According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic...According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic anode coupled with carbon steel is tested in3.5%NaCl solution and ambient temperature.Rapid evaluation the performance of galvanic anode using galvanic current is feasible,and the test time is20min.The galvanic current is used to select aluminum galvanic anodes in oil brine,and then test the galvanic anodes with impressed current test method.The result shows,the performance of galvanic anodes degrads in oil brine,but has not much difference in the two media to the preferable anodes,and the optimal galvanic anode is gained.展开更多
An experimental model for simulating the corrosion of carbon steel fasteners(bolt and nut) composed of a contact carbon steel electrode(CCSE) and an exposed bare carbon steel plate electrode(BCSE) was designed. The ef...An experimental model for simulating the corrosion of carbon steel fasteners(bolt and nut) composed of a contact carbon steel electrode(CCSE) and an exposed bare carbon steel plate electrode(BCSE) was designed. The effect of coupling on the corrosion process of the galvanically coupled carbon steel electrode was evaluated and compared with the self-corrosion process observed independently at the exposed and contact regions. Results obtained indicated that at an equal area ratio and uncoupled conditions, the corrosion rate is accelerated in the surface directly exposed to bulk solution compared to the bolt surface in contact with the nut. A coupling current was recorded when the exposed surface(BCSE) was electrically connected with the contact surface(CCSE);with the CCSE acting as the anode thereby suppressing the corrosion process in the exposed surface. By implication, the galvanic coupling between CCSE and BCSE increased the corrosion rate of CCSE. The diff erence in oxygen supply was responsible for the coupling effect observed in the system as there was no decrease in the solution pH. Moreover, varying the cathode-to-anode area( S c/S a) ratio significantly influenced the corrosion current density as increased S c/S a ratio resulted in an accelerated galvanic corrosion process. The corroded surfaces and interfaces were analysed using stereomicroscopy and scanning electron microscopy. X-ray diff ractometry was adopted for corrosion product characterization. The results obtained showed supportive evidence of the corrosion behaviour in carbon steel fasteners.展开更多
基金National Natural Science Foundation of China(Nos.51204147,51274175,51574206,51574207)Program for International S&T Cooperation Projects of China(No.2014DFA50320)+1 种基金Program for International S&T Cooperation Projects of Shanxi Province(No.201381017)Technological Projects of Shanxi Province(No.20150313002-3)
文摘According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic anode coupled with carbon steel is tested in3.5%NaCl solution and ambient temperature.Rapid evaluation the performance of galvanic anode using galvanic current is feasible,and the test time is20min.The galvanic current is used to select aluminum galvanic anodes in oil brine,and then test the galvanic anodes with impressed current test method.The result shows,the performance of galvanic anodes degrads in oil brine,but has not much difference in the two media to the preferable anodes,and the optimal galvanic anode is gained.
基金financially supported by the National Natural Science Foundation of China(No.51801219)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(2019193,KGFZD-135-19-02)the National Key Research Development Program of China(No.2017YFB0702302)。
文摘An experimental model for simulating the corrosion of carbon steel fasteners(bolt and nut) composed of a contact carbon steel electrode(CCSE) and an exposed bare carbon steel plate electrode(BCSE) was designed. The effect of coupling on the corrosion process of the galvanically coupled carbon steel electrode was evaluated and compared with the self-corrosion process observed independently at the exposed and contact regions. Results obtained indicated that at an equal area ratio and uncoupled conditions, the corrosion rate is accelerated in the surface directly exposed to bulk solution compared to the bolt surface in contact with the nut. A coupling current was recorded when the exposed surface(BCSE) was electrically connected with the contact surface(CCSE);with the CCSE acting as the anode thereby suppressing the corrosion process in the exposed surface. By implication, the galvanic coupling between CCSE and BCSE increased the corrosion rate of CCSE. The diff erence in oxygen supply was responsible for the coupling effect observed in the system as there was no decrease in the solution pH. Moreover, varying the cathode-to-anode area( S c/S a) ratio significantly influenced the corrosion current density as increased S c/S a ratio resulted in an accelerated galvanic corrosion process. The corroded surfaces and interfaces were analysed using stereomicroscopy and scanning electron microscopy. X-ray diff ractometry was adopted for corrosion product characterization. The results obtained showed supportive evidence of the corrosion behaviour in carbon steel fasteners.