Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large brid...Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large bridges in the world. These two types of railway floor systems of the two bridges have never been used in China before. The problem how to conform the deformations and stress levels of the railway floor system of WTC Bridge was studied. After finite element analysis and comparison,the plan of arranging one expansion stringer every two panels in railway floor system were proposed and good effect was obtained. Because of the application of three trusses,the allocation of the loads acted on the deck in three trusses is different and varies in different places of NDC Bridge. This problem was studied by model experiment and 3D finite element analysis. The results of 3D FEM analysis coincide with the model test results. The allocation rule of the loads acting on the deck in three trusses was presented. Because of the application of monolithic decks,the stiffness and structural integrity of NDC Bridge are high.展开更多
In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the ...In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the off-peak period and use them in the peak period. An experimental setup was developed to study the heat transfer characteristics of the new system under both cooling and heating modes. The experimental results show that the double-layer radiant floor system with PCM can meet both the cold and thermal requirements of users. Moreover, with the same duration of the thermal energy storage process, the increase of water temperature supplied to the system can improve the heat transfer characteristics of the system but lead to the discomfort of users. On the other hand, if the air temperature at the end of the thermal energy storage process is the same under different conditions, the increase of supplied water temperature will decrease the thermal energy storage time and ensure the comfort of users.展开更多
The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize ...The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize the RC ribbed floor system,including floor and underground garage roof.By considering the effects of reinforcement,the principle of virtual work is applied to calculate the deflections of components.Construction cost is taken as the objective function and the constraint conditions are required to satisfy.Accordingly,the optimal layout,the optimal sections of the beams and slabs and the corresponding reinforcements are obtained for different column grids.In this investigation,the RC ribbed floor system is optimized according to the Chinese standard,whose column grids are 8.4 m and 8.4 m.The performance of the ES-PSO algorithm is good enough,which can be applied to practical engineering.The paper can also provide a basis for subsequent optimization design of monolithic structures.展开更多
Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cos...Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cost and input energy comparisons of RC office buildings of different floor systems.Conventional solid,ribbed,flat plate and flat slab systems are considered in the study.Building models in three-dimensional using extended threedimensional analysis of building systems(ETABS)and in two-dimensional using slab analysis by the finite element(SAFE)are developed for analysis purposes.Analysis and design using both software packages and manual calculations are employed to obtain the optimum sections and reinforcements to fit cities of low seismic intensities for all the considered building systems.Two ground motion records of low peak ground acceleration(PGA)levels are used to excite the models to measure the input energies.Uniformat cost estimating system is adopted to categorize building components according to 12 divisions.Also,Microsoft(MS)Project is utilized to identify the construction cost and duration of each building system.The study shows that floor system significantly causes changes in the input energy to structures.In addition,the slight increase in the PGA increases the amount of input energy particularly flat plate system.Estimated cost of the flat plate system that the flat slab system is of higher value as compared to ribbed and conventional slab systems.The use of drop panels increases this value as well.Moreover,the estimated cost of the ribbed slab system exceeds that of conventional system.展开更多
The Noise,Vibration,and Harshness(NVH)experience during driving is significantly influenced by the sound insulation performance of the car floor acoustic package.As such,accurate and efficient predictions of its sound...The Noise,Vibration,and Harshness(NVH)experience during driving is significantly influenced by the sound insulation performance of the car floor acoustic package.As such,accurate and efficient predictions of its sound insulation performance are crucial for optimizing related noise reduction designs.However,the complex acoustic transmission mechanisms and difficulties in characterizing the sound absorption and insulation properties of the floor acoustic package pose significant challenges to traditional Computer-Aided Engineering(CAE)methods,leading to low modeling efficiency and prediction accuracy.To address these limitations,a hierarchical multiobjective decomposition system for predicting the sound insulation performance of the floor acoustic package has been developed based on an analysis of the noise transmission path.This approach involves introducing a 1D-Convolutional Neural Network(1D-CNN)model for predicting the sound insulation performance of the floor acoustic package,thereby avoiding the limitations of conventional CAE approaches that rely solely on“data-driven”methods.The proposed method was applied and tested using specific vehicle models,and the results demonstrated the effectiveness and superiority of the proposed approach relative to those obtained using 2D-CNN and Support Vector Regression(SVR)models.展开更多
At a critical juncture of global industrial transformation and economic recovery,the 2026 China Expo Forum for International Cooperation(CEFCO)recently concluded in Wuhan.Dubbed the“Davos of the exhibition industry”...At a critical juncture of global industrial transformation and economic recovery,the 2026 China Expo Forum for International Cooperation(CEFCO)recently concluded in Wuhan.Dubbed the“Davos of the exhibition industry”,the forum,attracted more than 600 exhibition professionals from over 20 countries and regions.展开更多
The shop floor dynamic scheduling system based on human-computer interaction is the use of computer-aided decision-making and human-computer interaction to solve the dynamic scheduling problem.A human-computer interac...The shop floor dynamic scheduling system based on human-computer interaction is the use of computer-aided decision-making and human-computer interaction to solve the dynamic scheduling problem.A human-computer interaction interface based on Gantt chart is designed,which can not only comprehensively and quantitatively represent the scheduling process and scheduling scheme,but also have friendly human-computer interaction performance.The data transmission and interaction architecture is constructed to realize the rapid response to shop floor disturbance events.A priority calculation algorithm integrating priority rules and dispatcher preference is proposed,which realizes the automatic calculation of priority for the dispatcher's reference and reduces theirburden.A man-machine interactive shop floor dynamic scheduling strategy is proposed.When solving the dynamic flexible job shop scheduling problem caused by machine tool breakdown and urgent order,the origin moments obtained by using this strategy are 0.4190 and 0.3703 respectively.As can be seen from the origin moment indicator,the dynamic shop floor scheduling system based on the human-computer interaction is efficient and reliable in solving dynamic scheduling problems,and related strategies of this system are also feasible and stable.展开更多
Water inrush hazards from the floor strata of longwall workingface are commonly encountered in North China coalfields,which essentially result from the evolution of permeability in the floor rock under complex mining-...Water inrush hazards from the floor strata of longwall workingface are commonly encountered in North China coalfields,which essentially result from the evolution of permeability in the floor rock under complex mining-induced stress conditions.Current research rarely addresses the evolution of rock permeability under such complex stress paths.Describing this evolution using only one stress parameter,such as effective stress,deviatoric stress,axial stress,or confining stress,is highly challenging.In this study,we developed a laboratory loading scheme that simulates mining-induced stress evolution.Hydro-mechanical experiments were conducted to investigate the evolution of rock permeability under mining stress.The mechanism on the change of stress-permeability relationships in mining-disturbed rock is revealed,supporting to the analysis of management strategies for floor water-inrush disasters.The results show that rock permeability evolves through four stages,including rapid decline,gradual fluctuation,sharp increase,and slow attenuation.1–2 permeability surges occurred during mining-stress loading,closely linked to the emergence and reversal of deviatoric stress in magnitude and direction.With the first permeability surge,the deviatoric stress within the mudstone reached approximately 1.7 MPa,whereas that of the sandstone was about 1 MPa.The second permeability surge in the mudstone corresponded to the secondary rotation of the principal stress direction.CT and ultrasonic tests suggested an increase in microcracks in both rocks during the first permeability surge.However,the deviatoric stress-permeability plot before and after mining indicated that the fracture of mudstone sample changed significantly,while that of the sandstone remained unchanged.The permeability surges observed at different stages are interpreted as resulting from shear-induced reopening of pre-existing fractures and the formation of new shear-failure fractures.A stress-permeability model jointly governed by effective mean stress and deviatoric stress was established.Furthermore,two strategies are proposed for the floor water-inrush disasters prevention,(i)timely backfilling to reduce deviatoric stress,(ii)grouting after the first permeability surge.This work provides insights into stress-seepage behavior in rocks under complex stress evolution and offers new perspectives for identifying potential water inrush pathways in the floor strata of coal seam during longwall mining.展开更多
This paper presents an experimental analysis of a solar-assisted powered underfloor heating system,designed primarily to boost energy efficiency and achieve reliable desired steady-state temperature in buildings.We th...This paper presents an experimental analysis of a solar-assisted powered underfloor heating system,designed primarily to boost energy efficiency and achieve reliable desired steady-state temperature in buildings.We thoroughly tested the system’s thermal and operational features by subjecting it to three distinct scenarios that mimicked diverse solar irradiance and environmental conditions.Our findings reveal a strong correlation between variations in solar input and overall system performance.The Solar Fraction(SF),our key energy efficiency metric,varied significantly across the cases,ranging from 63.1%up to 88.7%.This high reliance on renewables resulted in a substantial reduction in backup power;consequently,the auxiliary electric heater was only required to supply between 1.82 and 3.00 kWh over the test periods.The circulation pump operated on a precise control logic,engaging below 20℃ and disengaging at 21℃.Crucially,the experiments verified the system’s ability not only tomeet the air temperature setpoint but also to ensure the floor surface temperature stayed within required international comfort criteria.These robust results directly support the study’s main objective.For practical application,we advise increasing the total length of the embedded pipe network.This crucial adjustment would allow for a reduction in the required circulating water temperature,which in turn maximizes the utilization of low-grade solar heat and optimizes radiant heat delivery toward achieving the desired steady-state temperature.Ultimately,the study confirms that solar-assisted underfloor heating offers a technically viable,sustainable,and energy-efficient solution with the potential to significantly cut fossil fuel consumption.展开更多
Objectives:Postmenopausal women with stress urinary incontinence(SUI)exhibit low androgen expression.This study aimed to evaluate the efficacy and safety of vaginal androgen combined with pelvic floor muscle training(...Objectives:Postmenopausal women with stress urinary incontinence(SUI)exhibit low androgen expression.This study aimed to evaluate the efficacy and safety of vaginal androgen combined with pelvic floor muscle training(PFMT)in the treatment of SUI in postmenopausal women.Methods:Postmenopausal women with SUI were recruited from Hainan West Central Hospital between January 2024 and March 2025.Participants were randomly assigned in a double-blind manner to receive either vaginal androgen cream combined with PFMT(treatment group)or a visually identical placebo cream(without androgens)combined with PFMT(control group).The vaginal cream was applied to the vaginal wall at a dose of 0.5 g per application,twice weekly for a total of 10 applications,while PFMT was conducted for 8 weeks.The clinical efficacy and safety were compared between the two groups.Results:A total of 61 patients were finally enrolled,with 31 in the treatment group and 30 in the control group.At both 3-month and 6-month follow-ups,the treatment group demonstrated significantly lower values in daily pad usage(p<0.05),24-h pad test scores(p<0.05),and ICIQ-UI SF scores(p<0.05)compared to the control group.The improvement rate of urinary incontinence was significantly higher in the treatment group(p<0.05).Compared to baseline,the treatment group showed statistically significant reductions in all three outcome measures(all p<0.05).No severe adverse events were reported in either group during the treatment period.Conclusions:Androgen therapy combined with PFMT significantly improved the urinary incontinence remission rate in postmenopausal women with SUI,with no severe adverse effects observed.These findings suggest that androgen therapy may represent a novel therapeutic approach for SUI management in postmenopausal women.展开更多
Vaginal delivery is a fascinating physiological process,but also a high-risk process.Up to 85%–90%of vaginal deliveries lead to perineal trauma,with nearly 11%of severe perineal tearing.It is a common occurrence,espe...Vaginal delivery is a fascinating physiological process,but also a high-risk process.Up to 85%–90%of vaginal deliveries lead to perineal trauma,with nearly 11%of severe perineal tearing.It is a common occurrence,especially for first-time mothers.Computational childbirth plays an essential role in the prediction and prevention of these traumas,but fast personalization of the pelvis and floor muscles is challenging due to their anatomical complexity.This study introduces a novel shape-prediction-based personalization of the pelvis and floor muscles for perineal tearing management and childbirth simulation.300 subjects were selected from public Computed Tomography(CT)databases.The pelvic bone nmjmeshes were generated using a coarse-to-fine non-rigid mesh alignment procedure.The floor muscle meshes were personalized using the bone mesh deformation information.A feature-to-pelvic structure reconstruction pipeline was proposed,incorporating various strategies.Ten-fold cross-validation helped determine the optimal reconstruction strategy,regression method,and feature sizes.The mesh-to-mesh distance metric was employed for evaluating.The statistical shape relation-based strategy,coupled with multi-output ridge regression,was the optimal approach for pelvic structure reconstruction.With a feature set ranging from 3 to 38,the mean errors were 2.672 to 1.613 mm,and 3.237 to 1.415 mm in muscle attachment regions.The best-and worst-case predictions had errors of 1.227±0.959 mm and 2.900±2.309 mm,respectively.This study provides a novel approach to achieving fast personalized childbirth modeling and simulation for perineal tearing management.展开更多
The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on trad...The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on traditional hierarchical architecture and the top down approach and depend structurally on their specific configuration and job scheduling. Not only can they hardly satisfactorily adapt to these increasing changes and disturbances, but also make the redevelopment and maintenance of shop floor control system (SFCS) to need high cost and much time. And SFCS based on the heterarchical architecture don′t provide a predictable and high performance system, especially not in the heterogeneous environments, where the resources are scarce and the current decisions have serious repercussions on the future performances. For this reason, the heterarchical control is hardly applied in industry. Obviously, it is necessary to develop a new structural framework of reconfigurable SFCS to improve their agility, flexibility and maintainability. This paper presents a holonic framework of reconfigurable SFCS based on holonic manufacturing concepts. The framework is composed of resource holons, product holons and other staff holons. The model of each holon and the co operative mechanisms of holons are described. To verify the proposed approach experimentally, a prototype reconfigurable SFCS for a flexible manufacturing shop floor producing discrete parts is implemented.展开更多
To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and buil...To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.展开更多
The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous...The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous area of northeastern Greece in 2010–2015.The foliar litterfall for both species reached about 70%of the total litterfall,and was significantly higher from the other two fractions(woody and rest litterfall).The fluxes of masses and nutrients were compared between ecosystems for each fraction separately.Only one significant statistical difference was found,that of K in the woody litterfall.In addition,the stocks of masses and nutrients were calculated in the forest floors and mineral soils of the two ecosystems.Likewise,the stocks of nutrients in the forest floors and mineral soils were compared between ecosystems.In the L horizon of the forest floors,statistical differences,as a result of species effect,were found for the stocks of Ca and N.In the FH horizons,the masses and all the nutrient stocks differed significantly,as the beech plot had much higher quantities of organic matter and nutrients.These higher quantities were probably due to low soil temperatures(microclimate)and high acidity in the beech plot(species effect)that slowed down decomposition.In the mineral soils,the propagation of random error derived from random errors of the individual soil layers was an important factor in the statistical comparisons.Because of the soil acidity in the beech plot,the stocks of exchangeable base cations were significantly higher in the oak plot,whereas the other nutrient stocks did not differ.展开更多
Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in...Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture areresearched. An activity model of shop floor is presented as the requirement definition of theprototype system. The multi-agent based software architecture is constructed. How the core part inshop floor management and control system, production plan and scheduling is achieved. Thecooperation of different agents is illustrated. Finally, the implementation of the prototype systemis narrated.展开更多
AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making....AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making.METHODS:A retrospective analysis of 69 patients with OFBF was performed(35 treated conservatively,34 surgically).The role of orthoptics in referring to surgery or conservative treatment was retrospectively evaluated,the factors with the highest significance for decision making were identified,and a scoring system proposed using Logistic regression.RESULTS:According to defined criteria,the treatment was unsuccessful in 2(6%)surgically treated and only in one(3%)conservatively treated patient.The proposed scoring system includes the defect size and several values resulting from the orthoptic examination,the elevation of the eyebulb measured on Lancaster screen being the most significant.CONCLUSION:The study demonstrates the benefits of orthoptic examination when making decisions on conservative or surgical treatment and for diagnosing ocular motility disorder(with or without binocular diplopia)in OFBF patients.The proposed scoring system could,following verification in a prospective study,become a valuable adjunctive tool.展开更多
Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and ...Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and floor was considered. Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system. The characteristics of airflow with experiments and computation fluid dynamics (CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet. Riboflavin particles were used as the house dust. For the spatial distribution of riboflavin particles in the ventilation system before operation, due to the influence of gravity, different sizes of particles show smooth decay curve. After floor level slit exhaust ventilation system is operated, the decay rate of the particles becomes faster than that after the ventilation system is powered on, and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.展开更多
In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information...In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information technology. It facilitates the information flow from Shop Floor to other areas of the organization and makes the organizations more integrated and productive. This architecture also facilitates the expansion of the Shop Floor functions without disturbing the basic infrastructure. Effectiveness of the BIT-PAC architecture was checked by developing and running application software on a network PC which has supported the dynamic flow of information from Sub-Producers and Sub-Movers to other areas of organization.展开更多
In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for ma...In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for making a strategic decision and reasoning of the system of prevention and control of mine floor flood are introduced. The applied examples are given at last.展开更多
The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the locati...The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the location optimization of the 74 sets of dampers on the floor. The main content includes the establishment of a 2D dot-matrix model for the structure, the optimal location combination searched by a genetic algorithm, and the optimal results for five working conditions by calculating the total weight.展开更多
基金Projects(2004G028, 2004G016) supported by the Science and Technology Development Program of Railways Department, China
文摘Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large bridges in the world. These two types of railway floor systems of the two bridges have never been used in China before. The problem how to conform the deformations and stress levels of the railway floor system of WTC Bridge was studied. After finite element analysis and comparison,the plan of arranging one expansion stringer every two panels in railway floor system were proposed and good effect was obtained. Because of the application of three trusses,the allocation of the loads acted on the deck in three trusses is different and varies in different places of NDC Bridge. This problem was studied by model experiment and 3D finite element analysis. The results of 3D FEM analysis coincide with the model test results. The allocation rule of the loads acting on the deck in three trusses was presented. Because of the application of monolithic decks,the stiffness and structural integrity of NDC Bridge are high.
基金The National Science and Technology Pillar Program during the 12th Five-Year Plan Period(No.2011BAJ03B14)the National Natural Science Foundation of China(No.51376044)
文摘In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the off-peak period and use them in the peak period. An experimental setup was developed to study the heat transfer characteristics of the new system under both cooling and heating modes. The experimental results show that the double-layer radiant floor system with PCM can meet both the cold and thermal requirements of users. Moreover, with the same duration of the thermal energy storage process, the increase of water temperature supplied to the system can improve the heat transfer characteristics of the system but lead to the discomfort of users. On the other hand, if the air temperature at the end of the thermal energy storage process is the same under different conditions, the increase of supplied water temperature will decrease the thermal energy storage time and ensure the comfort of users.
文摘The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize the RC ribbed floor system,including floor and underground garage roof.By considering the effects of reinforcement,the principle of virtual work is applied to calculate the deflections of components.Construction cost is taken as the objective function and the constraint conditions are required to satisfy.Accordingly,the optimal layout,the optimal sections of the beams and slabs and the corresponding reinforcements are obtained for different column grids.In this investigation,the RC ribbed floor system is optimized according to the Chinese standard,whose column grids are 8.4 m and 8.4 m.The performance of the ES-PSO algorithm is good enough,which can be applied to practical engineering.The paper can also provide a basis for subsequent optimization design of monolithic structures.
文摘Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cost and input energy comparisons of RC office buildings of different floor systems.Conventional solid,ribbed,flat plate and flat slab systems are considered in the study.Building models in three-dimensional using extended threedimensional analysis of building systems(ETABS)and in two-dimensional using slab analysis by the finite element(SAFE)are developed for analysis purposes.Analysis and design using both software packages and manual calculations are employed to obtain the optimum sections and reinforcements to fit cities of low seismic intensities for all the considered building systems.Two ground motion records of low peak ground acceleration(PGA)levels are used to excite the models to measure the input energies.Uniformat cost estimating system is adopted to categorize building components according to 12 divisions.Also,Microsoft(MS)Project is utilized to identify the construction cost and duration of each building system.The study shows that floor system significantly causes changes in the input energy to structures.In addition,the slight increase in the PGA increases the amount of input energy particularly flat plate system.Estimated cost of the flat plate system that the flat slab system is of higher value as compared to ribbed and conventional slab systems.The use of drop panels increases this value as well.Moreover,the estimated cost of the ribbed slab system exceeds that of conventional system.
基金funded by the SWJTU Science and Technology Innovation Project(2682022CX008).
文摘The Noise,Vibration,and Harshness(NVH)experience during driving is significantly influenced by the sound insulation performance of the car floor acoustic package.As such,accurate and efficient predictions of its sound insulation performance are crucial for optimizing related noise reduction designs.However,the complex acoustic transmission mechanisms and difficulties in characterizing the sound absorption and insulation properties of the floor acoustic package pose significant challenges to traditional Computer-Aided Engineering(CAE)methods,leading to low modeling efficiency and prediction accuracy.To address these limitations,a hierarchical multiobjective decomposition system for predicting the sound insulation performance of the floor acoustic package has been developed based on an analysis of the noise transmission path.This approach involves introducing a 1D-Convolutional Neural Network(1D-CNN)model for predicting the sound insulation performance of the floor acoustic package,thereby avoiding the limitations of conventional CAE approaches that rely solely on“data-driven”methods.The proposed method was applied and tested using specific vehicle models,and the results demonstrated the effectiveness and superiority of the proposed approach relative to those obtained using 2D-CNN and Support Vector Regression(SVR)models.
文摘At a critical juncture of global industrial transformation and economic recovery,the 2026 China Expo Forum for International Cooperation(CEFCO)recently concluded in Wuhan.Dubbed the“Davos of the exhibition industry”,the forum,attracted more than 600 exhibition professionals from over 20 countries and regions.
基金supported by the Tianjin Enterprise Science and Technology Commissioner Project(Grant No.23YDTPJC00740,Grant No.24YDTPJC00610)the Tianjin Tiankai Higher Education Science and Technology Innovation Park Enterprise R&D Special Project(Grant No.23YFZXYC00027).
文摘The shop floor dynamic scheduling system based on human-computer interaction is the use of computer-aided decision-making and human-computer interaction to solve the dynamic scheduling problem.A human-computer interaction interface based on Gantt chart is designed,which can not only comprehensively and quantitatively represent the scheduling process and scheduling scheme,but also have friendly human-computer interaction performance.The data transmission and interaction architecture is constructed to realize the rapid response to shop floor disturbance events.A priority calculation algorithm integrating priority rules and dispatcher preference is proposed,which realizes the automatic calculation of priority for the dispatcher's reference and reduces theirburden.A man-machine interactive shop floor dynamic scheduling strategy is proposed.When solving the dynamic flexible job shop scheduling problem caused by machine tool breakdown and urgent order,the origin moments obtained by using this strategy are 0.4190 and 0.3703 respectively.As can be seen from the origin moment indicator,the dynamic shop floor scheduling system based on the human-computer interaction is efficient and reliable in solving dynamic scheduling problems,and related strategies of this system are also feasible and stable.
基金supported by the National Natural Science Foundation of China(Nos.U22A20165 and 52474156)the Key Research and Development Program of Xinjiang Uyghur Autonomous Region(No.2023B01010-1)the China Scholarship Council(No.202406420054).
文摘Water inrush hazards from the floor strata of longwall workingface are commonly encountered in North China coalfields,which essentially result from the evolution of permeability in the floor rock under complex mining-induced stress conditions.Current research rarely addresses the evolution of rock permeability under such complex stress paths.Describing this evolution using only one stress parameter,such as effective stress,deviatoric stress,axial stress,or confining stress,is highly challenging.In this study,we developed a laboratory loading scheme that simulates mining-induced stress evolution.Hydro-mechanical experiments were conducted to investigate the evolution of rock permeability under mining stress.The mechanism on the change of stress-permeability relationships in mining-disturbed rock is revealed,supporting to the analysis of management strategies for floor water-inrush disasters.The results show that rock permeability evolves through four stages,including rapid decline,gradual fluctuation,sharp increase,and slow attenuation.1–2 permeability surges occurred during mining-stress loading,closely linked to the emergence and reversal of deviatoric stress in magnitude and direction.With the first permeability surge,the deviatoric stress within the mudstone reached approximately 1.7 MPa,whereas that of the sandstone was about 1 MPa.The second permeability surge in the mudstone corresponded to the secondary rotation of the principal stress direction.CT and ultrasonic tests suggested an increase in microcracks in both rocks during the first permeability surge.However,the deviatoric stress-permeability plot before and after mining indicated that the fracture of mudstone sample changed significantly,while that of the sandstone remained unchanged.The permeability surges observed at different stages are interpreted as resulting from shear-induced reopening of pre-existing fractures and the formation of new shear-failure fractures.A stress-permeability model jointly governed by effective mean stress and deviatoric stress was established.Furthermore,two strategies are proposed for the floor water-inrush disasters prevention,(i)timely backfilling to reduce deviatoric stress,(ii)grouting after the first permeability surge.This work provides insights into stress-seepage behavior in rocks under complex stress evolution and offers new perspectives for identifying potential water inrush pathways in the floor strata of coal seam during longwall mining.
文摘This paper presents an experimental analysis of a solar-assisted powered underfloor heating system,designed primarily to boost energy efficiency and achieve reliable desired steady-state temperature in buildings.We thoroughly tested the system’s thermal and operational features by subjecting it to three distinct scenarios that mimicked diverse solar irradiance and environmental conditions.Our findings reveal a strong correlation between variations in solar input and overall system performance.The Solar Fraction(SF),our key energy efficiency metric,varied significantly across the cases,ranging from 63.1%up to 88.7%.This high reliance on renewables resulted in a substantial reduction in backup power;consequently,the auxiliary electric heater was only required to supply between 1.82 and 3.00 kWh over the test periods.The circulation pump operated on a precise control logic,engaging below 20℃ and disengaging at 21℃.Crucially,the experiments verified the system’s ability not only tomeet the air temperature setpoint but also to ensure the floor surface temperature stayed within required international comfort criteria.These robust results directly support the study’s main objective.For practical application,we advise increasing the total length of the embedded pipe network.This crucial adjustment would allow for a reduction in the required circulating water temperature,which in turn maximizes the utilization of low-grade solar heat and optimizes radiant heat delivery toward achieving the desired steady-state temperature.Ultimately,the study confirms that solar-assisted underfloor heating offers a technically viable,sustainable,and energy-efficient solution with the potential to significantly cut fossil fuel consumption.
基金supported by Joint Program on Health Science&Technology Innovation of Hainan Province(WSJK2024QN093)Discipline Leader Development Program for Outstanding Talents of Hainan West Central Hospital.
文摘Objectives:Postmenopausal women with stress urinary incontinence(SUI)exhibit low androgen expression.This study aimed to evaluate the efficacy and safety of vaginal androgen combined with pelvic floor muscle training(PFMT)in the treatment of SUI in postmenopausal women.Methods:Postmenopausal women with SUI were recruited from Hainan West Central Hospital between January 2024 and March 2025.Participants were randomly assigned in a double-blind manner to receive either vaginal androgen cream combined with PFMT(treatment group)or a visually identical placebo cream(without androgens)combined with PFMT(control group).The vaginal cream was applied to the vaginal wall at a dose of 0.5 g per application,twice weekly for a total of 10 applications,while PFMT was conducted for 8 weeks.The clinical efficacy and safety were compared between the two groups.Results:A total of 61 patients were finally enrolled,with 31 in the treatment group and 30 in the control group.At both 3-month and 6-month follow-ups,the treatment group demonstrated significantly lower values in daily pad usage(p<0.05),24-h pad test scores(p<0.05),and ICIQ-UI SF scores(p<0.05)compared to the control group.The improvement rate of urinary incontinence was significantly higher in the treatment group(p<0.05).Compared to baseline,the treatment group showed statistically significant reductions in all three outcome measures(all p<0.05).No severe adverse events were reported in either group during the treatment period.Conclusions:Androgen therapy combined with PFMT significantly improved the urinary incontinence remission rate in postmenopausal women with SUI,with no severe adverse effects observed.These findings suggest that androgen therapy may represent a novel therapeutic approach for SUI management in postmenopausal women.
基金funded by Vietnam National University Ho Chi Minh City(VNU-HCM)under grant number DS.C2025-28-06.
文摘Vaginal delivery is a fascinating physiological process,but also a high-risk process.Up to 85%–90%of vaginal deliveries lead to perineal trauma,with nearly 11%of severe perineal tearing.It is a common occurrence,especially for first-time mothers.Computational childbirth plays an essential role in the prediction and prevention of these traumas,but fast personalization of the pelvis and floor muscles is challenging due to their anatomical complexity.This study introduces a novel shape-prediction-based personalization of the pelvis and floor muscles for perineal tearing management and childbirth simulation.300 subjects were selected from public Computed Tomography(CT)databases.The pelvic bone nmjmeshes were generated using a coarse-to-fine non-rigid mesh alignment procedure.The floor muscle meshes were personalized using the bone mesh deformation information.A feature-to-pelvic structure reconstruction pipeline was proposed,incorporating various strategies.Ten-fold cross-validation helped determine the optimal reconstruction strategy,regression method,and feature sizes.The mesh-to-mesh distance metric was employed for evaluating.The statistical shape relation-based strategy,coupled with multi-output ridge regression,was the optimal approach for pelvic structure reconstruction.With a feature set ranging from 3 to 38,the mean errors were 2.672 to 1.613 mm,and 3.237 to 1.415 mm in muscle attachment regions.The best-and worst-case predictions had errors of 1.227±0.959 mm and 2.900±2.309 mm,respectively.This study provides a novel approach to achieving fast personalized childbirth modeling and simulation for perineal tearing management.
文摘The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on traditional hierarchical architecture and the top down approach and depend structurally on their specific configuration and job scheduling. Not only can they hardly satisfactorily adapt to these increasing changes and disturbances, but also make the redevelopment and maintenance of shop floor control system (SFCS) to need high cost and much time. And SFCS based on the heterarchical architecture don′t provide a predictable and high performance system, especially not in the heterogeneous environments, where the resources are scarce and the current decisions have serious repercussions on the future performances. For this reason, the heterarchical control is hardly applied in industry. Obviously, it is necessary to develop a new structural framework of reconfigurable SFCS to improve their agility, flexibility and maintainability. This paper presents a holonic framework of reconfigurable SFCS based on holonic manufacturing concepts. The framework is composed of resource holons, product holons and other staff holons. The model of each holon and the co operative mechanisms of holons are described. To verify the proposed approach experimentally, a prototype reconfigurable SFCS for a flexible manufacturing shop floor producing discrete parts is implemented.
文摘To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.
基金financially supported by the Programme of "Effects of Atmospheric Pollutants on Forest Ecosystems" from the Ministry of Agriculture and Foodthe Greek Ministry of Environmentthe European Commission
文摘The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous area of northeastern Greece in 2010–2015.The foliar litterfall for both species reached about 70%of the total litterfall,and was significantly higher from the other two fractions(woody and rest litterfall).The fluxes of masses and nutrients were compared between ecosystems for each fraction separately.Only one significant statistical difference was found,that of K in the woody litterfall.In addition,the stocks of masses and nutrients were calculated in the forest floors and mineral soils of the two ecosystems.Likewise,the stocks of nutrients in the forest floors and mineral soils were compared between ecosystems.In the L horizon of the forest floors,statistical differences,as a result of species effect,were found for the stocks of Ca and N.In the FH horizons,the masses and all the nutrient stocks differed significantly,as the beech plot had much higher quantities of organic matter and nutrients.These higher quantities were probably due to low soil temperatures(microclimate)and high acidity in the beech plot(species effect)that slowed down decomposition.In the mineral soils,the propagation of random error derived from random errors of the individual soil layers was an important factor in the statistical comparisons.Because of the soil acidity in the beech plot,the stocks of exchangeable base cations were significantly higher in the oak plot,whereas the other nutrient stocks did not differ.
基金This project is supported by National Natural Science Foundation of China(No.50105006,No.59990470)(No.2001AA412140).
文摘Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture areresearched. An activity model of shop floor is presented as the requirement definition of theprototype system. The multi-agent based software architecture is constructed. How the core part inshop floor management and control system, production plan and scheduling is achieved. Thecooperation of different agents is illustrated. Finally, the implementation of the prototype systemis narrated.
基金the Ministry of Health,Czech Republic Conceptual Development of Research Organization(FNOs/2017).
文摘AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making.METHODS:A retrospective analysis of 69 patients with OFBF was performed(35 treated conservatively,34 surgically).The role of orthoptics in referring to surgery or conservative treatment was retrospectively evaluated,the factors with the highest significance for decision making were identified,and a scoring system proposed using Logistic regression.RESULTS:According to defined criteria,the treatment was unsuccessful in 2(6%)surgically treated and only in one(3%)conservatively treated patient.The proposed scoring system includes the defect size and several values resulting from the orthoptic examination,the elevation of the eyebulb measured on Lancaster screen being the most significant.CONCLUSION:The study demonstrates the benefits of orthoptic examination when making decisions on conservative or surgical treatment and for diagnosing ocular motility disorder(with or without binocular diplopia)in OFBF patients.The proposed scoring system could,following verification in a prospective study,become a valuable adjunctive tool.
基金Project supported by Ministry of Land, Infrastructure, Transport and Tourism of Japan Project(DUT10RC(3)103) supported by the Fundamental Research Funds for the Central Universities in China+2 种基金 Project(20111027) supported by the Liaoning Provincial Scientific Research Foundation, China Key Project (2012BAJ02B05) supported by the Twelfth Five-Year National Technology Program of China Project supported by Dalian Municipal Construction Technology Program, China
文摘Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and floor was considered. Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system. The characteristics of airflow with experiments and computation fluid dynamics (CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet. Riboflavin particles were used as the house dust. For the spatial distribution of riboflavin particles in the ventilation system before operation, due to the influence of gravity, different sizes of particles show smooth decay curve. After floor level slit exhaust ventilation system is operated, the decay rate of the particles becomes faster than that after the ventilation system is powered on, and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.
文摘In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information technology. It facilitates the information flow from Shop Floor to other areas of the organization and makes the organizations more integrated and productive. This architecture also facilitates the expansion of the Shop Floor functions without disturbing the basic infrastructure. Effectiveness of the BIT-PAC architecture was checked by developing and running application software on a network PC which has supported the dynamic flow of information from Sub-Producers and Sub-Movers to other areas of organization.
文摘In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for making a strategic decision and reasoning of the system of prevention and control of mine floor flood are introduced. The applied examples are given at last.
基金Funded by the National Natural Science Foundation of China(No.51278106)the Scientific Program of the Bureau of Education,Fujian Province(No.JA15629)
文摘The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the location optimization of the 74 sets of dampers on the floor. The main content includes the establishment of a 2D dot-matrix model for the structure, the optimal location combination searched by a genetic algorithm, and the optimal results for five working conditions by calculating the total weight.