Large vertical steel tanks for fluid storage are usually constructed on soft foundations, so it is not surprising that the tank wall will settle unevenly with the settlement of the foundation, thus inducing deformatio...Large vertical steel tanks for fluid storage are usually constructed on soft foundations, so it is not surprising that the tank wall will settle unevenly with the settlement of the foundation, thus inducing deformations and stresses in the tank. This work investigates the linear static behavior of floating-roof tanks under harmonic settlement through finite element (FE) analyses. The influences of the radius-to-thickness ratio, the height-to-radius ratio and the wind girder stiffness on the structural behavior are first analyzed. Comparisons between the circumferential stresses in the wind girder and the vertical stresses in the tank bottom are then made. The displacement and the stress along the tank height are also discussed, and the concept of tank division along its height is presented. Finally, a design approximation for the radial displacement at the tank top is developed based on FE results, and a settlement criterion based on the top radial displacement is proposed which can be used in practical design.展开更多
With the increasing attention to environmental protection,it is still necessary to strictly control the oil evaporation loss from the IFRT(internal floating-roof tank)to the atmosphere.Upon using n-hexane as a represe...With the increasing attention to environmental protection,it is still necessary to strictly control the oil evaporation loss from the IFRT(internal floating-roof tank)to the atmosphere.Upon using n-hexane as a representative of light oil,the effects of the WDAs(wind deviation angles)on airflow distribution,the wind speed,the n-hexane vapor concentration,and the evaporation loss rate in the IFRT were investigated,and the mass transfer of the vapor-air was analyzed.The results are shown as follows:when the WDA is 0°,the vapor concentration in the gas space above the floating deck is the lowest;when the WDA is 22.5°,the oil evaporation loss rate is the largest;when the WDA is 45°,the vapor concentration is the highest,but the evaporation loss rate is the smallest.It is recommended to arrange the vent to the wind direction with an angle of 45°to reduce the evaporation loss and protect the atmospheric environment.展开更多
基金Project supported by the National Natural Science Foundation of China (No. 50208017) and the Scientific Research Foundation forReturned Overseas Chinese Scholars, Ministry of Education (No.J20040157), China
文摘Large vertical steel tanks for fluid storage are usually constructed on soft foundations, so it is not surprising that the tank wall will settle unevenly with the settlement of the foundation, thus inducing deformations and stresses in the tank. This work investigates the linear static behavior of floating-roof tanks under harmonic settlement through finite element (FE) analyses. The influences of the radius-to-thickness ratio, the height-to-radius ratio and the wind girder stiffness on the structural behavior are first analyzed. Comparisons between the circumferential stresses in the wind girder and the vertical stresses in the tank bottom are then made. The displacement and the stress along the tank height are also discussed, and the concept of tank division along its height is presented. Finally, a design approximation for the radial displacement at the tank top is developed based on FE results, and a settlement criterion based on the top radial displacement is proposed which can be used in practical design.
基金the National Natural Science Foundation of China(No.51574044)the Key Research and Development Program of Jiangsu Province(Industry Foresight and Common Key Technology)(No.BE2018065)+1 种基金the Postgraduate Research&Practice Innovation Program of Jiangsu Province(No.KYCX182630)the Nature Science Foundation of Jiangsu Province(No.BK20150269)。
文摘With the increasing attention to environmental protection,it is still necessary to strictly control the oil evaporation loss from the IFRT(internal floating-roof tank)to the atmosphere.Upon using n-hexane as a representative of light oil,the effects of the WDAs(wind deviation angles)on airflow distribution,the wind speed,the n-hexane vapor concentration,and the evaporation loss rate in the IFRT were investigated,and the mass transfer of the vapor-air was analyzed.The results are shown as follows:when the WDA is 0°,the vapor concentration in the gas space above the floating deck is the lowest;when the WDA is 22.5°,the oil evaporation loss rate is the largest;when the WDA is 45°,the vapor concentration is the highest,but the evaporation loss rate is the smallest.It is recommended to arrange the vent to the wind direction with an angle of 45°to reduce the evaporation loss and protect the atmospheric environment.