5% in a range from 1 to 2 MeV in particular. The novel D-VCD is applicable to the detection of intense pulse gamma rays. 展开更多
关键词 vacuum Compton detector sensitivity pulsed gamma ray
原文传递
Microstructural Investigation of PM-355 Nuclear Track Detector Subjected to Low-Dose Gamma Irradiation: A Positron Annihilation Lifetime Study 被引量:1
7
作者 Emad Hassan Aly 《Materials Sciences and Applications》 2013年第10期622-629,共8页
Samples of the PM-355 polymeric solid state nuclear track detector were exposed to low gamma absorbed doses from 1 kGy (0.1 Mrad) up to 9 kGy (0.9 Mrad). Positron annihilation lifetime (PAL) in conjunction with transm... Samples of the PM-355 polymeric solid state nuclear track detector were exposed to low gamma absorbed doses from 1 kGy (0.1 Mrad) up to 9 kGy (0.9 Mrad). Positron annihilation lifetime (PAL) in conjunction with transmission electron microscopy (TEM) and Thermo-gravimetric analysis (TGA) were performed on irradiated and pristine samples at room temperature. The observed lifetime spectra were resolved into three components where the ortho-positronium (o-Ps) lifetime component was associated with the pick-off annihilation of positronium trapped by the free volume. PAL studies of irradiated PM-355 samples showed that ortho-positronium (o-Ps) lifetime increases with an increase in dose up to 4 kGy and decreases at higher doses. In contrast, the intensity of the o-Ps component, I3, decreases with the dose up to about 2 kGy, followed by a much smooth decrease up to 7 kGy, and then it levels off. TGA analysis indicated that the PM-355 detector decomposed in one main breakdown stage. These results are discussed on the basis of chemical and physical changes occurring at the microscopic level in the PM-355 due to irradiation. Crosslinking dominates for doses between 1 and 4 kGy, while the degradation mechanism (Chain scission) prevails for doses up to 9 kGy. 展开更多
关键词 POSITRON ANNIHILATION LIFETIME Nuclear Track detector TEM gamma DOSE TGA
暂未订购
Gamma-Index Passing Rates in Baseline Plans Measured with a Detector Array
8
作者 Stanislaw Szpala Kirpal Kohli 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期326-337,共12页
Purpose: This study provides a simple protocol for validation of the gamma passing rates and to identify the optimum values of % dose and mm criteria for dose distributions measured with a detector array. Methods: We ... Purpose: This study provides a simple protocol for validation of the gamma passing rates and to identify the optimum values of % dose and mm criteria for dose distributions measured with a detector array. Methods: We chose ArcCHECK detector array to illustrate the concepts. We used plans with uniform or quasi-uniform dose distributions along the detector array for testing in the presence of dose errors. For testing sensitivity to spatial shift we employed a plan with approximately constant dose gradient along the axis of the instrument. Results: We identified a representative set of parameters which describe performance of a detector array. We determined the minimum gamma-index acceptance criteria allowing the passing rates to reach 100% in the absence of errors, and identified the minimum fully detectable errors for such criteria. For our baseline plans delivered to ArcCHECK, 100% passing rates were obtained for 1.5% dose criterion together with ±3% minimum error detectable at 100% rate, and for 1.5 mm criterion together with the minimum fully detectable error of ±3 mm. We inspected the impact of selected program options on the passing rates. Conclusions: The protocol we developed provides a simple method of commissioning-style analysis of a detector array without a need for analysis of a large number of clinical plans. 展开更多
关键词 gamma INDEX detector Array ArcCHECK Delivery ERROR
暂未订购
Development of a Gamma Spectroscopy Detector Based on SiPMs and 1" Ce:GAGG Scintillator
9
作者 Qiang Wang Zetao Zhang +6 位作者 Yuchong Ding Xuanhou Hu Xiong Xiao Biao Wang Jingjing Qu Qianyin Wan Yang Xu 《Journal of Applied Mathematics and Physics》 2023年第7期2156-2164,共9页
In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy ... In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy spectrum detectors based on gadolinium gallium aluminum garnet (Ce:GAGG) scintillation crystals are minor. In this work, a 1-inch Ce:GAGG and Silicon Photomultipliers (SiPMs) are employed to construct a detector, and the coupled medium was silicone oil. An optimal SiPMs quantity scheme for the energy resolution was determined by varying the number of SiPMs coupled to Ce:GAGG and studying the effect of the different number of SiPMs on the energy resolution of the detector. Energy-resolution contrast experiments between Ce:GAGG and NaI(Tl) were performed using this scheme. The experimental results demonstrate that increasing the number of SiPMs enhances the energy resolution of the detector significantly. Notably, the energy resolution of the Ce:GAGG detector is comparable to that of the NaI(Tl) detector. Additionally, both detectors exhibit an energy linearity exceeding 99.9%. . 展开更多
关键词 Ce:GAGG gamma Spectroscopy detector SiPMs Energy Resolution
在线阅读 下载PDF
Determination the Effect of Gamma Radiation and Thermal Neutron on PM-355 Detector by Using FTIR Spectroscopy
10
作者 Hussain Ali Al-Jobouri 《Detection》 2015年第3期15-20,共6页
The effect of gamma on nuclear track detector type PM-355 (at the dose range 200 to 1600 kGy) and thermal neutron (flux 105 n·cm-2·s-1) was calculated by using of two irradiation methods. First method (G + N... The effect of gamma on nuclear track detector type PM-355 (at the dose range 200 to 1600 kGy) and thermal neutron (flux 105 n·cm-2·s-1) was calculated by using of two irradiation methods. First method (G + N) was an irradiation PM-355 detector by gamma radiation and then irradiation by thermal neutrons, and another method (N + G) was irradiated by thermal neutrons and then gamma radiation. FTIR-spectroscopy was used to measure the change in deferent of transmission percent ΔT% at the wavenumber 1260 cm-1 with wavenumber 2962 cm-1 [ΔT%]1260-2962 and wavenumber 1138 cm-1 [ΔT%]1260-1138. The values of [ΔT%]1260-2962 and [ΔT%]1260-1138 were increasing with the increase of gamma irradiation with maximum response at 820 kGy and then drop after this dose until to 1600 kGy. This study determined the linear equations relation between the effect of gamma radiation on PM-355 detector and the change of [ΔT%]1260-2962 and [ΔT%]1260-1138, and this change appeared in (N + G) irradiation method better than in (G + N) irradiation method. The appearance of wavenumber 2964 cm-1 in (G + N) irradiation method referred to alkyl asymmetry C-H bond stretched out of skelated plane after changes in chemical structure of PM-355 detector by gamma or neutrons radiation. 展开更多
关键词 PM-355 NUCLEAR TRACK detectors gamma Radiation Thermal NEUTRON FTIR-SPECTROSCOPY
暂未订购
Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages
11
作者 Mebougna L. Drabo Stephen U. Egarievwe +4 位作者 Utpal N. Roy Benicia A. Harrison Carmella A. Goree Emmanuel K. Savage Ralph B. James 《Materials Sciences and Applications》 2020年第8期553-559,共7页
Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such... Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of <sup>241</sup>Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time. 展开更多
关键词 CdZnTeSe Energy Resolution Energy-Peak Stability gamma-Ray Spectroscopy Nuclear detectors
在线阅读 下载PDF
强γ辐射场中3He中子探测器应用研究
12
作者 李井怀 梁庆雷 +2 位作者 周浩 田园 刘国荣 《科学技术创新》 2026年第1期83-86,共4页
本文对广泛应用于后处理厂中子监测的3He探测器的工作条件进行了研究,包括提高探测效率和降低本底干扰。模拟强γ场进行了探测器性能测试,通过增加铅屏蔽降低γ射线对探测器的干扰,并对前置放大器提出了可行的保护措施,从而实现3He探测... 本文对广泛应用于后处理厂中子监测的3He探测器的工作条件进行了研究,包括提高探测效率和降低本底干扰。模拟强γ场进行了探测器性能测试,通过增加铅屏蔽降低γ射线对探测器的干扰,并对前置放大器提出了可行的保护措施,从而实现3He探测器在强γ辐射场中可以正常工作。 展开更多
关键词 强γ场 3He探测器 屏蔽
在线阅读 下载PDF
中波碲镉汞光伏探测器的实时gamma辐照效应(英文) 被引量:1
13
作者 乔辉 李淘 +1 位作者 龚海梅 李向阳 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2016年第2期129-132,共4页
对中波碲镉汞光伏探测器进行了实时gamma辐照效应研究.通过在辐照过程中对器件的电流—电压特性曲线进行测试,得到了器件电学性能随着gamma辐照剂量的变化.研究发现器件在辐照过程中表现出两种典型的辐照效应:电离效应和位移效应.电离... 对中波碲镉汞光伏探测器进行了实时gamma辐照效应研究.通过在辐照过程中对器件的电流—电压特性曲线进行测试,得到了器件电学性能随着gamma辐照剂量的变化.研究发现器件在辐照过程中表现出两种典型的辐照效应:电离效应和位移效应.电离效应可以通过辐照过程中类似光电流的产生来表现出来,而位移效应则通过辐照过程中器件串联电阻的增加来体现.两种效应都表现为总剂量效应.分析认为,由于位移效应引入的辐照损伤随着辐照剂量的增加越来越多,辐照电离效应产生的自由载流子产额随之逐渐降低,说明随着辐照剂量增加,电离效应逐渐降低,而位移效应则逐渐增强,导致器件性能衰退. 展开更多
关键词 gamma辐照 实时辐照效应 光伏探测器 碲镉汞
在线阅读 下载PDF
Determination of Gamma point source efficiency based on a backpropagation neural network 被引量:4
14
作者 Hong-Long Zheng Xian-Guo Tuo +4 位作者 Shu-Ming Peng Rui Shi Huai-Liang Li Jing Lu Jin-Fu Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第5期1-9,共9页
Efficiency is an important factor in quantitative and qualitative analysis of radionuclides, and the gamma point source efficiency is related to the radial angle,detection distance, and gamma-ray energy. In this work,... Efficiency is an important factor in quantitative and qualitative analysis of radionuclides, and the gamma point source efficiency is related to the radial angle,detection distance, and gamma-ray energy. In this work, on the basis of a back-propagation(BP) neural network model,a method to determine the gamma point source efficiency is developed and validated. The efficiency of the point sources ^(137)Cs and ^(60)Co at discrete radial angles, detection distances, and gamma-ray energies is measured, and the BP neural network prediction model is constructed using MATLAB. The gamma point source efficiencies at different radial angles, detection distances, and gamma-ray energies are predicted quickly and accurately using this nonlinear prediction model. The results show that the maximum error between the predicted and experimental values is 3.732% at 661.661 keV, 11π/24, and 35 cm, and those under other conditions are less than 3%. The gamma point source efficiencies obtained using the BP neural network model are in good agreement with experimental data. 展开更多
关键词 EFFICIENCY BP NEURAL network HPGE detector gamma point source
在线阅读 下载PDF
An inversion decomposition method for better energy resolution of NaI(Tl)scintillation detectors based on a Gaussian response matrix 被引量:5
15
作者 Jian-Feng He Yao-Zong Yang +3 位作者 Jin-Hui Qu Qi-Fan Wu Hai-Ling Xiao Cong-Cong Yu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期58-67,共10页
NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution ... NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides. 展开更多
关键词 闪烁探测器 能量分辨率 响应矩阵 分解方法 NAI 高斯 放射性核素 反演
在线阅读 下载PDF
Dosimetric Comparison of Amorphous Silicon EPID and 2D Array Detector for Pre-Treatment Verification of Intensity Modulated Radiation Therapy 被引量:1
16
作者 Ayman G. Ibrahim Ismail E. Mohamed Hamdy M. Zidan 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期438-452,共15页
Purpose: To study the dosimetric characteristics of amorphous silicon Electronic Portal Imaging Device EPID and 2D array detector for dose verification of radiotherapy treatment plans, and the quality assurance QA tes... Purpose: To study the dosimetric characteristics of amorphous silicon Electronic Portal Imaging Device EPID and 2D array detector for dose verification of radiotherapy treatment plans, and the quality assurance QA testing of IMRT was investigated. Materials and methods: All measurements were done with Varian IX linear accelerator, aSi-1000 EPID and 2D array detector. The dose linearity, reproducibility, output factors, dose rate, SDD and response with slap phantom thickness have been measured and compared against those measured by ion chamber. Results: The characteristics of EPID and 2D array: the response of EPID agreed with 2D array and ion chamber 0.6cc. EPID and 2D array showed short-term output reproducibility with SD = 0.1%. The dose rates of 2D array SD = ±0.7%, EPID = ±0.4% compared with a 0.6 cc SD = ±0.5%. Output factor measurements for the central chamber of the EPID and 2D array showed no considerable deviation from ion chamber measurements. Measurement of beam profiles with the EPID and 2D array matched very well with the ion chamber measurements in the water phantom. The EPID is more sensitive to lower energy photons by increasing solid water phantom thickness. The mean and standard deviation passing rates (γ%≤1) for film, 2D array and EPID for 30 IMRT fields of five patients were 95.93 ± 0.96%, 99.05 ± 0.24%, and 99.37 ± 0.12%, respectively. Conclusion: The study shows that EPID and 2D array are a reliable and accurate dosimeter and a useful tool for quality assurance. We found that the EPID was more accurate compared with both 2D array and ion chamber. The gamma criterion of 3%/3 mm is the most suitable criteria for IMRT plans of QA. 展开更多
关键词 IMRT EPID 2D Array detector gamma Index Quality ASSURANCE
暂未订购
Collimated LaBr_3 detector response function in radioactivity analysis of nuclear waste drums 被引量:1
17
作者 QIAN Nan WANG Dezhong +2 位作者 WANG Chuan ZHU Yuelong MAUERHOFER Eric 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第6期23-28,共6页
The properties of a Lanthanum bromide(LaBr3)detector and its response functions were investigated via experiments and simulations in this paper.The LaBr3detector had good relative energy resolution and higher efficien... The properties of a Lanthanum bromide(LaBr3)detector and its response functions were investigated via experiments and simulations in this paper.The LaBr3detector had good relative energy resolution and higher efficiency than a high-purity germanium detector.Monte Carlo and other numerical methods were used to calculate the efficiencies of a LaBr3detector with a square collimation window.A model of the numerical method was established based on a pure geometric model that was consistent with the experimental situation.The results showed that the detector response functions calculated by these methods were in great agreement with experimental results. 展开更多
关键词 LaBr3 响应函数 放射性分析 准直 探测器 检测器具 料桶 数值方法
在线阅读 下载PDF
Study of Chemical Etching and Chemo-Mechanical Polishing on CdZnTe Nuclear Detectors 被引量:1
18
作者 Aaron L. Adams Stephen U. Egarievwe +4 位作者 Ezekiel O. Agbalagba Rubi Gul Anwar Hossain Utpal N. Roy Ralph B. James 《Journal of Materials Science and Chemical Engineering》 2019年第8期33-41,共9页
Cadmium zinc telluride (CdZnTe) semiconductor has applications in the detection of X-rays and gamma-rays at room temperature without having to use a cooling system. Chemical etching and chemo-mechanical polishing are ... Cadmium zinc telluride (CdZnTe) semiconductor has applications in the detection of X-rays and gamma-rays at room temperature without having to use a cooling system. Chemical etching and chemo-mechanical polishing are processes used to smoothen CdZnTe wafer during detector device fabrication. These processes reduce surface damages left after polishing the wafers. In this paper, we compare the effects of etching and chemo-mechanical polishing on CdZnTe nuclear detectors, using a solution of hydrogen bromide in hydrogen peroxide and ethylene glycol mixture. X-ray photoelectron spectroscopy (XPS) was used to monitor TeO2 on the wafer surfaces. Current-voltage and detector-response measurements were made to study the electrical properties and energy resolution. XPS results showed that the chemical etching process resulted in the formation of more TeO2 on the detector surfaces compared to chemo-mechanical polishing. The electrical resistivity of the detector is of the order of 1010 &#937;-cm. The chemo-mechanical polishing process increased the leakage current more that chemical etching. For freshly treated surfaces, the etching process is more detrimental to the energy resolution compared to chemo-mechanically polishing. 展开更多
关键词 CDZNTE CHEMICAL ETCHING Chemo-Mechanical POLISHING gamma RAYS Nuclear detectors X-Ray PHOTOELECTRON Spectroscopy
在线阅读 下载PDF
Extraction of full energy peak of ^(137)Cs from in situ NaI(Tl)gamma-ray spectrum
19
作者 Le-Le Zhang Nan-Ping Wang Bao-Chuan Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第4期53-59,共7页
A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na ... A Levenberg–Marquardt Gaussian fitting algorithm has been used for analyzing the overlap of three peaks(the 583-ke V peak of^(208)Tl, the 609-ke V peak of214 Bi, and the 662-ke V peak of^(137)Cs) using an in situ Na I(Tl) scintillation spectrometer. The algorithm, in addition,was compared with a genetic algorithm used for multiple deconvolution. The three fitted peak areas(583, 609, and662 ke V) were calculated from the measured gamma-ray spectra obtained from a simulation experiment in which a^(137) Cs source was buried at different soil depths(from 18 to38 cm). The application of the Levenberg–Marquardt algorithm yielded similar results compared to the genetic algorithm. A lack-of-fit test showed that the fitting is good when the instrumental noise levels were estimated from replicated analyses. The relative fitting error of the total net area and the residual standard deviation were within 5 %and 0.04, respectively, and the goodness of the fitting was better than 0.98. While the methods used in this paper give high performance, the results may lead to incorrect estimation when the signal-to-noise ratio is smaller than-30 d B. This study is useful for the determination of radioactive specific activity of^(137) Cs by in situ spectrometry. 展开更多
关键词 137Cs γ射线谱 Marquardt算法 全能峰 GAUSSIAN 拟合算法 提取 相对拟合误差
在线阅读 下载PDF
Measurement of the Potassium Content of Different Food Samples with High Purity Germanium Detectors
20
作者 Iris Abt Lucia Garbini Oliver Schulz 《Detection》 2016年第3期73-85,共13页
Measurements of the potassium content of samples of food, performed with High Purity Germanium detectors, are presented in this paper. The potassium content was measured by identifying the 1460 keV photons produced in... Measurements of the potassium content of samples of food, performed with High Purity Germanium detectors, are presented in this paper. The potassium content was measured by identifying the 1460 keV photons produced in the decay of the isotope 40K. Samples were selected, for which a high potassium content was expected. The measurements confirmed the expectations qualitatively, but not always quantitatively. Especially the expected dependence of the potassium content of chocolate on the listed percentage of cacao could not be confirmed. 展开更多
关键词 HPGe detectors gamma Spectroscopy Food Testing
在线阅读 下载PDF