期刊文献+
共找到22,858篇文章
< 1 2 250 >
每页显示 20 50 100
Free Flow-through Anterolateral Thigh Flaps for Wrist High-tension Electrical Burns:A Retrospective Case Series 被引量:14
1
作者 WANG Cheng SHEN Yu Ming +1 位作者 QIN Feng Jun HU Xiao 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2020年第7期510-517,共8页
Objective The objective of this report was to demonstrate the clinical application of free flow-through anterolateral thigh flaps for the treatment of high-tension electrical wrist burns.Methods We collected the data ... Objective The objective of this report was to demonstrate the clinical application of free flow-through anterolateral thigh flaps for the treatment of high-tension electrical wrist burns.Methods We collected the data of 8 patients with high-tension electrical wrist burns admitted to Beijing Jishuitan Hospital from January 2014 to December 2018.The clinical and pathological data were extracted from electronic hospital medical records.We obtained follow-up information through clinic visits.Results The injury sites for all 8 patients were the wrists,specifically 5 right and 3 left wrists,all of which were on the flexor side.Five patients had ulnar artery embolism necrosis and patency,with injury to the radial artery.Two patients had ulnar and radial arterial embolization and necrosis.The last patient had ulnar arterial embolization and necrosis with a normal radial artery.After debridement,the wound area ranged from 12 cm×9 cm to 25 cm×16 cm.The diagnoses for the eight patients were type II to type III high-tension electrical wrist burns.Free flow-through anterolateral thigh flaps(combined with great saphenous vein transplantation if necessary)were used to repair the wounds.The prognosis for all patients was good after six months to one year of follow-up.Conclusion Treating wrist types II and III high-tension electrical burns is still challenging in clinical practice.The use of free flow-through anterolateral thigh flaps(combined with great saphenous vein transplantation if necessary)to repair the wound and to restore the blood supply for the hand at the same time is a good choice for treating severe wrist electrical burns. 展开更多
关键词 High-tension electrical burns Wrist flap surgery Free flow-through anterolateral thigh flaps
暂未订购
股前外侧-髂腹股沟联合Flow-through皮瓣修复下肢复杂性损伤
2
作者 殷国辉 赵威 赵建文 《中国修复重建外科杂志》 北大核心 2025年第9期1122-1127,共6页
目的探讨股前外侧-髂腹股沟联合Flow-through皮瓣修复下肢复杂性损伤的疗效。方法回顾性分析2018年1月—2024年1月收治的20例下肢复杂性损伤患者临床资料。其中男14例,女6例;年龄29~65岁,平均47.3岁。缺损原因:重物砸落7例,交通事故伤5... 目的探讨股前外侧-髂腹股沟联合Flow-through皮瓣修复下肢复杂性损伤的疗效。方法回顾性分析2018年1月—2024年1月收治的20例下肢复杂性损伤患者临床资料。其中男14例,女6例;年龄29~65岁,平均47.3岁。缺损原因:重物砸落7例,交通事故伤5例,机器碾压伤5例,骨髓炎3例。缺损部位:左侧7例,右侧13例;胫、腓骨损伤6例,单纯胫骨损伤6例,足踝部损伤5例,股骨合并胫骨损伤3例。软组织缺损范围23 cm×8 cm~44 cm×12 cm。采用股前外侧-髂腹股沟联合Flow-through皮瓣修复软组织缺损,皮瓣切取范围24 cm×10 cm~48 cm×14 cm。12例受区一期缝合;8例受区无可供吻合血管,采用交腿皮瓣形式建立临时血供,3~4周后二期断蒂。大腿供区均直接缝合。随访期间观察皮瓣成活、外观、质地等及相关并发症发生情况;采用温哥华瘢痕量表(VSS)评估皮瓣瘢痕情况,下肢功能评分(LEFS)评估患侧下肢功能,疼痛视觉模拟评分(VAS)评估患侧疼痛情况。结果术后除1例皮瓣完全坏死、1例边缘部分坏死、2例浅表感染、1例出现静脉血栓,其余皮瓣均顺利成活,创面Ⅰ期愈合。供区切口均Ⅰ期愈合。所有患者经治疗后均保肢成功;患者均获随访,随访时间12~24个月,平均18.4个月。末次随访时皮瓣色泽、质地及外形良好,骨折达到临床愈合标准。1例术后健侧出现屈髋、伸膝轻度受限,3例术后6个月仍感供区麻木、1例供区长期慢性疼痛。术后12个月患侧LEFS、VSS及VAS评分分别为(62.7±4.6)、(3.5±1.1)、(1.2±0.6)分,均优于术后1个月[(38.6±2.8)、(8.5±1.4)、(4.7±1.1)分],差异均有统计学意义(P<0.05)。结论股前外侧-髂腹股沟联合Flow-through皮瓣治疗下肢复杂性损伤是一种良好方法,患侧远端血运恢复良好,皮瓣成活率高,患肢功能恢复较好。 展开更多
关键词 下肢复杂性损伤 股前外侧皮瓣 旋髂浅动脉皮瓣 flow-through皮瓣 创面修复
原文传递
股前外侧Flow-through皮瓣在严重肢体损伤患者保肢治疗中的应用
3
作者 李刚 范新宇 +3 位作者 徐永清 苏踊跃 刘兴强 喻伟 《创伤外科杂志》 2025年第9期666-670,共5页
目的探讨股前外侧Flow-through皮瓣在严重肢体损伤(SLI)患者保肢治疗中的临床应用价值。方法回顾性分析2022年6月—2024年12月中国人民解放军联勤保障部队第九二〇医院骨科采用股前外侧Flow-through皮瓣保肢治疗的12例(SLI)患者,男性9例... 目的探讨股前外侧Flow-through皮瓣在严重肢体损伤(SLI)患者保肢治疗中的临床应用价值。方法回顾性分析2022年6月—2024年12月中国人民解放军联勤保障部队第九二〇医院骨科采用股前外侧Flow-through皮瓣保肢治疗的12例(SLI)患者,男性9例,女性3例;年龄6~57岁,平均29.3岁;上肢4例,下肢8例;爆炸伤1例,农业机械碾切伤3例,重物砸伤2例,道路交通伤6例;软组织缺损面积10 cm×7 cm~20 cm×6 cm,血管缺损长度5~10 cm,骨缺损长度2~9 cm。其中10例一期完成修复,2例二期手术;皮瓣切取面积11 cm×8 cm~21 cm×7 cm。术后患者均进行门诊随访,随访内容包括皮瓣和肢体的外观及质地、骨折愈合情况及患肢功能。结果术后随访12~24个月,平均15.1个月,12例患者皮瓣及肢体均成活,其中2例术后1 d出现血管危象,经探查处理后好转;3例皮瓣远端小面积坏死经清创植皮后愈合;1例在植骨内固定术后2个月因过早下地负重导致内固定断裂,再次手术后骨折愈合。末次随访下肢功能优良率87.5%(Johner-Wrush评分),上肢功能优良率75.0%(Berton评分)。结论股前外侧Flow-through皮瓣可同时修复SLI者的软组织与血管缺损,具有血供可靠、成活率高、功能恢复良好的特点,是保肢治疗的有效方法。 展开更多
关键词 严重肢体损伤 穿支皮瓣 血管移植 保肢
暂未订购
Upper Eyelid Myocutaneous Flap and External Tarsorrhaphy, Two Combined Minimally Invasive Techniques in the Functional and Cosmetic Correction of Cicatricial Ectropion of the Lower Eyelid: An Experience of Two Clinical Cases Follow in Short Term
4
作者 Julls Celestin Apouakone Elie Fazaa +3 位作者 Loubna El Hajj Greta Lipa Sophie Cassier Eric Dunet 《Modern Plastic Surgery》 2025年第1期21-31,共11页
Cicatricial ectropion of the eyelid is an eversion of its edge, which has moved away from the globe. It is frequently the result of cicatricial retraction after trauma. The main risk is the occurrence of a corneal ulc... Cicatricial ectropion of the eyelid is an eversion of its edge, which has moved away from the globe. It is frequently the result of cicatricial retraction after trauma. The main risk is the occurrence of a corneal ulcer or chronic conjunctivitis. Their treatment is often difficult, especially when the ectropion is old and significant. There are several classic techniques for correcting cicatricial ectropions, but the technique of the myocutaneous flap combined with external tarsorrhaphy without damage to the canthal ligament is minimally invasive, not very widespread, yet responds very well to the rules of plastic surgery. We report two cases of post-traumatic cicatricial ectropions of the left lower eyelid, respectively in a 33-year-old and an 87-year-old, treated using this technique. The surgical procedure was performed in two stages, after evaluation of the skin of the flap to be harvested: harvesting of the flap and closure plasty including external tarsorrhaphy. Patient follow-up did not note any complications. This combined technique offers a minimally invasive alternative for the often-delicate treatment of ectropions. 展开更多
关键词 ECTROPION SCAR flap EYELID Tarsorrhaphy
暂未订购
Modeling of Flapping Wing Aerial Vehicle Using Hybrid Phase-functioned Neural Network Based on Flight Data
5
作者 Zhihao Zhao Zhiling Jiang +1 位作者 Chenyang Zhang Guanghua Song 《Journal of Bionic Engineering》 2025年第3期1126-1142,共17页
Modeling the dynamics of flapping wing aerial vehicle is challenging due to the complexity of aerodynamic effects and mechanical structures.The aim of this work is to develop an accurate dynamics model of flapping win... Modeling the dynamics of flapping wing aerial vehicle is challenging due to the complexity of aerodynamic effects and mechanical structures.The aim of this work is to develop an accurate dynamics model of flapping wing aerial vehicle based on real flight data.We propose a modeling framework that combines rigid body dynamics with a neural network to predict aerodynamic effects.By incorporating the concept of flapping phase,we significantly enhance the network’s ability to analyze transient aerodynamic behavior.We design and utilize a phase-functioned neural network structure for aerodynamic predictions and train the network using real flight data.Evaluation results show that the network can predict aerodynamic effects and demonstrate clear physical significance.We verify that the framework can be used for dynamic propagation and is expected to be utilized for building simulators for flapping wing aerial vehicles. 展开更多
关键词 flapping wing aerial vehicle flapping phase Modeling Neural networks
在线阅读 下载PDF
Deep inferior epigastric perforator and transverse rectus abdominis musculocutaneous flap breast reconstruction: A comparison of breast mobility outcomes
6
作者 Cheng Huang Xia Fang +4 位作者 Nan Li Dawei Li Qi Bao Chenggang Yi Xueqing Hu 《Chinese Journal of Plastic and Reconstructive Surgery》 2025年第2期89-92,共4页
Current breast reconstruction evaluations mostly focus on static cosmetic analysis as a measure of the clinical outcomes.Moreover,it is essential to consider the dynamic changes in the reconstructed breast alongside a... Current breast reconstruction evaluations mostly focus on static cosmetic analysis as a measure of the clinical outcomes.Moreover,it is essential to consider the dynamic changes in the reconstructed breast alongside assessments of aesthetic symmetry,functional restoration,complication rates,and long-term stability of the reconstruction.This study aimed to assess the mobility of the reconstructed breast following various breast reconstruction techniques,specifically by comparing deep inferior epigastric perforator(DIEP) flaps and pedicled transverse rectus abdominis musculocutaneous(TRAM) flaps.We conducted a longitudinal case study to investigate the changes in breast movement resulting from different surgical interventions.The comparison showed that DIEP flap reconstruction was more likely to achieve superior breast mobility outcomes than TRAM flap reconstruction.For a better breast aesthetic outcome,it is fundamental to improve the awareness of the dynamic evaluation of the reconstructed breast at the surgical strategy level. 展开更多
关键词 Deep inferior epigastric perforator flap Transverse rectus abdominis musculocutaneous flap Breast mobility Breast reconstruction outcome
暂未订购
Anatomical CT study of lumbar artery perforator flap in women
7
作者 Olesya Startseva Igor Reshetov +4 位作者 Jaume Masia Alexandra Frolova Elena Mershina Evgeniya Zhigailova Mark Gabriyanchik 《Chinese Journal of Plastic and Reconstructive Surgery》 2025年第2期78-82,共5页
Background: The lumbar artery perforator(LAP) flap is an important autologous option in breast reconstruction.As the lumbar perforator flap is relatively new in this field,several questions remain regarding preoperati... Background: The lumbar artery perforator(LAP) flap is an important autologous option in breast reconstruction.As the lumbar perforator flap is relatively new in this field,several questions remain regarding preoperative preparation,especially concerning computed tomography(CT) and magnetic resonance imaging of the donor site.The objective of this study was to aid the surgical approach to the LAP flap in female patients by precisely determining the characteristics of the lumbar perforators.Methods: We retrospectively reviewed the computed tomographic angiography images of 20 patients who underwent evaluation of the perforator positions from the four lumbar arteries.Four characteristics were studied:length,diameter,path of the lumbar pedicle,and thickness of the tissues available for transfer.Results: We analyzed 20 CT images,identifying 149 perforating vessels of the lumbar artery.The most suitable perforator for flap harvesting was the L4 perforator,which exhibited a larger diameter,a greater number of perforasomes,and a higher percentage of the cutaneous-septal tract.Conclusion: The LAP flap is a viable option for breast reconstruction and as a free flap in women.The L4 perforator artery is the most suitable for harvesting,owing to its superior perfusion capacity,diameter,and course;however,an interposition graft may be required to lengthen the vascular pedicle. 展开更多
关键词 LAP-flap Breast reconstruction CT-Study Perforator flap
暂未订购
Post-operative outcomes in rectourethral fistula repair using gracilis interposition flap
8
作者 Gabrielle Yankelevich Jessica Swaim +5 位作者 Ian Coate Margaret Stroud William Stallings Virgilio George M.Lance Tavana Harry Clarke 《The Canadian Journal of Urology》 2025年第1期37-42,共6页
Objectives:To assess outcomes of rectourethral fistula repair utilizing a gracilis flap in a largely radiated cohort.Patients and Methods:We performed a retrospective review of all gracilis interposition flap reconstr... Objectives:To assess outcomes of rectourethral fistula repair utilizing a gracilis flap in a largely radiated cohort.Patients and Methods:We performed a retrospective review of all gracilis interposition flap reconstruction surgeries performed for RUF at a university hospital in South Carolina between January 2010 and June 2023.All repairs utilized a multidisciplinary approach with urology,colorectal,and plastic surgery teams.Postoperatively,patients were maximally drained with foley catheter and suprapubic tube(SPT).Initial voiding cystourethrogram(VCUG)was performed at 4 weeks post-repair.If there was a persistent leak,catheter drainage was maintained for 4 additional weeks and VCUG was repeated.Success was defined as absence of leak on VCUG within 3 months after surgery.Results:22 patients met inclusion criteria.68%of patients had history of external beam radiation therapy(EBRT),13.6%had brachytherapy,and 40.9%had cryotherapy.Initial post-operative VCUG was negative in 10 patients(45.5%).Of the 12 patients with a persistent fistula,5(42%)had no evidence of fistula on subsequent VCUG after 4 weeks.Overall,68%of patients were successfully treated with gracilis interposition flap.There was a significant difference of repair success based on EBRT status(p<0.05).Conclusions:We report a success rate of 68%for gracilis flap repair of RUF.Our cohort had a higher rate of prior radiation therapy compared to other studies.A clinically significant portion of patients with an initial positive VCUG will seal their fistula with prolonged catheter drainage.Gracilis interposition flap is a reasonable surgical treatment for RUF. 展开更多
关键词 rectourethral fistula fistula repair gracilis flap radiation reconstruction
暂未订购
Interference mechanism of trailing edge flap shedding vortices with rotor wake and aerodynamic characteristics
9
作者 Yang LIU Yongjie SHI +2 位作者 Aqib AZIZ Guohua XU Haifeng GAO 《Chinese Journal of Aeronautics》 2025年第1期325-339,共15页
A robust Reynolds-Averaged Navier-Stokes(RANS)based solver is established to predict the complex unsteady aerodynamic characteristics of the Active Flap Control(AFC)rotor.The complex motion with multiple degrees of fr... A robust Reynolds-Averaged Navier-Stokes(RANS)based solver is established to predict the complex unsteady aerodynamic characteristics of the Active Flap Control(AFC)rotor.The complex motion with multiple degrees of freedom of the Trailing Edge Flap(TEF)is analyzed by employing an inverse nested overset grid method.Simulation of non-rotational and rotational modes of blade motion are carried out to investigate the formation and development of TEF shedding vortex with high-frequency deflection of TEF.Moreover,the mechanism of TEF deflection interference with blade tip vortex and overall rotor aerodynamics is also explored.In nonrotational mode,two bundles of vortices form at the gap ends of TEF and the main blade and merge into a single TEF vortex.Dynamic deflection of the TEF significantly interferes with the blade tip vortex.The position of the blade tip vortex consistently changes,and its frequency is directly related to the frequency of TEF deflection.In rotational mode,the tip vortex forms a helical structure.The end vortices at the gap sides co-swirl and subsequently merge into the concentrated beam of tip vortices,causing fluctuations in the vorticity and axial position of the tip vortex under the rotor.This research concludes with the investigation on suppression of Blade Vortex Interaction(BVI),showing an increase in miss distance and reduction in the vorticity of tip vortex through TEF phase control at a particular control frequency.Through this mechanism,a designed TEF deflection law increases the miss distance by 34.7%and reduces vorticity by 11.9%at the target position,demonstrating the effectiveness of AFC in mitigating BVI. 展开更多
关键词 CFD ROTOR Aerodynamic Trailing edge flap Vortex shedding BVI
原文传递
游离移植小腿内侧Flow-through皮瓣修复前臂毁损伤1例
10
作者 孙克理 谢书强 +3 位作者 董其强 尹大海 王海康 方旭 《创伤外科杂志》 2025年第1期76-77,80,共3页
严重肢体开放性损伤常造成组织毁损、骨折粉碎、主干血管、神经长段损伤,具有感染风险高、修复难度大、肢体致残率高的特点,严重情况下患者可能在短时间内大量失血,出现休克甚至死亡^([1]),临床治疗比较棘手。2023年2月,郑州仁济医院显... 严重肢体开放性损伤常造成组织毁损、骨折粉碎、主干血管、神经长段损伤,具有感染风险高、修复难度大、肢体致残率高的特点,严重情况下患者可能在短时间内大量失血,出现休克甚至死亡^([1]),临床治疗比较棘手。2023年2月,郑州仁济医院显微外科应用显微外科技术,通过游离移植小腿内侧胫后动脉穿支Flow-through皮瓣修复前臂毁损伤1例,术后治疗效果满意,外观较好。 展开更多
关键词 flow-through皮瓣 胫后动脉穿支皮瓣 修复
暂未订购
Nonlinear flow control mechanism of two flexible flaps with fluid-structure interaction
11
作者 Jiakun Han Chao Dong +1 位作者 Jian Zhang Gang Chen 《Acta Mechanica Sinica》 2025年第2期116-131,共16页
The flow control at low Reynolds numbers is one of the most promising technologies in the field of aerodynamics,and it is also an important source of the innovation for novel aircraft.In this study,a new way of nonlin... The flow control at low Reynolds numbers is one of the most promising technologies in the field of aerodynamics,and it is also an important source of the innovation for novel aircraft.In this study,a new way of nonlinear flow control by interaction between two flexible flaps is proposed,and their flow control mechanism is studied employing the self-constructed immersed boundary-lattice Boltzmann-finite element method(IB-LB-FEM).The effects of the difference in material properties and flap length between the two flexible flaps on the nonlinear flow control of the airfoil are discussed.It is suggested that the relationship between the deformation of the two flexible flaps and the evolution of the vortex under the fluid-structure interaction(FSI).It is shown that the upstream flexible flap plays a key role in the flow control of the two flexible flaps.The FSI effect of the upstream flexible flap will change the unsteady flow behind it and affect the deformation of the downstream flexible flap.Two flexible flaps with different material properties and different lengths will change their own FSI characteristics by the induced vortex,effectively suppressing the flow separation on the airfoil’s upper surface.The interaction of two flexible flaps plays an extremely important role in improving the autonomy and adjustability of flow control.The numerical results will provide a theoretical basis and technical guidance for the development and application of a new flap passive control technology. 展开更多
关键词 Nonlinear flow control Flexible flap Fluid-structure interaction Flow separation IB-LB-FEM
原文传递
Novel Approach to Osteoradionecrosis of the Temporal Bone:Vascularized Obliteration with Gracilis Muscular Free Flap
12
作者 Saro-Buendía Miguel Andresen-Lorca Belén +4 位作者 Pérez-García Alberto Llópez Carratala Nacho Carreres Polo Joan Armengot Carceller Miguel Perolada Valmaña Jose María 《Journal of Otology》 2025年第2期123-126,共4页
Osteoradionecrosis of the temporal bone(ORN-TB)is usually controlled with conservative measures.However,a temporal bone resection may be required in unresponsive cases.The reconstruction of the resulting defects may b... Osteoradionecrosis of the temporal bone(ORN-TB)is usually controlled with conservative measures.However,a temporal bone resection may be required in unresponsive cases.The reconstruction of the resulting defects may be challenging because of the radiation damage to regional tissues.As a result,distant free flaps may be an optimal choice.For instance,the gracilis muscular free flap(GMFF)has consistent vascular anatomy and can be used to reconstruct small defects.We report three cases of uncontrolled ORN-TB requiring an extensive temporal bone resection followed by vascularized obliteration with a GMFF.The patients reported complete control of the main otologic symptoms(otorrhea,otalgia,and aural fullness)and optimal functional and aesthetic outcomes.Finally,the patients reported significant improvement in quality of life despite early postoperative complications.To our knowledge,the GMFF had not been used to obliterate temporal bone defects in patients with ORN-TB. 展开更多
关键词 OSTEORADIONECROSIS Osteoradionecrosis of the temporal bone Temporal bone resection Gracilis muscular free flap Head and neck radiotherapy Head and neck reconstructive surgery Vascularized flap obliteration
暂未订购
Surgical outcome of a transposed lateral pendular flap for the reconstruction of medial and central lower lid defects
13
作者 Yomna Amr Alahmadawy Radwa Taher Elzanaty Shaimaa Abdelsalam Arfeen 《International Journal of Ophthalmology(English edition)》 2025年第8期1450-1455,共6页
AIM:To evaluate the outcome and the degree of patient satisfaction with the reconstruction of full-thickness medial and central lower lid defects using a pendular flap of the remaining lateral part of the lower lid.ME... AIM:To evaluate the outcome and the degree of patient satisfaction with the reconstruction of full-thickness medial and central lower lid defects using a pendular flap of the remaining lateral part of the lower lid.METHODS:Totally 20 patients with full thickness medial or central lower lid defects that could not be repaired by direct closure with or without cantholysis.A sliding full-thickness composite flap was created from the lateral part of the remaining lid to cover the defect.The posterior lamella of the induced lateral defect was repaired by either a periosteal flap alone or in combination with a free tarsal graft.Postoperative cosmetic and functional outcomes were evaluated.RESULTS:The mean age of the patients was 46.3±18.1y(20-70y).The defects ranged from 30%-80%of the lid width and resulted from the excision of lid tumors in 11 patients(55%)and from trauma in 9(45%)patients.Postoperative complications included one case of lateral graft ectropion,2 cases of lid retraction and 3 cases of marginal graft necrosis.Most of the patients had an acceptable final cosmetic outcome.CONCLUSION:Reconstruction of moderate-sized defects in the medial/central lower lid via a sliding flap yielded acceptable cosmetic and functional outcomes with high patient satisfaction.Large defects≥50%of the horizontal length are at greater risk of complications.Reconstruction of medial defects by this technique was associated with a greater incidence of complications. 展开更多
关键词 lower lid defects lateral pendular flap RECONSTRUCTION
原文传递
Technical refinement of the reverse homodigital dorsoradial flap:A preliminary case report on flap optimization for radial thumb defects
14
作者 Nhat Dang Huy Nguyen Huy Anh Pham +1 位作者 Phu Man Truong Ho Phi Duong Nguyen 《Chinese Journal of Plastic and Reconstructive Surgery》 2025年第3期191-196,共6页
Soft tissue reconstruction of the radial thumb tip remains surgically challenging,particularly when standard options such as kite or Brünelli flaps are less suitable due to anatomical constraints.This technical n... Soft tissue reconstruction of the radial thumb tip remains surgically challenging,particularly when standard options such as kite or Brünelli flaps are less suitable due to anatomical constraints.This technical note presents the case of a 37-year-old male with a radial-sided distal thumb defect reconstructed using a reverse homodigital dorsoradial flap.Two key refinements were applied:preservation of approximately 5 mm of subcutaneous tissue to support venous outflow and a 3-5 mm proximal safety margin at the pivot point based on Doppler assessment to reduce pedicle tension during 180◦rotation.The flap was inset without tunneling and healed without complications.Functional recovery was confirmed by progressive improvements in the disabilities of the arm,shoulder and hand score(from 25 at 1 month to 4.2 at 1 year),normal range of motion,and two-point discrimination(from 5 mm to 4 mm).This case highlights the practical advantages of flap design refinement for radial thumb reconstruction and supports its reproducibility in similar clinical scenarios.However,as this is a single case report,further validation with studies involving multiple cases is necessary to confirm the reliability and broad applicability of these refinements. 展开更多
关键词 THUMB Reconstructive surgery Soft tissue injury Surgical flap Hand injury
暂未订购
Erratum to:Novel Approach to Osteoradionecrosis of the Temporal Bone:Vascularized Obliteration with Gracilis Muscular Free Flap
15
作者 Miguel Saro-Buendía Belén Andresen-Lorca +4 位作者 Alberto Pérez-García Nacho Llópez Carratala Joan Carreres Polo Miguel Armengot Carceller Jose María Perolada Valmaña 《Journal of Otology》 2025年第3期210-210,共1页
The online version of the original article can be found at:https://www.sciopen.com/article/10.26599/JOTO.2025.9540018 Erratum to Journal of Otology,2025,20(2):123-126.https://doi.org/10.26599/JOTO.2025.9540018 The sur... The online version of the original article can be found at:https://www.sciopen.com/article/10.26599/JOTO.2025.9540018 Erratum to Journal of Otology,2025,20(2):123-126.https://doi.org/10.26599/JOTO.2025.9540018 The surnames and given names of these authors are reversed:Saro-Buendía Miguel,Andresen-Lorca Belén,Pérez-García Alberto,Llópez Carratala Nacho,Carreres Polo Joan,Armengot Carceller Miguel,Perolada Valmaña Jose María.It should be Miguel Saro-Buendía,Belén Andresen-Lorca,Alberto Pérez-García,Nacho Llópez Carratala,Joan Carreres Polo,Miguel Armengot Carceller,Jose María Perolada Valmaña. 展开更多
关键词 OSTEORADIONECROSIS Osteoradionecrosis of the temporal bone Temporal bone resection Gracilis muscular free flap Head and neck radiotherapy Head and neck reconstructive surgery Vascularized flap obliteration
暂未订购
2D Hydrodynamic Performance of a Bottom-Hinged Flap Breakwater:Pitching Motion Response Under Random Waves and Comparison with Regular Waves
16
作者 YIN Zegao LI Feifan +1 位作者 ZHANG Chao LI Guoqing 《Journal of Ocean University of China》 2025年第5期1206-1222,共17页
To propel the application of a bottom-hinged flap breakwater in real sea conditions,a two-dimensional computational fluid dynamics numerical model was conducted to investigate the pitching motion response and wave att... To propel the application of a bottom-hinged flap breakwater in real sea conditions,a two-dimensional computational fluid dynamics numerical model was conducted to investigate the pitching motion response and wave attenuation in random waves.First,the flow velocity distribution characteristic of the pitching flap at typical times was summarized.Then,the effects of random wave and flap parameters on the flap’s significant pitching angle amplitude θ_(s) and hydrodynamic coefficients were investigated.The results reveal that θ_(s) and wave reflection coefficient K_(r) values increase with increasing significant wave height Hs,random wave steepnessλs,and flap relative height.As Hs andλs increase,the wave transmission coefficient K_(t) increases while the wave dissipation coefficient K_(d) decreases.Additionally,K_(t) decreases with increasing flap relative height.With increasing equivalent damping coefficient ratio,θ_(s) and K_(t) decrease,while K_(r) and K_(d) increase.The relationships betweenλs and flap relative height on the one hand andθ_(s),K_(r),K_(t),and K_(d) in random waves on the other hand are compared to those in regular waves.Based on the equal incident wave energy and the equal incident wave energy flux,the pitching flap performs better in the wave attenuation capability under random waves than in regular waves.Finally,the dimensionless parameters with respect to random wave and flap were used to derive the K_(r) and K_(t) for-mulae,which were validated with the related data. 展开更多
关键词 pitching flap pitching angle amplitude hydrodynamic coefficients random waves regular waves
在线阅读 下载PDF
TcPO_(2)and TcPCO_(2)monitoring for free flap perfusion assessment
17
作者 Fangfang Liu Nannan Han +5 位作者 Huimin Yuan Lei Wang Jinxiu Dong Yanfen Ding Min Ruan Youguo Ying 《Chinese Journal of Plastic and Reconstructive Surgery》 2025年第3期133-139,共7页
Background:Free flap transplantation has emerged as a prevalent technique in reconstructive surgery for patients with oral cancer.Postoperative monitoring of flap perfusion is critical for flap survival,necessitating ... Background:Free flap transplantation has emerged as a prevalent technique in reconstructive surgery for patients with oral cancer.Postoperative monitoring of flap perfusion is critical for flap survival,necessitating early detection and timely intervention.Developing a monitoring approach that is highly sensitive,specific,noninvasive,continuous,and cost-effective is crucial for accurately assessing flap perfusion and informing clinical decisions.Methods:From April 2024 to December 2024,20 patients with oral tumors requiring flap transplantation were enrolled at the Ninth People’s Hospital affiliated to Shanghai Jiao Tong University School of Medicine.Continuous monitoring of various free flaps was performed utilizing a transcutaneous blood gas analyzer,both before and after surgery.This approach allowed for real-time measurement of transcutaneous partial pressure of oxygen(TcPO_(2))and transcutaneous partial pressure of carbon dioxide(TcPCO_(2)),facilitating the evaluation of perfusion dynamics across various free flap types.Results:After free flap transplantation,a reduction in blood supply resulted in a rapid decline in TcPO_(2)(to below 10 mmHg),accompanied by a gradual increase in TcPCO_(2),peaking at 135 mmHg.Following vascular anastomosis and blood flow restoration,TcPO_(2)and TcPCO_(2)exhibited opposite trends.Statistical analysis revealed no significant differences in TcPO_(2)and TcPCO_(2)measurements among the various flap types(P<0.05),indicating a consistent pattern of change across all flaps.Conclusion:The transcutaneous blood gas analyzer proves to be a reliable method for monitoring free flap perfusion.Dynamic changes in TcPO_(2)and TcPCO_(2)effectively reflect blood supply status,enabling early detection of vascular compromise and potentially enhancing flap preservation outcomes. 展开更多
关键词 TcPO_(2) TcPCO_(2) Free flaps Oral tumors
暂未订购
Combined anterior corneal elastic sublaminectomy,conjunctival flap,and prosthetic eyepiece for ocular atrophy following foldable capsular vitreous body implantation in severe trauma
18
作者 Ling-Dan Wu Pei-Jie Huang +7 位作者 Zhou Peng Huang Zhang Sheng-Xiang Zhang An-An Wang Meng-Tian Qiu Li-Chang Ma Ye-Feng Zhu Qi-Hua Xu 《International Journal of Ophthalmology(English edition)》 2025年第11期2149-2154,共6页
AIM:To investigate the outcome of combined anterior corneal elastic sublaminectomy,conjunctival flap,and prosthetic eyepiece for ocular atrophy following foldable capsular vitreous body(FCVB)implantation in severe tra... AIM:To investigate the outcome of combined anterior corneal elastic sublaminectomy,conjunctival flap,and prosthetic eyepiece for ocular atrophy following foldable capsular vitreous body(FCVB)implantation in severe trauma.METHODS:This study conducted a retrospective analysis of 38 patients who underwent conjunctival flap coverage followed by prosthetic eyepiece fitting after developing ocular atrophy secondary to FCVB surgery.Anterior corneal elastic sublaminectomy combined with conjunctival coverage was performed on the FCVBimplanted atrophic eyes.Prosthetic lenses were fitted after complete healing of the stroma and conjunctiva and suture removal.Corneal irritation,eyeball protrusion,axial length,lid height,cosmetic satisfaction,and pain numerical rating scale scores were observed before the conjunctival flap covering and after the prosthetic eyepiece surgery.RESULTS:The ocular protrusion was 11 mm preoperatively and 14 mm postoperatively,with the difference being statistically significant(Z=-5.459,P<0.001).The ocular axis length was 20.82±0.94 mm in the experimental group and 23.57±0.33 mm in the control group,showing a statistically significant difference(t=-20.207,P<0.05).The lid height was 6 mm in the experimental group and 9 mm in the control group,a difference that was statistically significant(Z=-5.326,P<0.001).The appearance satisfaction score was 1 in the experimental group and 4 in the control group,with this difference being statistically significant(Z=-5.447,P=0.001).Regarding the pain numerical rating scale score,the ranges were 0-2 in the experimental group and 0 in the control group.No discomfort was reported after wearing the prosthetic eyepiece,and the difference was not statistically significant(Z=-1.100,P>0.05).There was no statistically significant difference between pre-and post-treatment satisfaction.CONCLUSION:A conjunctival flap covering and a prosthetic eyepiece after FCVB postoperative atrophy can reduce the number of surgeries,alleviate patients’economic burdens,satisfy patients’psychological eyeball retention requirements,and provide better cosmetic efficacies for patients desiring eyeball retention or silicone-oil dependence. 展开更多
关键词 open ocular trauma conjunctival flap prosthetic eyepiece foldable capsular vitreous body
原文传递
Flap endonuclease-1 promotes pancreatic cancer progression via AKT/mTOR signaling pathway
19
作者 Yu Xia Na Guo +2 位作者 Cheng-Lou Zhu Jie-Yun Gao Ming-Xu Da 《World Journal of Gastrointestinal Oncology》 2025年第7期244-261,共18页
BACKGROUND Pancreatic cancer(PC)remains one of the most lethal malignancies.While flap endonuclease-1(FEN1)has been implicated in various cancers,its role in PC remains unclear.AIM To investigate the biological functi... BACKGROUND Pancreatic cancer(PC)remains one of the most lethal malignancies.While flap endonuclease-1(FEN1)has been implicated in various cancers,its role in PC remains unclear.AIM To investigate the biological functions and mechanisms of FEN1 in PC progression.METHODS FEN1 expression and its prognostic significance were analyzed using Gene Expression Omnibus,The Cancer Genome Atlas,and Genotype-Tissue Expression databases.FEN1 was knocked down or overexpressed in PC cell lines using lentiviral vectors.Cell proliferation,migration,and invasion were assessed in vitro,while tumorigenicity was evaluated in nude mouse xenografts.Molecular mechanisms were explored through RNA-sequencing and validated by western blot analysis.RESULTS FEN1 was significantly upregulated in PC tissues and correlated with poor prognosis.FEN1 promoted PC cell proliferation,migration,and invasion in vitro,as well as xenograft tumor growth in vivo.Mechanistically,FEN1 regulated epithelial-mesenchymal transition through the AKT/mTOR signaling pathway.CONCLUSION FEN1 functions as an oncogenic driver in PC progression via the AKT/mTOR signaling pathway,suggesting its potential as a therapeutic target. 展开更多
关键词 flap endonuclease-1 Pancreatic cancer AKT/mTOR signaling pathway Proliferation Migration INVASION
暂未订购
Efficacy of free-flap-transfer and plate-fixation for Gustilo ⅢB fractures in type Ⅱ diabetic patients:A retrospective study
20
作者 Qi Bao Sun-Wen Pan +5 位作者 Xiao-Kang Gong Bo Wang Zhi-Nan Wei Yong-Qing Xu Yue-Liang Zhu Zhen Shi 《World Journal of Clinical Cases》 2025年第28期30-42,共13页
BACKGROUND Managing Gustilo type ⅢB fractures in patients with type 2 diabetes is challenging due to delayed healing and elevated complication risks.This retro-spective study highlights the successful use of free-fla... BACKGROUND Managing Gustilo type ⅢB fractures in patients with type 2 diabetes is challenging due to delayed healing and elevated complication risks.This retro-spective study highlights the successful use of free-flap transfer combined with plate fixation,contributing insights into effective management strategies for these complex cases.AIM To evaluate free-flap transfer with plate fixation for managing Gustilo ⅢB fractures in diabetic patients,focusing on outcomes.METHODS A retrospective analysis of six cases was conducted with a minimum follow-up period of three years.Patients underwent free-flap transfer and plate fixation for fracture management.Outcomes assessed included bone union,flap viability,and complications requiring intervention or plate removal.The follow-up period ranged from three to four years.Persistent infections beneath the flap developed in two patients,necessitating daily wound care.RESULTS Bone healing occurred within 17 to 34 months,with plate removal required in three patients after fracture consolidation.Traumatic osteomyelitis was observed in at least one patient.Despite challenges such as sinus formation and variations in flap pedicle anatomy,successful bone union and flap viability were achieved in all cases.Freeflap transfer combined with plate fixation shows promise for treating Gustilo type ⅢB fractures in patients with diabetes.While infection and the need for plate removal surgeries were observed,consistent success in bone healing and flap viability highlights the potential of this approach.CONCLUSION Free-flap transfer with plate fixation effectively manages Gustilo ⅢB fractures in diabetics,achieving bone/flap healing despite infection risks.Careful patient selection and further validation are critical. 展开更多
关键词 Free flap GustiloⅢB fractures Plate fixation TypeⅡdiabetes Soft tissue defect
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部