As the galvanized steels used for electrical and office appliances has achieved a complete chrome-free production worldwide,surface treatment technologies have entered a new phase of development.Grenter effort will be...As the galvanized steels used for electrical and office appliances has achieved a complete chrome-free production worldwide,surface treatment technologies have entered a new phase of development.Grenter effort will be made in exploring new frontier for future surface treatment technologies.A greater contribution will be made for environmental protection,energy-saving and resource-saving,to prevent globalwarming.展开更多
A group of projection welding experiments and joints tension-shear tests are carried out for cold-rolled steel sheets, galvanized steel sheets (GSS) without treatment, GSS with phosphating and GSS with surface greasin...A group of projection welding experiments and joints tension-shear tests are carried out for cold-rolled steel sheets, galvanized steel sheets (GSS) without treatment, GSS with phosphating and GSS with surface greasing, respectively. The experimental results are regressively analyzed on the computers, then the projection welded joint tension-shear strength curve and the perfect welding currents range of each material are obtained. The results show that surface treatments of galvanized steels have effects on their spot weldabilities. Among the four kinds of materials, GSS with surface greasing have the worst spot weldability, for they need higher welding current and have a narrow welding current range.展开更多
Zirconium-based conversion coatings have emerged as an environmentally friendly alternative to traditional phosphate coatings in the automotive industry,offering excellent corrosion resistance and effective protection...Zirconium-based conversion coatings have emerged as an environmentally friendly alternative to traditional phosphate coatings in the automotive industry,offering excellent corrosion resistance and effective protection for metal substrates.However,due to their relatively recent use in industrial applications,process control during zirconium conversion coating remains underdeveloped.In this study,the reaction kinetics of galvanized steel during the zirconium conversion coating were investigated systematically.The findings reveal an optimal coating time,after which the corrosion resistance of galvanized steel decreases.This decline results from the formation of corrosion cavities that cause discontinuities in the protective zirconium layer.These insights provide guidance for optimizing zirconium conversion coating processes in industrial manufacturing.展开更多
In this study,6061 aluminum alloy and galvanized steel fusion-brazed lap joints were obtained using a laser-arc hybrid heat source,and the effects of laser power variation on the microstructure,mechanical properties,a...In this study,6061 aluminum alloy and galvanized steel fusion-brazed lap joints were obtained using a laser-arc hybrid heat source,and the effects of laser power variation on the microstructure,mechanical properties,and fracture mechanism of the joints were ana-lyzed.The results showed that the tensile shear load initially increased with rising laser power,followed by a decrease.At a laser power of 240 W,the maximum tensile shear load was 2479.8 N/cm and the weak section of joint was in the Al-Fe reaction layer con-sisting of Fe(Al,Si)_(3),Fe_(2)(Al,Si)_(5),and Fe(Al,Si)intermetallic compounds(IMCs).Computational results showed that the inherently high brittleness and hardness of Fe(Al,Si)_(3) and the high mismatch rates of Fe(Al,Si)_(3)/Al interfaces were the key factor leading to the failure of the joints at lower heat input.展开更多
The present work aimed at using rare earth lanthanum salt and trimethoxy(viny)silance as chromate substitutes for galvanized steel passivation, in contrast to zinc coating samples treated with chromate.The corrosion...The present work aimed at using rare earth lanthanum salt and trimethoxy(viny)silance as chromate substitutes for galvanized steel passivation, in contrast to zinc coating samples treated with chromate.The corrosion resistance was assessed by electrochemical impedance spectroscopy(EIS) and neutral salt spray tests(NSS).Scanning electron microscopy(SEM) was used to characterize the sample surfaces.The organic coating adhesion on the panel was also investigated via varnishes-cross cut tests.The results indicated that rare earth and silane two-step treatment gave more effective anticorrosion performance than Cr, which also provided good paint adhesion.The coating formation mechanism was also discussed.展开更多
A complex film on hot-dip galvanized steel sheet(HDG) was prepared by immersing the sheet in 0.1wt.% Ce(NO3)3 solution and 5vol.% silane solution in turn.The corrosion protection of the complex film was evaluated ...A complex film on hot-dip galvanized steel sheet(HDG) was prepared by immersing the sheet in 0.1wt.% Ce(NO3)3 solution and 5vol.% silane solution in turn.The corrosion protection of the complex film was evaluated by potentiodynamic linear polarization(LPR), electrochemical impendence spectra(EIS) and natural salt spray(NSS) tests and compared with that of single cerium film and silane film.The results showed that, the presence of these films on the zinc coating hindered corrosion reaction by reducing the rate of both anodic and cathodic reaction in the corrosion process, and the corrosion protection of the complex film was much better than that of single cerium film or silane film and closed to that of chromate film, because the polarization resistance Rp and electrochemical impendence were increased markedly.Microstructure and chemical composition of these pretreated films were also investigated by scanning electron microscopy(SEM) and AES.展开更多
Modified lanthanum salt conversion coatings prepared by rare earth salt route based on lanthanum nitrate solution were proposed as alternatives to the process involving toxic hexavalent chromate.The structure and comp...Modified lanthanum salt conversion coatings prepared by rare earth salt route based on lanthanum nitrate solution were proposed as alternatives to the process involving toxic hexavalent chromate.The structure and composition of the coating were determined with X-ray energy dispersive spectrometer and X-ray photoelectron spectroscopy.The surface morphologies of the treated samples were observed with scanning electron microscopy.The natural salt spray and electrochemical impendence spectra tests were carried ...展开更多
A novel cerium-tannic acid passivation treatment was performed on galvanized steel. The corrosion resistance of cerium-tannic passivated samples was tested by dropping test with 0.5 wt.% CuSO4 aqueous solution. The ma...A novel cerium-tannic acid passivation treatment was performed on galvanized steel. The corrosion resistance of cerium-tannic passivated samples was tested by dropping test with 0.5 wt.% CuSO4 aqueous solution. The mass loss per unit area of passivated samples was measured after the corrosion in 0.5 mol/L NaCl + 0.005 mol/L H2SO4 at room temperature for 96 h. The electrochemical behaviors of cerium, tannic acid, and cerium-tannic acid passivated samples on galvanized steel in 0.5 mol/L NaCl solution were investigated by polarization curves and electrochemical impendence spectra. The corrosion equivalent circuit was established according to the impedance characteristics. The results show that cerium-tannic acid treated samples exhibit better corrosion resistance than the sole cerium or tannic acid treated samples under the same condition. The mechanism of synergistic effect for cerium-tannic acid passivation on galvanized steel was discussed.展开更多
In an aqueous solution of the mixtures of γ-amino propyl triethoxy silane and γ-glycidoxy propyl trimethoxy silane, a composite silane conversion coating was developed on galvanized steel. FESEM (field emission sca...In an aqueous solution of the mixtures of γ-amino propyl triethoxy silane and γ-glycidoxy propyl trimethoxy silane, a composite silane conversion coating was developed on galvanized steel. FESEM (field emission scanning electron microscope), XPS (X-ray photoelectron spectroscopy), ATR FTIR (attenuated total reflection Flourier transform infrared spectroscopy) and SST (salt spray test) were used to characterize the obtained composite silane conversion coating and also the coating formation process was studied. The result showed that the surface of the composite silane conversion coating was complete, consecutive and compact. The coating could endure a neutral salt spray test for 72 h without corrosion. The result of salt spray test indicated that the composite silane conversion coating can provide a better corrosion inhibition than the coating which was composed of the single silane. Based on observation and analysis, it was proposed that the formation process of the silane coating on zinc should consist of three steps: the hydrolysis of the silane molecules, silane chemical adsorption and silane crosslinking condensation. The crosslinking reactions took place between ~'-amino propyl triethoxy and "/-glycidoxy propyl trimethoxy silane during the forming process of the coating, and a high crosslinked density interpenetrating structure network was obtained, so the composite silane conversion coating could keep the corrosive substances from the zinc more effectively.展开更多
A laser lap welding process for zinc-coated steel has a well-known unsolved problem-porosity formation. The boiling temperature of coated zinc is lower than the melting temperature of the base metal, which is steel. I...A laser lap welding process for zinc-coated steel has a well-known unsolved problem-porosity formation. The boiling temperature of coated zinc is lower than the melting temperature of the base metal, which is steel. In the autogenous laser welding, the zinc vapor generates from the lapped surfaces expels the molten pool and the expulsion causes numerous weld defects, such as spatters and blow holes on the weld surface and porosity inside the welds. The laser-arc hybrid welding was suggested as an alternative method for the laser lap welding because the arc can preheat or post-beat the weldment according to the arrangement of the laser beam and the arc. CO2 laser-micro plasma hybrid welding was applied to the lap welding of zinc-coated steel with zero-gap. The relationships among the weld quality and process parameters of the laser-arc arrangement, and the laser-arc interspacing distance and arc current were investigated using a full-factorial experimental design. The effect of laser-arc arrangement is dominant because the leading plasma arc partially melts the upper steel sheets and vaporizes or oxidizes the coated zinc on the lapped surfaces. Compared with the result from the laser-TIG hybrid welding, the heat input from arc can be reduced by 40%.展开更多
The corrosion behavior and mechanism of hot-dip galvanized steel and interstitial-free (IF) substrate with alkaline mud adhesion were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), ...The corrosion behavior and mechanism of hot-dip galvanized steel and interstitial-free (IF) substrate with alkaline mud adhesion were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and linear polarization. The results show that non-uniform corrosion occurs on the galvanized steel and IF substrate during 250 h with the mud adhesion. The corrosion products on the galvanized steel are very loose and porous, which are mainly ZnO, Zn5(OH)8C12·H2O and Zn(OH)2, and Fe-Zn alloy layer with a lower corrosion rate is exposed on the galvanized steel surface; however, the corrosion products on IF substrate are considerably harder and denser, whose compositions of rust are mainly FeOOH and Fe3O4, and several pits appear on their surface. The results of continuous EIS and linear polarization measurements exhibit a corrosion mechanism, that is, under activation control, the charge transfer resistances present different tendencies between the galvanized steel and IF substrate; in addition, the evolution of linear polarization resistances is similar to that of charge transfer resistances. The higher contents of dissolved oxygen and Cl^- ions in the mud play an important role in accelerating the corrosion.展开更多
In this work, laser heat conduction lap welding(LHCLW) of AZ31B magnesium alloy sheet and DP780galvanized steel sheet was carried out by the defocused laser beam. The effects of laser power on the microstructure and m...In this work, laser heat conduction lap welding(LHCLW) of AZ31B magnesium alloy sheet and DP780galvanized steel sheet was carried out by the defocused laser beam. The effects of laser power on the microstructure and mechanical properties of the joint were studied. The pros and cons of the joint were identified and evaluated by measuring the tensile shear strength, microhardness and microstructure observation. The formation mechanism of various phases at the Mg/steel interface was analyzed. The results indicated that the galvanized layer could promote the metallurgical bonding between magnesium alloy and steel by improving the diffusion ability of molten magnesium alloy at the steel interface and reacting with Mg, so as to enhance the strength of the joint. A continuous dense layered eutectic structure(α-Mg+MgZn) was formed at the interface of the joint, while MgZn_(2)and MgZn phase was formed at the weld edge zone and heat affective zone(HAZ), whereas no reaction layer was generated between the uncoated steel and magnesium alloy. A sound joint could be obtained at 2.5 kW, and the corresponding tensile shear strength reached the maximum value of 42.9 N/mm. The strength was slightly reduced at 2.6 kW due to the existence of microcracks in the eutectic reaction layer.展开更多
Scanning electron microscopy,X-ray diffraction,a neutral salt spray test,and electrochemical methods were applied to observe the microstructure and test the corrosion resistance of hot-dip galvanized steel before and ...Scanning electron microscopy,X-ray diffraction,a neutral salt spray test,and electrochemical methods were applied to observe the microstructure and test the corrosion resistance of hot-dip galvanized steel before and after the addition of La and Ce.La/Ce mixture existed in the form of(La,Ce)Zn13 on the coated surface,decreased the coating thickness and accelerated the zinc dendritic growth.The corrosion current density of Zn-0.1La-0.1Ce coating was 63%less than that of pure Zn coating.This phenomenon can be explained that La/Ce mixture inhibited the transformation of Zn5(OH)8Cl2·H2O into Zn5(CO3)2(OH)6 or ZnO,reduced the time for appearance of red rust,and thus enhanced the stability of corrosion products and delayed the oxidation and corrosion processes of galvanized coating.La/Ce mixture improved the corrosion resistance compared to a single La or a single Ce addition.A competitive relationship between La and Ce was observed in the corrosion resistance improvement of hot-dip galvanized steel.展开更多
Powdering/exfoliating of coatings and scratching galvanized steels and high strength steels (HSS), are the main forms of surface damage in the forming of which result in increased die maintenance cost and scrap rate...Powdering/exfoliating of coatings and scratching galvanized steels and high strength steels (HSS), are the main forms of surface damage in the forming of which result in increased die maintenance cost and scrap rate. In this study, a special rectangular box was developed to investigate the behavior and characteristics of surface damage in sheet metal forming (SMF) processes. U-channel forming tests were conducted to study the effect of tool hardness on surface damage in the forming of high strength steels and galvanized steels (hot-dip galvanized and galvannealed steels). Experimental results indicate that sheet deformation mode influences the severity of surface damage in SMF and surface damage occurs easily at the regions where sheet specimen deforms under the action of compressive stress. Die corner is the position where surface damage initiates. For HSS sheet, surface damage is of major interest due to high forming pressure. The HSS and hot-dip galvanized steels show improved ability of damage-resistance with increased hardness of the forming tool. However, for galvannealed steel it is not the forming tool with the highest hardness value that performs best.展开更多
To improve the corrosion resistance of phosphate coatings, the phosphated hot-dip galvanized (HDG) steel was post-sealed with cerium nitrate solution. The morphology, composition, corrosion resistance of the coatings ...To improve the corrosion resistance of phosphate coatings, the phosphated hot-dip galvanized (HDG) steel was post-sealed with cerium nitrate solution. The morphology, composition, corrosion resistance of the coatings was investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and neutral salt spray (NSS) tests. The results show that after post-sealing the phosphated HDG samples with cerium nitrate solution, the pores among the zinc phosphate crystals are sealed by the compounds containing phosphorus, oxygen and cerium; the zinc phosphate crystals are covered by the flocculent cerium compounds; and the continuous composite coatings are formed on HDG steel. The corrosion resistance of the composite coatings, which increases with the increase in phosphating time and cerium nitrate post-sealing time, is far higher than that of the single phosphate coatings. The composite coatings with the optimal corrosion resistance are obtained for phosphating 300 s and post-sealing 300 s; and the corrosion resistance is more outstanding than that of the chromate coatings.展开更多
Resistance spot brazing was used to perform the lap test of pure aluminum 1060 and SGCC hot-dip galvanized steel plate,the joint interface structure was studied,and the mechanical properties of the joint were tested.T...Resistance spot brazing was used to perform the lap test of pure aluminum 1060 and SGCC hot-dip galvanized steel plate,the joint interface structure was studied,and the mechanical properties of the joint were tested.The results show that the aluminum-silicon(Al-Si)alloy solder used in the test has good wetting,and an intermetallic compound with a double-layer structure and uneven thickness is produced at the welded joint interface after welding.The thickness is<10μm.The welding current is at 7.8 kA,the tensile shear load of the joint reaches a peak value of about 4.72 kN.Under the same process parameters,the tensile shear load of the resistance spot brazed joint is significantly higher than that of the spot welded joint.The joint fracture mostly occurs on the aluminum plate side,and mainly at the heat-affected zone and not at the welding point.It indicates that the quality of the spot brazed joint is good,but due to the local"unbrazed"defect on the aluminum side interface of the weld,tensile stress will occur at the weld interface and the stress effect on the intermetallic compound.It is easy to produce cracks.展开更多
The process properties and interface behavior of CO_2 laser brazing with automatic wire feed for galvanized steel sheets were investigated, in which the brazing filler metal was CuSi3 and no flux was used. As to the a...The process properties and interface behavior of CO_2 laser brazing with automatic wire feed for galvanized steel sheets were investigated, in which the brazing filler metal was CuSi3 and no flux was used. As to the appearance quality of the brazing seams, the roles of the processing parameters, such as brazing speed, wire feeding rate, inclination and feeding direction of the wire, laser power, spot diameter and heating position, were assessed. The further investigation indicates that the behavior of the active elements Si, Mn and Zn are significantly influenced by energy input. At the interface, the microstructure of the base metal was composed of columnar crystals and the acicular α solid solution was found on the filler metal side.展开更多
We present a novel method to monitor the weld geometry for metal inert gas(MIG)welding process with galvanized steel plates using Bayesian network(BN),and propose an effective method of extracting the weld reinforceme...We present a novel method to monitor the weld geometry for metal inert gas(MIG)welding process with galvanized steel plates using Bayesian network(BN),and propose an effective method of extracting the weld reinforcement and width online.The laser vision sensor is mounted after the welding torch and used to profile the weld.With the extracted weld geometry and the adopted process parameters,a back propagation neural network(BPNN)is constructed offline and used to predict the weld reinforcement and width corresponding to the current parameter settings.A BN from welding experience and tests is presented to implement the decision making of welding current/voltage when the error between the predictive geometry and the actual one occurs.This study can deal with the negative welding tendency to adapt to welding randomness and indicates a valuable application prospect in the welding field.展开更多
Laser fusion brazing welding was proposed.Galvanized steel/AA6061 lapped joint was obtained by laser fusion brazing welding technique using the laser-induced aluminium molten pool spreading and wetting the solid steel...Laser fusion brazing welding was proposed.Galvanized steel/AA6061 lapped joint was obtained by laser fusion brazing welding technique using the laser-induced aluminium molten pool spreading and wetting the solid steel surface.Wide joint interface was formed using the rectangular laser beam coupled with the synchronous powder feeding.The result showed that the tiny structure with the composition of a-Al and Al–Si eutectic was formed in the weld close to the Al side.And close to the steel side,a layer of compact Fe–Al–Si intermetallics,including the Al-rich FeAl3,Fe2Al5 phases and Al–Fe–Si s1 phase,was generated with the thickness of about 10–20 lm.Transverse tensile shows the brittlefractured characteristic along to the seam/steel interface with the maximum yield strength of 152.5 MPa due to the existence of hardening phases s1 and Al–Fe intermetallics.展开更多
Four kinds of galvanized steel sheets having different surface roughness values were used to prepare the steel sheets with a self-lubricated coating. The effects of surface roughness on the surface lubrication perform...Four kinds of galvanized steel sheets having different surface roughness values were used to prepare the steel sheets with a self-lubricated coating. The effects of surface roughness on the surface lubrication performance of the steel sheets were examined using a friction coefficient tester. Results revealed large dynamic friction coefficients for the galvanized steel sheets, which increased remarkably with surface roughness. Once the self-lubricated coating was applied, significant drops in the dynamic friction coefficients were measured. After the first stage of the friction test,the coefficients were almost unchanged, which reflected a weak dependence on the surface roughness of the self-lubricated steel sheets. However, the dynamic friction coefficients gradually increased as the test progressed, where these increase clearly correlated with the surface roughness of the self-lubricated steel sheets.展开更多
文摘As the galvanized steels used for electrical and office appliances has achieved a complete chrome-free production worldwide,surface treatment technologies have entered a new phase of development.Grenter effort will be made in exploring new frontier for future surface treatment technologies.A greater contribution will be made for environmental protection,energy-saving and resource-saving,to prevent globalwarming.
文摘A group of projection welding experiments and joints tension-shear tests are carried out for cold-rolled steel sheets, galvanized steel sheets (GSS) without treatment, GSS with phosphating and GSS with surface greasing, respectively. The experimental results are regressively analyzed on the computers, then the projection welded joint tension-shear strength curve and the perfect welding currents range of each material are obtained. The results show that surface treatments of galvanized steels have effects on their spot weldabilities. Among the four kinds of materials, GSS with surface greasing have the worst spot weldability, for they need higher welding current and have a narrow welding current range.
基金express their sincere gratitude to the Jiangsu Key Laboratory of Advanced Metallic Materials of Southeast University for providing the complete laboratory facilities required for this research project.
文摘Zirconium-based conversion coatings have emerged as an environmentally friendly alternative to traditional phosphate coatings in the automotive industry,offering excellent corrosion resistance and effective protection for metal substrates.However,due to their relatively recent use in industrial applications,process control during zirconium conversion coating remains underdeveloped.In this study,the reaction kinetics of galvanized steel during the zirconium conversion coating were investigated systematically.The findings reveal an optimal coating time,after which the corrosion resistance of galvanized steel decreases.This decline results from the formation of corrosion cavities that cause discontinuities in the protective zirconium layer.These insights provide guidance for optimizing zirconium conversion coating processes in industrial manufacturing.
基金supported by the National Key Research and Development Program of China(No.2022YFB4600900).
文摘In this study,6061 aluminum alloy and galvanized steel fusion-brazed lap joints were obtained using a laser-arc hybrid heat source,and the effects of laser power variation on the microstructure,mechanical properties,and fracture mechanism of the joints were ana-lyzed.The results showed that the tensile shear load initially increased with rising laser power,followed by a decrease.At a laser power of 240 W,the maximum tensile shear load was 2479.8 N/cm and the weak section of joint was in the Al-Fe reaction layer con-sisting of Fe(Al,Si)_(3),Fe_(2)(Al,Si)_(5),and Fe(Al,Si)intermetallic compounds(IMCs).Computational results showed that the inherently high brittleness and hardness of Fe(Al,Si)_(3) and the high mismatch rates of Fe(Al,Si)_(3)/Al interfaces were the key factor leading to the failure of the joints at lower heat input.
文摘The present work aimed at using rare earth lanthanum salt and trimethoxy(viny)silance as chromate substitutes for galvanized steel passivation, in contrast to zinc coating samples treated with chromate.The corrosion resistance was assessed by electrochemical impedance spectroscopy(EIS) and neutral salt spray tests(NSS).Scanning electron microscopy(SEM) was used to characterize the sample surfaces.The organic coating adhesion on the panel was also investigated via varnishes-cross cut tests.The results indicated that rare earth and silane two-step treatment gave more effective anticorrosion performance than Cr, which also provided good paint adhesion.The coating formation mechanism was also discussed.
基金supported by the United Nations Common Fund for Commodities (CFC/LZSG/12)
文摘A complex film on hot-dip galvanized steel sheet(HDG) was prepared by immersing the sheet in 0.1wt.% Ce(NO3)3 solution and 5vol.% silane solution in turn.The corrosion protection of the complex film was evaluated by potentiodynamic linear polarization(LPR), electrochemical impendence spectra(EIS) and natural salt spray(NSS) tests and compared with that of single cerium film and silane film.The results showed that, the presence of these films on the zinc coating hindered corrosion reaction by reducing the rate of both anodic and cathodic reaction in the corrosion process, and the corrosion protection of the complex film was much better than that of single cerium film or silane film and closed to that of chromate film, because the polarization resistance Rp and electrochemical impendence were increased markedly.Microstructure and chemical composition of these pretreated films were also investigated by scanning electron microscopy(SEM) and AES.
基金supported by the International Zinc Association,Belgium (IZA/CA/056)
文摘Modified lanthanum salt conversion coatings prepared by rare earth salt route based on lanthanum nitrate solution were proposed as alternatives to the process involving toxic hexavalent chromate.The structure and composition of the coating were determined with X-ray energy dispersive spectrometer and X-ray photoelectron spectroscopy.The surface morphologies of the treated samples were observed with scanning electron microscopy.The natural salt spray and electrochemical impendence spectra tests were carried ...
基金supported by the Science and Technology Foundation of the Department of Education of Jiangxi Province,China (No. GJJ08205)
文摘A novel cerium-tannic acid passivation treatment was performed on galvanized steel. The corrosion resistance of cerium-tannic passivated samples was tested by dropping test with 0.5 wt.% CuSO4 aqueous solution. The mass loss per unit area of passivated samples was measured after the corrosion in 0.5 mol/L NaCl + 0.005 mol/L H2SO4 at room temperature for 96 h. The electrochemical behaviors of cerium, tannic acid, and cerium-tannic acid passivated samples on galvanized steel in 0.5 mol/L NaCl solution were investigated by polarization curves and electrochemical impendence spectra. The corrosion equivalent circuit was established according to the impedance characteristics. The results show that cerium-tannic acid treated samples exhibit better corrosion resistance than the sole cerium or tannic acid treated samples under the same condition. The mechanism of synergistic effect for cerium-tannic acid passivation on galvanized steel was discussed.
基金Item Sponsored by National High-Tech Research and Development Program(863 Program)of China(2009AA03Z529)
文摘In an aqueous solution of the mixtures of γ-amino propyl triethoxy silane and γ-glycidoxy propyl trimethoxy silane, a composite silane conversion coating was developed on galvanized steel. FESEM (field emission scanning electron microscope), XPS (X-ray photoelectron spectroscopy), ATR FTIR (attenuated total reflection Flourier transform infrared spectroscopy) and SST (salt spray test) were used to characterize the obtained composite silane conversion coating and also the coating formation process was studied. The result showed that the surface of the composite silane conversion coating was complete, consecutive and compact. The coating could endure a neutral salt spray test for 72 h without corrosion. The result of salt spray test indicated that the composite silane conversion coating can provide a better corrosion inhibition than the coating which was composed of the single silane. Based on observation and analysis, it was proposed that the formation process of the silane coating on zinc should consist of three steps: the hydrolysis of the silane molecules, silane chemical adsorption and silane crosslinking condensation. The crosslinking reactions took place between ~'-amino propyl triethoxy and "/-glycidoxy propyl trimethoxy silane during the forming process of the coating, and a high crosslinked density interpenetrating structure network was obtained, so the composite silane conversion coating could keep the corrosive substances from the zinc more effectively.
文摘A laser lap welding process for zinc-coated steel has a well-known unsolved problem-porosity formation. The boiling temperature of coated zinc is lower than the melting temperature of the base metal, which is steel. In the autogenous laser welding, the zinc vapor generates from the lapped surfaces expels the molten pool and the expulsion causes numerous weld defects, such as spatters and blow holes on the weld surface and porosity inside the welds. The laser-arc hybrid welding was suggested as an alternative method for the laser lap welding because the arc can preheat or post-beat the weldment according to the arrangement of the laser beam and the arc. CO2 laser-micro plasma hybrid welding was applied to the lap welding of zinc-coated steel with zero-gap. The relationships among the weld quality and process parameters of the laser-arc arrangement, and the laser-arc interspacing distance and arc current were investigated using a full-factorial experimental design. The effect of laser-arc arrangement is dominant because the leading plasma arc partially melts the upper steel sheets and vaporizes or oxidizes the coated zinc on the lapped surfaces. Compared with the result from the laser-TIG hybrid welding, the heat input from arc can be reduced by 40%.
基金supported by the National Natural Science Foundation of China(No.50571022)the National Science & Technology Infrastructure Development Program of China(No.2005DKA10400)
文摘The corrosion behavior and mechanism of hot-dip galvanized steel and interstitial-free (IF) substrate with alkaline mud adhesion were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and linear polarization. The results show that non-uniform corrosion occurs on the galvanized steel and IF substrate during 250 h with the mud adhesion. The corrosion products on the galvanized steel are very loose and porous, which are mainly ZnO, Zn5(OH)8C12·H2O and Zn(OH)2, and Fe-Zn alloy layer with a lower corrosion rate is exposed on the galvanized steel surface; however, the corrosion products on IF substrate are considerably harder and denser, whose compositions of rust are mainly FeOOH and Fe3O4, and several pits appear on their surface. The results of continuous EIS and linear polarization measurements exhibit a corrosion mechanism, that is, under activation control, the charge transfer resistances present different tendencies between the galvanized steel and IF substrate; in addition, the evolution of linear polarization resistances is similar to that of charge transfer resistances. The higher contents of dissolved oxygen and Cl^- ions in the mud play an important role in accelerating the corrosion.
基金Projects(51705219, 51905227) supported by the National Natural Science Foundation of ChinaProject(BK20200915) supported by the Natural Science Foundation of Jiangsu Province,ChinaProject(19KJB460013) supported by the General University Science Research Project of Jiangsu Province,China。
文摘In this work, laser heat conduction lap welding(LHCLW) of AZ31B magnesium alloy sheet and DP780galvanized steel sheet was carried out by the defocused laser beam. The effects of laser power on the microstructure and mechanical properties of the joint were studied. The pros and cons of the joint were identified and evaluated by measuring the tensile shear strength, microhardness and microstructure observation. The formation mechanism of various phases at the Mg/steel interface was analyzed. The results indicated that the galvanized layer could promote the metallurgical bonding between magnesium alloy and steel by improving the diffusion ability of molten magnesium alloy at the steel interface and reacting with Mg, so as to enhance the strength of the joint. A continuous dense layered eutectic structure(α-Mg+MgZn) was formed at the interface of the joint, while MgZn_(2)and MgZn phase was formed at the weld edge zone and heat affective zone(HAZ), whereas no reaction layer was generated between the uncoated steel and magnesium alloy. A sound joint could be obtained at 2.5 kW, and the corresponding tensile shear strength reached the maximum value of 42.9 N/mm. The strength was slightly reduced at 2.6 kW due to the existence of microcracks in the eutectic reaction layer.
基金This work was supported by the National Key Research and Development Program of China(Grant No.2017YFB0702100)the State Key Laboratory of Baiyunobo Rare Earth Resource Researches and Comprehensive Utilization(2018Z2001).The authors gratefully acknowledge support for materials analysis and research from Instrumental Analysis and Research Center of Shanghai University.
文摘Scanning electron microscopy,X-ray diffraction,a neutral salt spray test,and electrochemical methods were applied to observe the microstructure and test the corrosion resistance of hot-dip galvanized steel before and after the addition of La and Ce.La/Ce mixture existed in the form of(La,Ce)Zn13 on the coated surface,decreased the coating thickness and accelerated the zinc dendritic growth.The corrosion current density of Zn-0.1La-0.1Ce coating was 63%less than that of pure Zn coating.This phenomenon can be explained that La/Ce mixture inhibited the transformation of Zn5(OH)8Cl2·H2O into Zn5(CO3)2(OH)6 or ZnO,reduced the time for appearance of red rust,and thus enhanced the stability of corrosion products and delayed the oxidation and corrosion processes of galvanized coating.La/Ce mixture improved the corrosion resistance compared to a single La or a single Ce addition.A competitive relationship between La and Ce was observed in the corrosion resistance improvement of hot-dip galvanized steel.
基金supported by the National Natural Science Foundation of China under grant No. 50605043
文摘Powdering/exfoliating of coatings and scratching galvanized steels and high strength steels (HSS), are the main forms of surface damage in the forming of which result in increased die maintenance cost and scrap rate. In this study, a special rectangular box was developed to investigate the behavior and characteristics of surface damage in sheet metal forming (SMF) processes. U-channel forming tests were conducted to study the effect of tool hardness on surface damage in the forming of high strength steels and galvanized steels (hot-dip galvanized and galvannealed steels). Experimental results indicate that sheet deformation mode influences the severity of surface damage in SMF and surface damage occurs easily at the regions where sheet specimen deforms under the action of compressive stress. Die corner is the position where surface damage initiates. For HSS sheet, surface damage is of major interest due to high forming pressure. The HSS and hot-dip galvanized steels show improved ability of damage-resistance with increased hardness of the forming tool. However, for galvannealed steel it is not the forming tool with the highest hardness value that performs best.
文摘To improve the corrosion resistance of phosphate coatings, the phosphated hot-dip galvanized (HDG) steel was post-sealed with cerium nitrate solution. The morphology, composition, corrosion resistance of the coatings was investigated by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and neutral salt spray (NSS) tests. The results show that after post-sealing the phosphated HDG samples with cerium nitrate solution, the pores among the zinc phosphate crystals are sealed by the compounds containing phosphorus, oxygen and cerium; the zinc phosphate crystals are covered by the flocculent cerium compounds; and the continuous composite coatings are formed on HDG steel. The corrosion resistance of the composite coatings, which increases with the increase in phosphating time and cerium nitrate post-sealing time, is far higher than that of the single phosphate coatings. The composite coatings with the optimal corrosion resistance are obtained for phosphating 300 s and post-sealing 300 s; and the corrosion resistance is more outstanding than that of the chromate coatings.
文摘Resistance spot brazing was used to perform the lap test of pure aluminum 1060 and SGCC hot-dip galvanized steel plate,the joint interface structure was studied,and the mechanical properties of the joint were tested.The results show that the aluminum-silicon(Al-Si)alloy solder used in the test has good wetting,and an intermetallic compound with a double-layer structure and uneven thickness is produced at the welded joint interface after welding.The thickness is<10μm.The welding current is at 7.8 kA,the tensile shear load of the joint reaches a peak value of about 4.72 kN.Under the same process parameters,the tensile shear load of the resistance spot brazed joint is significantly higher than that of the spot welded joint.The joint fracture mostly occurs on the aluminum plate side,and mainly at the heat-affected zone and not at the welding point.It indicates that the quality of the spot brazed joint is good,but due to the local"unbrazed"defect on the aluminum side interface of the weld,tensile stress will occur at the weld interface and the stress effect on the intermetallic compound.It is easy to produce cracks.
文摘The process properties and interface behavior of CO_2 laser brazing with automatic wire feed for galvanized steel sheets were investigated, in which the brazing filler metal was CuSi3 and no flux was used. As to the appearance quality of the brazing seams, the roles of the processing parameters, such as brazing speed, wire feeding rate, inclination and feeding direction of the wire, laser power, spot diameter and heating position, were assessed. The further investigation indicates that the behavior of the active elements Si, Mn and Zn are significantly influenced by energy input. At the interface, the microstructure of the base metal was composed of columnar crystals and the acicular α solid solution was found on the filler metal side.
基金the National Natural Science Foundation of China(No.51665037)the Open Fund of the Key Laboratory of Lightweight and High Strength Structural Materials of Jiangxi Province(No.20171BCD40003)the Open Fund of the Key Tahoratory of Nondestructive Testing Ministry of Education,Nanchang Hangkong University of China.(No.EW201980090)。
文摘We present a novel method to monitor the weld geometry for metal inert gas(MIG)welding process with galvanized steel plates using Bayesian network(BN),and propose an effective method of extracting the weld reinforcement and width online.The laser vision sensor is mounted after the welding torch and used to profile the weld.With the extracted weld geometry and the adopted process parameters,a back propagation neural network(BPNN)is constructed offline and used to predict the weld reinforcement and width corresponding to the current parameter settings.A BN from welding experience and tests is presented to implement the decision making of welding current/voltage when the error between the predictive geometry and the actual one occurs.This study can deal with the negative welding tendency to adapt to welding randomness and indicates a valuable application prospect in the welding field.
基金financially supported by the National Natural Science Foundation of China (No.50875005)Beijing Natural Science Foundation (No.3102005)
文摘Laser fusion brazing welding was proposed.Galvanized steel/AA6061 lapped joint was obtained by laser fusion brazing welding technique using the laser-induced aluminium molten pool spreading and wetting the solid steel surface.Wide joint interface was formed using the rectangular laser beam coupled with the synchronous powder feeding.The result showed that the tiny structure with the composition of a-Al and Al–Si eutectic was formed in the weld close to the Al side.And close to the steel side,a layer of compact Fe–Al–Si intermetallics,including the Al-rich FeAl3,Fe2Al5 phases and Al–Fe–Si s1 phase,was generated with the thickness of about 10–20 lm.Transverse tensile shows the brittlefractured characteristic along to the seam/steel interface with the maximum yield strength of 152.5 MPa due to the existence of hardening phases s1 and Al–Fe intermetallics.
文摘Four kinds of galvanized steel sheets having different surface roughness values were used to prepare the steel sheets with a self-lubricated coating. The effects of surface roughness on the surface lubrication performance of the steel sheets were examined using a friction coefficient tester. Results revealed large dynamic friction coefficients for the galvanized steel sheets, which increased remarkably with surface roughness. Once the self-lubricated coating was applied, significant drops in the dynamic friction coefficients were measured. After the first stage of the friction test,the coefficients were almost unchanged, which reflected a weak dependence on the surface roughness of the self-lubricated steel sheets. However, the dynamic friction coefficients gradually increased as the test progressed, where these increase clearly correlated with the surface roughness of the self-lubricated steel sheets.