期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Superpixel-Based Complex Field Modulation Using a Digital Micromirror Device for Focusing Light through Scattering Media 被引量:1
1
作者 You-Quan Jia Qi Feng +3 位作者 Bin Zhang Wei Wang Cheng-You Lin Ying-Chun Ding 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第5期39-42,共4页
We present a digital micromirror device(DMD) based superpixel method for focusing light through scattering media by modulating the complex field of incident light. Firstly, we numerically and experimentally investig... We present a digital micromirror device(DMD) based superpixel method for focusing light through scattering media by modulating the complex field of incident light. Firstly, we numerically and experimentally investigate focusing light through a scattering sample using the superpixel methods with different target complex fields.Then, single-point and multiple-point focusing experiments are performed using this superpixel-based complex modulation method. In our experiment, up to 71.5% relative enhancement is realized. The use of the DMDbased superpixel method for the control of the complex field of incident light opens an avenue to improve the enhancement of focusing light through scattering media. 展开更多
关键词 DMD Superpixel-Based Complex Field Modulation Using a Digital Micromirror device for focusing Light through Scattering Media
原文传递
Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device 被引量:1
2
作者 Farzin M.Aghamir Reza A.Behbahani 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期375-380,共6页
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista... The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr). 展开更多
关键词 Mather-type plasma focus device hard X-rays multi-radiation tube multiple voltage peaks anomalous resistances
原文传递
Calibration of Activation Counter by a 2.48 kJ Plasma Focus Device
3
作者 S.R. Moghadam F.A. Davani B.S. Bidabadi 《Journal of Energy and Power Engineering》 2011年第12期1163-1167,共5页
In many experiments, plastic scintillators are used as a counter instead of Geiger Muller counter, because they are so fast and they are used for pulsed neutron sources. So a silver activation counter has been constru... In many experiments, plastic scintillators are used as a counter instead of Geiger Muller counter, because they are so fast and they are used for pulsed neutron sources. So a silver activation counter has been constructed by plastic scintillator plates along with silver foils for determination the neutron yield of a 2.48 kJ plasma focus device, SBUPF1. This counter was calibrated by source removal method with an Am-Be 5 Ci neutron source which was placed above the anode of plasma focus device. Deuterium gas up to 8 mbar pressure was injected to this device, and the neutron yield produced by pulsed D-D fusion of plasma focus device was measured by the counter. The neutron yield of SBUPF1 in 8 mbar pressure was obtained (3.71± 0.32)×10^7 neutrons per shot. This result has relatively agreed with the neutron yield measured by silver activation Geiger counters. 展开更多
关键词 Activation counter plasma focus device neutron yield.
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部