In this paper, we present a theoretical study on the discharge characteristics of radio-frequency discharges at atmospheric pressure driven by a higher frequency of 40.68 MHz while the electrode gap is altered. Based ...In this paper, we present a theoretical study on the discharge characteristics of radio-frequency discharges at atmospheric pressure driven by a higher frequency of 40.68 MHz while the electrode gap is altered. Based on the analytical equations and simulation data from a one-dimensional fluid model, an optimal gap between electrodes, at which the largest electron density is obtained, can be observed under a constant power condition; however, as the electrode gap increases the time-averaged electron temperature decreases, and the underpinning physics is also discussed based on the simulation results. This study indicates that at a constant power by choosing an appropriate electrode spacing, the rf discharge can be effectively optimized at atmospheric pressure.展开更多
Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-freque...Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearing- threshold-weighted values (HFTWVs). Methods: A retrospective study was conducted to evaluate the diagnosis of patients with ONID from January 2016 to January 2017 in Guangdong province, China. Based on 3 hearing tests (each interval between the tests was greater than 3 days), the minimum threshold value of each frequency was obtained using the 2007 edition’s diagnostic criteria for ONID. The speech frequency and the HFTWVs were analyzed based on age, noise exposure, and diagnostic classi-fication using SPSS21.0. Results: 168 patients in total were involved in this study, 154 males and 14 females, and the average age was 41.18 ± 6.07. The diagnosis rate was increased by the weighted value of the high frequencies and was more than the mean value of the pure speech frequency (MVPSF). The diagnosis rate for the weighted 4 kHz frequency level increased by 13.69% (χ2 = 9.880, P = 0.002), the weighted 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002), and the weighted 4 kHz + 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002). The differences were all statistically significant. The diagnostic rate of the different thresholds showed no obvious difference between the genders. The age groups were divided into less than or equal to 40 years old (group A) and 40 - 50 years old (group B). There were several groups with a high frequency: high frequency weighted 4 kHz ( group A χ2 = 3.380, P = 0.050;group B χ2 = 4.054, P = 0.032), high frequency weighted 6 kHz (group A χ2 = 6.362, P = 0.012;group B χ2 = 4.054, P = 0.032), weighted 4 kHz + 6 kHz (group A χ2 = 6.362 P = 0.012;B χ2 = 4.054, P = 0.032) than those of MVPSF in the same group on ONID diagnosis rate. The differences between the groups were statistically significant. There was no significant difference between the age groups (χ2 = 2.265, P = 0.944). The better ear’s (the smaller hearing threshold weighted value) MVPSF and the weighted values for the different high frequencies were examined in light of the number of working years;the group that was exposed to noise for more than 10 years had significantly higher values than those of the average thresholds of each frequency band in the groups with 3 - 5 years of exposure (F = 2.271, P = 0.001) and 6 - 10 years of exposure (F = 1.563, P = 0.046). The differences were statistically significant. The different HFTWVs were higher than those of the MVPSF values, and the high frequency weighted 4 kHz + 6 kHz level showed the greatest difference, with an average increase of 2.83 dB. The diagnostic rate that included the weighted high frequency values was higher for the mild, moderate, and severe cases than those patients who were only screened with the pure frequency tests. The results of the comparisons of the diagnosis rates for mild ONID were as follows: the weighted 3 kHz high frequency level (χ2 = 3.117, P = 0.077) had no significant difference, but the weighted 4 kHz level (χ2 = 10.835, P = 0.001), 6 kHz level (χ2 = 9.985, P = 0.002), 3 kHz + 4 kHz level (χ2 = 6.315, P = 0.012), 3 kHz + 6 kHz level (χ2 = 6.315, P = 0.012), 4 kHz + 6 kHz level (χ2 = 9.985, P = 0.002), and 3 kHz + 4 kHz + 6 kHz level (χ2 = 7.667, P = 0.002) were significantly higher than the diagnosis rate of the mean value of the PSF. There was no significant difference between the 2 groups for the moderate and severe grades (P > 0.05). Conclusion: Different HFTWVs increase the diagnostic rate of ONID. The weighted 4 kHz, 6 kHz, and 4 kHz + 6 kHz high frequency values greatly affected the diagnostic results, and the weighted 4 kHz + 6 kHz high frequency hearing threshold value has the maximum the effect on the ONID diagnosis results.展开更多
Two deep-sea moorings were deployed respectively in the east area and the west area of Chinese Pioneer Area (CPA) in the tropic east Pacific to monitor the regional deep-sea dynamics below 600 meters above bottom (mab...Two deep-sea moorings were deployed respectively in the east area and the west area of Chinese Pioneer Area (CPA) in the tropic east Pacific to monitor the regional deep-sea dynamics below 600 meters above bottom (mab) from July 1997 to Oct. 1999. Results of statistics, spectral estimate and correlation analysis of the low-passed velocity data show that time scales of low-frequency components of the near-bottom currents are 25~120 days, in which 51-day period dominates the lower band of the frequency domain. Topographic features have obvious effect on low-frequency currents below 50 mab; modulations of the bot-tom-intensified sheared mean flow to the low-frequency currents are the dynamic mechanism of the frequency shift that occurs in both the east-area and the west-area.展开更多
基金supported by National Natural Science Foundation of China(No.11375107)the Fundamental Research Funds of Shandong University of China(No.2012TS067)
文摘In this paper, we present a theoretical study on the discharge characteristics of radio-frequency discharges at atmospheric pressure driven by a higher frequency of 40.68 MHz while the electrode gap is altered. Based on the analytical equations and simulation data from a one-dimensional fluid model, an optimal gap between electrodes, at which the largest electron density is obtained, can be observed under a constant power condition; however, as the electrode gap increases the time-averaged electron temperature decreases, and the underpinning physics is also discussed based on the simulation results. This study indicates that at a constant power by choosing an appropriate electrode spacing, the rf discharge can be effectively optimized at atmospheric pressure.
文摘Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearing- threshold-weighted values (HFTWVs). Methods: A retrospective study was conducted to evaluate the diagnosis of patients with ONID from January 2016 to January 2017 in Guangdong province, China. Based on 3 hearing tests (each interval between the tests was greater than 3 days), the minimum threshold value of each frequency was obtained using the 2007 edition’s diagnostic criteria for ONID. The speech frequency and the HFTWVs were analyzed based on age, noise exposure, and diagnostic classi-fication using SPSS21.0. Results: 168 patients in total were involved in this study, 154 males and 14 females, and the average age was 41.18 ± 6.07. The diagnosis rate was increased by the weighted value of the high frequencies and was more than the mean value of the pure speech frequency (MVPSF). The diagnosis rate for the weighted 4 kHz frequency level increased by 13.69% (χ2 = 9.880, P = 0.002), the weighted 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002), and the weighted 4 kHz + 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002). The differences were all statistically significant. The diagnostic rate of the different thresholds showed no obvious difference between the genders. The age groups were divided into less than or equal to 40 years old (group A) and 40 - 50 years old (group B). There were several groups with a high frequency: high frequency weighted 4 kHz ( group A χ2 = 3.380, P = 0.050;group B χ2 = 4.054, P = 0.032), high frequency weighted 6 kHz (group A χ2 = 6.362, P = 0.012;group B χ2 = 4.054, P = 0.032), weighted 4 kHz + 6 kHz (group A χ2 = 6.362 P = 0.012;B χ2 = 4.054, P = 0.032) than those of MVPSF in the same group on ONID diagnosis rate. The differences between the groups were statistically significant. There was no significant difference between the age groups (χ2 = 2.265, P = 0.944). The better ear’s (the smaller hearing threshold weighted value) MVPSF and the weighted values for the different high frequencies were examined in light of the number of working years;the group that was exposed to noise for more than 10 years had significantly higher values than those of the average thresholds of each frequency band in the groups with 3 - 5 years of exposure (F = 2.271, P = 0.001) and 6 - 10 years of exposure (F = 1.563, P = 0.046). The differences were statistically significant. The different HFTWVs were higher than those of the MVPSF values, and the high frequency weighted 4 kHz + 6 kHz level showed the greatest difference, with an average increase of 2.83 dB. The diagnostic rate that included the weighted high frequency values was higher for the mild, moderate, and severe cases than those patients who were only screened with the pure frequency tests. The results of the comparisons of the diagnosis rates for mild ONID were as follows: the weighted 3 kHz high frequency level (χ2 = 3.117, P = 0.077) had no significant difference, but the weighted 4 kHz level (χ2 = 10.835, P = 0.001), 6 kHz level (χ2 = 9.985, P = 0.002), 3 kHz + 4 kHz level (χ2 = 6.315, P = 0.012), 3 kHz + 6 kHz level (χ2 = 6.315, P = 0.012), 4 kHz + 6 kHz level (χ2 = 9.985, P = 0.002), and 3 kHz + 4 kHz + 6 kHz level (χ2 = 7.667, P = 0.002) were significantly higher than the diagnosis rate of the mean value of the PSF. There was no significant difference between the 2 groups for the moderate and severe grades (P > 0.05). Conclusion: Different HFTWVs increase the diagnostic rate of ONID. The weighted 4 kHz, 6 kHz, and 4 kHz + 6 kHz high frequency values greatly affected the diagnostic results, and the weighted 4 kHz + 6 kHz high frequency hearing threshold value has the maximum the effect on the ONID diagnosis results.
文摘Two deep-sea moorings were deployed respectively in the east area and the west area of Chinese Pioneer Area (CPA) in the tropic east Pacific to monitor the regional deep-sea dynamics below 600 meters above bottom (mab) from July 1997 to Oct. 1999. Results of statistics, spectral estimate and correlation analysis of the low-passed velocity data show that time scales of low-frequency components of the near-bottom currents are 25~120 days, in which 51-day period dominates the lower band of the frequency domain. Topographic features have obvious effect on low-frequency currents below 50 mab; modulations of the bot-tom-intensified sheared mean flow to the low-frequency currents are the dynamic mechanism of the frequency shift that occurs in both the east-area and the west-area.