期刊文献+
共找到237篇文章
< 1 2 12 >
每页显示 20 50 100
Engineered 3D ordered porous carbon anchored with ultrafine Ag nanoparticles via facile galvanic replacement for advanced electrochemical deionization
1
作者 Dun Wei Baixue Ouyang +6 位作者 Haoran Dong Peng Chen Tingzheng Zhang Bichao Wu Yingjie He Lei Huang Haiying Wang 《Journal of Energy Chemistry》 2025年第7期972-980,共9页
The capacitive deionization(CDI)performance of silver(Ag)electrodes is limited by electrochemical failure induced by volumetric expansion.While carbon encapsulation and Ag size control mitigate stress concentration an... The capacitive deionization(CDI)performance of silver(Ag)electrodes is limited by electrochemical failure induced by volumetric expansion.While carbon encapsulation and Ag size control mitigate stress concentration and pulverization,achieving precise size control,suppression of aggregation,and uniform dispersion of Ag nanoparticles remains challenging.Herein,the metal-organic frameworks(MOF)-assisted pyrolysis-galvanic replacement method was employed to construct ultrafine Ag particles uniformly anchored within a three-dimensional(3D)-ordered porous carbon skeleton composite(3D Ag@NC).By utilizing the potential difference between the elements,spontaneous replacement reactions occur,effectively preventing particle agglomeration usually caused by high-temperature reduction.The in situ constructed 3D porous carbon skeleton not only promotes electron transfer and electrolyte penetration but also mitigates the volume expansion of Ag particles during electrochemical cycling.Consequently,3D Ag@NC demonstrates outstanding dechlorination performance(105.29 mg g^(-1)),high charge efficiency(0.95),and exceptional cycling stability(84.12% after 100 cycles).This galvanic replacement strategy offers valuable insights into the fabrication of other small-sized,highly dispersed metal electrode materials. 展开更多
关键词 Capacitive deionization Silver Electrochemical failure Volume expansion galvanic replacement
在线阅读 下载PDF
Real-time electrochemical monitoring sensor for pollutant degradation through galvanic cell system
2
作者 Wu-Xiang Zhang Zi-Han Li +6 位作者 Rong-Sheng Xiao Xin-Gang Wang Hong-Liang Dai Sheng Tang Jian-Zhong Zheng Ming Yang Sai-Sai Yuan 《Rare Metals》 2025年第3期1800-1812,共13页
Here,a novel real-time monitoring sensor that integrates the oxidation of peroxymonosulfate(PMS)and the in situ monitoring of the pollutant degradation process is proposed.Briefly,FeCo@carbon fiber(FeCo@CF)was utilize... Here,a novel real-time monitoring sensor that integrates the oxidation of peroxymonosulfate(PMS)and the in situ monitoring of the pollutant degradation process is proposed.Briefly,FeCo@carbon fiber(FeCo@CF)was utilized as the anode electrode,while graphite rods served as the cathode electrode in assembling the galvanic cell.The FeCo@CF electrode exhibited rapid reactivity with PMS,generating reactive oxygen species that efficiently degrade organic pollutants.The degradation experiments indicate that complete bisphenol A(BPA)degradation was achieved within 10 min under optimal conditions.The real-time electrochemical signal was measured in time during the catalytic reaction,and a linear relationship between BPA concentration and the real-time charge(Q)was confirmed by the equation ln(C0/C)=4.393Q(correlation coefficients,R^(2)=0.998).Furthermore,experiments conducted with aureomycin and tetracycline further validated the effectiveness of the monitoring sensor.First-principles investigation confirmed the superior adsorption energy and improved electron transfer in FeCo@CF.The integration of pollutant degradation with in situ monitoring of catalytic reactions offers promising prospects for expanding the scope of the monitoring of catalytic processes and making significant contributions to environmental purification. 展开更多
关键词 galvanic cell DEGRADATION Catalytic progress Real-time monitoring
原文传递
Electrochemistry and DFT study of galvanic interaction on the surface of monoclinic pyrrhotite(001)and galena(100)
3
作者 Tingsheng Qiu Kaiwei Ding +4 位作者 Huashan Yan Liu Yang Hao Wu Guanfei Zhao Xianhui Qiu 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第8期1151-1162,共12页
The electrochemical interaction between galena and monoclinic pyrrhotite was investigated to examine its impact on the physical and chemical properties of the mineral micro-surface.This investigation employed techniqu... The electrochemical interaction between galena and monoclinic pyrrhotite was investigated to examine its impact on the physical and chemical properties of the mineral micro-surface.This investigation employed techniques such as electrochemistry,metal ion stripping,X-ray photoelectron spectroscopy,and quantum chemistry.The electrochemical test results demonstrate that the galena surface in the electro-couple system exhibits a lower electrostatic potential and higher electrochemical activity compared to the monoclinic pyrrhotite surface,rendering it more susceptible to oxidation dissolution.Monoclinic pyrrhotite significantly amplifies the corrosion rate of the galena surface.Mulliken charge population calculations indicate that electrons are consistently transferred from galena to monoclinic pyrrhotite,with the number of electron transfers on the mineral surface increasing as the interaction distance decreases.The analysis of state density revealed a shift in the surface state density of galena towards lower energy levels,resulting in decreased reactivity and increased difficulty for the reagent to adsorb onto the mineral surface.Conversely,monoclinic pyrrhotite exhibited an opposite trend.The X-ray photoelectron spectroscopy(XPS)test results indicate that galvanic interaction leads to the formation of hydrophilic substances,PbS_(x)O_(y) and Pb(OH)_(2),on the surface of galena.Additionally,the surface of monoclinic pyrrhotite not only adsorbs Pb^(2+)but also undergoes S^(0) formation,thereby augmenting its hydrophobic nature. 展开更多
关键词 ELECTROCHEMISTRY galvanic interaction Monoclinic pyrrhotite GALENA Density functional theory
在线阅读 下载PDF
Galvanic corrosion behavior of AZ91D alloy/45 steel couple under magnetic field
4
作者 Xin Zhang Wan Mei +4 位作者 Zehua Zhou Shaoqun Jiang Gang Wang Xiangru Shi Zehua Wang 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第9期3794-3805,共12页
Galvanic corrosion behavior of AZ91D alloy/45 steel couple in 3.5 wt.%NaCl solution under 0,0.2 and 0.4 T magnetic field were studied by microstructure observation,immersion test and electrochemical measurement.The mi... Galvanic corrosion behavior of AZ91D alloy/45 steel couple in 3.5 wt.%NaCl solution under 0,0.2 and 0.4 T magnetic field were studied by microstructure observation,immersion test and electrochemical measurement.The mixed potential theory was used to estimate the galvanic current density and the mixed potential of the galvanic corrosion between AZ91D alloy and 45 steel.The results indicated that magnetic field could accelerate the corrosion of AZ91D alloy,and impede the corrosion process of 45 steel.The effect of magnetic field on corrosion sensibility and corrosion rate of these two alloys increased as the intensity rising.The galvanic corrosion rate of the couple was accelerated by magnetic field.With the magnetic field intensity rising,the galvanic corrosion sensibility and corrosion rate of the couple increased.The effects of magnetic field on the galvanic corrosion performance of the couple and the corrosion behavior of AZ91D alloy and 45 steel were due to the appearance of field gradient force and magnetohydrodynamic(MHD)force.The mixed potential theory has a certain accuracy to estimate the Ecouple and icouple values in this work. 展开更多
关键词 Magnetic field Corrosion behavior galvanic corrosion The mixed potential theory
在线阅读 下载PDF
Galvanic corrosion behavior of copper/titanium galvanic couple in artificial seawater 被引量:19
5
作者 杜小青 杨青松 +2 位作者 陈宇 杨洋 张昭 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第2期570-581,共12页
The corrosion behaviors of copper and copper/titanium galvanic couple (GC) in seawater were studied by electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques in conjunction with s... The corrosion behaviors of copper and copper/titanium galvanic couple (GC) in seawater were studied by electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) techniques in conjunction with scanning electron microscopy (SEM) method. The results show that the corrosion process of copper in seawater can be divided into two stages, in which corrosion resistance and SE show the same evolution trend of initial increase and subsequent decrease, while SG changes oppositely. However, the ensemble corrosion process of copper/titanium GC in seawater includes three stages, in which corrosion resistance and SE show the evolution features of initial decrease with a subsequently increase, and the final decrease again;while SG changes oppositely. The potential difference between copper and titanium in their galvanic couple can accelerate the initiation of pitting corrosion of copper, and both the minimum and maximum corrosion potentials of copper/titanium GC are much more positive than those of pure copper. 展开更多
关键词 Cu/Ti galvanic couple galvanic corrosion electrochemical impedance spectroscopy electrochemical noise
在线阅读 下载PDF
Galvanic Skin Response—Extinction Biofeedback Training for Psychogenic Abdominal Pain: A Validation Protocol
6
作者 Maddalena Castelletti Enrico Berné +2 位作者 Erasmo Dionigio Carlo Castagnoli Alberto Montagna Giorgio Tonon 《Journal of Biosciences and Medicines》 2024年第5期190-201,共12页
Abdominal and pelvic pain of psychogenic origin is a widespread, disabling, difficult to identify, and often inadequately treated medical condition. This condition is often associated with poor quality of life due to ... Abdominal and pelvic pain of psychogenic origin is a widespread, disabling, difficult to identify, and often inadequately treated medical condition. This condition is often associated with poor quality of life due to high pain interference with daily activities. Cognitive behavioral psychological therapy and neuromodulation with biofeedback are validated therapies for the treatment of this condition. Aim of the present research work is the validation of a therapeutic protocol that involves the use of both techniques in combination. 20 patients diagnosed with psychogenic abdominal pain, of both sexes, aged between 18 and 60 years who had not benefited from pharmacological therapies were enrolled. 10 patients were randomly assigned to the control group (psychological treatment only), another 10 patients were assigned to the study group (neuromodulation with biofeedback-Galvanic skin response-extinction in combination with psychological therapy). For both groups, the pain score, interference of pain with daily living activities, pain relief, and the share of anxiety associated with the pain condition were evaluated (pre- and post-treatment). The patients who underwent the combined treatment achieved statistically significant better scores than patients in the control group, respectively −4.9 ± 0.9 vs −1.0 ± 0.4 for Pain;−5.1 ± 1.1 vs −0.9 ± 0.3 for Interference with life;−7.2 ± 3.7 vs −2.2 ± 2.1 for HAMA;4.6 ± 1.2 vs 1.1 ± 0.6 for Relief. 展开更多
关键词 Chronic Abdominal and Pelvic Psychogenic Pain (PAP) Biofeedback Training Pain Management galvanic Skin Response (GSR)
暂未订购
Effects of galvanic interaction between galena and pyrite on their flotation in the presence of butyl xanthate 被引量:7
7
作者 覃文庆 王兴杰 +3 位作者 马丽媛 焦芬 刘瑞增 高科 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第9期3111-3118,共8页
The effects of galvanic interaction between galena and pyrite on their flotation and electrochemical characters were studied by electrochemical,adsorption,flotation and FTIR techniques,respectively.Electrochemical tes... The effects of galvanic interaction between galena and pyrite on their flotation and electrochemical characters were studied by electrochemical,adsorption,flotation and FTIR techniques,respectively.Electrochemical tests indicate that galena is electrochemically more active than pyrite and serves as an anode in galvanic combination with pyrite.The galvanic current density from a mixture of galena and pyrite is 4 times as high as the self corrosion current density of galena,which indicates that the corrosion rate of galena is accelerated.Adsorption tests show that the adsorption of butyl xanthate on galena surface is enhanced,and affected by a combination of pyrite-galena mixtures and conditioning time.Compared with individual mineral particles,galvanic interaction reduces the floatability difference between galena and pyrite.The flotation recovery of galena decreases while that of pyrite increases when two minerals are mixed together due to the influence of galvanic interaction on the formation of hydrophilic/hydrophobic product.The FTIR results show that the formation of dixanthogen on pyrite surface is depressed due to the galvanic interaction. 展开更多
关键词 galvanic interaction GALENA PYRITE butyl xanthate FLOTATION
在线阅读 下载PDF
Galvanic corrosion behavior of die cast AZ91D magnesium alloy in chloride solution 被引量:2
8
作者 ZhensongTong WeiZhang JiuqingLi JinGao JiquanHe JiZhou 《Journal of University of Science and Technology Beijing》 CSCD 2004年第2期127-132,共6页
: The galvanic corrosion behavior of die cast AZ91D magnesium alloy coupled with H62 brass, 316L stainless steel, A3 steel and LY12 aluminum alloy of different areas in 3.5% NaCl solution was studied. The free corrosi... : The galvanic corrosion behavior of die cast AZ91D magnesium alloy coupled with H62 brass, 316L stainless steel, A3 steel and LY12 aluminum alloy of different areas in 3.5% NaCl solution was studied. The free corrosion potentials, galvanic potentials and currents of these galvanic couples were measured. The galvanic effects were determined by the mass loss and regression method using three points. The results show that: (1) In these four kinds of couples AZ91D acts as the anode, whose galvanic corrosion behavior is mainly controlled by the cathodic polarization; (2) The free corrosion potentials of these four kinds of couples change a little with time and cathodic/anodic area ratio (CAAR); (3) The galvanic potential of AZ91D/LY12 moves positively with the increase of time and CAAR; (4) The galvanic currents increase with CAAR, but there is difference in the current change between different couples; (5) The anodic dissolution rate of the magnesium alloy increases by 2-3 orders after being coupled with these four kinds of metals and the galvanic effects of these couples have such a relation as γH62> γ316L.S.S>γLY12>γA3. 展开更多
关键词 magnesium alloy galvanic corrosion galvanic effect
在线阅读 下载PDF
Quick selection of aluminum galvanic anodes in oil brine via galvanic current
9
作者 HAO Xiao-jun LEI Ying-chun +2 位作者 HOU Hua ZHAO Yu-hong WANG Yi-du 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第4期334-339,共6页
According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic... According to dynamics of coupled galvanic anode with carbon steel,the integral of galvanic current vs.time is approximately equal to actual current capacity of galvanic anode.Galvanic current of cast aluminum galvanic anode coupled with carbon steel is tested in3.5%NaCl solution and ambient temperature.Rapid evaluation the performance of galvanic anode using galvanic current is feasible,and the test time is20min.The galvanic current is used to select aluminum galvanic anodes in oil brine,and then test the galvanic anodes with impressed current test method.The result shows,the performance of galvanic anodes degrads in oil brine,but has not much difference in the two media to the preferable anodes,and the optimal galvanic anode is gained. 展开更多
关键词 quick selection aluminum galvanic anode galvanic current oil brine
在线阅读 下载PDF
Galvanic反应原位制备多金属氢氧化物用于OER催化 被引量:1
10
作者 刘云花 肖丹 《化学研究与应用》 CAS CSCD 北大核心 2021年第7期1331-1337,共7页
采用镍氨和钴氨为电解液电沉积金属钴镍,提高材料的比表面积和导电性,再通过Galvanic反应快速合成了金属钴镍复合钴镍铁氢氧化物(CoNi/CoNiFe H)催化剂用于OER催化,采用XRD、SEM、XPS对材料的结构、形貌进行了表征,并研究了其电化学性... 采用镍氨和钴氨为电解液电沉积金属钴镍,提高材料的比表面积和导电性,再通过Galvanic反应快速合成了金属钴镍复合钴镍铁氢氧化物(CoNi/CoNiFe H)催化剂用于OER催化,采用XRD、SEM、XPS对材料的结构、形貌进行了表征,并研究了其电化学性能。结果表明:在1 M KOH溶液中,电流密度为10 mA·cm^(-2)时,过电位仅有250 mV,Tafel斜率为29 mV·dec^(-1),且具有良好的稳定性。这为制备廉价的多金属复合材料用于高效OER催化提供了新的方法。 展开更多
关键词 galvanic反应 原位生长 多金属氢氧化物 OER
在线阅读 下载PDF
Effect of corrosive media on galvanic corrosion of complicated tri-metallic couples of 2024 Al alloy/Q235 mild steel/304 stainless steel 被引量:11
11
作者 Linjun Shi Xiuying Yang +4 位作者 Yingwei Song Dan Liua Kaihui Dong Dayong Shan En-Hou Han 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2019年第9期1886-1893,共8页
Galvanic corrosion of tri-metallic couples is more complicated than that of bi-metallic couples. In this study, the effect of the pH of corrosive media on the galvanic corrosion of 2024 A1 alloy/Q235 mild steel/304 st... Galvanic corrosion of tri-metallic couples is more complicated than that of bi-metallic couples. In this study, the effect of the pH of corrosive media on the galvanic corrosion of 2024 A1 alloy/Q235 mild steel/304 stainless steel tri-metallic couples was investigated using potentiodynamic polarization, scanning electron microscopy, scanning vibrating electrode technique and a multi-channel galvanic corrosion meter. The results show that 2024 always acts as the only anode in 3.5 wt% NaCl at pH 5.56,9.72 and 12.0, while both Q235 and 2024 act as anodes at pH 2.39 in the initial stage and then the role of Q235 changes at longer coupling time, which can be attributed to the effect of pH on the surface film of 2024. It is also found that the galvanic current density of a tri-metallic couple is the superposition of two bi-metallic couples when cathodic reactions are controlled by the diffusion of oxygen, otherwise it is smaller than that of the sum of two bi-metallic couples. The localized corrosion instead of uniform corrosion of anodic metal is accelerated by galvanic corrosion. 展开更多
关键词 galvanic corrosion Tri-metallic couples Corrosive MEDIA Scanning vibrating electrode technique Zero resistance AMMETER
原文传递
Galvanic Corrosion Behaviour of Aluminium 3004 and Copper in Tropical Marine Atmosphere 被引量:11
12
作者 G. Subramanian S. Palraj S. Palanichamy 《Journal of Marine Science and Application》 2014年第2期230-236,共7页
The galvanic corrosion behaviour of aluminium 3004 and copper with different area ratios were studied in the tropical marine atmosphere at Tuticorin harbour over a period of 426 days. The area ratios OfAAI: Acu, stud... The galvanic corrosion behaviour of aluminium 3004 and copper with different area ratios were studied in the tropical marine atmosphere at Tuticorin harbour over a period of 426 days. The area ratios OfAAI: Acu, studied were l:l, 1:2, l:4, 1:8, 2:1, 4:1 & 8:1. The galvanic corrosion behaviour of metals was studied in terms of relative increase in the corrosion rate of aluminium due to galvanic coupling with copper, relative decrease in the corrosion rate of copper due to galvanic coupling with aluminium, and the susceptibility of aluminium to pitting owing to galvanic coupling with copper, The galvanic potential and galvanic current of the system were monitored. Pits of different dimensions ranging from mild etchings to perforations were experienced on the borders and the surfaces of the interface of aluminium in contact with copper. The weathering parameters and the environmental pollutants which have a major role in influencing the galvanic corrosion of metals were also monitored. The corrosion products resulting from galvanic corrosion were analysed using XRD and the pitting on aluminium resulting from galvanic corrosion has been highlighted in terms of pit depth, size and density of pit, using a high resolution microscope. 展开更多
关键词 aluminium 3004 COPPER galvanic corrosion corrosionproducts PITTING tropical marine atmosphere
在线阅读 下载PDF
A novel PdNi/Al_2O_3 catalyst prepared by galvanic deposition for low temperature methane combustion 被引量:8
13
作者 Xiqiang Pan Yibo Zhang +1 位作者 Zhenzhen Miao Xiangguang Yang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2013年第4期610-616,共7页
Galvanic deposition method was used to prepare the Pd/Ni-Al2O3-GD catalyst for the combustion of methane under lean conditions. The new catalyst and compared catalysts (Pd/Al2O3-IW, Pd-Ni/Al2O3-IW, Pd/Ni-Al2O3-IW) p... Galvanic deposition method was used to prepare the Pd/Ni-Al2O3-GD catalyst for the combustion of methane under lean conditions. The new catalyst and compared catalysts (Pd/Al2O3-IW, Pd-Ni/Al2O3-IW, Pd/Ni-Al2O3-IW) prepared by incipient wetness impregnation were characterized by N2-physisorption, XRD and TEM to clarify particle size and size distribution of palladium species. Combined O2-TPD and XPS results with the catalytic data, it shows that the surface palladium species with low valence exhibits better combustion performance due to their stronger interaction with support. The results indicate that the galvanic deposition method is an effective route to prepare efficient catalyst for methane combustion, and it also provides useful information for improving the present commercial catalyst. 展开更多
关键词 METHANE catalytic combustion PALLADIUM PD/AL2O3 galvanic replace reaction
在线阅读 下载PDF
Understanding the galvanic corrosion of the Q-phase/Al couple using SVET and SIET 被引量:4
14
作者 Alexander I.Ikeuba Bo Zhang +2 位作者 Jianqiu Wang En-Hou Han Wei Ke 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2019年第7期1444-1454,共11页
The galvanic corrosion of the Q-phase/Al couple in 0.1 M NaCl solutions has been studied using the scanning vibrating electrode technique (SVET)f the scanning ion-selective electrode technique (SIET) and energy disper... The galvanic corrosion of the Q-phase/Al couple in 0.1 M NaCl solutions has been studied using the scanning vibrating electrode technique (SVET)f the scanning ion-selective electrode technique (SIET) and energy dispersive X-ray spectroscopy (EDX). The galvanic corrosion of the Q-phase/Al couple was found to be dependent on pH and immersion time. Current density maps obtained by SVET shows that the anodic oxidation processes emerge from Al in a localized manner in pH 2 and 6 solutions but is initiated in a uniform manner in pH 13 solution, whereas, the cathodic processes are more homogeneously distributed over the Q-phase at pH 2.6 and 13. It is seen that the Q-phase remains cathodic in the Q-phase/Al couple in acidic, neutral and alkaline solutions indicating that the galvanic polarity of the Q-phase is independent of pH. The effect of the galvanic corrosion was largest at pH 2 and 13 compared to pH 6. The pH map obtained by SIET indicates that the galvanic activity of the Q-phase/Al couple proceeds via heavy alkalization of the Q-phase surface with the generation of appreciable amounts of OH~ ions. The enrichment of Cu indicated by EDX is responsible for the observed cathodic activity of the Q-phase in the Q-phase/Al couple. 展开更多
关键词 Q-phase galvanic corrosion SCANNING vibrating ELECTRODE TECHNIQUE (SVET) SCANNING ion-selective ELECTRODE TECHNIQUE (SIET) Energy dispersive X-ray spectroscopy (EDX)
原文传递
A study on vestibular-evoked myogenic potentials via galvanic vestibular stimulation in normal people 被引量:4
15
作者 Ying Cheng Yusuke Kimura Kimitaka Kaga 《Journal of Otology》 CSCD 2018年第1期16-19,共4页
Objectives: The aim of our study is to examine vestibular-evoked myogenic potentials(VEMPs) elicited by the galvanic vestibular stimulation in the sternocleidomastoid muscle(SCM) in healthy subjects for clinical appli... Objectives: The aim of our study is to examine vestibular-evoked myogenic potentials(VEMPs) elicited by the galvanic vestibular stimulation in the sternocleidomastoid muscle(SCM) in healthy subjects for clinical applications of auditory neuropathy or vestibular neuropathy in the future.Methods: We enrolled sixteen healthy subjects to record the average responses of SCM to galvanic vestibular stimulation(GVS) [current 3 mA;duration 1 ms] by electromyography(EMG). SPSS 18.0 software was used to analyze the obtained data for mean and standard deviation.Results: In all healthy subjects mastoid-forehead galvanic vestibular stimulation produced a positive-negative biphasic EMG responses on SCM ipsilateral to the cathodal electrode. The latency of p13 was 11.7 ± 3.0 ms. The latency of n23 was 17.8 ± 3.4 ms. The amplitude of p13-n23 was147.0 ± 69.0 μV. The interaural asymmetry ratio(AR) of p13, n23 latency and the amplitude was respectively 0.12 ± 0.09, 0.08 ± 0.08 and0.16 ± 0.10.Discussions: Galvanic vestibular stimulation could elicit biphasic EMG responses from SCM via the vestibular nerve but not from the otolith organs. Galvanic stimulation together with air conducted sound(ACS) or bone conducted vibration(BCV) can elicit VEMPs and may enable the differentiation of retrolabyrinthine lesions from labyrinthine lesions in vestibular system. 展开更多
关键词 galvanic VESTIBULAR stimulation VESTIBULAR nerve Vestibular-evoked MYOGENIC POTENTIALS STERNOCLEIDOMASTOID muscle INTERAURAL asymmetry ratio (AR)
暂未订购
Microstructure induced galvanic corrosion evolution of SAC305 solder alloys in simulated marine atmosphere 被引量:5
16
作者 Mingna Wang Chuang Qiao +2 位作者 Xiaolin Jiang Long Hao Xiahe Liu 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2020年第16期40-53,共14页
Motivated by the increasing use of Sn-3.0 Ag-0.5 Cu(SAC305)solder in electronics worked in marine atmospheric environment and the uneven distribution of Ag3Sn and Cu6Sn5 intermetallic compounds(IMCs)inβ-Sn matrix,com... Motivated by the increasing use of Sn-3.0 Ag-0.5 Cu(SAC305)solder in electronics worked in marine atmospheric environment and the uneven distribution of Ag3Sn and Cu6Sn5 intermetallic compounds(IMCs)inβ-Sn matrix,comb-like electrodes have been designed for in-situ EIS measurements to study the microstructure induced galvanic corrosion evolution of SAC305 solder in simulated marine atmosphere with high-temperature and high-humidity.Results indicate that in-situ EIS measurement by comb-like electrodes is an effective method for corrosion evolution behavior study of SAC305 solder.Besides,the galvanic effect between Ag3Sn IMCs andβ-Sn matrix can aggravate the corrosion of both as-received and furnace-cooled SAC305 solder as the exposure time proceeds in spite of the presence of corrosion product layer.Pitting corrosion can be preferentially found on furnace-cooled SAC305 with larger Ag3Sn grain size.Moreover,the generated inner stress during phases transformation process with Sn3O(OH)2Cl2 as an intermediate and the possible hydrogen evolution at local acidified sites are supposed to be responsible for the loose,porous,cracked,and non-adherent corrosion product layer.These findings clearly demonstrate the corrosion acceleration behavior and mechanism of SAC305 solder,and provide potential guidelines on maintenance of microelectronic devices for safe operation and longer in-service duration. 展开更多
关键词 SAC305 solder Marine atmosphere galvanic corrosion In-situ EIS Comb-like electrode
原文传递
GALVANIC CORROSION AND PROTECTION OF GECM/LY12CZ COUPLES UNDER DIFFERENT ATMOSPHERIC EXPOSURE CONDITIONS 被引量:5
17
作者 F.Lu Q.P.Zhong 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第1期41-45,共5页
Galvanic, compatibility between graphite epoxy composite materials (GECM) and LY12CZ aluminum alloy was evaluated in different atmospheric corrosion environments and by laboratory electrochemical measurements. Open ci... Galvanic, compatibility between graphite epoxy composite materials (GECM) and LY12CZ aluminum alloy was evaluated in different atmospheric corrosion environments and by laboratory electrochemical measurements. Open circuit potential electrochemical measurements showed a relatively large potential difference about 1 volt between the GECM and LY12CZ aluminum alloy, and this difference provided the driving force for galvanic corrosion of the LY12CZ aluminum alloy as an anode. Having been exposed for 1, 3 or 5 years in Beijing, Tuandao and Wanning station, GECM/LY12CZ couples showed significant losses of strength and elongation. Protective coatings and non-conductive barriers breaking the galvanic corrosion circuit were evaluated under the same atmospheric corrosive conditions. Epoxy primer paint, glass cloth barriers and LY12CZ anodizing were effective in galvanic corrosion control for GECM/LY12CZ couples. 展开更多
关键词 galvanic corrosion graphite epoxy composite material atmospheric corrosion PROTECTION
在线阅读 下载PDF
A new method to determine the synergistic effects of area ratio and microstructure on the galvanic corrosion of LAS A508/309 L/308 L SS dissimilar metals weld 被引量:4
18
作者 Bright O.Okonkwo Hongliang Ming +4 位作者 Jianqiu Wang En-Hou Han Ehsan Rahimi Ali Davoodi Saman Hosseinpour 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2021年第19期38-50,共13页
The synergistic effects of area ratio and microstructure on the galvanic corrosion of A508/309 L/308 L dissimilar metals weld(DMW)are studied by a multi-analytical approach.It was demonstrated that decreasing the anod... The synergistic effects of area ratio and microstructure on the galvanic corrosion of A508/309 L/308 L dissimilar metals weld(DMW)are studied by a multi-analytical approach.It was demonstrated that decreasing the anode/cathode surface area ratio obviously enhances the corrosion rate of A508,both locally and globally.Deeper analyses of the AFM results enabled quantitative comparison of the corrosion behaviour of the different surface constituents.It was revealed that in the galvanic interaction of the DMW,the grain refined region corrodes most,followed by the partial grain refined region and base metal matrix of the A508,respectively.The electrochemical localization index(LI)estimation method and AFM analysis both confirmed the presence of a mixed(localized and uniform)corrosion phenomenon occurring on the surface of the A508 anode metal in the galvanic interaction of the dissimilar metals.Finally,the degree of synergism equation was utilized to describe the synergistic effects of anode/cathode area ratio and the microstructure of the samples on the galvanic corrosion of LAS A508/309 L/308 L SS DMW. 展开更多
关键词 Low alloy steel Stainless steel SEM AFM galvanic corrosion INCLUSION
原文传递
Galvanic Effect Between Galvanized Steel and Carbon Fiber Reinforced Polymers 被引量:4
19
作者 Chi Zhang Da-Jiang Zheng Guang-Ling Song 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2017年第4期342-351,共10页
The galvanic corrosion behavior of carbon fiber reinforced polymers (CFRPs) GM-CFRP and Tepex-CFRP in contact with a Zn-coated DP590 steel in solution containing 0.9 wt% NaCl+ 0.1 wt% CaCl2 + 0.075 wt% NaHCO3 was ... The galvanic corrosion behavior of carbon fiber reinforced polymers (CFRPs) GM-CFRP and Tepex-CFRP in contact with a Zn-coated DP590 steel in solution containing 0.9 wt% NaCl+ 0.1 wt% CaCl2 + 0.075 wt% NaHCO3 was investigated. The results showed that the GM-CFRP/steel couple was initially more resistant to galvanic corrosion, but its galvanic corrosion activity gradually became higher than the Tepex-CFRP/steel couple. The different galvanic behaviors of these two couples were discussed based on the electrochemical performance of GM-CFRP, Tepex-CFRP and DP590 coupons in the testing solution. 展开更多
关键词 Carbon fiber reinforced polymer (CFRP) COMPOSITE Carbon fiber STEEL galvanic effect
原文传递
Galvanic Corrosion Behavior of Copper-Drawn Steel for Grounding Grids in the Acidic Red Soil Simulated Solution 被引量:4
20
作者 Xiao-Lei Fan Yun-Xiang Chen +3 位作者 Jun-Xi Zhang De-Yuan Lin Xuan-Xuan Liu Xiao-Jian Xia 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2020年第11期1571-1582,共12页
The influence of pH and metallographic structure on the corrosion behavior of copper-drawn steel is studied with the simulated system.The effect of pH on the corrosion behavior of copper-drawn steel has been investiga... The influence of pH and metallographic structure on the corrosion behavior of copper-drawn steel is studied with the simulated system.The effect of pH on the corrosion behavior of copper-drawn steel has been investigated using open-circuit potential,potentiodynamic polarization,galvanic current measurement,scanning electron microscopy and scanning vibrating electrode technique techniques.The steel is corroded as anode,while the corrosion of copper plate is protected as cathode.All the results revealed that pH and metallographic structure had a significant influence on the corrosion behavior of copper-drawn steel.With the decrease in pH value from 6 to 2.4,the corrosion rate of copper-drawn steel galvanic couple(Cu-Fe GC)obviously increased in the simulated solution of acidic red soil.The electric field formed by the Cu-Fe GC changes the direction of ion migration between the copper and drawn steel electrodes,which impacts the composition and microstructure of corrosion products formed on the electrode surface. 展开更多
关键词 Cu-Fe galvanic couple Electrochemical test Scanning vibrating electrode technique(SVET)measurement Soil corrosion
原文传递
上一页 1 2 12 下一页 到第
使用帮助 返回顶部